ALASKA OIL AND (;AS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I Facility
FLOW STATION I
I Operator
ARCO ALASKA, INC.
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
16.135
-
4. Flared or vented ~reater than 1 hour
(Supplemental report required--See 20 MC 25.235)
7.639
5. Pilot and Pur~e
28.508
6. Used for lease operations
807.454
149
Fuel
Assist
7. Other
TOTAL items 1 - 7
~ 859.885
!.'.)
~.,
....-
Õj ,
º c:-
~ ):> n 0
~ Ç) :z (
n1l)
:::rU) --> n
cO 0
;;0 -..
u:.1 ='
(tI¥I --> <
0 r.s:.¡.
0 u:> rL
3 en 274.737
3 n
¡j)'
(I)
õ'
;:;¡ 62,180,514
8. NGL ~as equivalent produced
--
9. Purchased gas
to. Transferred from: CGF
11. Transferred to: CCP
Remarks:
I hereby certify th~the f~oing is true and correct to the best of my knowledge.
Signature: ;1 ~ - - Title: SUPERVISOR
Form 10~K~~ised 4/95)
I Field(s) I MonthlY ear of Disposition
EASTERN OPERATING AREA-PBU Dec-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
Official Use Only--Flaring Authorization> 1 hr.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
DATE
TIME
VOLUME MCF
FLARING EVENTS LESS THAN 1 HOUR
12/01/95 1445·1455 3
12/10/95 1216·1233 72
1747-1825
e 12/11/95 0500-0505 80
0650·0700
12/11/95 1251-1315 1,137
12/13/95 0200·0255 11 ,371
12/27/95 1810-1900 3,472
TOTAL UNDER 1 HOUR
18,135
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
e
12/11/95
0910-1010
TOTAL OVER 1 HOUR
7,838
Flared
Pilot/Purge
Continuous Assist
TOTAL FLARED
7,639
23,774
28,508
1.!J
52,431
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION '1
DECEMBER 1995
DESCRIPTION OF INCIDENTS & CAUSE
Normal stop 1802
1496 building heater shut down twice. Upstream
control valve leaking through and lifting PSV
Shut down TIC 1804 to repair F32AV
Electricallinstrumentation malfunction.
CGF compressor shutdown.
PLANNED
UNPLANNED
ACTION TAKEN TO EUMINATE CAUSE
PLANNED Completed lIaring after normal stop.
UNPLANNED Stabilized facility process and restarted heater.
UNPLANNED CompressorArain depressured. STV flare valve
repair. Bad internal.
UNPLANNED Corrected E&I fluctuation/failure. Flare valve
set point not matched to process variable.
UNPLANNED Wells choked to minimum (5-5,7-14,7-26,
1-16,2-32). CGF compressor restarted.
CGF lost tandem due to a leak. Flared off the Annex to UNPLANNED
men any ice on the flare ignitor assembly.
CGF lost a tandem compressor #3,1885
C',
~1
~
~,
» c,
;::!iJ.J
<..-, {f'J
go
.....0
~='
(t>¥I
(')
o
3
:3
~.
õ'
;;¡
C-
J>
z
-.J
-'
~
ø
š (
f
n
<
f....·
t ,
a
Shut in wells 2-17, 5-6, 5·16, 5-23, 2-2,
2-5, 2-4, 5-9, 1-6, 1-23. Completed flaring.
UNPLANNED Shut in 13 wells. BPX Shut in 400MM gas
CGF gave 1885 Tandem 2 starts-both failed.
Shut in wells on EOA after 2nd start - WOA
cut 400MM already.
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I Facility
FLOW STATION 1
I Operator
ARCO ALASKA, INC.
Disposition
1. Sold
2. Reiniected
3. Flared or vented less than 1 hour
e
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
Fuel
Assist
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
e
Rt:CEIVt:.u
DEC t ~ 1995
Alaska Oil & Gas Cons. COmmission
Anchor3QØ
9. Purchased gas
to. Transferred from: CGF
11. Transferred to: CCP
Remarks:
3.976
28.203
646.978
4.368
683.643
255.754
54,744,761
I hereby cerúfy that the foregoing is true and correct to the best of my knowledge.
I C _~)
Signature:.~_i"¡-Æ..~;'? /" .,<,--------Jitle: SUPERVISOR
Form to~ (Revised 4/95)
I Field(s) IMonth/Year of Disposiúon
EASTERN OPERATING AREA-PBU Nov-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
118
Official Use ()nly--Flarin~ AULhnru.aLion > 1 hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
DATE
VOLUME MCF
TIME
FLARING EVENTS LESS THAN 1 HOUR
11/04/95
0558-0617
594
e
11/05/95
38
0237-0258
11/07/95
2240-2255 115
0000-0007 26
1130-1140 5
11/08/95
11/09/95
11/10/95 1541-1542 451
1547-1548
11/11/95 1446-1501 158
11/11/95 2148-2153 80
e 11/20/95 0300-1456 625
(Intermittent 23 min.)
11/24/95 21 50-2206 1.866
11/24/95 0845-0848 8
11127/95 0945-1305 4
(Intermittent 11 min.)
11/27/95 0840-0935 6
(Intermittent 12 min.)
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION #1
NOVEMBER 1995
DESCRIPTION OF IfCIDENTS " CAUSE
Instrumentation malfunction. TIC 1801 dropped
oft line due to GG hi vibration. Replaced GG
vibration monitor.
Instrumentation malfunction. Process upset in
produced water section 01 facility. False HHHL in
dirty water tank.
TIC 1804 shutdown for combustion inspection
and instrument PM.
TIC 1804 shutdown for PM.
Liquids accumulated in 6th stage backup flare.
PLANNED
UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
UNPLANNED
Restarted TIC 1801.
