Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
HOME
EVENTS
DATA
Data List
Drilling
Production
Orders
Data Miner
Document Search
REPORTS
Reports and Charts
Pool Statistics
FORMS
LINKS
Links
Test Notification
Data Requests
Regulations
Industry Guidance Bulletins
How to Apply
ABOUT US
History
Staff
HELP
Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PHILLIPS - ALPINE
GAS DISPOSITION FILES Field ;i~~PS 2000 ~- ALASKA OIL AND GAS CONSERVATION COMMISSI FACILITY REPORT OF PRODUCED GAS DISPOSITI Facility ALPINE PROCESSING FACILITY Operator PHILLIPS ALASKA, INC. Field(s) ALPINE Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 219 4. Flared or vented greater than 1 hour Su lemental re ort re uired--See 20 AAC 25.235) 1,841 5. Pilot and Purge 0 6. Used for lease operations Fuel Assist 0 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 2,060 8. NGL gas equivalent produced 0 9. Purchased gas 36,871 10. Transferred from: 0 11. Transferred to: 0 Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: ~ v-'- ~ ~~ Title: SV~°~'~y f S $ ~' Date: l~ «~~ Form 10-422 (Revised 4/95) ON ON Month/Year of Disposition 9/00 "Indicate contribution of each pool to total. Pooi Name Code Percent ALPINE 100.00% ........................ fOffcial use:Onl ==Flanii ............................. : AutMesrizatian > : hr: 1. 'Safety MCF 2. Lease Use ~'Gd ~ MCF 3. Conserv. Purposes MCF a ~ / i Commission 'r ~lOy a Y Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. v~-- ~ ~/.~ l~yz~~ Gas Disposition Summary Colville River Field Gas Disposition Form 10-422 Incident Summary Page 2 September Overview Construction continues to progress towards startup. Temporary fuel gas from the KRU field began shipment to the Colville River Field on September 3, 2000. Shortly thereafter the power turbine began test runs on fuel gas, and was placed in service for the first time on September 11. The power turbine went into full time service the first week of October. The new Corona Flare was first tested on September 23. The first of several well flowbacks was performed September 15. The flowbacks are designed to unload kill weight fluids and drilled solids remaining in the wellbore following the drilling program. Each well flowback unload approximately 1000 bbl of fluid, and take from 6-12 hours to complete. In accordance with 20 AAC 25.235(b), the following releases are included in Form 10- 422. Supplemental information explaining each event is provided below. The following events did not exceed the 1 hour limit. Date & Time Event Summary Gas Volume 9/03 - 9/07 Prior to starting the power turbine, fuel gas was briefly 204 MSCF vented at the fuel inlet to the turbine. The purpose was to warm the fuel lines sufficiently to remove any condensed hydrocarbon liquids. 9/06/00 A card failure in the Moore control system led to an 15 MSCF unplanned release in the J1 power generator building. 18:30 -18:31 The card failure triggered the control valves to depressure the fuel lines, which was the designated response to such a signal. Total Volume Reported on 10-422 Line 3 219 MSCF Gas Disposition Summary Colville River Field The following events exceeded the 1 hour limit. Page 3 Date & Time Event Summary Gas Volume 9/15/00 21:38 Flowback and unload well CD1-41. All fluids are 391 MSCF to contained in tanks set next to well CD1-45 on the south 9/16/00 05:36 end of the drilling pad. Gases are vented directly from the tanks during the operation. 9/28/00 Flowback and unload well CD1-O5. All fluids are 475 MSCF 15:05 to 20:15 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 9/29/00 Flowback and unload well CD1-06. All fluids are 595 MSCF 09:05 to 15:15 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 9/30/00 Flowback and unload well CD1-09. All fluids are 380 MSCF 09:20 to 16:35 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. Total Volume Reported on 10-422 Line 4 1841 MSCF Weekly Flare Update Subject: Weekly Flare Update Date: Tue, 12 Sep 2000 17:44:38 -0900 From: "Michael D Erwin" <MERWIN@ppco.com> To: Wendy_Mahan@admin.state.ak.us, blair_wondzell@admin.state.ak.us CC: aogcc~rudhoebay@admin.state.ak.us, "Donnelly&Manson" <N1508@ppco.com>, "Brian D Richards" <BRICHAR4@ppco.com>, "Mark M Ireland" <MIRELAND@ppco.com>, "Barry J Sossamon" <SOSSAMON@ppco.com>, "Arnoldi&Kay" <AKAY@ppco.com> Wendy and Blair, Just a note to let you know of the progress since my last note on startup progress. At the time of my previous note fuel gas from KR.U was present at Alpine in the seawater pipeline, but not in service. We started taking fuel gas on Sept. 3 by pressuring the line from CPF-2 to Alpine. We vented gas for several hours to pressure and commission the fuel gas piping. The turbine driving the primary generator has been run uncoupled several times now and testing of that phase is complete. Next the turbine will be coupled to begin testing of the complete turbine/generator skid for several days (up and down using fuel gas). At the completion of that testing, we plan several days of testing the turbine on arctic heating fuel (AHF). At the completion of the AHF testing, the turbine/generator will be lined up with the plant electrical grid and begin normal operation. At the completion of the liquid fuel test, the entire train will be operating full-time into the grid. Work continues on numerous fronts as progress continues towards startup. Fuel gas consumption will increase as we accept additional heating equipment and fired vessels for run-in. We reported an unplanned minor gas release (15 MSCF) on September 6th associated with ongoing construction operations. In response to Dan Seamount, Jr.'s recent letter requesting additional information regarding facility design and it's impact on flared gas at Alpine, a draft has been prepared and is currently under review. Please call if you have any questions. mike 9/13/00 8:25 AM lofl 10-17-DO D6:28 From-ALPINE NSNR + T-565 P.12/12 F-917 _ FLARR GAS VPNTiNG REPORT `„1 PHILLIPS ALASKA, ING. • PRUDH01= BAY/GPMAJKUPARUK FacluiY: A I pir^ice:>C1F~~'s~EaQ~i~i`~~'Pro~lrr wo. - ) GAS DISPOSITION Date of Ooourrrsnce: ~ ! (.~ ~ O U ^ Rare ~Vdtt (mm/ddlyy) (Check SeleWon) From Total volume Flared: ~MSCF BBLS From: From: Mated~lcR~ ~•~•~•::•:•:::~:~•~•- ~ ~ arii ^rwr~ec ~unplfbins0 From: (t~tedc Seleotiarr) From: From: i Time of Oteurrence• ~,Qg 29:QQ Minutes To: o ...._._._ Yo. To: I Total Minutes Flarmd: I = ~ j~, [tasburrre OrNy - [3as tlarea ryas irrxn CI cl ^ doMm:auem iCxaek one) (rrreiuotss volume tlarrxf whixdt ggng>dted brao!c smoke. of rLeG wrpecrormeterai LPC) 11 ~1 A_ Description of Incident arttl Correa: (Check as marry as rreodcd m fully describe tl~a ireidonq SID TICt for TIC SD due m high exhaust temperature Seat oil system giffirarlties EMEJtGF_P1CY SFIITI'DbVVrd Elearica{ I Intrtrumeruatien maltutCfiort ElerAfiCai l Instnvmerttation mttlhxw•tion at Outer faality (T8D) G1aaS tratteft 9Yetem Overpressure ~~ ! CPFIFlOw station out ~„~ Excessive I insufficient cruet gas rates into fadiity B. Action Taken m t:.Grrtirrale Cauee and Areverrt RacumDneo: (C1teeK and describe ss appfieable) Started /restarted T/C # Compressor /train deptessured y~__ Reduced / incressetl inlet gas rates Completed flare leafing ~_ Cprrected E&t fluctuation / faNure Corrected E8I flucbration / faNure at other facility (7&D) Process trpeat in 1 section of tadligr I F7srirrg far dnllsite shtddown r startup Flare system testkt9 Fauky srxrtdorrrt on s=adlity mairllenerx:e ~ High amtuertt lemperaMes. I SID on high vibration Other: r~• ,~ C.