HomeMy WebLinkAboutARCO - FS #2State of Alaska Alaska Oil & Gas Conservation Commission 1999 Facility Report Files File Names Gas Disposition - FS ALASKA OIL AND GAS CONSERVATION COMMISSION -~ FACILITY REPORT OF PRODUCED GAS DISPOSITION ~~ i Facility FLOW STATION 2 Operator ARCO ALASKA, INC. Field(s) EASTERN OPERA Disposition 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 1, l70 4. Flared or vented greater than I hour (Supplemental report required--See 20 AAC 25.235) 0 5. Pilot and Purge 19,038 6. Used for lease operations Fuel Assist 750,024 0 7.Other 0 TOTAL items 1 - 7 770,232 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 358,940 11. Transferred to: CCP 22,363,755 Remarks: I hereby certify that the foregoing is true and co'r~rect~to the byesgt of my knowledge. Signature: 2g„~~.~"~ % ' p/ G / Title: SUPERVISOR Fotm 10-422 (Revised 4/95) ~Month/Year of Disposition TING AREA-PBU Jan-99 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 Official Use Onl --Plano Authocization> I hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date pressure of 14.65 psis and to a temperature of 60 degrees F. Repott due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. 9901 FORM t4422.~ds/FORM 14422 ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS FS-2 January-1999 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS ~ CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR and/or GREATER THAN SMM Over 1 Hour/Over 5MM 0 less 1 HR/Less SMM 1,170 Tofa/ over/under 1 Hr/5MM ~,17~ Pilot/Purge 19,038 Continuous Assist 0 • TOTAL FLAREDNENTED 20,20b ALASKA OIL AND GA5 CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition FLOW STATION 2 ARCO ALASKA, INC. EASTERN OPERATING AREA-PBU Feb-99 Disposition 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 6,595 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 630 5. Pilot and Purge 17,484 6. Used for lease operations Fuel Assist 665,576 2 7.Other 0 TOTAL items 1 - 7 690,287 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 319,331 11. Transferred to: CCP 20,030,673 Remarks: I hereby certify that the fore ing is true and correct to the best of my knowledge. Signature: ~~"'~1 ~ f Title: SUPERVISOR Form 10-422 (Revised 4/95) ,.- , ~~ ~~~_~ ,, l~ ;:~ 9902 FORM 1Od22.~ds/FORM 10-422 obit""'< s,°?~;,~l~cl ~ ~ <x ~,d; a`~iii~ 5 ~t ~a;~l;~vk~eai~: *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 Official Use Only--Flann¢ Authorization. > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ARCO ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS FS-2 February-1999 PLANNED DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR and/or GREATER THAN 5MM 02/19/99 0258-0323 630 Shut down 1803 due to defective instrumentation. UNPLANNED Reduced inlet gas rates. Replaced • 0328-0406 Gas transit system overpressure backing Flow Station out. defective limit switch on Waste Heat EOC made cuts, shut in 5-8, 7-37, 11-b to min. Recovery Bypass. Recalibrated the positioner for the Wast eHeat Recovery inlet louvers Over 1 Hour/Over SMM 630 Less 1 HR/Less 5MM 6,595 Total over/under 1 Hr/5MM 7,225 Pilot/Purge 17,484 Continuous Assist 2 TOTAL FLAREDNENTED 24,711 .. CJ • ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility FLOW STATION 2 Operator ARCO ALASKA, INC. Field(s) Month/Year of Disposition EASTERN OPERATING AREA-PBU Mar-99 Disposition *Indicate contribution of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 PRUDHOE 640150 100 3. Flared or vented less than 1 hour 1,760 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 11,235 5. Pilot and Purge 19,056 6. Used for lease operations Fuel Assist 758,208 60 . Other 0 ........................................................ ........................................................ ........................................................ Offici81 Use t?~ay;ka~tg A;u~iot~2-dt~Jl.~ I to ' ::: TOTAL items 1 - 7 790,319 1. Safety MCF 8. NGL gas equivalent produced 0 2. Lease Use MCF 9. Purchased gas 0 3. Conserv. Purposes MCF 10. Transferred from: CGF 351,510 Commissioner Date 11. Transferred to: CCP 24,043,095 ote: vo umes must a correct to Remarks: pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the I hereby certify that the foregoing is true and correct to e best of my knowledge. Signature: ~ c.. ~ ~ Title: MANAGER month following the month of disposition Authority 20 AAC 25.235. Form 10-422 (Revised 4 ) 9903 FORM 10-422.bs/FORM 10-422 ,. ARCO ALASKA, INC. CONSERVATION ORDER N0.219 GAS FLARING OR VENTING INCIDENTS FS-2 March-1999 DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR and/or GREATER THAN 5MM 03/07/99 0739-1745 6,047 Electrical Instrumentation malfunction. TC 1802 S/D on UNPLANNED • HH Discharge Alarm. TC 1801 was unavailable due to 18,000 maintenance inspection. (Additional detailed information is attached to the flare report,) 03/16/99 03/17/99 03/17/99 03/19/99 Over 1 Hour/Over 5MM Less 1 HR/Less 5MM Total over/under 1 Hr/5MM Pilot/Purge Continuous Assist Series of repairs were done including jumpering the speed switch, replacing tt• speed switch, adjusting the IGVS, replacii the speed probe) and calibration of all pertinent items. 1802 was restarted. 1552-1733 932 Instrumentation malfunction due to failure of IP ComprE UNPLANNED Repaired IP Recycle Valve Actuator and Recycle valve actuator positioner arm (an Allen Screw had restarted 1802. backed out of the arm). (timeline is attached to the flare report.) 0235-0445 1,228 Instrumentation malfunction. Recurring failure of IP UNPLANNED Repaired IP Recycle Valve Actuator and Recycle Valve linkage. The Allen Screw backed out of the restarted 1802. positioner arm. (timeline is attached to the flare report.) 1704-2113 2,358 TC-1802 shut down because of valve positioner malfunc UNPLANNED Dismantled the valve bonnet and did The positioner rod that connects to the actual valve stem repaired internal valve parts. Restarted sheared its connecting bolt, (Additional information 1802 attached to flare report.) 1610-1723 670 11,235 1,760 12,995 19,056 60 Shut down 1802 for STV Anti-surge vavle repairs. There is UNPLANNED Added a missing connector and adjuster no stand-by machine. (Additional information attached to the spring on the IP recycle valve. flare report.) Restarted 1802. TOTAL FLARED/VENTED 32,111 ' Re: Supplementary Information Check • ~ , r Subject: Re: Supplementary Information Check Date: Wed, 17 Mar 1999 09:20:07 -0900 From: Wendy Mahan <Wendy_Mahan@admin.state.ak.us> Organization: doa-aogcc To: EOC Supervisor PRB <P2013@mail.aai.arco.com> Hi Paul, The Flow Station 2 Summary for 3/7/99 looks great. I just have a few questions, though. How much flaring was cut by shutting in the two wells and lowering the Crude Oil Surge Drum's temperature, and when were these actions taken? Also, you said that "the 1802 unit was found to be in good operational condition..." Was an inspection performed prior to taking 1801 down? Thanks, ,o-= CoSdT~M'P < Wendy ~~fE,c.7'n/5 ~kE'~//- ~~o VOtvM£ ~-~~1'e,.3~~, ~~ ~M~ 6L® ~N t ~, G- u ~.~ ~ ~~ ~ Pj o ~ ~-t ~ C~ e1 ~ ;~' ~~.R.