UNPLANNED Stabilized facility process and operation.
PLANNED
Compressor depressured.
PLANNED
Compressor depressured.
PLANNED
Increased purge gas flow into line to assist
burning of liquids. Changed purge gas
supply from residue gas to field fuel gas.
Excessive inlet gas rates into facility. UNPLANNED Reduced inlet gas rates.
Electrical/instrumentation malfunction. UNPLANNED Corrected malfundion.
TIC 1804 emergency shutdown due to seal oil UNPLANNED Compressor depressured.
system difficulties.
TIC 1804 purge & leak check alter seal oil repairs. PLANNED Purge & leak check completed.
LPS backed out of flare. UNPLANNED Shut in 15-7 and 2-5.
Shutdown 1804 for inspection & main!. vent system. PLANNED Compressor depressured.
3 aborted starts on 1802. 1 normal shutdown on 1801. UNPLANNED Correded E&I fluctuation/failure.
The turbine would not complete a start sequence.
RECEIVEU
6 aborted starts on 1802.
The turbine would not complete a start sequence.
OEC 1 8 1995
Alaska Oil & Gas Cons. Commission
Anchorage
TOTAL UNDER 1 HOUR
3,976
UNPLANNED Corrected E&I fluctuation/failure.
DATE TIME VOLUME MCF
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
11/04/95
e
TOTAL OVER 1 HOUR
Flared
Pllot/Purge
Continuous Assist
TOTAL FLARED
e
2210-2325
118
118
4,094
28,203
Yü
36,665
RECEtVEU
OEC 1 8 1995
Alaska Oì & Gas Cons. Comnission
Anchorage
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCÐENTS
FLOW STATION #1
NOVEMBER 1995
DESCRIPTION OF tlCIDENTS & CAUSE
Instrumentation malfunction. Process upset in
produced water section of facility. False HHHL in
dirty water overflow lank caused produced water
OSD.
PLANNED
UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
UNPLANNED Slabilized facility process and operation.
Repaired equipmenl difficulties.
e
e
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I Facility
I Operator
ARCO ALASKA, INC.
FLOW STATION 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
1,556
4. Flared or vented greater than 1 hour
(Supplemental report requirednSee 20 AAC 25.235)
28,639
5. Pilot and Purge
23,277
6. Used for lease operations
Fuel
Assist
735,149
1.586
7. Other
TOTAL items 1 - 7
790,207
8. NGL gas equivalent produced
9. Purchased gas
\'"
~;':
¡ '. ~ ì... í
.1
'4 t....
fU"} V '\ \
1 \..þ '. \'/ ...)
¡~:-:=1j
to. Transferred from: CGF
240,106
AJaska £. Gas ÛJ'''~
Anc~o, '~g~
52,311,045
11. Transferred to: CCP
Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
./J
( , .
Signature: \ / .. L£:. . Title: SUPERVISOR
Form lO-1~~Ýised 4íJS[l '--0"'-..---
- ..;
I Field(s) I MonthlY ear of Disposition
EASTERN OPERATING AREA-PBU Oct-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
.---.....-
()ffid~11 Use ()lIly--Fl~lril1g AUlborilaLiol1 > I hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
DATE
TIME
VOLUME MCF
FLARING EVENTS LESS THAN 1 HOUR
1630-1640
3
10/6/95
10/12/95
e
TOTAL UNDER 1 HOUR
0001-0100
1,553
1,556
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
} 10/3/95
)
10/3/95
10/3/95
."---
1 0/4/95
e
1019/95
-...-.
10/11/95
10/12/95
--c-------
"vNy
TOTAL OVER 1 HOUR
Flared
Pilot/Purge
Continuous Assist
TOTAL FLARED
0100-0430 181
0100-0230 1,750
0400-0800 200
1520-1830 2,572
0606-0941 5,876
2259-2359 868
0750-0923 17 ,192
28,639
30,195
23,277
un
55,058
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION .1
OCTOBER 1995
DESCRIPTION OF INCIDENTS & CAUSE
Shutdown TC 1802.
Shutdown TC 1801.
VJ:Rt\r 4¡~
/
Depressured Commonline 58, 5D, for repairs at
DS5 Manifold building. . ~.bv~~ 7;J(L V
Depressured the Annex for repair. ~~
-..--
""""1....- . Annex Regen. stripping gas
to flare.
Shutdown TC 1802. Electricallinstrumentation
malfunction.
PLANNED
UNPLANNED ACTION TAKEN TO EUMINATE CAUSE
PLANNED Started 1801.
UNPLANNED Restarted 1801.
PLANNED
Depressurlng completed.
PLANNED
Depressurlng completed.
PLANNED
Depressurlng completed.
UNPLANNED
Restarted 1802.
ê~,q'N-J
/
TIC Shutdown due to high exhaust temperature. UNPLANNED Restarted 1801. Moore Card for IP Compressor
Instrumentation malfunction. Rx.PL V¡,¡s A discharge High temperature replaced.
" A.... 'kn ø.JJ ~ 6"' 4.z..s 0
TC1801 SID due to instrumentation malfunction. UNPLANNED Restarted 1801. Vibration Shop replaced
vibration transducar.
Shutdown T/C 1803.
'-
r
,". ï...~~' 'jJ i..,
;",
;\iask£1
(1 Eas Cims.
Anc!'!orage
UNPLANNED Restarted 1803 TIC.
..
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I Facility
FLOW STATION 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
e
I Operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
e
9. Purchased gas
10. Transferred from: CGF
11. Transferred to: CCP
Remarks:
Fuel
Assist
~ \
v
'. (. .. L. I .. t:
OCT 'I .. '\'0;;!\
I IV""'....V
A\aS\9. Oil ?, Gas Cons. ~omm¡ssiQn
. >. Anchorage
73,215
31,133
647,751
508
752,607
238,067
45,839,148
I hereby certify t!!t the f~oing is true and correct to the best of my knowledge.
