Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutARCO - CPF #1... . , an-~9~~ma~~~iaY~/X91.~~~'/.~L~/oL®~.~i.,A~/.~~N/®/sC~Ye6'/BL®iw~ZB/~f/s/I/.I~.PIL~WYY,9'/,r/eD~M~aY/~i.~'/.~'/,~DG ~ ~ ~ ~~~ia~ ~ pia , Y~/.,(~L~L,~'i.~~h/,~'w~m/~~.~r~/~~~~~~~ ~ u~ , ~jd~-OJ~'H ~66i Sail, uol~ISOdsiQ S~~ ~'/~.NY.p/MYN/.V%O/.~/~/~/.8'/.d//®/N/~///®/~P/iJ%Q//~~/A/B/O/IY.Y/~1'/~/~/.d/~'/~/rY'/,~/~1Y~T.~ ~ ~ ~ i~'/~/.~/~/~/.~/rN/~/~i.4N/®%64/~/.&~/!~/.M/~'/.Y/~/~/~'/N/~'/~:tl`~~YII7,®/N/AW.9 % m.":rPfd: r ' o !~ A , a '~'' ,a.. ~Nes + ~ ,>. ... ; ARCO Alaska. Inc. Post Cffice E~ ~x 100360 Ancho: b~-, =~laska 99510-0360 Teleph=-~~-~+~ ~~J7 276-1215 February 10, 1998 To: Recipients of Kuparuk Producer's Report of Gas Disposition /~ ~/ Enclosed is a revised copy of the Gas Disposition Report for Kuparuk CPF1 Facility during December 1997, along with Gas Flaring or Venting Incident Report for volumes flared over one hour. If you have any questions, please contact Maureen Dolphin at (907) 263-4629. Sincerely, ~~ ~~ Ed Hendrickson, Supervisor Production & Revenue Accounting EH/mad Enclosures ,,~ s shy : ~ ~ ~ ~°~ `~ ~ ~".~' ~~?~»~ ~ 13i ; f ALASKA OIL AND GAS CONSERVATION COMMISSION ~ ~ ~ ~ ~` ~ FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY #1 ARCO iwASKA, INC. KUPARUK RIVER UNIT 12/97 Disposition Volume MCF* 1. Sold 16.398 2. Reinjected 2,477,031 3. Flared or vented less than 1 hour ~,- ~.J ~ ~,~~ 6,943 4. Flared or vented ¢reater than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 ~~ r/. ; Srt~ 3.546 5. Pilot and Puree 19.760 6. Used for lease operations Fuel 764.923 7.Other 0 TOTAL items 1 - 7 3.294.671 8. NGL eas equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 274.222 11. Transferred to: CPF 3 ('~,~ i a~~ ~i~ 218,292 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certifythat the foregoing is true and correct to the best of my knowledge. Signature: Title: Date: Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER UNI 490100 100.000 KRU WEST SAK 490150 0.00% Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. S r ~ ~ ~ ~ ~ y ~ ARCO ALASKA, INC. O :: N ORDER N0.219 CONSERVATI GAS FLARING OR VENTING INCIDENTS CPF #1 December 1997 .... ,_ _ ..'REVISED*" PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE ~LARING OR VENTING EVENTS GREATER THAN 1 HOUR 12/12/97 0600-1615 2,766 ~ Compressor Shutdown to install changes required PLANNED Faality Maintenance completed 1709-1817 by process hazard analysis. Facility maintenance 1932-2158 12/13/97 0658-0804 131 / Flowin new well. Excessive inlet gas rates. UNPLANNED Reduced inlet gas rates 12/14/97 1757-1945 212 Process upset in gas section of facility. Excessive UNPLANNED Reduced inlet gas rates inlet gas rates. 12/22/97 0454-0619 437 Compressor shutdown. High liquid levels in suction UNPLANNED Restarted compressor after correcting scrubber to STV compressors. high liquid level in STV compressor scrubbers. TOTAL OVE R 1 HOUR 3,546 - ~' ~nl ~ ~ClC~C ~LANNED EVENTS LESS THAN 1 HOUR 0 Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTAL FLAREDNENTED 3,546 6,943 - T -Q~) ` ~ ~ 6,070 19,760 36,319 . ~. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION o c3-, w •. oC~ ~ ~ '~ co • t~ a Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY Ifl ARCO ALASKA, INC. K[IPARUK RIVER UMT 11/97 Disposition Volume MCF* 1. Sold 14.557 2. Reinjected 2,307,031 3. Flared or vented less than 1 hour 4.990 4. Flared or vented greater than 1 hour Su lemental re oR r aired-See 20 AAC 25.235 2.239 5. Pilot and Purge 18.877 6. Used for lease operations Fuel 688.952 7.Other 0 TOTAL items 1 - 7 3.043.971 8. NGL ¢as equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 257.110 11. Transferred to: CPF 3 288,024 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected online 10 or Na tha used in SSEOR meter #201 I hereby certify that /the foregoing is true and correct to the best of my knowledge. Signature: ~/(l ~,..~~.~-- Title: Date: ro ~~ Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARIJK RIVER 490100 100.0090 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: Alt`volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. 4' ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF ff1 November 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTK)N OF INCIDENTS A CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE ~LARING OR VENTING EVENTS GREATER THAN 1 HOUR 11/12197 1144-1301 888 Bring on a new weN. Excessive inlet gas rates UNPLANNED Reduced inlet gas rates 11/18197 2122-2237 147 GLC 1st stage discharge over pressure. High UNPLANNED Reduced inlet gas rates 11/20/97 1115-1230 1659-1728 11/21/97 2232-2351 11/23/97 1729-1834 •11/28197 1055-1218 1224-1328 1724-2024 TOTAL OVER 1 HOUR ambient temperatures, flare valves opened to relieve system overpressure. 146 Compressor shutdown. Flare valves opened to relieve system overpressure. 39 Compressor shutdown. Flare valves opened to relieve system overpressure 132 High tie ine pressure. Excessive inlet gas rates, flare valves opened to relieve system overpressure. 887 Flaring for drillsite startup. Excessive inlet gas rates. 