~i i deQr~nt.,r i'~-ln~f-ct~i It-Fy . Stalalized faeitity process and operation Repaired equipment difticutties ,NiUt reu. ~ f7~ ~rlse /r~.desl'gr•-, of Facility maintenance oorrtpletetl •5~f S•~.r'rl . Other: ~ Black make ; i Did inrtident cause blst~c Smoke? Yes: ~ No: ~ (lf Yes, cominue with this section) Did inadeM present a poterriial threat to human health or safety? Yas: ~ No: (N Yes, report to FEC as soon as possible. If No, report to ADEC w8h 24 hours.} Brack smoke ~~ front ~~; (enter tag number and description) Notified AI~EC by Faxon: pate: Tlme: Repoli the fdkawing lydor{twtion to ADEC within 2b hoursf3Y FAX (9W-289~75aHk , Hate and time of bladt smoke event: From: To: Volume flared which pen rated blade smoke ('rf different from above): MSCF _ BBL.$ Description of stops to rr>lnimize emissions: See Sectkxt 8, above. Type of materials burned: Caas: NGLs: Other I General Weather. Air Temperature: Wind SpeedllDirectlon: I Name and phone nttmpe(of person making the report Name Phone No. Based on infttntlation and belief firmed after reasonable Inquiry, I certify that the statements and iMormation in and attached to this document are true, accurate d complete. i ~~ I Faollfty supervisor cote oL". EOC Supervisor. PRB 6 (flare gas and black Snake tnddertts) Fi91d Emnronmental Comptlartce toordirtatora, PRB 7 (6laalc Smoke inciderres ony) PBU/GPMA Field Managers, (Blade smoke inoitleMs only) GiPMA Operations Engineering Technical Aide, (GPMA reports only - ATQ 477) Kuparuk: Feld Bnvironmentat Compltanoe Coordlnatore, NSK Bt (flare gas and black emoke incidence) upe~e~ FEC 6+00 P:~Groups\N~i1~r«mer>Ta- t+eiP~Fom~s~Rareracs Vnntlnd Farm 898 10-17-00 06:22 From-ALPINE NS~dI' + T-562 P.08/12 F-917 ~~ FLARE GAS VEN77NG REPORT ~• 4`~'~~-~M''"'~ PHILWPS ALASKA, INC. • PRUpDHOE SAY/GPMA/KUPARUK FACltmf: ~ ~il'a1C ~ ~VV.Ex:r+T-1-Re dC~~ PERMR NO. t'9~' ? ~'~'• ~ A '~"• Date of Occurrence: Cs`1~3o rf d U ^ Fwre ~'vem (mm/dd/yy) (Check Selecdon) Total volurrle Flared: ~~ ~ AeSCF BBLS Mstklr Nt-M ' • B p~ Planned ^ lRtMmried {Check Selection) (Lisburne [M!j' -Gas Raratll~ hbRt ^+N~®m ^ aown~n'a~m {crreae one) of 7~G carn~xarmererat LF4CJ To: - To: To: _ To: Time of pr~cunence• ~~ O To: 2b~' . = 13 To: ~ - From: From: From: From: From: From: Total Minutes Flared: I a {!nc>t,des volume flared wfudr yenentted;bladr smoke. ifapplicable) A. Ipttart of ktekfert and Cause: (Check as many as needed to fully describe ifte ittddatt) SID T/Clr for T/G $D dub to Ir'gn extiausr temperature Seal ail system diffiGUltiss _ reMERQENCY SIit1TDpWiv ~~ EI!lGtefCal / Insirumantatian mBNunation ~"'-~' FIor,Frira! / Irts4umantgtion fr{alfGtIC11011 at other taaligr {T&D) ,,,,^,,,_ Cat transit system oveipressu~ backing CPF/Fbw Station out Exceeahre I Insutlident inlet gas cafes into reality B. Action Taiwan to Elimiratta Cause and Prevent Rectgrettee- (Chtrdt and dtuxrlba as applkabla) Stnrtad /restarted T/C # __ _ _ Compressor /train depnassured ~,__ Reduced /Increased imef gas rates Completed flare tasting Gom9ct6d F~1 fluctuation /failure Corrected E&I fluctuation /failure at other fadlity (T&D) Black Smoke Process upset in section of tadlity Flafin+j faf tlfillSite shutdown /~atartup Flare system testing Faulty shutdown an Fatuity m3inienance ~ High ambient tempsr#tunes. ~ __ StD on high vibraflo Other: ~ ~LLk14M.1~,~ w : c tw tu-- ~~ b ~e'izrea o aF ~Ac.~~ 1T~ Stabilized facility prot~ss site aperatiorr flepaired equipment dit{ictiriies wills _ Faoil'ny maintenance oompletetl other. .~ I~ ECM/ ~,~,af,.. SNdW ~ "' ~~ trrf-.~ U ~ IMC~ !O ~~} Dfd Incident cause bladt Smoke? Yes: ^ No: ` (if Yes, continue with this section) Pid incident pretaent a potential thrar3tt to humetrt health or safety? Yes: ^ Nn: ^ {If Yea, report to FEC ~ soon t~ possible. ff No, report to AQEC with ?A hours.) 9latflt smoke emitted from source: {enter tag number and dttscxxipdan) Notified ADEC by Fax on: Dam: Time: I~aport the followhrp intarmation Eo ADEC whlain 24 hours 8Y FA]C (847 269-75DBk Date and time of blaok arnoke evert: From: To: Volume flared whkdt generated tdack smoke (-f different from above): ~_ MSCF ~ BBLS Description of steps to minimize emiseicns: See Section 8, above. • Type of materials burned: Cias: NGLs: Other. -- _ General Wet3tfllef: Air Temp9rdture; wnd Sptrt:dtDirection: Name and phone number of person making the report: Name Based on iMvrmafion aaQ'delief fonnad d(ter reasonable inquiry, I certify that the statements and infamtatlon in and document are true, saxtrate and complete. Facfltty Supen-laor ~ bate ~~3o~aO -_ - . Fhone No_ l 0-17-0o as :22 From-ALPINE NSlAT .~ ~1_AR~ GAS VENTING REPORT .~ -SKl1, INC. * PRUDHOE BAY/GPMA/l[UP T-562 P.09/12 F-917 .;-, - - i ~acunY: f~i tPrty~ ~~ ia~i~r-a°' ~R o dt~'~~tR No. :? ~_" ~..~+,i~a'~ 1 pate of Oeerrrrerlce: a3 q .Z R d~ ^~ I~~ (mmlddyy) (check SaleCtton) Total VOlums Flares: +~ 1 ~MSCF sBLS .. {$~,nea CIS • (Check Selection) lLisbume Ony- Qas flared w~ fmrn ^ u~rom ^ dotirn~arn (C-recx One) at TEG pontaclormeterat bPC} Tlnte of Occurronce- . ~ 24_m NJi From: ' 0' ~-' To: 1~l'/ ~ _ '~57 !'! From: To: _ „_~„ From: ~ 70: ~ From: To: _ _,_,^ Prom: To: ~ _ From: To: _ TaRril Minutes Flared: ~ ~ ~ (Includes volume flared which gelrelatarl black smoke, if applicable) A- pescriptiori ollntrfrlarrt and Cautla: (CfteCK as many as rtseded 14 tatty describe the irttltlsnt) SID T/Gtl for _,,,~-~ T/C SD due to high exhaust temperature SCI oil system dlfticutties EMERGENCY SHUTDOWN ~^ Erer.Hrical l Insvumentation maliun~tion EleCll'ICaI f Insnumeritation rtlalfunctlon at Dater tacYKY R&~ ~~ ~~ f3as transit system ~ baddnp GPFiFlow Station out ~_ ~xcds8ive f insurfxaertt inlet pas • rates irUC taciGty B. Action Taken W Eliminata Cause arrtl Prevarrt Racraa~raarrCa: (ChsOk and descrltle as appllca6le) Started / restarted T/C # Ccmpresaor /train ttepresSUred Reduced /increased inlet gas rates completed flare issting Gorreated E&I f~x~ration ! faiure _ Cornt~d EEd flucwation /failure a! other faetiiry (T&D) Black Smoke Process upset in SeCnon of fadY'ty Fieuing for driNsita Shutdown / 8rarruP Flare system testing , Fauhy stvrkwwn on Facility maintansnoe High amt:lent temperakues. i S!D n high vibrdtitln Other. U ~- t.47 4,D 4' G~`I if/~, Lew ICs nF C ~.1+ ~4 . i!uu' Q ,~. 1 0 L iAf ~'"' I4C.f L •7'Y Stabilized fad8ty process and operation Repaired equipment difficukies with Facility meimenance compl®ted Other: ~'~vPP~~ ~ H- =~J Lrl~Z.l.. ~~+e w~= f~i ~ni d~ 2'c.~~ff~.lc~.~f1' ~I~G~IO~~~ Did indderit cause black smoke? Yes: ^ No: {~ (If Yes, continue with tiffs section) Did incident presets a potenflel threat to twman health nr safety? Yes: ^ No: ^ (tf Yes,. report to FEC as soon sis posslble_ K Na, repr-rt to ACIEC with 24 hours.) Bleat smoke emitted from souroe: (enter tag number and description) Notified ADEG bi+ Fax on: CAte: Tt~: iTspvrt the tottorWrrg irrform~ to Al,7EC wmrn 24 hours BY FAIL (807~69.7'S08k Date and trrrte of b~Clt smoke event From: To: Votttme flared which genFrated bladt smoke (rf different from above): MSGF BBL.3 Description of steps ~ rrtinintizs emissions: See Sectlort B. above. ' Type of materials burned: Gas: NGI,s: Other. _ Generdl wbather. Air Temperature: - - Wind SpaedlGtirec4on: ~ Name and phone number of person making the report: - Narrre Phone No. Based on irtfottriation and belief fomred after reasonable inquiry, I certifyr that the statemems and irtfarrrratiort in and attached to this documentare true, accurate and complete altos Pacglhf srlllerviso- t ~ ~ ~~ ~d0 cxx EOC SupaMsor, PFtl3 t3 (flare gas and tlladt smoke irxddS~nts) Field Ernrirarinrenfal Gompllance cpordinators, PRB 7 {Blactt Srrtolte incidents onlyr) ; PBUlGPMA Feld Managers, (Black smoke Nddents Drily) GPMA Operations F~rgineerirtg Tedtnk~l AWe. (GPMA reports only - ATO 477) ' Kt~n/k: FSekf Environmental Gompliartce cocrdinatpra, NSK 61 (flare gas and 6laclt smoke incidents) 10-17-00 06:27 From-ALPINE NSfutT + T-565 P.10/12 F-917 '-~'' FLARE GAS VENTING REPOF~T ~.