Signature: . y. .n~ ~ - Title: SUPERVISOR
Form lO~Kevised 4/95)
Field(S) I MonthlY ear of Disposition
EASTERN OPERATING AREA-PBU Sep-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
o
ŒlïciallJsc ()nly--Flari!~lL:~~!!!!!!~i",uli()n > I hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION '1
SEPTEMBER 1995
DATE
TIME
VOLUME MCF
DESCRIPTION OF INCIDENTS & CAUSE
PLANNED
UNPLANNED ACTION TAKEN TO EliMINATE CAUSE
FLARING EVENTS LESS THAN 1 HOUR
eOTAL UNDER 1 HOUR
o
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
09/11/95 0430-0800 3,000 Depressure Artificial Lift Line. PLANNED Completed depressuring.
09/11/95 0700-1000 52,486 Raring for FS1 shutdown and restart. PLANNED Restarted FS1.
1600-2359
09/11/95 1050-1135 2,442 Restarted flow through Annex. Flaring necessary to PLANNED Increased flow rates to Annex to correct poor
1210-1230 Correct dew point problems. dew points.
09/12/95 0001-0300 3,704 Insufficient inlet gas rates into facility. 1802 STY UNPLANNED Increased inlet gas rates.
Compressor would not load at low rates.
09/12/95 1055-1130 3,663 Rared during restart of FS1 Annex. PLANNED Stabilized facility process and operation.
1205-1230
09/13/95 0814-0930 816 Relief lifted 4947 heater module fuel gas to heaters. UNPLANNED Increased firing rates on heaters in 4947
e 1601-1804 Assist gas for flaring. Module. Assist gas valves closed.
09/13/95 0814-1340 90 Relief lifted 4947 heater module fuel gas to heaters. UNPLANNED Increased firing rates on heaters in 4947
1.601-1804
09/19/95 0908-1356 7,014 Shutdown T/C 1802 due to high exhaust temp. UNPLANNED Ambient temp bias sensor was cleaned. No
(Black smoke event) spare compressor available. Restarted 1802.
TOTAL OVER 1 HOUR
73,215
Flared
Pilot/Purge
Continuous Assist
73,215
31,133
§.ll
TOTAL FLARED
104,856
e
e
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
I Operator
ARCO ALASKA, INC.
FLOW STATION 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than I hour
25,396
4. Flaréd or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
66,711
5. Pilot and Purge
32,4 70
6. Used for lease operations
655,192
1.511
Fuel
Assist
7. Other
TOTAL items 1 - 7
781,280
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from: CGF
250,715
11. Transferred to: CCP
44,871,798
Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: é(~r.. - - Title: SUPERVISOR
l'orm lO~~;ViSed 4195)
I Field(s) MonthlYear of Disposition
EASTERN OPERATING AREA-PBU Aug-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
Official Use Only--Flaring Authorization> 1 hr.
o
1. Safety MCF
"'
, ,
2. Lease Use MCF
3. Conserv. Purposes MCF
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
DATE
mE
VOLUME MCF
FLARING EVENTS LESS THAN 1 HOUR
604
08/02/95
08/18/95
e
08/19/95
08/20/95
08/25/95
TOTAL UNDER 1 HOUR
1939-1945
2301-2400
8,333
0000-0054
7,732
1139-1 223
8,543
0411-0449
184
25,396
e
08/02/95
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
2030-2359
1,842
08/02/95
08/03/95
08/19/95
08/21/95
2030-2230 1,767
0202-0759 8,893
0305-0445 12,226
2224-2342
9,750
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION #1
AUGUST 1995
DESCRIPTION OF INCIDENTS & CAUSE
PLANNED
UNPLANNED
Flared lor valve mainl. Unloaded 1804 to close PLANNED
discharge block valve. Allempting 10 seal valve body
seals to allow replacemenl 01 valve slem venl wla plug.
1803 TIC shutdown. No indication why the turbine
shuldown.
UNPLANNED
1803 TIC Shuldown. No indication why the turbine
shuldown.
UNPLANNED
Shutdown TIC 1885. FS-1 flared lor CGF due 10 1885 UNPLANNED
TIC shutting down.
Shutdown 1805A Vent Gas Compressor lor discharge PLANNED
valve replacement.
STV 1802 compressor surge control 1802. Surge UNPLANNED
control valve unloading compressor due to low Ilow
during repair 01 LPS compressor 1804 valve repair.
1804 compressor electrical problems in control panel. UNPLANNED
TIC 1802 shutdown on a lalse gas generator high UNPLANNED
vibration.
1803 TIC shutdown. On indication why the turbine UNPLANNED
shut down.
1803 TIC shutdown. On indication why the turbine
shut down.
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
Increased 1804 compressor speed to reload.
Maintenance corrected IGV lault so turbine
could be restarted. Instrument techs
Iroubleshooting lalse shutdown.
Maintenance corrected IGV fault so turbine
could be restarted. Instrument techs
Iroubleshooting lalse shutdown.
Reduced inlet gas rates. FS-1 reduced chokes
on wells 2-18,1-16, 1-34,2-11,2-21,
and 7-28.
Restarted 1805A Vent Gas Compressor
R' l:.. ~ ;/ i: D
SEP 1 8 1995
"
. ,
Alaska Oil & Gas Cons. Commission
Increased rates alter valve repair:' t Anchorage
Well 1-10 shut in 10 stop flaring until
1804 reloaded.
Repaired vibration probe and restarted 1802.
9 allempls to reslart turbine.