2,239 PLANNED EVENTS LESS THAN 1 HOUR 0 Flare or Vent Vdutnes: Greater than 1 hour 2,239 Less than 1 hour 4,990 Continuous Assist 7,325 Pilot and Purge 18.en UNPLANNED Stabilized facfliry process and operation UNPLANNED Stabilized fac8iry process and operation UNPLANNED Reduced inlet gas rates UNPLANNED Reduced inlet gas rates TOTAL FLAREDNENTED 33,431 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION • • Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY N1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 10/97 Disposition Volume MCF* 1. Sold 16.263 2. Reinjected 2,378,957 3. Flared or vented less than 1 hour 5.157 4. Flared or vented ereater than 1 hour Su lemental re oR re wired--See 20 AAC 25.235 1.617 5. Pilot and Purae 16.051 6. Used for lease operations Fuel 736.327 7.Other 0 TOTAL items 1 - 7 3.163.445 8. NGL sas equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLS) 232.818 11. Transferred to: CPF 3 286,306 Remarks: Reinjected vol does not include volumes of PBU NGLS aquised for LSEOR reflected online 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: ~~ Title: Date: !t i2- Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER UNI 490100 100.003'0 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF N1 October 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE ~ARING OR VENTING EVENTS GREATER THAN 1 HOUR 10/3/97 1513-1715 607 Process upset in NGL section of facility. Flare UNPLANNED Started/restarted compressor. Restart valves opened to relieve system overpressure. MI pump shutdown. 10/17/97 2136-2316 926 MI Pricess upset in NGL section of facility. MI pump tripped off line due to seal failure. 10/18/97 529-650 84 Process upset in gas section of facility. Flare valves opened to relieve system overpressure. 1st stage disch. relieved due to MI pump sown (NGL loading on (rout end) and rising ambients. TOTAL OVER 1 HOUR 1,617 ~ANNED EVENTS LESS THAN 1 HOUR 0 Flare or Vent Volumes: Greater than 1 hour 1,617 Less than 1 hour 5,157 Continuous Asslst 9,073 Pilot and Purge 16.051 MI pump. Open injection gas rou. UNPLANNED Stabilized facility process and operatan UNPLANNED Reduced inlet gas rates TOTAL FLAREDNENTED 31,898 9 • • ARCO Alaska, Inc. Post Office Box 100360 Anchorage, Alaska 99510-0360 Telephone 907 276-1215 June 2, 1998 To: Recipients of Kuparuk Producer's Report of Gas Disposition /~ ~/ Enclosed are copies of revisions to the Gas Disposition Reports for Kuparuk CPF1, CPF2, and CPF3 Facilities for February through December 1997. These revision were necessary due to corrections in the manner in which gas disposition was being handled, as well as corrections to injection volumes. Reports were produced only for those facilities that had previously been reported incorrectly. CPF1 February -September 1997 CPF2 October and December 1997 CPF3 February -December 1997 If you have any questions, please contact Maureen Dolphin at (907) 263-4629. Sincerely, Ed Hendrickson, Supervisor Production & Revenue Accounting EH/mad Enclosures MAD-K3 ~, ^} ,, ~'rE~r. ALASKA OIL AND GAS CONSERVATION COMMISSION ~ "w ~;~ ~ ~ ;~~ ~ t FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Yeaz of Disposition CENTRAL PROCESSING FACII.ITY #1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 9/97 • Disposition Volume MCF* 1. Sold 15.837 2. Reinjected 2,181,841 3. Flared or vented less than 1 hour 4.586 4. Flared or vented erecter than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 0 5. Pilot and Puree 13.067 6. Used for lease operations Fuel 705.764 7.Other 0 TOTAL items 1 - 7 2.930.054 8. NGL eas eouivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 236.916 11. Transferred to: CPF 3 234,612 Remazks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify th/a/t the foregoing is true and correct to the best of my lrnowledge. Signature: ~~--('1/~.~{._-..- Title: ~u~y - Date: ~ 7- `~ rorm iu-4c~ ~xevisea 4iy~~ *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER 490100 100.00g'o Official Use Onl --Flarin Authorization > 1 hr. 1. Safetv MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. 1. Sold ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 8/97 Disposition Volume MCF* *Indicate contribution of each pool to to 16.249 Pool Name Code Perc 2. Reinjected • 3. Flared or vented less than 1 hour 4. Flared or vented ereater than 1 hour 5. Pilot and Puree 6. Used for lease operations 7.Other TOTAL items 1 - 7 8. NGL eas equivalent produced 9. Purchased gas Fuel 10. Transferred from: PBU CGF (LSEOR NGLSI 2,059,348 8.609 4.593 15.356 706.476 6229 0 2.816.860 0 0 224.741 11. Transferred to: CPF 3 I 166,134 Remarks: Reinjected vol does not include volumes of PBU NGLS squired for LSEOR reflected on line 10 or Naptha used in SSEOR meter #201 I hereby ce,,rt~ify t/h/at the foregoing is true and correct to the best of my knowledge. Sienature: C./~~1~.~.,~ Title: c5~-oc.v / Date: ~.~z~9~ ~µ4~~ K[JPARIJK RIVER 490100 100.0090 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Con]missioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Form 10-422 (Revised 4/95) ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 August 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 11/8/97 1410-2354 4,593 Unplanned flare due to electrical instrument malfunction UNPLANNED Corrected electrical instrumentation. TOTAL OVER 1 HOUR 4,593 PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour 4,593 Lesa than 1 hour 8,609 Continuous Assist 6,229 ~ilot and Purge 15.356 TOTAL FLAREDNENTED 34,787 FROM: ENVIRONMENTRL FAX NO.: 907 659 7712 88-07-97 07:03R P.81 ARGO µt.+-.SrtA, INC. • KUPaMUtz ~stvt:tt tItLV FACtLtlilf: C r ~ J Permit No.:~? . .~ p 1~ Gu Y cAS oiSPOSrTION _. Yin+e at t]ccurrence- ~,, ~Q ~Q ~AI~ Date of Occurrence: ~ • ~- y,',1 ~R o- VENT' To: (mmldd/yy) cis SaloCUOn) / ~y To: ~pS ,ST~t- To: '~.