~l~ t i~ ~~ ~~~ ~~~~~5 3 /~ ~~~,~ 1 of 1 3/18/99 9:07 AM Supplementary Information Check • • Subject: Supplementary Information Check Date: Tue, 16 Mar 1999 18:02:21 -1000 From: "EOC Supervisor PRB" <P2013@mail.aai.arco.com> To: Wendy_Mahan@admin.state.ak.us Wendy, On 3/7 Flow Station Two experienced an unscheduled outage of the LM-1500 driven STV/IP compressor train 1802 while the 1801 skid was out of service for scheduled maintenance. As you are aware the only way we get out of flare in this situation, until the unit is restarted, is to shutdown the entire facility. We've drafted up this supplemental information for this incident and I wanted to run it past you before we incorporate it into the monthly report data. I'm just trying to be a little proactive here so you don't have to ask for better clarification later. Please let me know if you feel this is sufficient. If so, then we'll include this into the report as is. Thanks for your time, Paul Andrews (See attached file: Flow Two Flare 3.7.99.doc) _~~ ~ ._.~_. ~ __. ~ _ ..._ ~~ _ __._... ~ _~~. _~_ ._.... ~.. _..v .. __~~ ~ _ ~ _,._~ Name: Flow Two Flare 3.7.99.doc Flow Two Flare 3.7.99.doc' Type: Download File (application/msword) Encoding: base64 Description: Mac Word 3.0 i I of I 3/18/99 9:08 AM Summary of Flow Station Two Flaring Event on 3-7-99 At 07:39 hours the Flow Station Two STV/IP compressor, tag #1802, tripped unexpectedly. This upset resulted in one continuous flaring event during the following 10.1 hours. Due to unavailability of the spare compressor train and the increased flaring consequence of shutting down the entire facility to eliminate the relatively low flare rate, the station was forced to flare the process while the unit was troubleshot and restarted. The total duration of the flare was 606 minutes and a total flare volume of 6,047 Mscf. General Information At 07:39 hours the 1802 STV/IP compressor train shutdown on what appeared to be a High Discharge Temperature alarm. The restart was unsuccessful and the Instrumentation Department was called, whereupon a protracted series of repairs began. These included jumpering the speed switch, replacing the speed switch, adjusting the IGV's, replacing the speed probe, and calibration of all pertinent items. These activities covered a time period from 08:15 to 17:45 hours. The entire troubleshooting effort covered nine start attempts during this period. It is important to note that there is normally an available spare compressor train for this process. In this instance, unit 1801 would serve this function. However, the gas generator for this unit had been previously removed for a scheduled 18,000-hour maintenance inspection and had not been reinstalled prior to the 3/7 event. Prior to removing the 1801 gas generator and thus preventing the 1801 unit from acting as a spare, the 1802 unit was found to be in good operational condition and expected to perform satisfactory during the 1801 maintenance duration. This is considered normal practice and due to the high reliability of the STV/IP units does not frequently result in extended flare durations. It is also important to note that two wells were shut into help reduce the flaring at Flow Two. Also the Crude Oil Surge Drum's temperature was lowered and the pressure raised to reduce the flare volumes. 