Restarted 1803 aller repairing waste heat
dampers limit switches. Continued trouble-
shooting Ialse turbine shutdown.
Restarted 1803 aller repairing waste heat
dampers limit switches. Continued trouble-
shooting false turbine shutdown.
DATE
08/25/95
TIME
2038-2340
VOLUME MCF
31,597
08/25/95 0959-1329 197
08/25/95 1330-1620 161
e
08/27/95 0335-0448 278
TOTAL OVER 1 HOUR
66,711
Flared
Pilot/Purge
Continuous Assist
TOTAL FLARED
e
92,107
32,470
1.ll1
126,088
ARCO ALASKA, INC_
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION #1
AUGUST 1995
DESCRIPTION OF INCIDENTS & CAUSE
4942 TEG Regeneration Skid Reboiler shutdown on a
false high temperature. Reboiler would not restart
alter several attempts.
PLANNED
UNPLANNED
UNPLANNED
Shutdown 1805A Vent Gas Compressor for discharge PLANNED
vent replacement
Shutdown 1805A Vent Gas Compressor for discharge UNPLANNED
vent replacement. Unplanned work delays.
Shutdown Drillsite 18 and depressured common lines PLANNED
188 and 18D for module tie-in work. (Rolling start-up
blinds)
ACTION TAKEN TO ELIMINATE CAUSE
Moved common lines 28. 2D. 2E, 58, 6E, 78,
7D, 15D and 188 out of 4942. Pinched chokes
on 22 wells then shutdown module 4942.
Restarted 1805A Vent Gas Compressor
Restarted 1805A Vent Gas Compressor
Completed Drillsite 18 tie-in work
"
. ,
State of Alaska
Memorandum
·1j.4
To: The Commissioner~L
eÞ-
December 27, 1995
11II""
From: Wendy Mahan
Subject: FS 1 flaring event, August 19, 1995
Flow Station 1 compressor TIC 1803 shutdown on August 19, 1995 for no apparent
reason. The compressor was restarted after repairing the waste heat dampers limit
switches. 12,226 mcfwere reportedly flared from 3:05 to 4:45 a.m.
I spoke to Marty Scheerer, EOC specialist, on November 28 about the event. Nothing
was done to minimize flaring during this event. He could not give a reason why
production wasn't shut-in to minimize the flaring. He felt that since it was early in the
morning the operator probably didn't want to wake a supervisor and may have also
though the event wouldn't last over an hour. I sent a letter to John Minier, EOC
supervisor, also on November 28, 1995 asking him to submit additional infonnation by
December 15, 1995. He has not responded.
I recommend that the gas flared from 4:05 until 4:45 be declared waste, estimated at
4,890 mcf.
e
.
.,.,
e
~;;'¡rj" ¡'~: ;?, j' ¡::,~. f .J :'
ALAS~ QIL A.ND GASCONSER~A.TIONCOMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
FLOW STATION 1
Operator
ARCO ALASKA, INC.
I Fie1d(s) MonthIY ear of Disposition
EASTERN OPERATING AREA-PBU Jul-95
Disposition
*Indicate contribution of each pool to total.
1. Sold
o
Pool Name
Code
Percent
2. Reinjected
PRUDHOE
o
640150
100
3. Flared or vented less than 1 hour
720
4. Aared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
17,970
5. Pilot and Purge
32,371
6. Used for lease operations
Fuel
Assist
585,870
2.077
7. Other
. .
Official Use Only--Flaring Aulhoriza~on > I hr.
TOTAL items 1 - 7
639,008 1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
253,479
Commissioner Date
39,395,620
8. NGL gas equivalent produced
9. Purchased gas
to. Transferred from: CGF
11. Transferred to: CCP
Remarks:
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: V~ t - , Title: SUPERVISOR
t"orm 1O-4~e~~Sed 4f)5)
c
0
"ëii
en
~ 1'ê
I.C') e
....W 0
t;f"> c.;)
t;f"> cñ CD
" ..- C)
c e
co 0
c.;) 0
.I .-- CI) '5
cu ~
(.!) c.o
:::> c¡:S
~ « 5
~
~
;;:
MCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCÐENTS
FLOW STATION .1
JULY 1995
PLANNED
UNPLANNED
DATE
UtE
VOLUME MCF DESCRIPnON OF INCI>ENTS & CAUSE
FLARING EVENTS LESS THAN 1 HOUR
07/24/95
0330-0333
80
e 07/24/95 1737-1740 235
07/26/95 0332-0352 217
f .\
07/27/95 0753-0806 108
07/31/95 1745-1750 40
07/31/95 0200-0205 40
TOTAL UNDER 1 HOUR 720
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
e
07/16/95
2,442
2040-2150
07/22/95
ACTION TAKEN TO ELIMINATE CAUSE
Shutdown TIC 1803 for maint. to replace thermowells
on compressor suction piping. Normal stop, then
depressured compressor case.
PLANNED
Reduced inlet gas rates.
2 starts on TIC 1803. Volume represents unit purge PLANNED Start sequence complete.
during start-up. WHR purge (waste heat recovery)
Shutdown TIC 1804 for maintenance to replace PLANNED Reduced inlet gas rates.
thermowells on comp sudion piping. Normal stop
then depressured compressor case.
Slugcatcher overpressure due to choke problems at DS12. UNPLANNED Reduced inlet gas rates.
TIC 1804 purge & leak check aller upgrade tie-ins. PLANNED Purge & Leak check completed.
TIC 1804 purge & leak check aller upgrade tie-ins. PLANNED Purge & Leak check completed.
Flared Annex for CGF Booster 1802 shutdown.
PLANNED CGF Booster 1802 back on line.
0711-0910
15,528 Eledricalllnstrumentalion malfundion at other
? - facility (!!p) CGF 1885 TIC shutdown on a false
sudion scrubber high level shutdown.