~i 5 ±~ Tots! Volurte: yS`q 3~r~,tg~F gg~g To~ (rndudes va~,~,. FG..d Whre:rt Gerurarod B/aek Smoke, 1r AaPkaaWe.l To: To' Meter No. (Flare onty);A i - I F l o~~}' Planned npianne (Circle Set ton Total lNirwros F'lucd or Vc~ted: ~~ •-~~~~ ' Vitrxrng dNlnsd as a refwse ro adnospl»re, F(Anng ~ gas IeavNtg rrrruuyn care tIN. ~• (For Gas Venting Incidents, was whrrrte erttprlQ Ort Gas VeritNlp Sproadsfwpr? YE5 or NO (circle one/.J A t3estxiption of Incickrrt: {CtlecK One and Circle ss Applicable) Compressor Shutdown Process upset in sitotbn of ,_.r,.,2~ Y~ lacility ligh Tie Line Pressure FIalrinp Icr drillsite sfiutdown/startup Mara system tasting Outer. ~ DweaeiPHPn of GuMes(Cheoft (irte And Circle a, Applicable} t-liyh sunbivnt tetrtperatures Ettcesslve inlet gas rates Packer Aei:ip l.ontpre6sar Break-In Facility maimenance ,.~_Electrical/inatn,mentadon maklunction Flare valves opeAtrd to relieve system ,,,~,,,~~ Fauny Sput00Wn overpressure Equipment ditticullias with vibrslion Other C. Action Takeet• to Eliminate Cause: (CJteck t7ne and Circle as Applicable} stsnearoelsnad Cpmpra:eRO- ~_Cor-ected QlsGricol/int:trurt:enlation RaducedMcreased inlet gas rates malfunction ~~tJompletld flaua testing Stabilised lacility process and opQtation FacUity maintenance completed Repaired t:awpment difficulties With •~~..•~~.. other. 'Dnr,r,r ~-n 1. Did Incident Gauss 818Ck Smoke? Yes: Notitisd ADEC. ~~~ {pate} {Time) (ALASKA DEPT. OF ENVR. CONSEflVATION Fieo.i A~cport eho Aorkswwrr~ :nlbrrntfrwr tv ~Ot;c within to t~vu-a d!' telephone (!o>y 4es-sods ana /sr written report to ApEG Fin: fgQ~ 16~ti1?Y Data and Time of black atnoke event: From: Vdurne feared which Generated Bteck t3moke pt p;Nerertt From Above): _~ Nt~'F BBL.S Type of IulsbriaJa Burned: ta,edt One) GAS: NGI,.S: _ Other; See irdormatton from Sections A. 8, artd C above (Cause and Corrective /-ction). General Witather: AM Temperalute:,,~_ vylna t3paaa/QireCtian: 1 cc: Er:vironmental, NsK•67 pel9in~ wrtd fix' Fa ity Supe sor Signed (f=AVironmenal Use Only} Fax: Kent AAstcaH, e14. t5ti6 cc; NSK Env. File: 9,7 p01it307.p9 FlaroNonl Fern: (4rff7) Env Fax: iS59-7TtY AUG 7 '97 07 17 907 659 7712 PAGE.001 • • ALASKA OIL AND GAS CONSERVATION COMMISSION ~- ~ ; FACILITY REPORT OF PRODUCED GAS DISPOSITION ~ y ~ ~ ~ ~ ~: ~ ~ Operator Field(s) Month/Year of Disposition iSSING FACILITY #1 ARCO ALASKA, WC. KUPARUK RIVER UNIT 7/97 • Disposition Volume MCF* 1. Sold 16.249 2. Reinjected 1,742,281 3. Flared or vented less than 1 hour 6.282 4. Flared or vented sreater than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 0 5. Pilot and Puree 21.011 6. Used for lease operations Fuel 719.234 7.Other 0 TOTAL items 1 - 7 2.511.001 8. NGL ¢as equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 190.271 11. Transferred to: CPF 3 167,847 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certyyif"~y t~~hrrat the foregoing is true and correct to the best of my knowledge. Signature: t/~~'I.Gt.•rL_r Title: r5~.-,~,c.~.~ Date: ~ L 4' Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER 490100 100.00'90 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ALASKA OIL AND GAS CONSERVATION COMMISSION -~ `~~ ~~ ~ ~ ~, ~ y FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Yeaz of Disposition PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UMT 6/97 • • Disposition Volume MCF* 1. Sold 10.178 2. Reinjected 1,140,772 3. Flared or vented less than 1 hour 16.756 4. Flazed or vented ¢reater than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 278 5. Pilot and Puree 14,423 6. Used for lease operations Fuel 549.669 7.Other 0 TOTAL items 1 - 7 1.735.986 8. NGL ¢as equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 0 11. Transferred to: CPF 3 221,598 Remarks: Reinjected vol does not include volumes of PBU NGLS squired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify t~h/at the foregoing is true and correct to the best of my knowledge. Signature:~~'(,t,•-t.L._ Title:: ~ . Date:- ~y ~ Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KIJPARIJK RIVER tJIVI 490100 100.00g'o Official Use Onl --Florin Authorization > 1 hr. 1. Safetv MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All~+olumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 JUNE 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR • 6/30/97 1538-2331 278 Leak in Vent Valve UNPLANNED Shut valve in and submitted work request. TOTAL OVER 1 HOUR 278 PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour 278 Less than 1 hour 16,756 Continuous Assist 3,910 lot and Purge 14.423 TOTAL FLAREDNENTED 35,367 FROMs ENUIRONMENTHL Fq~ NO.s 987 639 77}2 B -24-97 04s03P P.O1 ••ARCOA s(~$KA .rsrr• ,_q~;,~4-97 16x16 P.el INC. ~ KtlPMIJK t~glJcR qq•p FAGlJ1'Y: ~ p F^ Permit No.: .. tilts DlsPOSmor', Oeta of Ocaurrenoe; -z.t- ~A or V[7VT' ~'~ 2lt~ tmtn/tltl1YY) 'y6rtc'ja 8alpction To: ) Ta: ~`-` Total Vplyma: .~~ ~q _1~• T0; (lrrcard~e Vbhrme flarari N?~! ~prb ~ ~A _~~ To: _ r ~l l~ f~D~e.) Ttf: Meter No. (Flans ony): -~ .. ~ ~ ~~~ Yo• Olahned Unal~nrwrl ~""""• ' ~~+ ' Vendrg deNrred as a rrrsYr~ b ~~. /ie~vrE a~pas feaYlQ'~~ a Total Min rise Flan (FCit tali VwrNrp 11y,'idNl1Y. asRi r04prse erMared on Ga! V ~ a~ (tD. r!rrfor9 rP~vadrhlel? YES or NO (dress er.a~1 A. OeiCflPtltN10! Mefde~C lClfewk t7ne snd Ctrcte as Apptieyb4) ._.,~,_t:OmPrassw 1hutdown / "~~~V - / •-Process upset In ~A5 !action of Nigh Tic une Pressure laoility --~Fl~ vy+ten- betinq ~r A~ hx dr~lsite ;hutttDwnJSfartref B. Dese.;ption of CauaexChttett One and Circle as AppNoabia) ~,liigh sunbfent tampeiatu-es ~_ Pas;lser Rerip GomProasor 8reakrln `` Electrtmmantatfon maltunoryon ._„~ Fautty shutdown ~` ~,`,_H4uiprnent dbtiCuMies with Yibratian Other. G Aetlon Taten b ~tninaM t~avse: (~~ p~ attl s:i -~..~.-St~toryr~ea.Mtl Compreap, Reduce~aeasad +~et ~s tatei _~_Completsd Nanr testing `-~Fa~~ ~im~ar~! tamplatld .