•' ~~' + PIiILII"IPS ALASKA, tNC. • PRUdIiQf BAY/GPMiAfKUPARUK FACIUrY: Art~f~1~1.~~- ~Ra.><~f~f~uurNra, :t9Q"~''~-~~'C GAB DISPOS171aN pace of Oecurrenoa: _ +~ /~ $~Cfl~ ^ Flea ~(Yent Tlme of oocu - (mmlddMd {Check $e1e4Micn) ~'QQ 24:00 in From: ).CD S To: 2d 1 = ~..~ (a Total Yolurrre Flar+sd: MSCF BBLS From: To: From: Tv: _ __ - ~;: " `. ~ ^ UnA~+ro From: ~ To: - (Ch~ck Selection) From: ~- To: -- _ _ _ _,,,,, From: To: Total Minutes Flared: I ~ ~ f ~ (LisburflB Orln' -Gas stared e+as horn ^ ^ dowrsheam fe++ock C>r+0) (lrtdudes IAD/lR/le flareKf WrllLY1 gBli9rat8d bYdr~[ smoke, '~ of TEG cwNactor r»eterat LPIC) ~~) q, perrxtpdon of Mtciuern and Carne: (Check as many ~ rteedc+d to tally deacriba the ineltlent) SIP TICK for YIC SQ due m high exhaust temperahere Sail Ol SySEem ddllGUldes EMBRGl=tVCY SHl1TOONVN „-r_ EIeCklt~I / Irlstrtenarrta6cn rrralturwtion SlerAriCiF / lnStrUelent8ti0n melhrrlCti0r1 T~_ eu otirer iaal~tr (T&D) Gee transit eystern ovalpraseura tx~cldttp CPF/Flaw 5'tation oUt ~~ wive / itsutfiC-iMlt inlet 'rates -urto faallry 8. Actlon 1'alterr w Epmktste Cause and Prevent Recearerrc.: (cttaclt and aeaGdt+e as appliealrla) started / restaned 7/C e Compressor /train dep:easured Reduced / Irta~eased Inlet gas reuse ~- Completed flare testing Corrected Fall fluchtatiott / faih,re ~^ Corrected B&I fluctuation /failure art other facllley (T&D) Black -Sliioke Proaesa upsetin sectlart of tetdllty Flaring for dress-xe ahutdortm'/ stArtup Flan: system testing ~ Fiully ehutdOWrf on Facility mairuerrirrce hllgh eunbient Osntpera tures. S on high vlbra " n ru MsU~ /CL' - lI G ~ y OS' FO S''1^fl t-tl mil` /Nl~ ~AGu_.fr yj_ stabnized tacitityr process and operation Repaired equlpmertt dlffiailties vrith Facility mairuenanoe oompleted Other. = ~ • '61NE~ 1. tl-^LL `° -~oW ~' ~ s K' Ct r tti1 ti P W b/o~ Did inCidartt cause black ernoke7 Yes: ^ No: ~ {If Yes. continua with this secaiCtt} did irtciderrt present a pgtential threat t4 hurrlan healfll or safety? Yes: © No: 1. (lf Yes, ntporl to F'BC as soon as poserlble.l! No, rep~art to ADEC with 24 hams,) Black eurtoks emitted irant ewune: (enter tag number and derecriptlort) . Nctitled ADEG by Fax orl: Date: Time: tiepat the tdewlttg hrlbrlrrtlUoa to AD6o wlth6l T4 Hours @Y,~ (eo7-2~75aek Date and time of black s~rtoke event: From: to: ~ Volume flared tertticxt generated bledc smoke (tf different from above): MSCF BSL.4 Description of steps to mininrize errtiseiCrtB: See Sectktn B, above. ~ Type of materials bumer~: r3as: NGIs: ~~ Qgter: ®eneral Weather: Air Temperature: Wind SpeedlDirecuan: Name and phone nulrtber of person making the report; Name Phone No. Based on information artii belief formed after reasonable inquiry, I certify that the statements dnd information in and attached. to this document are true, aocu{a~ and Coat e . FacAfLy Stgaelvlsa ~ ~~~~ F~ , 10-17-00 06:27 From-ALPINE NSf~IT + T-585 P.11/12 F-917 `~ Fi.ARE CyAS VENTING REPORT ~~ ~~ ~ ~ ~! - PHILI..IPS AL.A&KA, INC. - PRUDHOE BAY/GPMAIFCUPARI.IiC Fncli:flY: ~LI°IN~'~~tPiE1~".IMa'i', fRaJtc"~'PEaIwIiNO. ad7.3~ A~c~a±~-. Date of QCCUr'r+enese: b9/L~;,/an -- o~i~ ca ORS ®~ (mmlddlyy) (Check Selection) Total Volume Flared: ~_MSCF BBLS ~ ~Rfannad ^ urwlwtn~d - (Check Selection) (Lis4uma OrdY- rsi~ fl8rad was from ^ ^ !~~* ~J Of 'l'):Li Pf mensr Af tFG) Time of Go ourrenoa• 11Q.:1]Q 29:QQ ~IIQSd47e From: ~~jrr a I : 3 8 To: 2~ ; i?C- L '~~ From:4~j~ ~i d Ta: OS:3ra = 33 (o From: Tp: - From: To: ~ From: ~ 70: i = ~,~ From: To: Total Mirtatdtt Flaretl: ~ _ (lrrdua-es voltrma Adrl9d wlrlch ga<-erdterf black smoke, 1LaPP~b) i A. description ~ IrraMeht end Causer (Cterdr es merry es rleerlOe Eo fully rbSCttbo the trrefdarn) SJD T/Crs for _ T1C SO due m hig-r exhaust temperawre $eal od system O'iifCultieS EMi'sRtiF~iCY SHUTOC~NN -..~- Electrical / InsWmentation rrlalfurrra6on ~__ Electdral 1lnstrurnenffitlon rr-aUwx~fon at other facditY (T8~p) ~- Gas trer-Sit system overpressure darddng CPF1Fbw Station out Excaeaive / insuifimam irder gas "~ rags keo tawny ~- Aglow Taken to 0lminate raid Pl~vetlt Recurrence: (CttecK and eeeeribe sea applicable) Started !restarted T/C ~ __ Compressor /train dapressured -- _ - - - - Reckaced / inoreas+ed inlet gas rates Camptated flare testing _ Cornestad E&I flueluatlon / failure ~,~C~_ Corrected F..SI fluogratron ! feiilura at other facr~ity (T&D) Black Smoke Pr4Ce55 upset in section of tacilky Flaring for tln'IISiER Shuttlown t sffirtup Flare system tea4ng Fauliy shutrsowrr on Facility inaiMenanae -- rlign ambient terrlperauues. i SID on high vib lion Other. tA1.}~ae.~~GtL~a±An.+ul>~~.ou+~gC~ a r`- ~~ ~ I I lu plt~r~l~le fir.+_ n - _ -~ _ ~n i~ ~774rP'rV 14 o as ~ (o/ry~' ~IaC1~/~. Stabilizetl fadlity process~and operattan Repaired equipment 4if~laes with I Fadiky maintenance completed Dtittec S" l't~PPI~ W t•1~fi ~r..t_ S r3\ it 5 l6 N ~. o , i..~At4ft1JC5 lt.P' ,WG~.LQ° Did inadern cause blscit smoKe? Yes: ^ No: ~ (If Yes, oarrtinuA wsl't Otis sectbn) . (7itl lnddent present a potemial threat tp humarti health or safety? Yes: ^ No: ^ {If YaB, report to FEC as goon as paestble. K No, report to At7EC vlltft 24 hours Blast smoke emitted frorrt apurCB: (enter tag number and easooription) ~ NotiRae AGEaC by Faxon: fasts: Tirrt®: ' Report ttte following irrforirration 11D ADEC wiprM tut bow's By FAX (907.75f>9~ ~ Date and time of black smoke event: From: To: ! Volume fiauad which ganerabd black smoke (rf different from shave): MBCF BBLS Description of steps to minimize ®rrtisslarts: See Sectlort B, above. Type oft materials burned: Gas: _ _ _-- -NGt.,S: Other: Genera! Weather: Air Temperature: Wtnd Speed/Direction: Name antl phone number of person making the reporC _ _ Name Pho~e No. -- - -f3esed on infomtalion snf! belief burled sitar reasanaele inquiry, l certify that the statemerns and irrforrrratiorr in and attached jo this documern are true. accu~ and comp) .tt:. ; Faeflfty Supervisor Date _1 ~ ~, cc: E pervisor. PRB 6 (flare pas and black smoke incidems) i Feld Emrinxrmentel Compliance c`.aoreinetors. PHB 7 (Black Smoke inddants only) i PBIJ/GPMA Field Managers, (9laclt smoke incidents only) GPMA Operations Engineering Technical Aide, (GPMA reports only - ATt7 R7~ Kupareik: Feld FsrvironmenffiI Compliance Coordinators, N5K 81 (flare gas one Wadr smoke incidents) upeate~ FCC BlryO R~6roups1rr5f:TGnviraimerdol I~lelp\F4rms\AM.xls ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator ALPINE PROCESSING FACILITY PHILLIPS ALASKA, INC. Field(s) ALPINE Disposition Volume MCF' ,.Sold RECEI Q 0 2. Reinjected N O U 2 1 2 00 0 A{aska Oil & as ons. 3. Flared or vented less than 1 hour ~`~~~ 0 4. Flared or vented greater than 1 hour Su lemental re ort re uired--See 20 AAC 25.235 3,769 5. Pilot and Purge 0 6. Used for lease operations Fuel Assist 0 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 3,769 8. NGL gas equivalent produced 0 9. Purchased gas 1,336 10. Transferred from: 0 11. Transferred to: 0 Remarks: I hereby certify that the foregoinglis true .a~n~d? correct to the best of my knowledge. Signature: L~~i'f~l~/ ~L'Z' ~'"~ Title: ~L'~~~' Date: `r~~~ Uzi Month/Year of Disposition *Indicate contribution of each pool to total. Pool Name Code Percent ALPINE 100.00% «ffcial lJse:On( =>Ktar$t : A,uthc~rization ~ l: lir:::::: >: 1. Safety MCF 2. Lease Use ~ ? ~,~ MCF 3. Conserv. Purposes MCF f r Commission ~So~- Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ~i~ .