3/16/99 PWA FACILITY: ~ 11" ~ 3 ~l$ FLARE GAS VENTING REPORT ARCO ALASKA, INC. • PRUDHOE BAY/GPMA/KUPARUK Flow Station 2 PERMIT NO. 9473-AA011 Date of Occurrence: ~ ~ dare ^ vent (m /dd/yy) (Check Selection) Total Volume Flared: ~~~MSCF BBLS Meter NO.: (ey Facility) ^ Planned Unplanned (Check Selection) Time of Occurrence: 00_00 2400 Mi From: From: ~7~'39' To: ~c~ To: _ 6O From: To: From: To: From:. To: From: To: Total Minutes Flared: ~j (Lisburne Only -Gas flared was from ^ upstream O downstream (cneck one! (Includes volume flared which generated black smoke ~ ~ o/ TEG contactor meter at LPC) if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) SID T/C~ for TIC SD due to high exhaust temperature Seal oil system difficulties EMERGENCY SHUTDOWN Elecvical / tnstrumentation malfunction Electrical /Instrumentation malfunction at other facility (T8D) Gas transit system overpressure backing CPF/Flow Station out Excessive /insufficient inlet gas rates into facility Process upset in section of facility Flaring for tlnllsite shutdown /startup Flare system testing Faulty shutdown ort Facility maintehance High ambient temperatures. S/D on high vibration Other: ~ a .r ^c c B. Action Taken to Eliminate Cause a ent Recurrence: (Checl and d tribe as applicable) _~ Started / staue /C # _ Compress rain depressured Stabilized facility process and operation Reduced /increased inlet gas rates Repaired equipment difficulties Completed flare testing with Facility maintenance completed Corrected E&I fluctuation /failure Other Corrected E&I fluctuation /failure . at other facility (T8D) Black Sm o ke ~/ + Did incident cause black smoke? Yes: No: kQ (If Yes, continue with this section) .Did incident present a potential threat to human health or safety? / \ Yes: (tf Yes, report to FEC as soon as possible. If No, report to ADEC with 24 hours.) No: Black smoke emitted from source: (enter tag number and description) Notified ADEC by-Fax o Date: Time: Report the following information to ADEC within 24 hours BY FAX (907-269-7508): Date and time of black smoke event: From: To: Volume flared which generated black smoke (if different from above): MSCF Description of steps to minimize emissions: See Section 8, above. BBLS Type of materials burned: Gas: NGLs: Other . General Weather: Air Temperature: Wind Speed/Direction:- Name and phone number of person making the report: Name Phone No. Based on Information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurst nd tom let~e „ v ~ ~~~~ Facility Supervisor / ~ Date cc: EOC Supervisor, PRB 6 (flare gas and black smoke incidents) Field Environmental Compliance Coordinators, PRB 7 (Black Smoke incidents only) PBU/GPMA Field Managers, (Black smoke incidents only) GPMA Operations Engineering Technical Aide, (GPMA reports only - ATO 477) Kuparuk: Field Environmental Compliance Coordinators, NSK 61 (flare gas and black smoke incidents) Updated: FS2 9/98 P:\Grouns\Fnvirnnmonf~nF~~,,,~tc.,:u_r~.... o........:..., c..,_,t___._._ ., .. _. _ . ~ • Summary of Flow Station Two Flaring Event on 3-7-99 At 07:39 hours the Flow Station Two STV/IP compressor, tag #1802, tripped unexpectedly. This upset resulted in one continuous flaring event during the following 10.1 hours. Due to unavailability of the spare compressor train and the increased flaring consequence of shutting down the entire facility to eliminate the relatively low flare rate, the station was forced to flare the process while the unit was troubleshot and restarted. The total duration of the flare was 606 minutes and a total flare volume of 6,047 Mscf. General Information At 07:39 hours the 1802 STV/IP compressor train shutdown on what appeared to be a High Discharge Temperature alarm. The restart was unsuccessful and the Instrumentation Department was called, whereupon a protracted series of repairs began. These included jumpering the speed switch, replacing