~~ dMlr. Oid {ncident Cauca Biadt Smoke? res: Nainea ,oDEC. _,.__, Escatrhre inlet t;ae rake Facniry malntenanca _~`Flare rahsle opened tp feyeYe sy~em ove-P~esaure 'vale as Apppc~) ~, COt-ected electNcaymOfvnrantatipn rneMunctlon StabUizad tacNlty tarocass and operation .~~~Repalfad equiprrlent dittiWgieli with 4 (Date) (Time) (ALASICiI 06PT. OF FNvMt. CONSERVATiQN qeP.) 1~eAOrt tore hflorwrrq inkrtrretfoq b AOEC wlMM ~4 Jray/d by tafsfMarre /y~071 4i6,i0.Z2 ~rrd t~rx Iwfuerr Ilepart b AQEQ Date attd Time of blast smoke evarK: _ F++~ (~07y ees,srsa VOt°"''o Eldred Which t3efeerated Black Smoke (tt Odferont From Ab4ue~; ~ Type d M4terial- 8umw: (Cheele One) t3gt3: NCi,y; _ Othe"-- -~--~'~ Se! lntprmed4n ttan S+Ctians A, B. and C abovw (Cswso one Corroctiw AeYSas). Ctanwal Weather. Alr Tan~peraturo•_ Nfirn. and frhotse rr+mba- d oeroon mekin9 the retwrt~ ~~ SPeedf0lrecdon; ~^_ ce t?rnrtronmencal• NSK tat origins and fox. F INS/ 6 DuMw Signed (t:rnMOnmentet Use poly) Fax: Kent Metcalt• ext. 1666 e0t/007.0e FlaretVerw Form t4/e7y oD: NSK Env. File; g.7 Crsv ryslT e5a•/71~ JUN 24 '97 16 16 907 659 7712 PAGE.001 FROMs pRCO CPF1 FpX NO.s 997 6597749 e7-e1-97 07s35 P.al ARCO ALASKA, INC. • KIJPARUK RNER IgELQ FACiIIT'Yt - PertnN No.• liiAS DISPOStT10N of Occurrettee• Data Ot Occurrence: t'v 3 c t' r ' ~~ ~n ~Q ~a i (FLARE ~br VENT' _ / 5 3 ~ To: '~3Z 1 y~ (mm/dd/YY) ( irde SelectlOn) _~ T0; Ta: Total Volume: ~ 7 M9CF g9tS ~ To• (fncktrtea vola-me F7arod Which Generated Beek Smoke. N Appdabfo.J -_~- To: ~~ To: Meter No. (Flare onty):~ tt~L-~i.Q l MM Planned Unplanned. (Circle Se ion) ~Tp~ Minutos Flan • Verxing do/inod >s • ntraaee to etrrwsptrera, F/arln0 is gas feavMg OrrougA hens dp. (For Gar Vonting rrteidents, was volcano enterod on Gas Verxing SAteadahset7 YES or NO (cimlee one). A. Deacriptivn of Incident: (Chetdt One and Circle as Applicable) Compressor Shutdown Proeass upset in SlCNOn of -.-~~`Yg~~~ facility High Tle Lira Pressure Flaring for driliSite ahutdowNstartup Ftara system testing Other. ~rz..eT V.4~~rt BEAK tt1C ~~iMpyt~fl~ IS< B. Oesortption of Cause:(Cheak One and Circle as ApplieabN} High ambient temperatures Packer Recap Compressor Break-In EtectNcal/instrumentation malfunction Faulty shutdown Equipment dlfficultiaa with Vlbratl0n ~•~ Other. PJ f~L~ lS ~L Excessive inlet gas rates Facility maintenance flare valYea opened t0 relieve SysMm overpressure c C. Action Taken t0 Elintinats Cause: (Check Otu and Circle as ApplkaWa) Started/restart9d Compraaeor Corroctod otootrieaVinstrumentation ReducedAncreased inlet gas rates malfunction Completed flare IeSting Smbilized taaUty process and operation Faality msirttenance completed Repaired equipment diHiCUltiae with v' Other. St~,..~T VF`i. VfE _1 ~v ~ a,~ U-`~or~ GUaRk h~G:uE~i~`" BL/tt:'K SWIOICE Incidsnt Cause Bladc Smoke? Yes; tied ADEC. ~~" (Date) (Tune) ~ (ALASKA DEPT. OF ENVR. CONSERVATION Flep.) Report the lollowing (ntormetlor to ADEC within 24 hours by tNephon@ (907) 465-502? and hx Itrritten rrport to ADEC Fix: (907) 46S•Sf?9 Date and Time of black smoke event: Frorrt: Volume Fiarad Which Ganersled Stack Smoke (If Oifterent From Above): Mi~F ~lS Type of Materials 8umed: (Check One) QAS: Nl3Ls: ,,,,_ Other: See information tram Sections A, B, and C above (Cause and Correctrve Action. General weather: Air TQmperature: Wlnd Speed/Direction: FaCUity Su or 001/007,08 FlarN1/ernt Form (4107) JLN- i ' 97 07 ~ 52 ~,r . ±~ _ J~~~ _ ec: Environmental, NSK•61 onyiri~ai anti fax D to gned (Environmental Use nly~ Fnx: Kent Marcell, ~f(f ~l`SSti' cc: NSK Env, Fila: 8.7 Env Rea: 850.771 Y 90? 659?749 ~:(i3tll~:~Tt FAGE.601 • • ALASKA OIL AND GAS CONSERVATION COMMISSION `~h' '~ ~ ~ ~~ FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 5/97 • Disposition Volume MCF* 1. Sold 23.782 2. Reinjected 1,539,493 3. Flared or vented less than 1 hour 7.308 4. Flared or vented ereater than 1 hour Su lemental re oR re uued--See 20 AAC 25.235 3.258 5. Pilot and Puree 8.702 6. Used for lease operations Fuel 663.460 7.Other 0 TOTAL items 1 - 7 2.254.502 8. NGL eas eouivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 0 11. Transferred to: CPF 3 313,727 Remarks: Reinjected vol does not include volumes of PBU NGLS squired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: (~`~~~,,,,,~_~ Tide:~~~..,t,~~r/ • Date: L ~`~ Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER UM 490100 100.00R'o Official Use Onl --Flarin Authorization > 1 hr. 1. Safetv MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 MAY 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR • 5/24/97 0000-0947 3,258 Halon release in Zone#4 resulting in faciliy shutdown & restart. UNPLANNED Repair vent to flare off STV system. TOTAL OVER 1 HOUR 3,258 PLANNED EVENTS LESS THAN 1 HOUR 5/7/97 0839-0844 139 Vent VGC09 ENFL drum to Flare Remove ~(GC09 drum from service for Plant upgrad PLANNED Facility Maintenance completed Flare or Vent Volumes: Greater than 1 hour 3,258 Leas than 1 hour 7,308 Continuous Asstst ~ 8,499 Ilot and Purge 8.702 TOTAL FLAREDNENTED 27,767 CJ ALASKA OIL AND GAS CONSERVATION COMMISSION i~ FACILITY REPORT OF PRODUCED GAS DISPOSITION ~ ~ ~~~ Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 4/97 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold 27.978 Pool Name Code Percent 2. Reinjected 1,686,658 KUPARUK RIVER 490100 100.003'0 3. Flared or vented less than 1 hour 6.606 " 4. Flared or vented ereater than 1 hour 1.756 Su lemental re ort re aired--See 20 AAC 25.235 _, .