~~ ~~~~~~ Form 10-422 evised 4/95) Gas Disposition Summary Colville River Field Gas Disposition Form 10-422 Incident Summary October Overview Page 2 Construction is wrapping up as modules and systems are turned over to Operations in preparation for startup. October was a busy month for well flowbacks, with 12 wells completed. There are no other flare or vent incidents to report for the month. In accordance with 20 AAC 25.235(b), the following releases are included in Form 10- 422. Supplemental information explaining each event is provided below. The following events exceeded the 1 hour limit. Date & Time Event Summary Gas Volume 10/02/00 Flowback and unload well CD1-38. The well died 285 MSCF 13:00 to 17:30 prematurely prior to completing the flowback. All fluids are contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/04/00 Flowback and unload well CD1-38. The well was 356 MSCF 08:30 to 11:45 kicked off again, this time with nitrogen, and continued flowing on it's own until cleaned up. All fluids are contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/06/00 Flowback and unload well CD1-22. All fluids are 393 MSCF 08:00 to 17:00 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/08/00 Flowback and unload well CD1-44. All fluids are 474 MSCF 08:15 to 15:30 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/11/00 Flowback and unload well CD1-35. All fluids are 355 MSCF 14:00 to 20:00 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. aECEl~IE~- NUV 2 1 20G~? Alaska OH & Gas Cons. Commission Gas Disposition Summary Colville River Field Events exceeding 1 hour limit (continued); Page 3 10/14/00 Flowback and unload well CD1-34. All fluids are 192 MSCF 14:00 to 17:45 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/18/00 Flowback and unload well CD1-32. All fluids are 446 MSCF 11:30 to 18:45 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/20/00 Flowback and unload well CD1-27. All fluids are 300 MSCF 10:00 to 18:45 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/22/00 Flowback and unload well CD1-40. All fluids are 253 MSCF 08:45 to 21:30 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/25/00 Flowback and unload well CD1-30. All fluids are 171 MSCF 12:00 to 15 :00 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/26/00 Flowback and unload well CD1-43. All fluids are 124 MSCF 11:00 to 15:30 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/27/00 Flowback and unload well CD1-24. All fluids are 209 MSCF 12:00 to 17:00 contained in tanks set next to well CD 1-45 on the south end of the drilling pad. Gases are vented directly from the tanks during the operation. 10/30/00 Flowback and unload well CD1-17. All fluids are 211 MSCF 11:00 to 15:15 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented .directly from the tanks during the operation. Total Volume Reported on 10-422 Line 4 3,769 MSCF RECEIVED NC'J 2 i ~~~R /~{8S~i8 Qli 8t i2S COI15. tiOtTlR11SSfOt1 J111Ct10fagC 10-17-00 06:22 Date of taccurrence: Total Yolume Flared: From-ALPINE NSfw>T iPHILLiPS FAGIUtIr: /'t Iptvt + T-562 P.07/12 F-91T !-LAKIC IaA~ V t1Y 1 IIYta nCrvR r ' ~SKA. INC. • PF~UDHOE BAY/GpMA/KI~ARUK _ - ~ b ! O 2. lCY7 ^ Flere ~var~t (mmfdd/yyj (Check Selection) ~MSCF BBLS M' •t'iVCi::.~'::::•:•:::~'~ ~• • •Fd~lgtpanned ^ufiplanned (Check Selection) {L"sbume Only • Gas fla-ed -pes fran ^ u~aeam ^ downstream (Cnscx Orw) of TEG catracror ureter at 1PO} Time of Otxurre ~:~ 29:QQ ~ 1Hinutea From: •~,?,~Q~ To: \`7~ From: To: „~ From: To: _ ~ From: To: _ From: _ To: ~T = From: Ta: - Totat Mlnules Flared: = a~c~ , {Irrdudes vo)ume Eldred which generated black smoke, if applidableJ A. t)esctiplion of Incident 81x1 Cause: (Check as many as needed to fatly describe the Irtddent) __ _ SIDT/C~ for .,...^- 71C SDdue to nigh exhaust temperature _ _ Seel oil system althcukies BrtERGENCY SHUTDOWW • E]ectrical / Instrumentaticn mttlfunction ' Electrical / Inawmenta6on maltuncdon _ at other iaGilky lT&0) ~ ~_ Gas uarteit system overpressure baeldn9 CPFlFlow Station out ~ ' F~caessive / insuNident inlet gas - - - - rates irrio facility • B. Acaon Taxer to Ellmirlate Cause tmd Provost Recurrence: (Check and describe as applicable) Started /restarted TIC e Compressor/tra)ndepressured Raduoed I Increased inlet gee rates Completed flare testing . Corrected E261 fluctuation /failure Carreoted EiLf fluctuation !failure at other faalliiY (Teif7) Bl:ack•Smoke Process upset in section of facility Flaring for grlllsite gtwtgpwrl /startup , Flare system testklg Faulty shutdown on Facility maintenance Migh amdiers temperatures. D or high vibration her. ~Y< . ~ - tl.~ Stabilized faglity process and operatJon Repaired equipment difficulties with Faclliry maintenance corttplete~ , , ~ , Ditl inddent cause black snake? Yes: ^ No: 1~ pf Yes, continue with this section) Did inadent present Tt potential threat to human health or safety? Yes: ^ No: to Yes, report to FEC as soon as possible. H No, repoft td ADEC with 24 hours.) Black smoke emitted from source: (enter tag nurtlber and Description) ' • i Notified ADEC by Fax on: f711e: Time: ' Report the tolktwing information to ADEC within ?A hoursElll FAX (907-265-9508): Date and time of bladt smoke avant: From: To: Volume flared which generated blade smoke Cd different from above): M$CF SB4S Description of steps m migimize emissions: See Ssotlon B. above. Type of materiels burned: Gas: NGLs: Qther: General Weather: Air Temperature: Wlnd3peedlDirection: ' Warne and phone number of person making the report: Name Phone'Nc. Based on information and belief formed after reasonable inquiry, I certify that the statements and informatan in and attached to this document are true, accurate arW compfa~~ , 1y~p/. Faciliky Supervisor ~ - ---~,~~„ Data d ~~Q • RECEIVED NOV 2 1 2000 Alaska Oil & Gas Cons. Commission Anchorage iO-iT-00 06:21 From-ALPINE NSt~T + T-562 P.06/12 F-91T ~/ ~~ FLARS GAS VENTING REPQRT PHILLIPS ALASKA, INC. • PRUDHOE BAY/GpMA/Kl]PARl.1K ; • FACItJiY: A~ ~::.' ("o`C~FERMRNO. 'y~•-~':~F, GAS DISPdS171dN pate of Occurrence: ~ t',~ ^ ~'vent Tlme at Occurrertee: (mrNdd/yy) (Check Selection) ~ ?gam 1, u~t Hums From: Q~b"_~ To: ]~~ m Total Volume Flarsdt ~_MSCF BBLS From: To: ' From: To: a M ~ ~ ~:~:=:~•~•~•~•~••:::: Cq ~ QUnPmmed From: To: _ ~ (Cheek Selection) From: To: ~ ~- From: To: - Total Minutes Fla,atl: = (Lisburne pV:IY- G~ Narep was Jran ^ m Q warn ir~,ecxOnej (Incluo'ss volurrle flare4 yv!>K:f'i g91t9fZ;ted black smoke, a17fGormeN,•atLPCj ifapplicabla) A. PeacrlPtlon of Inektent and Cause: (Check as many as needed t4 fully deacrlbe the Irlclttent) SID TKO for Process upset m _~ T!C SD duct to high e~laust temperature section of tadliry ~,_ :teal ail system t6fliculges Flaring far dnllaire ehutaown(starwp ~ F.MF..FIGENGY SHUTDOWN Flare syaoam testing _ EleCt-'ICSI J Irlsevmentatlcn malNnaion Fanny etwWawn on ~aobtt:al / Inshvmentatlon manuncGOn Facility matntienance at other fadlity (T8D) HIgf1 ambient temperatyryg- C3as tranart system oveipreasure P ~ high vibration Oaolortg CPFIFIOw 13tation out er. -_-- - hrs/ InsutBdent IrNe! gas raise IMO fadlily i~ B. Action Tafean to Elindnata Cause and Prevent Recunartca: (Check and deatxibe as applicable) i Started / r9etart9tl TJC # Stabilized factil' nY Process and operation Corn r/train de reesured ~ ~ presao p psi equipment difflcxtltles - Reduced /increased inlet gas raise with Completed flare testing Fadlity malntenancs co feted Corrected E&I fluetueUon /failure ti r er. ° __ ~ Corrected E&1 ftuOLtaGon / taAurs ~ J at other tactility Cr$p) 1 Black Smoke i Dkt incident cause bladt amoke7 Yes: ^ No: ~, (lf Yes, continue with this sectlon) Did Incfdsnt present a potential fliraat to human health or safety? Yes: ^ No: ^ (It Yes, report to FEC as edCNt as possible. tf Np, report to ADEC with xa hours.) Black smoke emitted frorp source: _ (err tag number and destxiption) Notified ADEC by Faxon: Dais: Time: RepOR tlto Toliowing irdormatlon ro ADEC within ?A hcurs~,~ (9D7,269-750>~: Pate and lima of bfadc smoke ever>x From: To: Volume flared which gertQrated black smoke (if different from above): MSCF 9BLS' DescrlpUon of steps to minintize emissions: See Section s, above. ~_ Type of materials burned: Gas: NGI.s: _ _ Other. General Weather: Air7emperatura: Wind SpesdlDirsctlon: Name and phone number of person making the report: _ ~ Name phone No- Based cn information and belief after reasonable inquiry, I certify that the statements and Irtigrrnation in and attached tQ this document are Vua, accurate ah plate. RECEIVE D FacilA S i ~(~ / ~ ~~Q y uperv sor pats , cc: EOC supervisor, PRB s (flare bleak smoke incidents) ~ N a V ~ 1 000 Ftekt Environmerttaf Co Coordinators, PRB 9 (f3laok Smoke incidents only) PBU/GPMA F'iekl Managers, (Bieck smoke InoideMS only) Alma ~ & ~ ~~ ~~~ GPMA Operations Ertglneermg Technical Aide, (GFMA reports only - qT0 477) ~ Kupartrk: Field ~nvirortmantai Compliance Coordinators, NSK 61 (flare gas and black smoke inClderita) upeatetl: FEC 8100 P.16roupe~HSET~Erwironmentol Help\F4rms~HOre ~ Venltxi r-orm Oe00.be 10-17-00 06:21 From-ALPINE NSfriT + T-562 P.05/12 `•--~ FLARE GAS VENTING flEPORT •~ PHILLIPS ALASKA, INC. • PaUpHQE BAY/GPMA/KUPARUK F-91T FACILITY: /~lp.'~C::,. . '•r.'E~~i~nF.+`.r'~:~:~a~~~-'} PERMfT NO. '~~~~~•' ~.'r;~~'1J-~ !J ~1~:~ GAS DISPOSR7ON Date of occurrence: /G/ 0/[10 _ ^ Frere ~VeM Time of Occurrencc: (mm/ddryy) (Check Selection) ~;9Q ~~Q M notes From: C C~ To: ,C~ = 36•Q Total Volume Flared: 393 lascF BBLS From: To: - _~ From: To: - RM41pF~:ti'•:-::::;::::•:•:::::•::•: ~' :l= it I~rra"ren ^ ~Pmnnm From: To: (CheCK Setectwn} From: T4: _ From: To: - Total Mlntrtts Flared: _ ~ G fi {Llst7urne CM(y -Chas Bared t+~ hrorrt ^ upatrrbm ^ do~mst+eam (L7rvck Orly) (ht4YUd9s viPfN+Tte NarBd rvhlch gerterated.blaclr smolca, of TEG CO/NaCfOI rneeerat LPC) if aPplx~We) A. Description Oi Ineitlent and Cautra: (Ctreck as many as needed to fully tlesoriba iha inCitlOnt) SJD T/G1 for ,,,,-, TIC Sl] tlua t0 high exhaust temperature Seal oil system difficulties ~~ EMI=~iGENCY SIiUTDDWN F~ectr'iaal ! tnstrumentai~on matfunchon Electrioall Instrumentation maltunctton at other tettilny (T&D) Gas trarlslt Sysienl overpmssure ---- DscKinB CPFJFww Station out ~... F.xeesske ! krsr,llicierrt Inlet gas rates into facility B. Action 7aKan to Eliminate Cause and Prevent Recurntno9: (Check and tlasCribe ~ applicable) Started / rsstaRed TIC # T Compressor / train depressured ~'T RerArcetl /increased inlet gas rates Completed flare testing Conaotad E&I fluctuation! failure Corrected E&1 fiuctuatlon /failure at other faclity (TF.P) Black Smoke t'rot:ess upset in ' segkW- of facility Flaring for dfills'ite shuttlown /startup Flare system mating Faulty shutdown on Facility n,aimm~anoe h~ ambient temperatures. . S/D an high vibration Other: ~a,•,,aE..//c%:~.,~r~ J {~,.,.~e,e k ..r9 ~/P~/4 . •. A c~ cr~~-eider - • ~r O~rJ~J~//y.a ~f' ~~ Stablilzad fadlhy process artd operation Repairetl equipment difrrcxlltie~a with Fat:illry maintenance eom/plated Other. Sr~os~c~DT ~ +~v~i~.v ~r~/r w C/tw.+.' tri~ twt ~~ 7 J Did incident cause bladt smoke? Yes: ^ No: [~ (tf Yes, continue wtth this stsctlon) • laid incident present a polantral threat to human health or eatery? Yes:. ^ No: ^ (If Yes. report >fl FCC as soon as possible. K No, report to ADEC with 24 hours.) Black smoke emitted from source: (enter tag number and description) Noi><it3d ADEC by Fax on: Date: Time: RepoA tJ1a following intorrltatlort to ADEC tsith)n 24 houreBY FAX (9E9 26&7Sd~: Date and time of black smoke evatn: From: To: Volume flared which gene-atad black smoke (l~ different trvm above): MSCF ~ BBI.S Description 4f steps fo minimize err~ssions: See Section 8, above. , Type of materials burned: Gas: NGLs: Other: . General Weather. Air Temperature: wnd SpeedlDirection_ Name and phone number of person making the report: Name Phone No. Based on ihfonnation and belief tb r rsasonable Inquiry, l certify that the statements and information in ai document are true, accurate and ate. Facflny Sttparvlsor Date aT ~ ~~ ce; EOC ;wperwsor, PRB t3 (flare gee an smoke inadems) m~this RECEIVED Nov 2 ~ 2oao Alaska Oii & Aar ~Com+tlissw~- 10-17-00 06:20 From-ALPINE NStdT PH Dam of Occurrence: FACIERY: ~~ (~ i t L.l1I IY MI'\V f Y/~ 111•\A \ •ra vs a 15KA. INC. • pAUPHQE BAY/GP J O ~'8 Q p CI ~ I~'ven (mrN ) (Cheat selection) Total Volume Flared: ~~ -[ NtSCF BBLS ... • f.~l ~ Pmrned ^ Unplarlnad (Check Selection) (flsbuR+e OAIY - GSS flere0 was from ^ ^ dow11~9m (Check One} ~ 7~G adrDgq~Drmeteretl.PiG) PEf~NIfC f~lo. T-562 P.04/12 F-917 ~ 24~ From: o'1<_trs 70: {S;1}+~ _ ~ From: To: ~ - From: To: ~ _ - - From: To; t: i From: Ta: ~ _ - - From: To; ( ~- Total MinuEOS Flarod: (rndudes volume flared whlClt generated black smoke, if gppiicaDl9) A. Descrtptlon of Incident aril Cause: (Check as many as needed ~o Italy tlesctlbo the incident) SID TICK for T1C SD due to riigri eo-sust temperature 3e91 oit system difficulties E71tERCENCY StilrTDOUVN E7eetrieai / Instrumentation manurlction _...._..- Ef9ctricat ~ Irtstrumerttation malfunction at Omer tacaigr rr~pi Gas L'ansit system overpressure ~~ ptlGking CPF/Flcw Station out _,,,~_ EfcCBS911re / Irtsu!(CierK irUet g9e ' rates inED fadlity B. Action 7atten to glrrartam Cause and Prevent Rseonartotx (Checlt and deserllre sa applicable) Started /restarted TIC p Compressor /train tleprassured ~~ Reduced / itHxeased inlet grin rates Compered flare testing Corrected E&1 fluctuatwn /failure ~)~ Corrected E811 fis,CU,ation 1 faNure at other factTrry (f&D) Black Smoke Process upset in Section of facility ~ Raring for drillsite shutdovrtl /startup Rare system testing Fauriy Shutdown on Facility maintertanoe filgh arngient OBrrlpBraktre9r SJO on high vibration Qtltar. ~+~I~ `~ ~ I I~ Stabilized facility prof~S~ and operation griretl equiptrtent tlitflCultiAS . with Faaligl mairrtertartce completed Ofher: 5 tre+~>< i i ~~~a-v lei Sl~ t7C _~'i ~ ~ M~~~ Did lnclderrt cause black smoke? Yea: Q No: ~ (If Yes, continue vvatit this traction) Did incident present a pc-ten4ai threat to human health or eafety7 Yes: ^ No• ^ (11 yes, report to FfSC aS soon a6 pwssibNo. R NO, repoR to ADEC vrlth 24 hours.) ~ladc smoke emitted from source: (enter tag number end description) NouGed ADEC by Fax on: Gate' Tima• Roport qte tollotrlirtg irtlDrr11at10n m Af?EC within 24 ttaure@Y FAX (8D7 46S-9S08~ DAte and time of bleat smoke event From: To: ' Volume flared which generated bleat enl0ke (r~ different from above): _ _ MSGF SSt-S Description of steps w Ittinintlze etnltts)ons: See Section B, above. ' Type of materials Domed: Gas: NGLs: Other. General Weather. Air Temperawre: Wind SpesdlDlrection: Name and phone number of person making the report: Name Phone No. Based on information and beAef formed after reasonable inquiry, I oertlfy that the statements and infonrtaticn in and attached tp this dcra,rrlent are we, aca,rrate an plate. FacilitySty>!ery~ ~ _~_~ ~ fla , oa: t:OC SupeMSOy PRB B ( ae and black smoke incidents) . Field Environmental C pliance Cocrdnatdrs PRB 7 (Bleat Smoke inadents only) ~~~C'\ /~p l~S?171ri7i ~~, ~ ~~,r, i i ,,..: f ., .. .'''.:; ~, ... n ~.~~ G V i ~ . . I ' .... - ... .. ':-: NOV 2 1 2000 Alaska Oil & ~ COr~~ 10-17-00 06:20 Fran-ALPINE NSb1T T-562 P.03/12 F-917 `• ~./ FLARE GAS VENTING REPORT ~ PHILLIP~~S// ALASKA, _IyN~G,.A• PRUDHOE $AY/GPMAIKUPARUK i FACILITY: ..~fz!