the speed switch, adjusting the IGV's, replacing the speed probe, and calibration of all pertinent items. These activities covered a time period from 08:15 to 17:45 hours. The entire troubleshooting effort covered nine start attempts during this period. It is important to note that there is normally an available spare compressor train for this process. In this instance, unit 1801 would serve this function. However, the gas generator for this unit had been previously removed for a scheduled 18,000-hour maintenance inspection and had not been reinstalled prior to the 3/7 event. Prior to removing the 1801 gas generator and thus preventing the 1801 unit from acting as a spare, the 1802 unit was found to be in good operational condition and expected to perform satisfactory during the 1801 maintenance duration. This is considered normal practice and due to the high reliability of the STV/IP units does not frequently result in extended flare durations. It is also important to note that two wells were shut in to help reduce the flaring at Flow Two. Also the Crude Oil Surge Drum's temperature was lowered and the pressure raised to reduce the flare volumes. 3/16/99 PWA ;. • Flare Event-3/10/99 To:EOC On 3/10/99 at approximately 7:45 a.m. the IR- 1802 s/d on what appeared to be a High Discharge, Temperature alarm. The, restart was unsuccessful and instrumentation was called,whereupon aprotracted series of repairs began. These included. jumpering the speed switch,replacing the speed switch,adjusting the IGV's,replacing the speed probe,and calibration of all pertinent items.These activities covered a time period from 8:15 a.m. to 17:45 p.m. Please note that the spire compressor IR-1801 was unavailable due to a k hour inspection. The entire flaring event covered ~~._-- some 9 starts and 626 minutes. ARCO ~~ File Calculations Char Date ... R-~.`~ t'1TR# ---HU,.a~u~ I HtsLt--- O~ OIJI~F~EMT ---BLOT RAt~OE--- P~'ia MAME DESOI~iPTiOM ~t~LUE MiMiMOM M~~IMDM CD249 1~10F2~iL FS2 IP COMP 102 NET DISCH D.DD Q.00 0.@0 14490. 1242D. ~ 1~3SO. F1 2 E2E0. 1 L 6E1O. 414. 270. ~@ . MSCF~'D INST. 06=1142 MINUTES Ev ~ r ~ ~a ~;. i i .., _.. ~.r ~ ~~ d t a~~i~0 4 ~, u. $ ~~_,R 8 ~~ ~ 1 ~.~. t t...~ ~ sI x1 r i k -~ i s.~.. r .• .: { d~'y ~~a~~ X11 ~- I ~ b ~~ ',\.,.,,,l. r, ~.t~J ~: ~ ---` ?.,~ ..! '~i ~ _ '~i~ ~' ~i~' ~, ~K k ~. ~: .~ SENT BY= ._ 3-18-88 ; 8~15AM ; r J FLOW STATION 2~ 807 658 5061;# 4/ 5 FLARE GAS VENTING REPORT ARCO ALASKA, INC. ~ PRUONOE gAY1GPMAlKUpARUK FAC1LfTY: Flow Station 2 PCRMIT NO. 9473-AAO~~ OAS DISPOSITION ~~ Data of Occurrence: ~ I 9 ~fWre C7 varrc Timo of Occumanw: ( /dd-yy) (Check Selection) oo_oo a~ Minutes From: O~~s To: o yys = _! 3D • Total Volumes Flxrod: /~-C_.,O Mscr• BBLS From: To: _ From: To: Meter No.: 8 Facil' 1 . _ _ ~ ~~ From: Ta = a rlo (Cheek Solwetion) From: TA: = From: To: a Total Minutaw Fla,wd: ~ 130 (Licbumo Ony _ Gaa parod wsa from ^ uvcowrn ^ downsoea+n lCMaefr Ugal (Induces volume oared wNdl sieneretes olads smOKe. a rl:c wnractw meter al LPCi if app/ieable~ A. Description of Incloont and Cawa= (Check as marry as needed to fully descn0e site Incident) :i~0 T/t;fF fore vrocess u0set In TJC SO due ro nigh exhaust temperature sectron or (aan1V Seal oil 6yswm olmeulaas Flaring for dnllsitQ shutdown r aeorwp EMERGENCY 61•IUTDOV1rN Flare sVStem teetlnp Etachical! lnxtrumemstron meltunWon Foully shutdown on EI@ctntal / Instrumentanon malnrncaon FaONty marmenenoe High am0isnt temperatures et atha+r fadlity (rao) 5/D on high uleraUOn t,~as lransN system overpressure ~'' r: backlog GPFlFIOw