~ 5. Pilot and Pure 14.588 6. Used for lease operations Fuel 718.539 7.Other 0 TOTAL items 1 - 7 2.461.802 8. NGL sas equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 226 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date 11. Transferred to: CPF 3 340,794 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: ~~i,~G~,..il~..- Title: ~ r _ Date: L •z y~ Form 10-422 (Revised 4/95) Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 APRIL 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR ~~ u ,~/'Gr/97 0245-1000 1,756 Unplanned flare due toEmergency shutdown. UNPLANNED Corrected electrical/instrumeon , ~ • $~ ~ ti. ~-,~ °~ « ~ cei . ~~ TOTAL OVER 1 HOUR 1,756 ,a,~,.. - ~~,,~,,,,~ ,~n,_; :..~ ca ~-~,, t~.~ ~~ ~ Flare or Vent Volumes: ~ ~ Greater than 1 hour 1,756 ~- '~ Less than 1 hour 6,606 ~ Continuous Assist 5,677 _~ Pilot and Purge 14.588 ~' TOTAL FLAREDNENTED 28,627 ° FROM s ENS I RON~ ENa pL ~act~: FAX NO.: 907 659 7712 04-25-97 11:248 P.01 • FRit N0,• 747 63 7749 04-25-97 95=40 p.01 AM4u Mt.,aSa;q INC. ~ l{UPARUK R1V~A ~D I / PerntN No.: 9,~~,3 - ~iQOo Y ~ r .. DaIO of OccunynCe; Qt3D1! RE or VENt'• 1.0.4 1!'uatdaR fmnuodtyy} tCtrQle Sslecy,Qn To: -~~ ~_ } 'T~p; TOta1 Volume: ~r,,` }L~p ~~ To: (h+~krds ValWine paw L*'~`-L~' ,t3~^ itDt~^ ~~ Qenenre0 stack Smoke. n,vpp+~eble. ~-~-~ 7.O: ` Matt!t No. (Elate anly};~~~ ~~~. Ptenned ~_ To: Unel/ ann.a 1 ~~ • y~"~9 tkhnM wr s rasa. ro atnropprura (Circle Se eclton Total M;nutos F7.ry (For Gas Ventrrlq Incrtler,ts. was YDrurr-e ~7arx,9't pas lennr,g rnrvuyh bars trp. enterrd en Gd8 Ve,K,~ S~:~Mar7 Yt3 pr NO (crera en9f.) A.Oe . serrpdoe of lncidene: (~eK One and Ctrctt! as AppliCSW@) Co~Shutdown Pro ~ilitDOVVN ~ ,~_ cess ups@t in ,~^_ ~et10n of ~~ H+gh Tie Line Pressure fat;itity ~_Ftare system testing -- -:_~ann9 for drillsita shutdown/e,tArtup othQr, 8. Description o? Cause:(Chtck t3n ra and Cirae eq appikable) ~,Htgh ambient tamt7eratur es _~~ Packer Rec,p Co ,-. n-phessor$reak-In _ ~„Eloctr,e.v;nytn,rn~tat, ~_ Excessive inlet ges rstes ~'t=arrtlry matneenanee orf maltunct~Dn Faulty shutdowns _ Flare Vawes opened to relieve rystm ~.~.Fqu-tstnent dinicutt+es wrth vlbraiwn °Ye:Presaure C. Action Takgn t0 Blirulnate Cause: (C?teck Orte and CirCla u ~~~ ~itarted/restarted Compr. ~~~~~ wor '~~ erected atvctrica~nstrumarttatton -~ Rv~+og~increated Inlet gas rates ."~„`Ctx+nptetad Hero testing Rnslrurfeti~n ~`Fae,Gty m;unrenanse completed "~` ~ ~---SfahiNZt;d tacitlry pr°cess and operatbn ._ Repaired equipment tliHiCUlties -.~_ O,her• with ,~~ -----..~ BLACK SMOKE Did inc,dent Cause Stack Smoke? Yes: Notitieq ADEC. ~-- (D- A ~ (r--~-_ fl4t.ASlCA OEIiT. OF CVVR. t'.ON9ERYATIOtV App.} IPaporr tM /oeawin~ irttwrnadon fo aDEC wrrr,ln 2~ ton+rs by rereplrone r90~ fifrSD?2 an0 f~ wrreeavr rooort b IOE~ Date antl TimO Oi` black SmOkO asrenf: tr+sc (9D7~ a8J•8!?' Voluthe FIarM yyf»oh t38rserateq plaek Smoke (It OoHerent From Typs of Materiits 8urngd: ICheek 4„ot QAS: Above>: J4l~ 9EIL8 bee ,r:townappt tram Secbor>s A, B, and C above tCauce and CnrurectNV Action) v~' ~_ L3aneral weather. Air ~- 4ame and none n tuber of Arson Tempen!ure: ki the ranen•. " Wind 5peed/Directipn: ~~ F duty Superv or ~J1 007 tl6 t:larRNenl dorm (u971 ~~S' ' 7 _„ cc: Envtrohmental. NSK•61 oNginaf aM !ax Data Signed (Environ,nernal Uae vny) Fax: Kern Mstcaa, ext. 1886 ~: NSK Env. File: 9.7 Frw as.• aeo.ri~w APR 25 ' 97 11:3:3 90'7 659 7712 PAGE. 001 u ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Yeaz of Disposition CENTRAL PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UNIT 3/97 Disposition Volume MCF* 1. Sold 29.685 2. Reinjected 1,673,786 3. Flared or vented less than 1 hour 3,547 4. Flared or vented ereater than 1 hour Su lemental re ort re uued--See 20 AAC 25.235 190 5. Pilot and Puree 13.423 6. Used for lease operations Fuel 751,787 7.Other 0 TOTAL items 1 - 7 2.478.475 8. NGL gas enuivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLSI 3.844 11. Transferred to: CPF 3 304,657 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: ~~ ~.~--*~---- Title_~~,r Date: Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER 490100 100.00~Yo Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 MARCH 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR • 3/6/97 0245-1000 TOTAL OVER 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTAL FLAREDNENTED • n~ ~::, `... ~_.~, .;,~: 190 Planned flare due to Compressor Valve Replacemen PLANNED Replace Valve. 190 190 3,547 6,057 13.423 23, 217 ' FROMt ENVIRONMENTRL FRX NOy~~ 907 659 7712 03-09-97 10:548 P.81 auTY; `,~~i--~.. o~'t r ~p 93-89-47 Ef.:33 i>,01 cis pISPQRtTIgN Tittle of O r ~ .a• t)ate of flccunenc4: 31-,x=13= ~~ 4~.4 2~oa ~~ r F1JlR ar VEKT• 03yS Tp' ~-~.,C~ (ntm!tlrr/Yf~) . Seiecnortj ~` 7a• Td: Total Volume: ,t p r,Agp 66ZS Tp: (?rtNudaa YMuma Fn7++rd tNM'cn Qor;ersred a4tck SnMk ,! AN ppiicl6fe.) ~_ Tp; ~~~~ I~ Tc; Meter No. (flare onlyl: f -) ~ tanned U anned ~~- "`-" (GirCle SAI°C:ion) Total Mirw,tea Flarce or ventea: ~'~ Ytnfmg dslrnsd as a rekr:~e M annoaphero. ~enng a gera teavrng ntrvtgtt frsra D'p. !~nr Cii! Ventutg rntidlnf~, was tMRxrfe RI!fAHC ort m^tlt tJer:trng SpnESdsl+eet7 YES or NO (t:rlcle orh:).1 A. DetiCriptfon of Itlefeeent: (Check atle and Cirt3le Ae Applktt4k) ,,,"~„„COtnDrpf~O- ShtilgCWn Process upset in aecfion of ~E1'~'YSHIJtDtyifVN facility ~,~iif9h Tie I.i'+e Pressure Flaring fOr dnilSltia shutdown/stah~p Flir@ system t48tihq tither: ~. Daacriptien of Cauae:(Cf!:ack brte and Cirtsfle as Appacabfs) ~,~iii9tt atnbfent terrlpereityrgg ExCes5lve inlet Qas rates _"~~ Petdter Rattle) Compressor Break-tn tacdity main:enance ~~Electrire!