~~%>~/~~ PERMtT NO. :~:~:~4~-: ~: GAS DISPOS1170N Date of Occurrence: ~p i! [If~,e ~rnt { mlddlyy} (Check 5alection) Total Volume Flared: 35~ MSCF BBI.s (Check Selection) (t.IsDUma t7rtlY - Cias flared was !rom ^ up60~m Q ~" ( ~! of TEG oontacfor-neter at tPC) I Time of dccurrencc- , Minutes 2g;Q~l From: :pU To: ~~p'-4!t~ _ `~t-- From: To: _ From: To: _ From: To: ~_,_„^ ~^ From: To: _ From: To: = Total Mlntttes Flared: - (lnG1LILi951/t7/Ltrtte fTdrt9rf tiVhk`.!1 generated wok Sm4Ke, 1t appllcaWej i A Description Gf Intigent and Canso: (Chmtlc as many as needed to Tufly dearxibe the Inciderri) S!1? T/C,t for TPG SD qua to nigh e><hauet temperature Seal oit tystsm tlilfiCUlpes EMER46Nt;Y SHUTDOWN _ ~ecVlcal /Instrumentation malfunction Qectrical ! instn,mentanon rrtaNunctwn at other fapliH (TaD) ,__ - Gas transit system overpressure baddng CPFlROw Station out '~ Baoesaive / insufficient inlet gas rates ir-to tadlky B. Aetlon Taken to FJlmlrreto Cause any Prevent Recurrence: (Check and describe as applitabie) Started /restarted T!C ti Compressor /train depressured Reduced /increased inlet gas rates ~~ Corrtpieted flare testing Corrected F~,t ftuCtuation / failure Corrected EF~1 fluctuation !failure at other facility Cr&D) Blade Smoke Process upset in secctinon of tacilily Flafinq for dAnslt® shutdown llstartup Flare system testing Fauigr tihutdown on _ Fattility maintenance High ambient temperan,,res. S/D oq high vibration Omer. ill t.CDap/~Gf.~iiM}uP~F4y~>~~- dF GDf-~ ~ P~O~-ot~ ~,t"ItR.-Z" 't1LQ- --- ------ Stabilized fadlity process and operation Repaired equlpmertt difPajttiss with ~ Fadlity mairtte ante completed Other: t,~(~~G.~Nd p f ~C.O~ t3AcG ~ Gnt- F~e~. F~ Did incident cause blade smoke? Yes: ~ No: '~ (If Yes. continue with this section) Did irtctdant present a potential threat to human health or safety? Yea: ^ No: ~ i (If Yes. report tD FEC as soon as possible. fi No, report to ADEC wRh 24 hours.) Blade smoke emitted iron source: _ (enter tag number and dasarlptlon) i Notified ADEC by Fax on: Date: Time: . Report the following infarmaaan fD ADEC wtmtn 24 hoursBY FAX {9p7.26$-7508): Data and rune of blade smoke event: From: To: Volume flared which generated ttladc smoke (if dilierent from above): MSCF - - - - BBLSi Description of steps to minimize emissions: See Sectftm B, above. ~ 'type of materials burned: Gas: NGLS: Other: -- -- - Gene+~al Weather. Air Temperature: Wind SpeedfDiractiert: . Name and phone number of person making the report: - Name Phony No. Based on information and belies formed after reasonable inquiry, I certliy that the statements and information in and attached ~ C I V E D Document an: true, ar~ttrate and tempi e. ~ G FaeNitySupervisor pate 1~ 6i q N~~ ~ ~ L~00 ~ F sor, PRB 6 (flare gas and blade smoke inettlertis) f=ield Environmental Compliance Coordinators, PRS 7 {BIacK Smoke inddents only) Adatk~ ~ ~ 1Otf>fTl~ PBU/GPMA Field Managers, (gladt smoke lnddents only) GPMA t7perations Engineering Technical Aide, (GPMA reports ony - ATO 477) Kup~ruk: Field Environmental Compliance Coondnators, NSK 81 (flare gas and black smoke incidents) UPre~~ FEC lilOli P.16rouGSItISE'r16tvlronrr~entCd Iir~plFoomsl R•Gob G~d'iA7~t S Rare ~ RepertFo,rn-xis 10-17-00 06:20 Fran-ALPINE NSUT ~SKA. INC. • PRUDHOE 16AY/GP T-562 P.02 F-917 I FACILITY: ~~~~:~~.P~A~ PEi2fWITAlO. -::~~N•:tia~~~~f.•~ GA$ DISPOSITION Date of occurrence; 10 f l~{ pip ^ F~ ~ vg,~ (rrtAl/ddyy) (Check $eledion) Total Volume Flared: ~ ~~ MSCF BBLS (Check Selection) {1.irawme OMy - C3as Ranttl was front ^ upsca~rn ^ 4awn~rearn fcnec><t+naJ of rl:G oorrradar'-neteratl.RC) Time of occurrence- ~ From: ~ 00 To: J7~ ~ ~'S From: To: ~,•, From: To: - Frurr-: To: _ From: _ To: ~.T - From: To: _ ,_ e+ Total Minutes Flared: a ~?'.i ryrtclutles volume flared which garre-ata~bh3ck Smoke, if applicabl9) . A Description Gr Incident arxt Cauca: (G~reck as marry as rtaedep re turfy describe the irlCldant) _ S-D T/CA for TIC SD due to ht$h exhaust temperature ~- Seel on system d'effiCUl6as _ EMERGQVCY 3Hta'1'DDwN F-lectrtoal / trtstrumentatbn rnallurtction ~'T Eieouical / Irrstrumertitaticn ntalfundion at other fadlity fTEA) Qas transit system overpressure ttadcing CPFIFIow station out "~ l~asshre / ineufficierR irdet gas ~~ • rates into fadl2y 8. ACtIr>n Taken id Elintirtera Callas arM Prevent Recurrence: (tWhacl: and dasoHde as applicable) Started / restarted T/G # Compressor / train depr+essured Reduced 1 inCr9ased inlet gas rates Completed flare testing Corrected E&I fluctuation /failure ~_ t,'.orratxed R81 fluctuation /failure st other faality (T&D) Black Smoke i Process upset in seCtloflOf taClthY Flaring for drdisita SF'lutdovvr- /startup Fiats system te8dr18 Faulty stw,tdown on Facil'ny maintenance Fliph ambferrt temperatures. , SID on high vibration other: a„bJs,~.~P f i~.orlB~ck ~ Lipf+ Ica! LQR ~~.. Stabl112ed facility process;attd operatiw~+ tiepain~d equipment dfiflcuhies with Fadligr maintenance txxnpieted Other: Fuha-a~AerC GAMPI~ MllTti YJ~G. ~G . S ~• Did incident aortae black smoke? Yes: © No: ~ (lf Yes, continue with this section) ' Did incident present a patertflai threat tD human health or rafary? Yes: ^ No: ^ (M Yes, report fu FEC as soon as possible. K No, report to ApBC wrTh 24 hours.) Black smoke emitted horn source: (artier tag number and description) Noflfled ADEC by Faxon: Data: Time: Report Ure Idlotrring infortaatlerr tp ApEC within 24 hourat3Y FAX (9W~59-750ti)e ~ Date and time of dladt smoke everts: From: To: ' Volume flared which Aatterated btdck Sn1oK8 (tt different from above): MSCF ~BBL£ Description of steps to minimixs emissions: See Sectiatt S, +ttbrfv~a. • 'f ype of materiels burrtedf Gas: NGLs: Other. Qeneral WealNar. Air Temperature: Wind Speed/Dirediorl: • Name and phone number of pert;•on makinD the report Nettle Phone No. Based on information and belief fom~ed after reasonable inquiry, I certify filar the statements and irtfomtation in and attached to this document are true, accurate and compl~;le ,t Fertility sap9f~risor f~. -",J'~~,1„6"_ - ~ ~ ~r o~ E~ E IV ED cC: EQC Supervisor, PRB 6 {flare gas and black smoke inddents) i '~) Car ^rfSrs~t'iAtftrl x^nrnnl-nnrn ~:onrcrrr ^t4rR f~Rfi 7 (t3lnch smcllca Pn~rir`rrS*s only? NOU 2 1 ?.000 Alaska 0+1 & ~~°mn"ssi°n 10-19-00 13:27 Date of Qccurronce: From-ALPINE NSf~1T rt.Alrt;t: UAS VENTING REPORT ~SKA, INC. • RRUDH~E BAV/t~Di FACItJTY; .~;.~~~~•~F~~~Yt'IF-N7 PERMR Nb. ),7 / ~ o 1~Fiare ~Ivent (~ d/yy) (Check Selection) To'idl Volume Flared: ~MSCF ggl..8 Mlttaa: ':;:::': • :I~ii& ~1 Plamled ^ unplarmsd (Gheck SelACtion) T-668 P.OZ/02 F-055 lime of t7ecurren ~ Q4:Q(? ~~ AM~nu From: t ' G 7a: <' '~3~ From: To: - ~ From: _ To: _ From: To: - From: To: From: ~ To; ~ _ Total Minutes Flared: I (1Jslwme t?My - C,1as flereC was from ^ ^ dowristrwrm (Crtr~ per) of TEG aavttactormeter' ar LPC) (lndirdes volume Jiarea wtltch i gsneraied back smoke, ifapplir,~lej 11. Deacrlptfon of lricltlem and Cause: (Check ais marry ae naetlad m fully tlescribe ttio incident) `~ t3/D Tice _ fPr T1C Sp tlue to high exhaust temperdturo ~^- ~_ t3eel oil System oiniCUhies ~~ EMERGF~It;Y SHUTDQUVN Electrical ~ Instrumentation malitincroon ~'i ~~ Faedtioal / Instrumentation maliurldion at shat fadlity (Tao) '~' Gas transit system overpressure `-' tracking CFF/Ftow Station out ~"'+~ Exoee6lVe / irisunicierit Ir11et gas fates into faality 8. Action Taken to Elimin(3te Cause and Prevent RecurrenCO: (Gheok entl describe as applicabto) ^_ Started /restarted TIC tF ^~ Compressor /main depressunscf `-'- ~^ Reduced /increased Inlet gas rates `~ Completed flare testing _„ Corrected E&I fluotuation /failure -+ -- Gonected E8! flutSUatlon! failure at other facility iT&D) Black Smoke Process upset in section of facility Flaring for dnlisit9 stwtgoWn / aranup Flare gygiem testing Faulty shutdown on Facility msintenarrce