UNPLANNED Corrected E&I failure at other facility (T&D)
CGF restarted 1885 T/C.
TOTAL OVER 1 HOUR
17,970
Flared
Pilot/Purge
Continuous Assist
TOTAL FLARED
18,690
32,371
2....Ul
53,138
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
FLOW STATION 1
I Operator
ARCO ALASKA, INC.
Disposition
1. Sold
2. Reinjected
e
3. Flared or vented less than I hour
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
14,607
5. Pilot and Purge
26,507
6. Used for lease operations
Fuel
Assist
620,089
1.770
7. Other
TOTAL items 1 - 7
663,364
8. NGL gas equivalent produced
~: , ^'
, nï
R" \;".-.."..-.
''l. c; ¡- ()
r. '"
w ,~-~. rn
~3 C":) '-.j
, 0
:::J <
¡n
'., J I i
{~
r.~ 0
E'1
(ñ"
5!l.
0
:;¡
241,637
e
9. Purchased gas
10. Transferred from: CGF
11. Transferred to: CCP
40,171,790
Remarks:
I ~erebY certify th).- th~Oing is true and c~rrect to the best of my knowledge.
SIgnature: % "--"-, - TItle: SUPERVISOR
t"onn 10-422 (Revised 4195)
I Field(s) I Month/Year of Disposition
EASTERN OPERATING AREA-PBU Jun-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
391
Official Use Only--Flaring Authorization> 1 hr.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th oCthe
month following the month of disposition.
Authority 20 AAC 25.235.
DATE
ARCO ALASKA, INC.
CONSERVATION ORDER NO.219
GAS FLARING INCIDENTS
FLOW STATION #1
JUNE 1995
TNE
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
VOLUME MCF
DESCRIPTION OF INCIDENTS & CAUSE
FLARING EVENTS LESS THAN 1 HOUR
06/01/95
06/02/95
e 06/10/95
06/11/95
06/12/95
06/13/95
06/19/95
06/20/95
06/22/95
06/26/95
06/27/95
_TAL UNDER 1 HOUR
1348-1358 3 TIC 1802 shutdown lor lacility maintenance. PLANNED TIC 1801 started.
1655-1705 3 TIC 1801 shutdown lor lacility maintenanc.e. PLANNED TIC 1802 started.
0227 -0303 43 Facility maintenance - "B" HIP separator. UNPLANNED Facility maintenance completed.
0037-0113 48 Replace corrosion injection litting. UNPLANNED Facility maintenance completed.
1700-1705 3 TIC 1802 normal stop. Repair governor oil leak. PLANNED Restarted TIC 1801.
0935-0940 6 Two normal stops on TICL 1802. PLANNED Started TIC 1801.
1700-1705
0220-0330 98 Flared oil 'A' Train HP and IP Separators lor Htr/Cir. UNPLANNED Compressor train depressured.
work.
0500-0535 178 Flared off 'A' Train HP and IP Separators lor Htr/Cir. UNPLANNED Compressor train depressure.
0300-0306 3 Shutdown TIC 1801. UNPLANNED Started 1802 TIC.
1345-1350 3 Shutdown TIC 1802. PLANNED Started 1801 TIC.
0930-0935 3 Shutdown TIC 1801. PLANNED Started 1802 TIC.
391
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
06/09/95 1252-1433 7,804 Shutdown TIC 1804 due 10 instrumentation problems. UNPLANNED Corrected instrumentation problem.
/ð$8 -
06/09/95 1656-2037 4,104 Shutdown TIC 1804 due to instrumentation problems. UNPLANNED Corrected instrumentation problem.
06/22/95 0312-0500 1,042 STV Stagging Valve did not destage UNPLANNED Operator destagged STV stagging valves in 492C
Depressured "A" H/PI Separator Facility maintenance completed.
06123/95 1352-1508 379 Depressured 'A' HP Separator to change oulleaking UNPLANNED Facility maintenance completed.
06/23/95 1540-1641 1,278 1802 TIC backed down 10 idle due to a bad speed card. UNPLANNED Corrected E&I fluctuation/Iailure.
DATE
TOTAL OVER 1 HOUR
Flared
Pllot/Purge
entinuous Assist
TOTAL FLARED
e
~,
i0-
~:.
~
~J4
Ci;
Il>
f,t;!
Q
o
::1
~
l~
h3
3
rr
(II
õ'
::.:I
TNE
14,607
t.'-
c:
r--
^'
rn
n
m
.'.-
-j
-
<
m
o
VOLUME MCF
14,998
26,507
l...I1.Q
43,275
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION #1
JUNE 1995
DESCRIPTION OF INCIDENTS & CAUSE
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
REVISED
Facility
FLOW STATION 1
Disposition
I Operator
ARCO ALASKA, INC.
1. Sold
2. Reinjected
e
3. Flared or vented less than 1 hour
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
Fuel
Assist
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
e
9. Purchased gas
c
p,,, r'"
to. Transferred from: CGF
.~. Co )
" ~-".I
11. Transferred to: CCP
Remarks:
22,201
20,744
32,179
713,416
3.620
792,160
.'A:J
rn
n
m
271,718
I:'~ \,
n~
r-'
·~,,"..,rt
44,986,528
I hereby certify that the foregoing is true and correct to the best of my knowledge.
~~~) ~ - Title: SUPERVISOR
I Field(s) I Month/Year of Disposition
EASTERN OPERATING AREA-PBU May-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
~~!:!:!£iall.lsc Only--I'larin!! "lIlhor!~!.!!i~!'.~~. !.~!:__.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
~
-Þ:
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION #1
MAY 1995
DATE
TIME
VOLUME MCF
DESCRFTION OF INCIDENTS & CAUSE
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
FLARING EVENTS LESS THAN 1 HOUR
05/01/95 1445-1454 41 Dpressured HP separator lor maintenance PLANNED Facility maintenance completed.