~msirumtentatfon rrelfJnctlon Flare vatvtig opened t0 relieve System _,,,,,_~ Faulty shUtCown ~~ overpressure ,~_ Eq~ipmenl dtHiculties With vibr3ts4n ~ •• r/ tJiher. r'aw1PRE~~~c:4C ti'.i~ sir rY~f ~F1~IE~lI.~~~ .~l ~ ~ `~ ~ ~(~~ C. Aedon Taksn to Elltrtinale C;use: (Cheek t3rta and Cirela et AppliOSple) t%'~ ,,,Started/leStaned Comprca>!br Corrected plectricaUinstrumentation ,~~^Fktlueed~ncreaaiyd intot gas races melfunctibn ~„_Com~leted tii#re testinD BteCNgzea faquty pracess ar,p operation ~_~Kxflity maintananCa corr~pletad Repaired t?quipment 41ff~un~eS With _~-~...v_ Other. BLACK SMOKE Did lnadent taus. Stack Smoke' Yes: Notl'ted ADEC. ~....~_ (help) (Time) (ALASKA DEPT.1?!rENVR. COHSERVA710N Rep.) Berate the /eUawJN,j irrlKrtYfiaa' w ADC rr;ehlA s/ heals by >!sMpborae /t70» Ii6-if00 or, +~: ~~d>7 ~as.s~ Ogte and Tme at bhtck smoke event: Fr0111: Volume FlAred Which t3aneratad Black $rnoke tlf OiffereM Frpm At:o.ro): ~~t'~ fB8l~ Typ@ at Materials f9umed: (Chess Crsl CiAS: NOl_5: __._Other• ;See intorlhatt,n from Si1~LIionS A, e, arr~ C above (Cause am Cortpct~ve action), ~~ ~Gpneral Weather; Air 7ernperature: wind SpaaWplrection: i Name at+n phgrtp number of olrson makinn tr,~ rn.,nw• -- - .~ pG Envitotx+anac Cnardinitor, NSK-81 Faailily $uPQ ~ had {tervirontnelnal iJs@ Only) ' Fez: Patnci~ Rafter, c,n. 1566 cc: NSK Env. FHe: 9.7 KQRM.S'aFlan IMdtlrnt @n4.'ye YKa•t~ t"IF~ 9 '97 1101 . 9077712 PAGE.001 ALASKA OIL AND GAS CONSERVATION COMMISSION ~~~UI~~'~ • L~ FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition CENTRAL PROCESSING FACILITY #1 ARCO ALASKA, INC. KUPARUK RIVER UMT 2/97 Disposition Volume MCF* 1. Sold 26.962 2. Reinjected 1,953,527 3. Flared or vented less than 1 hour 3.260 4. Flared or vented ereater than 1 hour Su temental re oR re aired--See 20 AAC 25.235 2.473 5. Pilot and Puree 11.596 6. Used for lease operations Fuel 714.824 7.Other 0 TOTAL items 1 - 7 2.718.229 8. NGL sas equivalent produced 0 9. Purchased gas 0 I0. Transferred from: PBU CGF (LSEOR NGLSI 169.494 11. Transferred to: CPF 3 281,294 Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature ~ , -~~~-- Title: ~~~ Date: ~' i l ~ Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER UM 490100 100.000 Official Use Onl --Flarin Authorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. • ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF #1 FEBRUARY 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 2/17/97 1356-1534 94 Unplanned flare due to leak on Distance Piece UNPLANNED Fix leak • 2/26/97 1145-1340 505 Unplanned flare due to NGL booster pump tubing UNPLANNED Replace tubing connection connection leak 2/26/97 1105-1727 1,840 Unplanned flare due to relief valve failure. UNPLANNED Isolated equipment 2/28/96 1902-2015 34 Unplanned flare due to excessive vapor loading UNPLANNED Discontinued draining NGL from the Glycol Regeneration system to CHD TOTAL OVER 1 HOUR 2,473 Flare or Vent Volumes: Greater than 1 hour 2,473 Less than 1 hour 3,260 Continuous Assist 5,587 Pilot and Purge 11.596 a, ~,r +.~,~.,,~` ~ • TOTAL FLAREDNENTED 22,918 _~ ~.. FROM: ENUIRONMENTfiL FpX N 907 659 7712 02-18-97 08:O1p P.01 C'iAS DISPQ~f i10M LI!'1C Ot OLCUrrence: G.GD9 24QQ ~ Os'4 of OccurrencE: - l7- ~fAR or VEtVT• ~ Yo: 153 .. (min/dQlyyl to Svtscticnl Tp: To: Total Vaumt!; q 3 .'7lo A+le~ tIOLS Tp; ffncludes VolurnQ Flared w>,~, Gerre-atod 91ack Smolro, K Apn&t:ab~.) To: ttDC~.S ~' T o: Meter No, (f=rare on~y): ~Q~ Planned U tanned (Circle Selection; Totdl Minutes 6lered or Vented: ' Vontrnfl dchned as a release ro aM+oaphora FJerurg rs gas Invirg fhrpuyll Ndna rip. (For rsas Venting lncrdenfs, wsc irolunre fiRterMC t7rt Gas Vraltit-g Spr!stdaVtett? YES v- ND fcxae one1J ,tl. DfdiCriptign Ot incident: (Check One and Circle as ApplitiableJ! ~_canaressor shutdown PrOCe a5 upset in sec!lon of E]iAERC,t3~CY S41lJt'DdWt~ faoiUty Hiph TIE line Pressure Flaring for drilisite shuldow~lsTsAup Flare cystem tosNng Othe-: • r - --_. __.___ B. Resoripejorr o+ Cause:{Cheek One and Circle as ApPligttd!) High e.~rtbient terrrperatures Excessive inlet gas rates PACker Pedp Cbmpresaor 8reek-In Facility maintenance EfectricaVinstrumrntation mirifunctlon Flsrt valuer: openea to reaeve system Fealty shitdowrt overpressure s;quitxnent diffi llies with vl~ration _~ Other. r L 14~iL C. Action fAloen to Eliminate Csuse: (Ctreck One srKt Circle ae .'-ppiksbie) sit~u![~direstRRsd Cwnpn!asor Corrected vlectr;ealiinstrumantabon itPduNdfincreased irJel gas rats malfunction Gctraleted flarr3 testing StatHiizQd iaclity process and operation F`eiii i t t ~`I _ lee ty ma n onnnte t~olnp eted RQpaired equiprneni difficulties ~ V. with ,~G=~t~ Ef. l~ ,~ t7ttter. kR V t +.. ~ et.ACit tpuiorcF ~° Did InCitlent cause t3lack Smoke? Yes: t~ ~ d Notified ADE^. ~- ~ (Date) (Time) (At~q$KA DEPT. bF EMVR. CGNSERVA77tJN Rep.) n RMNt 1Ne NllswU/ i1-frnryt;on to.40Etl rvirftin tt hours i~ tt!ephwre UOS) ws-lfoC ol. f~oi: (IOTJ 165~STlI Date and Ting Of b+acit sm~-lee evenr. ?