SlaUOn out ~'G'.ll 21 wt U (L U Exoeaoi,ra 1 inaufFCent inlet gee r-+Erao into fadary /J 8. Action Taken to Ellminaro GiYee ar10 Frevam Racurrenta: (enack and deerriba •^ rappltceDN) j( StOROd / reslaned T/C # O ~- Stabilized facility prooexs and operetion Co-rO-r+assor / trair- depressured Repaired equipment almculnes Reduces /Increases Inlet gab rates r.iNr Completed Aare teaung Y~ KacYlty malntenanr~ completed Corroetod E81 Auetuation /failure Olt+er: Corrected E8J fluctuation / ftgiltue al other fat9lity (T8D) • Black Smokes Did incident cause tNadt smoke? Yas: No: ~ (If Yee, cor><inue with this ser~ton) Did irutiderd r-resent a pptelttial Threat to human AealVl or satery? Yes; No: (if Yes, report to FEC as goon as possible. if Na report to ADEC wkh Ii4 hour.) 61edt smoke cm'xtcd from couree: (antwr tag number and deu:criplian) Notifiwd ADEC by Fax o D#to: Time: RaOOrt the folbwkt0 ktfotmatbrt to ADEC within 2411oufs BY FAX 1'807-269 75091: Date and time of blank smoke arerre Frvm: To: Volume flared which generated blade smoke (if diHerer+t from Above): MSGF 13845 Description o(ateps to minimize emrs6lons: Sao Section H. eDOYe. Type Of metenera DurnAd: Gas: NOLa: Other: t3eneral Weather: Air Temperature: Wind Spe4d/Dlrwetion: Name and phone number of p4rreon making the reporL- Name Phone No. Based on infonnatlon and belief formed after reasonable Inquiry. 1 certify Thai tt+e slalerr~nts and information in and attal~ted to this doeumont ere we, eccura~~nd complete. Faelllly Supervisor G/h ~ 1 rnt'~Q/V~~ oar 3 ~~8~~99 rx: EOC Suporviaor. PRB a (Aaro gas and black smoko incidents) Field Environrnorrtal Compliance Coordinators. PR9 7 (81a0k Smoke incidents only) PBIJ/GPMA F'lels Managers. (BIaCk smoke intxdeMS Dray) GPMA Operations Engineerivlg Technical Aide, (CPMA reptxts only - ATO 477) Kuparvk: Field Environmental Compliance Coordinators. N5K 61 (hare Qas and black smoke incidents) • Flare Event Summary FS2 1802 IR Turbine/Compressor 3/17/99 02:35 Hours The following summary is a timeline of 1802 T/C shutdown which occurred on3/16/99: Note: There is no spare Turbine/Compressor available at this time. TIME EVENT 0235 1802 Turbine /Compressor shutdown on similar indications of 3/16 shutdown, IP Compressor High temperature. Suspecting an IP Recycle recurring failure, operator immediately found the valve to have the Allen screw backed out of the positioner arm of the valve actuator. 0245 Instrument technicians called out to the facility to repair the valve. 0420 First start of 1802 successful. 0445 1802 on line and off flare The total duration of the flare was 130 minutes and the total flare volume of 1,228 Mscf. SENT BY~ Date of Occurrence: 3-18-99 9~13AM ; y Ft.ARE GAS VENTING REPORT ARCO ALASKA, INC. ~ PRUDH~E BAYIGPMA/KUPARUK FACILITY: Flow Station 2 1j~ PERMIT NO. GAS DISPOSITION o;3llcs ~~ ~ ^~r (mmlaoryy) (Check Sdcation) Total Volume Flsrod: ~j3Z MSCF BB~S Meter No.: B Faclll ~ ~~ 70 (ChQCk Swlaction) From: Frpm: From: From: From: From: Total Mlnubu Flarwd: ~ (L.iaDymc Only - Gac Nnrad rvOS nom ^ upsacarn ^ aowncawam !L'haok Oxl of TEG eonaeror meter at ~C) A. Description of Ilttldent end Gauss: (Cneck a9 marry ea nesdad to fully describe the Inclderrt) S1D T1C>Y iar TIC SD Out to hign exhaust Iamperalure seal system oitr„ylliax EMERGENCY SHUTOt)wIV ^~- E:IaCVrcel I Inatrumenranon rrwduncaion Eloctriwl f Irolnrnonterlon malfunction al pth.r IsaliW (T&D) Gas transrc sYslem overpressure batldnq CPFIFIow Stollen art Exosunre I insufficient inlet qas rates alto taalily (lndudes vorume Qared wnlcn r7enerared DIaCJr smoKe. if 6AAi~ableJ Pt~ESS upset m seaiat of faciiiy Flaring rot annsrca snutaown / slartuo Flew atratsrn tenting Faulty shutdown on Fatality mamt9nenee High ambient temperatures. ~-' S1D on high v~rofion ~~ Other: ~-1~tj?