05/04/95 1048-1101 217 Testing SESD 01 cooling lans lor STV/IP compressors. PLANNED Loaded compressor.
05/17/95 1545-1548 3 Shutdown TIC 1802 lor lacility maintenance. PLANNED Started TIC 1801.
e 05/22/95 2321-2354 570 1801 shutdown due to an electrical malfunction UNPLANNED Restarted 1801.
05/30/95 1200-1205 3 Normal stop on 1801 TIC. PLANNED Started TIC #1802.
05/30/95 2015-2326 21,367 Flaring lor CGF 1801 shutdown. CGPs 1801 did not PLANNED Reduced inlet gas rates.
restart.
TOTAL UNDER 1 HOUR
22,201
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
05/21/95 1133-1445 16,483 CGF Tandem 1883 shut down. PLANNED Started cutting gas rates.
05/23/95 0001-0120 1,185 1801 shutdown due to an electrical mallunction UNPLANNED Restarted 1801.
05/26/95 1555-1706 1,042 1801 TIC shutdown on high vibration UNPLANNED Restarted 1801.
e 05/29/95 1740-1745 3 1802 Normal stop. UNPLANNED Reloaded 1801.
05/31/95 0300-0615 2,031 Instrumentation problems with P149V. UNPLANNED Corrected instrumentation problem.
TOTAL OVER 1 HOUR
20,744
Flared
Pllot/Purge
Continuous Assist
42,945
32,179
l...§..U
RECEIVED
TOTAL FLARED
78,744
dUN 2 1 1995
i\Jaska ÛJi & Gas Con· 0 '.
t s. ommlsslon
Anchor: ..--
<,.:.i::U ~,' r.li~~íi~.,
, 'i
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
(Facility
FLOW STATION 1
(Operator
ARCO ALASKA INC
Field(S) I
EASTERN OPERATING AREA - PBU
Disposition
Volume MCF*
1. Sold
o
2. Reinjected
_ared or vented less than 1 hour
o
3,345
4. Flared or vented greater than 1 hour
(Supple_ølol repon roquirod--Seo 20 AAC 2S.23~)
o
5. Pilot and Purge
34,261
6. Used for lease operations
738,279
7. Other (Produced gas sent to CCP)
38,664,607
TOTAL
39,440,492
*If production comes from multiple pools,
indicate contribution of each pool to total.
Pool
"~c/.çc
Oftidöll Use Only. Flaring Alllhorizillwn> I h..
1. Safety
2. Lease
3. Conscrv. Purposes
(MonthlYear of Disposition
Apr-95
Percent
/c("\
MCF
MCF
MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
following the month of disposition. Authority 20 AAC 25.253
_arks:
I hereby cenify that the foregoing is true and correct to the best of my knowledge.
S'gna.", cf-~
Title
s~
Form 10-422
Rev. 11194
R£CE\V£O
MA'< 16 1995
1<a on & Gas Cons. Commission
Mas Anchorage
Date:
s/~s-
..
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCÐENTS
FLOW STATION .1
APRIL 1995
DATE
TIlE
VOLUME MCF
DESCRIPTION OF INCIDENTS & CAUSE
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
FLARING EVENTS LESS THAN 1 HOUR
04/01/95 1000-1120 889 Gas Transit system ove¡pressure backing UNPLANNED Reduced inlet gas rates.
flow station out
e 04/01/95 1630-1635 3 SID TIC 1801 from NORMAL SWAP. UNPLANNED 1801 compressor train depressured. Started
TIC 1802.
04/01/95 2230-2235 3 SID TIC 1802 from NORMAL SWAP. UNPLANNED 1802 Compressor train depressured.
04/03/95 1400-1403 21 Excessive inlet gas rates into facility. UNPLANNED Reduced inlet gas rates.
04/07/95 1305-1345 2.344 Electrical maUunction. UNPLANNED Corrected electrical failure.
04/14/95 1030-1048 38 Instrumentation malfunction. UNPLANNED Corrected malfunction.
04/22/95 2208-2225 47 Flared the 'C' HP separator for Energy Isolation UNPLANNED Completed Aaring.
repairs .
TOTAL UNDER 1 HOUR
3,345
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
e
TOTAL OVER 1 HOUR
o
Volume Flared
Measured Safety Pilot
3,345
.3.!...2.§1
TOTAL FLARED
37,606
...
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
FLOW STATION 1
I
operator
ARCO ALASKA INC
Field(S) I
EASTERN OPERATING AREA - PBU
Disposition
Volume MCF'"
1. Sold
o
2. Reinjected
o
.ared or vented less than 1 hour
4. Flared or vented greater than 1 hour
(suppl......... ..pan require4--S.. 20 AAC 25.235)
1,269
154,936
5. Pilot and Purge
33,696
6. Used for lease operations
688,541
7. Other (produced gas sent to CCP)
34,792,631
TOTAL
35,671,073
"'If production comes from multiple pools,
indicate contribution of each pool to total.
Pool
Official 115e Onl y-Flarill!: Allthori7.atioll> 1 hr.
1. Safety
2. Lease
3. Conserv. Purposes
~
IMonthlYear of Disposition
Mar-95 .
Percent
MCF
MCF
MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
following the month of disposition. Authority 20 AAC 25.253
Remarks:
--
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature 1~~(;Y\i(''l. a~JÌ4:~101.- M.>f Title .JJfW.;,l,'\, I'/Dd/..(.k¡,"t f ~~ ~
Form 10-422
Rev. 11/94
R\:.@\'Jf.D
PR '\ ì '995
~ . mission
0\\ &. Gas Cons. com
þ.\as\U\Mcb01a9Ð
,~ ~-;':~:~j~(~r,~-'
Date:
'i /,.1.-/1')'
,.