-1'~• 97 From• Vdame Flared %Vttich f3eneraled Dipfrk 3rnoke {ff Om t morn Above); ~r37L ~~ t~l„S, ~ ~, „~ •• Type of Wtaterialg Burned; fChecir oust GAS: tVpLs: _-__ Qther: x . +~ $l'C Itttt)Rrtl8tii0R train Bactinnx A, B, and C above (Cause ana CotrecUve ACtiAO}, ~ ~ 'a General LYRtlttter t~+c1~65 ~ ftO~j Air Tprftpetature:'/'/ Wind Soeed/DirECtion: ? ~iWg ~~~ASr = ` o Name end phone nrxnGer of person makin4 the report: - ,., ~ ° - r ~! ~ ~ ~ ~ ~~ cc: Environmental Coordinator, N9K-8y Facility enlisor Oaw Signed (EnvironmitlnAl ills Only) Fax: Patricia Rahtir, ext. t566 flC: NSK Env. File: g.7 fOpMS'Ftsrq rnpdenr 8H 4/96 Version r. ti FEB 18 '97 08 07 907 659 7712 PAGE.001 FROMs ENUIRONMENTFlL FRx NO.s 907 639 7712 • 02-27-97 06s28n P.01 CO ALASKA, INC, • KUPARUK RNER FIELD CILf1Y: to /~ ~ l C3AS DI~9tT10N Ili~e of rro Date of Occurrence: ~ 4000 2aoa 2 ~ ~ r/ FLARE or VENTr To: , f,~~ ~ (mrn/dd/yy) (Circle Selection) To: ~~ Total Volume: 5'Q.S'~~ ~~ :, To: {lrrcludea Volume Flared Which Generated glaek Smoke, ff A To: ~- l~ PplicaWe.) To• ---- '~-_ Meter No. (Flare on Ta: ly)~ Planned Un tanned (Circle Selection) Total Misses Flared or Vented: • VenNnq derirnad as a rorease to amraspnert,, Flaring is gas Jsavir-y through Hero fig. .. (For Gaa Venting lnciafenb, wag sro/ume entaod an Gra VonNreg SP+'eadalroot? Y$S or NO (circle one).) A. Description of Incident: (Check Ono and Circle as Applicable) ~~Compressor Shutdown Process upset in section of ~ ~1'DONUN facility Nigh Tie Une Pressure Flaring for rfllsite shutdown/st rtup __ Flare system testing Other. L. .C. L M/T s.c.t it,( B. Description of Csuse:(Chssck One and Gircle as Applksblej High ambient temperatures Excessive inlet gas rates Packer Recip Compressor Break-In Facility maintenance ElectrlcaUinstrumentation malfunction Flaro valves apaned to relieve system s^Fquity shutdown overpressure Equipment difficukies with vibration L - .'Other: ~ t.~,~-yt ~,O,j/b/C~- C. Action Taken to FJiminate Cause: (Check One and Circle as Applicable) Slarted/restar'ted Compressor Corrected electrical/instrumentation ~~ Reducestfincroased inlet gas rates malfunction Completed flare testing Stabilized facflity pr4Cess and operation ~~ Felciiity maintenance completed Repaired equipment difficulties Other: with ~~1~c~'~,t/ It! rL 7 ~ O/l/• BLACK SMOKE bid incident Cause Black Smoke? Yes: Notified ADEC. ~~l: ` 7 ~. ~ ~ f`'Q CC q 2c+~`(6 ~ (Date) (Time) {ALASKA DEPT. OR F.NVR. CONSERVATIQN Rep.) Report tree -ollowing intormstion fo ADEC within ?4 hours by telephone (90TJ ~t51-?139 or, Fax; (l7t77) dirt-?J87 Date and Time of black smoke event: From: / y$' ~ /3~/ U Volume Flarod Which Generated Black Smoke (If biiterent From Above : ~~ type of Materials Burned: {Ghects pne) GAS: Nt3Ls: Other: See Information from Sections A, 6, and C above (Cause and Correctn+e Action). general Weather: Air Temparature:^ in S B~/pirection;~ ~7 PN ~/y NAme And nhnnn nrimhsr nr r.nr~nn mwr.r-_ •~_ ____~_ Facility S rvisor FQRM5/Flare lncitlent 1!22/96 Version 2 - ~ ~ ~ ~~ cc: Environmental Coordinator, NSK-61 Date Signed (Environmetnal Use Only) Fax: Patricia Raftor, ext. 1568 cc: Central File: 9.7 FEB 2? '9? 06 34 90? 659 ??12 PAGE.001 FROM: ENUIRONMENTnL FAX NO.sr 987 659 7712 • 82-28-97 12:55P P.el • L111r: GAS OISPOSITIQH CUrr Qeoe 200 ISdIQIS4E bate of Occurrence: ~~ FLARE r VENT• ~~••~- To: Z (mm/dd/yy) role Selection} To: ~~- ~~ ~T To: Total Volume: i7. nnsCS: BBLS To: (lnGluder volume Flarod IVhioh Generated Black Smoke. If AppLca6le.J To: I~ To: Mater No. (Flare oNy}: ~~{~ planned armed (Circle $eleetton Total Minutes Flared or Vented • Vsnt7ny defined as s r~leap ro atmoapnero. FlarirtQ Is Qaa leaaar8 through >Nae tip. (For Gas Venting frtrxdents, rues vo/te-te entered on Gaa VenrmD SpAlsdsheet7 YES or ND (circ/v ene).J a-. Descrtptlon of IndderiC (Chaok One and Circle as Applicable) ~_ Comprarraor Shutdown 946ai3BJCY SHLlrDaiMJ Hiptl Tia Line Pressure Flare system teating Other: G. ~eacription of Ceuiee:(Check One aril Gkcle as Applicable) t~gh ambient temperatures packer Reap Compressor Break•In Efectricallinstrumentation malfunction Faulty shutdown Equipment difficuttie~s with vibration ~_ Other: R P ~ r P.F 1/A l' t l Process upset in section Of facility Flaring for drilrsite shutdown/startup ~ 15Gi ~ ~yl i~(„~~a„ Excessive inlet gas rates Facility maintenance Fiore valves opened to roliava ~yr6tem overpreasunt G. Aa'.ion Taken to Elfminab Cause: (Check one and Cire 8tarted/reatarted Compressor Reduoea/increased inlet pas rates Completed flare testing Faoiliry maintenance completetl ~~_ Other. le ea Applicable) Corrected elttctrlcaVinstrutnentation malfunction Stabili2ed fetidly process and operation Repal-ed 8quipment difficulties with BLACK S1itt7~ Did Incident Cause Black Smoke? Yt:s: Notified ADEC. ~~ (Date) (Time) (ALASKA DEPT. OF ENVR CONSERVATION Rep.) Report the follovina iolbrgreNon to AO~G rrlglin ?4 AOWa by tefeptlprre (9D7) lS6~5100 ag fix: (sOT) 4Q3.57?9 Date and Time of biadc smoke event: From: Volume Riared VYhiCh Germsrated Black Smoke (If DiNerent From Above}; ~p BgL„ Type of Materials Burned: (Ct,.ck One) GAS: NGts: ,Other: See information from Sediorle A, B, and C above (Cause and Corrective Actlon}. General Weather. Alr Temperature: Vrnnd 3peed/DireCtion: NJ)r1u On.1 nMnm w...wh., wi ..~.....w .....L:r- ,..- __--~- F~ Facility S rvisor FORMS/Flare Irxrdont a114J98 Ver:ion ,z - 2 ?- < cc: Environmental Coordinator, NSK-tit Date Signed (Ertvironmetnal Use Only) Falc Patricia Rafter, ext. 156ti ce NSK Env. Flle: 9.7 FEB 28 '97 13102 907 659 7?12 PAGE.~1 FROMe ENUIRONMENTRL FRX NO s 907 659 7712 83-03-97 07e23R P.01 __ _ GAS olsPOSmoN Time of Occurrence: 9Q.D>~ T.~ MioLtea Qate of Occurrence: o~~ fF1.AFt~ or VENT' 70: {mmldd/yy) ~e selection) ~_ To: 2015 .