~=`-°~=~~R.. 'Psi ~. r .!` ~ / ~ ~ At++ sarrd~- 'F~cS ~ ~r-r ~~ au. ~~ 907 659 5061;# 1/ 5 w . ~Y~ 3r~~~~/ 9473-AA01 ~ Time of Occurnence• 00_00 2600 MI~tt3 1 S : ~Z To: ~~- _ ! a t T0: - To: _ _ ~- To: _ To: _ ~, B. Acaon Tukon m Eaminato Coosa aria Prevent Raeurronee: IC1+aelr. and doseriDe ss sppilcabls) ~ Started !restarted T!C a _1hg - IS3o2- Ctunbrassar /train deprescured Reduced / incrcaxd inlet 9aL rstea Completed stare testing Corrected E81 fluetuauon / failure Gorractea E81 nutxuaaon ~ railurz at odtcrfacility (T80) Did incident cause blade smoke? Yes: No: l~ Die incident present a potential Ihrvat to human healtli or ~afcty? (If Yos, report to FEC as soon as posslbla. M No. report to ADEC with 24 hours.) Blade smoke emitted from nourCA: Stabilized radliry process and opertltion Repaired equipment difficulties with Fagllty matntenanCe completed (If Yes, cont~tue with this section) Yes: No: (enter tag number aria oescrtpaon) Notified ADEC by FaY o Gate: Time: Report trio bllawlrrg bdom,rtlon a ADEG M,Ifhin as hours yt3 FAX 19o7ase-7606): Det®and iim® of blook smoke event: From: To: volumes flared uriiich generated blade smoke (If dlRerent frortt above): MSCF BBLS OeSCnoUon or steps to miMmlze emissions: See »eCtlon B, aboro. Type of materials boned: Gas: NGLs: Other: Gonorol tNeadrer. Air Temperature: YVII10 Soeed/Direction: Name and phone number of person tttiaking ute report. Nartw Phone No. Based on infomwlion and belief formed after reasonable Inqurt/. 1 cerpty that the stafemems ens mtormauon m ono aaat:neo to l document are true. accura ertd COmplets,.... ~ p/q ~- o.~ 3 ~ O Facility Supervisor s' cc: EOC Supervisor, PRB 6 (flare gas ono b cK smoke mudents) Flelo Environmental Compliance Goordinacoco. PR9 7 (Black Srrwke incidents onty) P8U/t3PMA Field Monagorc. (Blade amok¢ incidents only) CGPfW4 Operallons Englnaering Technir~t Aide. (GPMA reports only - ATO 477) Kuperuk: Field Environmental GomptlanCe Coorainatorts•, NSK 61 (flare gas and block smoke incident9) FLOW STAT l ON 2-' Upaale0: F82 9l9B P:-Group6-EnvironmenlahFermx~kll.Gaa RepoAing Fonts\Templabe pn Line Flare Gag Vengttg Form 11-861.1U6 .. • • Flare Event Summary FS2 1802 IR Turbine/Compressor 3/16/99 15:52 Hours The following summary is a timeline of 1802 T/C shutdown which occurred on 3/16/99: Note: There is no spare Turbine/Compressor available at this time. TIME EVENT 1552 1802 shutdown on IP Compressor Discharge High Temperature. Subsequent operator response and investigation found that an Allen screw had backed out of the positioner arm of the valve actuator for the IP recycle valve. Instrument technicians were called and the part was repaired. 1700 First start attempt failed due to STV Thrust Bearing High vibration. 1730 Second start successful and 1802 T/C came up to idle speed. 1733 1802 fully loaded and off flare. The total duration of the flare was101 minutes and a total flare volume of 932 Mscf. SENT BY~ r3-18-89 8~14AM FLOW STATION 2~ 807 659 5061;# r3/ 5 ..- FLARE GAS VENTING REPORT ARCO ALASKA, INC. ~ PRUONOE BAYIGPMAIKUPARUK FACILITY: Flow Station 2 PERMIT N0. 