DATE
DE
VOLUME MCF
AFlCO ALASKA, INC.
CONSERVATION ORDEFI NO. 219
GAS FLAFlING INCIDEN1'S
FLOW STATION ~
MAFlCH 1995
DESCFlPTION OF INCIDENTS" CAUSE
PLANNED
UNPlANNED ACTION TAKEN TO ELIMINATE CAUSE
FLARING EVENTS LESS THAN 1 HOUFI
03/19/95 1557-1601 864 Flare system testing PLANNED Completed flare testing.
03/21/95 0200-0246 36 Flared for commonline 5-D corrosion stud welding. PLANNED Completed 50.
03/22/95 1930-1932 61 Flared due to 1801 shutting down. UNPLANNED Restarted TIC 1801.
e 03/22/95 2030-2035 3 Normal stopped 1802 PLANNED 1801 was at idle. Loaded unit.
03/24/95 0145-0155 60 1803 shut in for planned facility shutdown PLANNED Facility shutdown complete.
03/26/95 0445-0530 40 Flaring for drillsite shutdown PLANNED Completed depressuring 50 Commonline.
03/26/95 2252-2259 15 Relief Valve P102SV leaked by UNPLANNED Blocked valve in until repair.
03/30/95 0825-0830 190 Excessive inlet gas rates into facility. UNPLANNED Reduced inlet gas rates.
TOTAL UNDEFl1 HOUFI 1,269
FLAFlING EVENTS EQUAL TO" GREATER THAN 1 HOUR
03/09/95 0410-0830 36,019
e 03/19/95 0847-1032 26
03/24/95 0500-0630 256
03/24/95 2043-2359 19,650
03/25/95 0001-0445 18,640
03/27/95 0515-0645 37,800
03/27/95 1200-1400 14,730
03/27/95 1800-1920 27,605
2145-2330
~ Annex reboiler SlO due to problem with pilot
burner and air blower. Flared to gas dewpoint
guidelines.
UNPLANNED Corrected instrumentaton and restarted.
Facility maintenance.
UNPLANNED Facility maintenance completed.
Dpressured A-Train HP, IP, Treater. STY Rupture
Disc. failed. (Black Smoke)
PLANNED A Train depressured. Replaced STY Rupture
disc.
Flared for Planned Facility Shutdown.
PLANNED Facility shutdown complete.
Flared for Planned Facility Shutdown. .
PLANNED This depressured the remaining portion
of FS 1 not previously depressured.
Flared off slugcatchers. 1804 would not start.
UNPlANNED Started TIC 1804.
Excessive inlet gas rates into facility.
UNPLANNED Stabilized facility process and operation.
Flaring for drill site shutdown.
UNPlANNED Completed Depressuring Drill Site 1
~-. 11'
DATE
03/28/95
03/31/95
TOTAL OVER 1 HOUR
_Iume Flared
Measured Safety Pilot
TOTAL FLARED
e
1IIE
0001-0200
0145-0500
154,936
VOLUIE MCF
170
40
156,205
1Llli
189,861
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION .1
MARCH 1995
PLANNED
DESCRPTION OF INCIDENTS" CAUSE UNPLANNED ACTION TAKEN TO B.IMINATE CAUSE
Flaring for drill site shutdown. UNPLANNED Completed Depressuring Drill Site 1.
Vented gas from plugged 9"x13" wellhead bleed port. UNPLANNED Closed bleed port after venting gas.
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
fFacility I
FLOW STATION 1
loperator
ARCO ALASKA INC
I Field(s) I
EASTERN OPERATING AREA - PBU
IMonthlYear of Disposition
Feb-95
Disposition
Volume MCF*
*If production comes from multiple pools.
indicate contribution of each pool to total.
Pool
Percent
1. Sold
o
2. Reinjected
o
. Flared or vented ¡,less than 1 hour
16,925
4. Flared or vented greater than 1 hour
(SupplelllODw report requ¡nod--S.. 20 AAC :!S.23S)
7,466
5. Pilot and Purge
33,317
Ol"lidul Use Only-Flaring Authnri"¡lIion> 1 hr.
6. Used for lease operations
699,337
1. Safety
MCF
7. Other (Produced gas sent to CCP)
34,962,294
2. Lease
MCF
TOTAL
35,719,339
3. Conserv. Purposes
MCF
Note: All volumes must be corrected to pressure of 14.65 psi a and to a temperature of 60 degrees F. Report due by the 20th of the month
following the month of disposition. Authority 20 AAC 25.253
_marks:
I hereby certify that the foregoing is true
/7~
S;,."." ¿;/.) Lo.- ~ .
and correct to the best of my knowledge.
Title ~
Date:
3¡;o/~~-
RECEIVED
..~
Form 10-422
Rev. 11194
MAR 1 4 1995
Alaska Oil & Gas Cons. Commission
Mchora
ARCO ALASKA, INC.
CONSERVATION ORDER NO. 219
GAS FLARtIG INCÐENTS
FLOW STATION #1
FEBRUARY 1995
DATE
tilE
VOWME MCF
DESCRIPTION OF ItCIDENTS & CAUSE
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
FLARING EVENTS LESS THAN 1 HOUR
02/01195 0932-0939 49 Excessive inlet gas rates to slugcalchers. UNPLANNED Stabilized facility process and operation.
02/03/95 1545-1616 5,059 Power fluctuation/failure during startup of UNPLANNED Corrected power fluctuation/failure.