Nign amolent temperatures. ~ S/p on high vibration Other: UIJtt7 ~C~~ ti„r$~ i ~~~f~t A I stabilized fadliti process and operation Repaired equipment dlffiCUlties with Facility maintenance c plated Outer. ~ rt _ ! pid incident cause black smoke? Yea: ^ No: ~ (If Yes, oominue with this section) Did irlCident present a potential threat to human health or safety? Yea: ^ No: ^ (if Yes, report to FEC as Soon as possible. M No, report to ApEC with 24 hours.) Black smoke emitted faun source: (enter tag number and description) • NoG6pd ADEC by Faxon: pate: Trine: Report the tdlCWlilg ietormtttlon b ADEC within 24 hours~FAX (80769.7508); Date and time of tNack smoke event: From: To: Volume flared which geg8rdted black smoke {if different from above): MSCF t36L8 ~ pescriptign of steps tv miniml=e emissions: See Section B, above. `~ Type of materials burned: Gas: NGLs: Other: _ General weather: Air Temperature: Wind Spsedlpirection: I Name and phone number of person making the report: I Name Phone Nc. Based on infonnatton and belief forrrlsd after reasonable inquiry, I certify that the statements and informat,'on in and at~che¢M~tlviel C E I V E L,l document are true. aoatrate ate. r,( C Facility SupervtSgr Date ~ ~ .~ ~ • cc: EOC Supervisor, P tiara gas and black smok® incidenns) N ~ V ~ 1 ZOO O Field Environments Compliance Coordinators, PR13 7 (Bradt Smoke incidents only) PBUKiPMA Feld Maftagers, (Bradt smoke inciderris only) Alaska ON & Gas Cons. Commission GPMA Operauans Engineering Technical Aide, {GPMA reports ony - AT'O 477) Anchorage Kuperuk: Feld Environmental Compliance Coordinators, NSK 87 (flare gas and blade smoke indgents} UPdalesx FF_C aro4 R1CrouPS\HSET~EnVI(Qnn9dr71pi HetplFOmwIR'-0Ob Ertlnibit B Fiore! Gas f~portFOrm,~ds 10-21-00 12:54 From-ALPINE NS~IT i?Ntit.~t~S iFf`.ARE GA5 VEN I IN[s Ktr'vr[ ~ ,ctcs_ iNC_ • PRUt]HCE BAYIGF FACILITY: ~l~' '-~r'~~~~~~:~:~'ll~~i)±N~ T-T78 P.02/02 F-195 p'ERMffND. ~:~7'~w:~'-~~' ~ c+f is 20 o v ~7ven< (mmld (Check SeleCtign) Tonal Volume platwd: ~'p0 MSCF _~SetS ::•::: ; :::::; •::: • .r•`~iGt O yea ^ unpwn~ (Check SeleatlOn) {t,+sbuua cMly- Gas Hasa was rron, ^ ^ aowns~n one of rr:G aar(actormat~at LPCJ rxne of fie:, Fran: le; a0 Ta d~': = 25 Fran: ~_ Ta ~_ - _,_,.~ From: _ Ta .~ _ --~- From: Ta = ^,.. From: ~ Ta ,~,~ ~ _„^._. Fran: ,.,- Ta ~_ ~~ Totet lYNnutea Ftarod: = (~ 8ersal generatrad t>viad~c smoke. ~~~ A, pescriptlon of ~ and Cause: (t:t~edr as many as Headed m inmr descr~s the k>c~nq _ _ SID TIGi~ for -.., - T/C SD due io ~ a~erast tentparatur+a ~! Se91 Cl sYetaM dHriculhas ~-- ~- EMERGENCY SHl3TDQWht -.-- ~~! 1 / 4~sMUnrerte~ maKuncLan -~ Elec~ical / krebumerrtelian meifunpion ~-. ~~ st otharisciiity (TB,D) ---~- ct~ tar>9it eystern ~ -~.~ ~- bsekinq CPF1FIvw Staeion art insutbcient inlet gas ~- raoas into factbiy 8. Action Taken tD ElGntnabeS feslgted TICK ~~~. (Check antl deaerttle as aPt~ble} -'~- Camproesor f train depredsgrad Reduced / 4raeeeed inlet gee rates "'~ Computed flub testing "~'" Gorr+errted E81 #IlicSuation 1 failure ~.~ ~~ Cprtibcted ELI tlu~uation 1 failure "~~ at other faciidY (T'&D) Volume flared wtgcdr 9eltere<ed black smdae (tl --~--~ p~giptiort d steps to minkttae etnissiaw: See Secttdn f3, a~baYe. Ottrer Type of rrtateriats burned: Gas: NG~' ~~ CserierM Weather: AtrTemperature: _ Wind SpeedlDiredior+: ^ . Nana and phone nurnbsr d peraat rttaking the report tJatne Phone No. Q Date and time d t~{9dc sntdte sean>" From. . it (fFererrt from abwej' MSDF ,~_ t381S Prvoeas upaeR in aeclion oriaGility FlsAerg {Pr dfill~ts stxrOdown I sterti+P Fte~a system tssGng Fault' ehutciawn on Fecaity mainlsnarlCe Migh en~bier-ttemPa'murers• ~ SID cn high vdxation Other: 1.Inlt-~iD,~,~ ~ t ~ F it ~Y $tabrlaed fatdleY process ancf aI>e~i0r1 Repaked equipment cflHiwlties vdlh ' Faer~y ~ com ~ e_.v Outer. ~ B 3mo e ~ Dantinue weh this section) Did irtctdertt cause ttlac:k stttoke7 Yes: 0 No: ~ (if Y Yom: ~] No: pid irrCiderd preterit a p thr~t to twrrae, health ar safety? , (V Yeg. naport >n FFC ~ soon as podelble. i< tYo~ report to ADiEC with 24 hours.) ( ~ number and desCriptlan) Blade smoke emoted from sottrc~ Tom: Nd8'ied ADC try Fax an: Data .a8g 7SOay. Reps q~s faUOeryq hrlareretion to ADF:G wlfhln u twure . 1tt07 Ttr Salad on irrforttt2tiortand belief formed aRer reasclnab161nQuiry. I certify that the stetelrrerrls and infarrnatton in atxt anact-e~tprs C E I V E D document are true, aaa+rate artd ~"[ C oaoe t 4 ~ ~ F~cllity Sgpervle0r r N O U 2 1 2 0 0 0 t:~ HOC Supetyisor, pRB s ( sold t>led< sntake incidents) Field Ernnronmemai comdiance Cocrderators, PRB 7 iBaack Smdca ineidertts onh4 Alaska Oii & Gas Cons. Commission PBW'GPMA Field Marretgara, (Black atnclos incidents ony) GpM/1 pppatiats Errgitteerirty Technr~ Aide, t©PMA eeP°BS °Ay - Aro 47~ Anchorage KupBnsc Field Envitortntsrttal Carrrpfiet>re Caadiftamors, NSIC Si (tiara gas ar-d 61eCit Srrteloe incidents) 10-23-00 09:53 From-ALPINE NSNT AKA, INC. + PIZUDMOI` BAYIGF FACILITY: 1~1~;~:~~':~~~~.~~~El'~Y IPERMrt NO. :~~t~~:~:~~r~':4d~::~~:~ t]abe of t~currenee: i e~ z b o D tare ~ vane (mm 10lyy} (Check seis[:tion) Total Voltwne Ffaa~so: 'Z.~ 3 MSCF BSt.S -~,. Meter. ~'.•::.•.:.;.•.:•:.•.•:.•. .•F~ici D i~iannea (:7 unpFatlned (ClleCk Selection) (Lis~me anfy -Gas flared was from Q up~earr- C~ downstream lcneclc one} ov 7EG cont~or rrre6Bret I,PC) Tltnt3 df taccurrence• ~ ~- Fran: ~ 8• r Ta ~.t~3~ _ ~~.5 From: Ta = From: Ta. Frain: '~ 7a : - Fromr __ Tar = From: Ta - Total AlsnuESe Flared: _ ~: -~. (6tck,olos vvGgne ltersd ~vhwyl ~ ) a Descry a1 lrloldent:nd Cause: (check ae marry as rreseea to fuay describe the Irroldarrq 5ID T!L'ix -- _ _ - for ~.._.._ Frviceas M _ - - - _ T/C sb due to tugn a~ausr ternvarature sectlan a ra~iity ~_ Seat oil system diRi~e' s ~^ Ft~r~ is dr~tsire sIwSUOMm l staAup FJ~iF..RGI~ICY SHUTOdYVN ~ Flare sYetem tearing Fleeciest 1 tnslrumardation meilfunction _ _ FatNgl aheytdown on Oeotricai ! Ineuumerttation maKundion Fec~lity matrtterranoe' at wt+ar tardligr (TQD) high ambient tamperaihner¢, Gas transit system o+erpreaerrre ~ ~ S1D on high vdxatihn t-addr~ CPF/Florv Station cut ~ Ottwsr: lit~IL.aAI?~C,Rk~ll ~ 1=L0W 8f~t.JC -- _ -- _ l3aoassfv~a ! krsuaicient i»iet 9~ c`9 ~' ~ (, ~ ~!'8 `t W ratesirilofaolity ~b~ S~i4RT U~ t3. ACGon Taksn tD EtiiMir>aLV Cause end Pfpwnt Recunenca: (Chock antl describe as applicable) Started 1 restarted TJC # Stab~imed fagSy prooe6s and aperatian Comptesoar /bait depressUred ~ Repelled equtt dirficultiae Reduced ! increased inlet gas fates 1Nilti ~ Gomplets0 flare testing Facility mafnterience completed Corrected t-8l fluctuation / faibae ~ Other: '~'f al~1z~ WN ph1 in) ~I.L Corrected FBI flttctuadon / feAure ~ s W E 0 S•L ~N ~ ~ C-1.~1f1~1'-~ G at aver facir'gr (TSD) a ~ ~r~ a,~ ~ w G t]id incident Cause htadt smoke? Yes: D No: i,~ (If Yes, aantirrue with this stsrtipl1) Did incident present a pderttial thre9t to hwnen Frearih or safety? Yes: Q No: D (If Yes, report to FEC as soon as po~ltfle. If No, feport to AI]SC with ?A hours.) Blade stnoiae emitted from solace: {eater ~ number and desatiption) NcdFieO ADEC by Fmt ai: Date: Tuna: Import rile foltowhrg Irrfarnatlolt to AOEC arghin 24 hours aY FAX Se0~7~e8.7~: i~ arts tir„e a hiaiclc smolae evefit: From: T« Vaiume flared which gerie-ated Mack anroke ffi different from scare): MSCF ~ Bl3I~S pesc~iort of steps to ttrinirtnze emissions: See Seaton e, above. '~ Type d meteriale bitnteA: Gag: NGIs: ottrer: Gertetai Weather: Air Temperature' Wind Spaed/Dlrecdarr Name and phone number oIP person malting the report: Name I Phone No. 88580 On IrlfOrrriatlOn aril! belief }Om12d after reesoneble N1QUIry, I Certify that the 5[at9rrrents and 'irrfartrratlOn in and atlaCtleO to this ~~~~ :RECEIVED Facility supervisor care to 2..2. ~ ~ cc: Eoc srar,1~R6 ~ era bleak srnoke:rcidents) N 0 V 2 1 ? 