94i3-AA011 GA9 DISP031TION Date of Oeeurr't,nw: -~-- L~ Flare n vvx Tlme of Occurrence: (rnm/d IYyI (Check Selecdon) ~ O~o:00~j~ 2aao Illtl_ nub ~~~~'~~'QQ From: ~~-"~~ To: '..11 13 = Total Volume Flared: /Sr1rZ~MSCF BBLS From: To: _ From: To: Motor No.: (ey Facility) 4 plero+eo Unplanned From: To: _ ~~ - ~_ (Check .SeleGion) From: To: • From: To: = Total Mlrwres Flpred: v .l X17 (LISPUme Only - Qaa Hared wee loom ^ upvnim Cl dam,csoarn fOrwc~ oral (Includes volume tlarod which gonerated black RniOI[e, +--•r o/ TEG conraeror meter al LPC~ if applrcaLle) A. t]eacriptlon of Incldont an0 Cause: ICheck as marry as needed to tully deacrlba rho Incident) Sn7 7lCil for Procelu~upxelin TIC SD due to high exhaust l9mperature section or fagllty Seal ail system ElfltcUllles Flaring for enllaite shutdown r sOerWp EMEROENC7 3t1UTpOWN Ylaro eriiem ue9ung ~oekieal / Inat-umentsaon meliunation Feulry shutdown on EIeeVICAI ! Inst-umenwtion maHUnttlon Fadllty mamleranta! High amlaelli tempereturea. at tnher facility (TB,p) S/D high vibr i Gaa vensit system overpressure ~ O oawdn0 cvF/Flow station out EXt:e9SIVe / InsumcJenl Inlet gas torso mto iadlrty B. Action Taken 1D Ellminew Cause aed Prpvenl Recumanee: (Check and dssulDs as itpttllCabM) Sterteo ! restaRea T/C # StobAizcd faciliy process and eperstian Compressor / train depreasured Repaired equipment tllfflCUllles Reduced / inCrylatpd inlwt gas races Vdlffl Comple[et1118re [eSUng Facility maintentutce wmpleled Corroded ESI fiuctuaUon ! failure Other. Corroded E81 fiudusdon /failure at other faeifily (T&O) . Black Snooks Did incident cause black smoke? Yes: No: ~ (II Yea, wnluwa wilts this section) Did incident present a polentlal ehreat to human health or rafely~ Yes: NO: (I(Yos, report to FEC as soon as posaiblo. If No, report to ADEG wire 24 hour6.1 Bladt Smt7ke errgtte0 UOm source: (cntcr tog number and dcxription) Notified AnEC ray Fex o Datc: Time: Report tl+e foUowing Informwtlon ee AOEC wldrln xa hours BYe a>< (9t17.ZB9.tS08): Pate and lime of black smoke event From: To: Volurrle tlaretl wnltxt generated black smoke (i! dHferem from above): MSCF eBLS Qet:CNption of steps to minimix¢ erniesions: See Section B, a~eve. Type pf materials ttumed: Gas: NGLS: t]tftar: General Weather: Air Temperature: Wetct 3peed/Oirection: Namts artd phone number of person mokirtg the rcpoR: Name Phone No. Based on iniomtalit)n an0 belief formed after reasonable inptnry, I certify that the statements and informadon in and attached to ihi9 QoWment ere AUe, aCCUra t>d comp) ~ Fatality Supervisor / , m Dab 3'I 8/99 C~ EOC Supen-faor, PRB 8 (flare gas and b aclc smoke inciderrta) Find Environmcnial Complianoo Coord'nstor~. PRB 7 (Black Smoke incidents only) PBU/GPMA Fioki Marlag4rr;. (Black smoke inddents only) GPMA Operations F.npineerinSf Technidal Aida, (GPMA tepees only - ATO 477) Kuparuk: Field Envirvnment6l Complierlcc Coordinotora, NSK 81 (flare gsa and black smoke incidents) Updated: FS2 9/98. P;1GroupslEnvironmentaRFonns15p11hGas ReDOrting ForrttslTemplete On Line Flare Gas YenGng Form 8-Bbl.xls ,. • Flare Event Summary FS2 1802 IR Turbine/Compressor 3/17/99 17:04 Hours At approximately S:OOpm on Wednesday 3/17, the IR Turbine/Compressor 1802 shut down on an indicated High discharge temperature. Upon inspection by the technicians, severe valve positioner damage was found on the IP compressor recycle valve. The positioner rod that connects to the actual valve stem had, this time, sheared it connecting bolt. This required a dismantling of the valve bonnet and extensive reworking of the internal valve parts. These repairs required approximately four hours. When complete, 1802 came on line with the first start and we went off flare The total duration of the flare was 249 minutes an a flare volume of 2,358 Mscf..