~,,.,. To: Total Volume: 33. ~~ ut4CF BBL3 To: (JncJUdes Volume flared Which Generated 61eck Smoke, Ji' Iippfiuble.) To: fti7CiS ~+ ~h To: Meter No. (Flare only): f'~~l' t Planned Un tanned (Circle Total Minutes Flared or Vented: ' Venting defined as a rckaaa !o almosprtero. FJenng /e gas /eaWng t-trough Mare tip, (For Qes Ventusg trrerdMts, wqs vn+rhne Qnteed on Gas VeDtir+g Spnsad7heet7 YES ar NO (circle one),) A. Description of Incident: (Check Ona and Circle as Applicable) Compressor Shutdown Prxess upset in section of 9~FAGl~k.YSFMi'7biMJ facility High Tie Line Pressure Flaring for drillsite shutdownlstaKup Flare system testing Other. reRxlTroN ofy ~ ~ o~ S vsrEM _ B. Description of Cause:(CMck One and Circle as Applicable) High ambient tempergfuret Packer fiprip Compressor ereak•In Electricat/instrumantation malfunction Faulty shutdown Equipment difficulties with vibration Other, ~atunva nC ~lU,r_'! Excessive inlet qas rates Facility maintenance Flare valves opened to relieve system overprgsaura C. Action Taken to E:iminate Cause: (Cheek One and Circle as Applicable) Started/restaned Compressor Corrected electricalrinstrumentatlan geducsdAncreased inlet gas rates affun ,~^ Completed flare testing tabilized facility process and operation Fadtity maintenance completed ~F epaired equipmen`t~f icullies`~~ with ~~- / Other. ~rSCoNYlrlatEa 17QRr~yrue Gds ~ltiw~ /rlu e/ BLACK SMOKE Did Incident Cause Black Smoke? Yea: Notified ApEC. {Dale) (Time] (ALASKA DEPT. O~ENVR. CONSERVATION Rep.} RepoK the ioflowfng Infonrratlon to .40fa;C wifhht ?4 hours by telephone (8a7) aa6.6t00 or, iax: (907) 465-S7Z9 Date and Time of black Smoke event: From: Volume Flared Which Generated Bladt Smoke (B DlBerent From Above): M9CF f3BLS Type of Materials Bumed: (Check Onq) GAS: NGLa: _ Other: See informat+on frDm Sections A, B, and C above (Cause and Corrective Action). General Weather: Air Temperature: Wind fipeedlDlrection: F cility Supervi r FQRMS/Flare Incident e/14/96 Veninn ~"~~ ! / cc: Environmental Coordinator, NSK•61 bats Signed (Environmetnal Use Only} Fax: Patricia palter, ext. t5ti6 ca NSK Env. File: 9.7 MRR 3 '97 0730 907 659 7712 PAGE.001 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION • Facility PROCESSING FACILITY #1 ~ ARCO ALASKA, INC. ARUK RIVER UNIT Disposition Volume MCF* 1. Sold 30,502 2. Reinjected 2,222,862 3. Flazed or vented less than 1 hour 3,508 4. Flazed or vented greater than 1 hour (Sup lemental tie tt aired-See 20 AAC 25.235) 50 5. Pilot and Purge 12,178 6. Used for lease operations Fuel Assist 786,399 6 107 7.Other 0 TOTAL items 1 - 7 3,061,606 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: PBU CGF (LSEOR NGLS) 188,453 11. Transferred to: 0 Remarks: Reinjected vol does not include volumes of PBU NGLS squired for LSEOR reflected on line 10 or Na tha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: Title: Date: rorm iv-~+~~ ~icevisea 4iy~~ eaz of D 1/97 *Indicate contribution of each pool to total. Pool Name Code Percent KUPARUK RIVER UMT 490100 100.00% Note: All volumes must be corrected to lpoes~Qre of 14.65 Asia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. .d-? L.G.: LJ 3 :~> ~-. ~~~ i_~ s,. FROMs ENUIRONMENTRL FAX NO s 907 659 7712 81-31-97 06~~fi P.01 FA L'PF~- l • GAS OI~POfBfi10N Date of Occurrence: L " ~7' g~I 7irr~ 000o FLARE r VENT' 211 ~-4 of t7ccurrancQ: zs°a To: '~'L.L{ b ~_ (mm/dd/yy) ~rce Selection) To: To: Total Vaurrw: --~a• b t~ i3BLS To: (l:se/udes Volume flared N?Ych Generated 8fadt Smolw, h Itpp!lcabia.) T0: i4aGaS To: Meter No. (Flare only): ~1-t"~JE7t}A Plamod lann (Girds S cUon) Total Mirwtea Flared or Vented: • VarrMg dai7rWd as a roloaao to arrnoaphsrr. Flanng le gas Ni-~g 81r0upfr Mare tip. (For Caa Ventkp Itxldsnta, stsu voltane erxsnd on Gas Vessang Sproaabhet? YES w NO (cmxo arrs~) a t7eacription of Inciderth (Cheat one and CfreM as AiSplieabN) Cornpressor StiUltiOWn Process upset in section of 61~idt3+K,Y9FltlICQIiVN facility High Tie Llne Presauro Flaring for driitsite shutdown/staRUp Flare system tttstirtg Other: 4~S ~) LC+A~G-- ~vi~ t3. Description of t:ause:(Cheok One srtd Cirale ss Applleabla) High ambient temptrotures PatytQr Redp Comprrtasor &eak•In ElectricaUinstrumentation malfunction Faulty shutdown Equipment difficuMies with vibration Other. ~PS J ~.G-w~- Excessive inlet yes rates Facility maintenance Flare valves opened to rQlivve system overpressure ~~~5 C. Action Taken m ENmlttats Cause: (Check One snd Carols as Appllcsbls) Started/restarted Comprossor Corractod vlactricaUlnstrumentation Reduoedllncreaaed inlet gas ratQS malfunction Completed flaro tasting Stabitixad faCiYty process and operation Facility maintwwtrros completed Repatrod equipment dittkultiQa ~ ith Other: r l~C-SC ~ Did Incident CauaQ Black Smolct!? Ysr. Notified ADEC. (Date) (Timo) (AtJ.19KA DEP?. OF ENVR. CONSERVATION Rap.) the tiono+srhty iv>Ibnnorioa to ADEC sriNsbs ?I hour by bhphetie (Atl7) ~1i6-ffOD or, Fas<: (907) 168-d7Z8 Date and Time of bladt smoke eVenC From: Volume Flared Whk:h Generated etadt Snake (If Different Frntn Above): M9tF BBlS Type of Materials Bumed: (Chock one) GAS: NGLs: ~ Other. yes infomnation from Sections A, B, and C above (Cause and Corrective Action). General Weather: Air Tsmperaturo: Wind 3osed/Dirsatbn: ~_ Fadlity liup teaser FORMS/Flars Inoidsnt 8114/96 Yen~ion -~ ~'-~~ cc: Environmental Coordinator, NSK•61 Date Signed (Etnriranrnetnal use only) Fax: Patrk>ra Rafter, ext. a: NSK Env. File: 9.7 u _~ 1566 ~---~ JAN 31 ' 97 0657 907 659 7712 PACE. 661 ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS CPF 111 JANUARY 1997 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR •1 /27/97 2114-2240 5 0 Unplanned flare due to PSU leak -First stage 'B' UNPLANNED Reset PSU Gas Lift Compressor. TOTAL OVER 1 HOUR 5 0 Flan or Vant Volumaa: Gnatar than 1 hour 5 0 L~aa than 1 hour 3,508 Contlnuoua Aaslst 6,107 Pilot and Purgs 12.178 TOTAL FLAREDNENTED 21,843 CJ