Module 4942 (Annex) after power failure.
e 02/06/95 1900-1907 3 TIC 1801 shutdown due to NORMAL STOP PLANNED Loaded 1802
02/08/95 0201-0222 292 Flared 011 "B" gas train. Pressure safety UNPLANNED Blocked in safety valve until repaired.
Valve lifted.
02/09/95 1717-1750 450 TIC 1802 speed control. Insl. malfunction. UNPLANNED Loaded 1801.
02/09/95 1750-1755 3 Normal stop on TIC 1802. PLANNED Loaded 1801.
02/10/95 1200-1210 3 Normal stop on TIC 1801. PLANNED Loaded 1802.
02/11/95 1600-1620 11 Flared off 'C' train HP scrubber. CHD system PLANNED Completed depressuring vessels.
blind inst.
02/18/95 1826-1919 10,894 CGF lost 1883 compressor. Flare valves opened to UNPLANNED Stabilized facility process & operation.
relieve system overpressure.
02/21/95 0700-0746 153 Flaring for 2E shutdown for maintenance. PLANNED 2E CIL maintenance completed.
02/25/95 1300-1308 8 CCP emmissions test on TIC 1804. Reduced inlet gas rates to slugcalchers.
e Flare valves opened to relieve system overpressure.
TOTAL UNDER 1 HOUR 16,925
FLARING EVENTS EQUAL TO & GREATER THAN 1 HOUR
02/02/95
t113-1125
1315-1446
1520-1805
7,438
Electrical disruption due to power fluctuation
UNPLANNED Corrected power fluctuation/failure.
02/20/95
1700-1800
28
Depressured C lIP separator for nipple changes
due to corrosion repair.
PLANNED Facility maintenance completed.
TOTAL OVER 1 HOUR
7,466
Volume Flared
Measured Safety Pilot
24,391
n.uz
RECEIVED
TOTAL FLARED
57,708
MAR 1 4 1995
~¡?ska Oil & Gas Cons. Commission
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
FLOW STATION 1
loperator
ARCO ALASKA INC
Field(S) I
EASTERN OPERATING AREA - PBU
Disposition
Volume MCF*
*If production comes from multiple pools,
. indicate i~on ...Of each pool to total.
Pool I ~
1. Sold
o
2. Reinjected
o
_lared or vented less than 1 hour
\
l,575
~
4. Flared or vented greater than 1 hour
(SupplemeDw report required--See 20 AAC 25.235)
1,095
5. Pilot and Purge
35,716
Official Use Only.Flaring Authorization> 1 hr.
6. Used for lease operations
~
1. Safety
705,103
7. Ot~~(Pro~~+~ent to <:<:.~~__ ____-'~,203~5_~
~n-::~ 7lfO¡ '-I~'J-:;¡---=--~~,*7,064 7L-(~GOu
2. Lease
3. Conserv. Purposes
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
following the month of disposition. Authority 20 AAC 25.253
.marks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
S;,""",, µ- I·
Title
s~
Form 10-422
Rev. 11/94
. f:;£C£IV£D
.<j¡q,)'Æ;. e,2 2
iì Ùl¡ & G. 1995
<'lsc.
A/Jc/¡. Oils. C.
'O/'é/ 0/J}/h'
.. R "//SS/Ot¡
IMonth/Year of Disposition
Jan-95
Date:
Percent
0ftJ~
'" .
MCF
MCF
MCF
1,095
4>~
"i/ . it:' C¿:-/ 2,670
«.5;& _ ('6> /þ L'~
Q' 0) ? <../\
fiQ '2 A ~.386
~ Q>.so C ~.9J'0
t'qo~~ Q,,~
ç 'b~
~¿,,£ .
~I)
DATE
l1ME
PLARING EVENTS LESS THAN 1 HOUR
01/03/95 0830-0900
e 01/10/95 0115-0120
01/12/95 1235-1240
01/15/95 1719-1738
01/19/95 1 230-1 237
01/20/95 0930-1020
01/28/95
1715-1720
TOTAL UNDER 1 HOUR
1,575
_ARING EVENTS GREATER THAN 1 HOUR
01/19/95
0152-0341
TOTAL OVER 1 HOUR
Volume Flared
Measured Safety Pilot
TOTAL FLARED
"
ARCO ALASKA, INC.
CONSERVA110N ORDER NO. 219
GAS FLARING INCIDENTS
FLOW STATION .1
JANUARY 1995
VOLUME MCF
PLANNED
UNPLANNED
ACTION TAKEN TO ELIMINATE CAUSE
DESCRlP110N OF INClDENlS & CAUSE
150 Replaced suspected corroded piping on "B" Train PLANNED Repaired and replaced piping on bridle.
HP Sap.
80 TIC 1803 shutdown for repairs and ESD/OSD PlANNED Reduced inlet gas rates to slugcatchers.
testing.
60 TIC 1804 shutdown for repairs and ESD/OSD PLANNED Loaded TIC 1803.
testing.
859 TIC 1804 recycle valve malfunction. UNPlANNED Corrected problem.
80 TIC 1803 seal oil high temp switch problems. UNPlANNED TIC 1804 on line.
343 Depressured "A" Train HP separator, scrubber, PLANNED Maintenance completed.
and 5D commonline. Replaced damaged thermoweld.
3 NORMAL STOP 1801due to TIC 1801 Shutdown. PLANNED Loaded TIC 1802
1,095
TIC 1802 shutdown due to suction scrubber
high level.
TIC 1802 would not start, loaded TIC 1801.
UNPLANNED
0\
1
(6r~L (
~-
~RJ>..µ5~ (
---
^
e
L--
~-
~
(
L---
~6~1--- ?e D
¡4~OO)
Sív~ ú~ó)
'-:.---
~
~
- ......~
e
7
-,---
l ¡, 0
.