000 Fajld Environrrrentai Caordaratas, PRB 9 (Blade Smoke incidents orrty) PBUlGPMA Fold , (13fadc smoke frrdderrts only) GPMA Oparebarrs Er>giieering Technical Akre, (GPMA reports entry - ATO 477) Alaska Oil & Gas Cons. Commission Kupan~lc Field Erniironmetttal CCrtlpFance Caardinr:iit, NSK 6Z (flars~ gee 6Iactc 6~rftvlGe irx:i~€mt?) AnChoragt' T-879 P.02/02 F-316 11-02-00 09:34 From-ALPINE NSNR + T-298 P.O6/O6 F-894 ',.i FLARI! taAti VCP1111MIs KCI"~JKI PHIWPS ALASKA. INC. • PRUCIHOE BAYlGPMI~tlCUPARUK ~ - -- __ FACILITY= ~~J~~~:~:~E~'~~P~LGV+ tR Nt,. :::i~b :i*1:::::: i Tune of Oc+curreette• I Frain: ! -3: oa .~.~ ° ! S~? - ~2: (SD P+- To: From: Ta ---- - - Fran: Ta ~„^ Frain: ~,_, To: ~_ - ,~.-~- From: ~ Ta ` ,..^~ - fl¢ Total lN;n~as Flared: px~fes fr~rea wfach ger~rated srrwke, ~) t of Occurrence: jp ~~ ~d ~ flare C~Vent (mrYtldd/yy} (Ci1eeK Selection) Tatei Volume Flared: ~~~ _MSCF BBL.S eLBt`FI'o.:•'-'•'~ ~'~:~:~:~::~::::. ' :~ l~,Planned ©Unp~rned (Check Selection) {eianume Ctr+h- cas narerl waa mlm ~ uP~aearn ~ downsd'edm f o+,o) of TEG oor>taetor meter at LPC) A Deacr9ptlon of Irreiclerrt artd iaue+: (Check ae marry as Waded ao frttbr ~s,mr~ the ktcidenq S1Q TAC# fat TlC SD duB to trlgh a~dlaust temperature ~~ Seal oil syatenn dllfiarltiea ~- EMERGENCYSNUTDdWN - -- ~~ ElacAri~l t ~ymentslion malfuncilan Eleprical / Lxnrt,mentation melrunetion ~, ~~ at alner laaliW (T8D) _! Gas trsreSit sysFe-n overpYBSSUre haddr~ GPF/FlowStatlat art Emissive J in9trthrae++t inlet qea ~- tines into fadilQl i ProCesa UPeet in sarAOn of faaligr Flaring far drillSil9 shutdowrn / sta,tuP Flare System testing Fealty shuklawn cn Facility maintenance Fllgh ambienttetnpaf~lureS. I S1D on high v~raflQtt Qther: IJP B. Ads Taken to Eiiatifmte t;atrae and Pnaverd Reuarsrtco: (Check and describe as aPplicaBla) StBrT@d /restarted TIG # ~ $bbl~ed ta~cai4- pnaoees and operation -~---~- ~ J fiant ilred ettu tlHfiCUltlea -~_ RBdUCed 1 irtcroaised inlet ~s rat6S w>dl . Completed flare FacifRy mainterranoe completed Ganeded E$d fklCttl8tl0rl /failure _~ ,~~~~,.~~a. Cortr3G6sd E81 flu4MAtalion !failure •t~ ~ ..--.-- at ether idcllt'ty (F81)) - pid inai0ertt c:auss bklt"ae smoke~T Yes: 0 Ne: ~ (If Yes, t~rttinue with th's seCtiOft) Old ktciderrt present a potendai threat to human health or safety? Yes: D Na: (N Yes;, tepart ~ iFEC as scan as poasibte. tf f~to, report to ADEC with 24 hout~3.) ~~ ~ number and } Blsdc smoke emitlrad fran source: ( Notified AoEC by Fit on: Date: Tirr~ Repplt Una foaawk~g hHeraration to ADEC within Z4ltotrrs @Y FAX fstf7s68-7608): pate and time at t>I~k smoke ever,!: From: Ta Vdurlle flared which 9er>~'a~ ~ smoke (tf d'dferertt horn above): MSCF ~ BBLS ..,.~- Descdptlen of steps tie mgtimmer emlesions: See Seetfaet B~ aitove. Type of maoeriels bunted:. Gas: NGLS: _ Cuter. General Weather Air Temperatw~e: Wind $p~~~' ,,.~.- Nameand phone number df Pe-son making the report: ~ Pttorre No. Narrie BA3ed on IrlfOriTtatiarl end be6eF farmed after reasonabl8 inquiry,. l certify that the staterrterrts arw imamratrwt rn ~ ~.~~+ w W+w doCUrn~tt are true. a and canplete. Qa~a rods ao ' Facill~ $upaevl~r --- RECEIVED NOV 2 1 ?~~~ Alaska Oil & Gas Cons. Commissbn Anchorage 11-02-00 09:33 From-ALPINE NSNT + T-298 P.05/O6 F-894 ~ iFLA,Kt I~P17i vtn ~ tnu r~crwrRr PHILLIPS ALAS INC. • PRUDHQE BAYIGPMA7~UPARUK :.~~: ~' ~ FACILITY: [iari5s of ocratrrence: lb 1.fa tfb ^ t~ ~'ver< (m ddlyy) (Check Selerxion) Taial Volume Flar6d: ~fMSCF BBI.S ~, Plmtndtl ^ Unplanned (Check Spiectlon) (t;sbume Only- Gab i7ared was tram ~ npn Q doMmatream (C~xxk Otte) of 7EG owtfactormaterai: Liacj Time of ~cy~ rrertsa3:_ S~~ 2+4~ iiE Frain: ll:vQ To: 1~~ = Z~ ...-- ~- ~- Fran: _ Ta. ' Fran: ~ Ta ~_ = ~~ Frain: ,,,~ To: ~ _ From: Ta ~.,,_ ° ._, Total Minutes Ftargd: _ - - (Jr1es vClum9 i~a-ed which itappiiMxrbls) A oescNptioe of Inckierrt and Cause: (Check as maa!- as Headed m ttdh- eescrlbe the inciderrQ S1D TACK far ....~~ T1C SQ tlue Ta hlgh eodta,st lempetaiure ~~ See1 oil system dl(NaAtiss .,-_-., !~ FNIERGt~1CY SHUTDOWN ~~ F7eCSitsl I lnBMtrrrertlati0n rnetrunctbn !~ FJecCiGa{ / lrra6urnertletiorl nrettunction _„~_ atau,eriadtit!-(T8D) cas trer~eit amore ~ -~ Decfdr>Q CPFIFIarv ShKion out eve / inauihc~ent inlet gee T~ rates iMo ~Cifiq B. Acton Taken to E.INnittam Cause and Provsrrt RpcunrmlCe: (Check and Asscrihe es appikstrie} Started /restarted T1C ~ ~- Gompressar /train depressured ~~ Reduced J itcreesed inlet gas rates ~~ Campkt09d yare '~"~ Gornected €8~1 iklctrratiarr 1 failure ?'~ ~""~- Corrected Fri iktquatiort I fedora sit outer faci>i<y f r&C) Process upset in sedian orfaeilily ~ Flaring to drs shtilrlovm !startup Flare system lasting Faui~r shutdown on Fecilfty rnsinrBtrw~ce High emtrient ttsnparaturee- SiD on high viWation Cater: J~~L,LMID i,~.Ar3tt~+ FCAutBA[.K (A1 P ~T'Aar• uP ~ -- staDkhAed faetirgy proCeSS ar-d aQerati0rl Repsued ettulprrteM dilficulGes wih Facility mairttatartce comp~ad Other: ~bPFELt u1~t~-t1 ~~ BIaCk Smog Did incident cause bled( Sntdte? Yes; 0 No: ~ (tf Yes, continue with this section) ~ Oka incident present a patertfiet threat io human he~ttr or Salely~ Yes: I:3 No: ^ (1! Yes, report b Ff~ as soon as possible. (i No, report t0 At]EC with 7A hours.) ( ~ number and description) Black smoke amkted from soura~ NaRit"ied Ap~C by Fax an: Data _, Time: Rspurl the foso~rprg Irrlarrr~etlon to APE( vWthbr 2, hours `SAX (807 289.750a): pate and time of 1#ladt smolae etisttt: Front: 7a Ydume flared which generakad bk'i#c smoke (if diFfererd from above): ~_ ~'~ BBLS pption of steps to tninkniae enitssicns: Sea SaCdon B, above. ~~ Type of m2der~ burned: Gas: IVGLS: ~,~, Geiterai weadtrx: Air Temperature:.__.^~ w~ra SPe~~': , Name and t~Fta4e tttartbar of person making ~e report.• ; Ftrone Na Name Based crt irrfomldtior- and bellefi tainted afar reasonebte itt4uiro, l SKY that the s~ an0 infornerttort in and 2ttactted w this tlocumen- are sue, accurate and complete. - ~ t>at~ Jbj~~oo -- padtth- Supervisor R~ C E I VE D --- - ~~ NOV 2 1 2~~0 Alaska 011 & Gas Cons. Commission Anchorage 11-02-00 09:33 Frorn-ALPINE NSNIT + T-298 P.04/06 F-894 rLacc ~,~ venln.a ~r-~,~~ PMICGPS ALASiKA. lldC. • PRUDMQE BAYIGPMI~ICUPARUK _ _ __ FACILRY: f.!!!~~~'~~~~` PERMIT NO. ...~~=~'•i:'et~:~ Dame of OcCUrreittecaa ~~ ~' ~ i7 Rare ~Yent (rrmYddlyy) (Cttedc Selection) Told Volume Flared: MSCF 1381.S Iflieter. '~'='~:~::•:•:~~:::::(~•F~cl ~'}:::~::;_ mad ^lMrplenr~ed (Check Selection {L.iatwme Onh- cos flared was tinm ^ ul»ean+ ^ aowrutnaam {CheGC one of TFC metarai! LF-C) Desexiptiort of steps io ttlBturriae emfss"tans: See Sedlott Br above. Type of tnederials termed: Gag: PIGLS' _ _ plhar: General Weather: Air 7emperaterre: ~ Wind SpsedlQirecticn: Name end phone number of perscil making the report: Name Phone No. i ~t1~ ' ?~ t t=ram: ~ To: , ~7ead _ _ ~~ From: _ Ta ~_ - Prom: Ta: _ Frarrl: Tas - prom: To: 1=rom: ~ To: ° ______ Total Mlnutss Ffer96: = (blCkidi9s vogane flared tNfrich generaletl bJaok SM1oke, if appiCablb) A- DasaApebn or InCitlsnt aced Cause: {Check as many ae deeded to fuey deaeribe the int~arey . 3l[,) TICtF far '~'~ Process upseR in T1C SD due to high ead-aust semparakme ~~ oecuon o(iacit~/ _ Seal ae system dif6cul6es ~- Flaring for drr~isils shutdov+m ! 9tartuR EMERGENCY SHUTpOwN ~ ~++e system Leegir~9 flettrieai l Inshumerltadon matfApuiian Faulty shuklown on ~+ Eletlriral /Instrumentation melfurtc:0on F~tY ~ at other ~h t7'~) ~ Huh ambient temmpetatures. c~ transit ~, re .~ ~ S ao high v~rati t>ec~ CPFIFIaMV stedon out Clther: pmessive / Trent Inlet ens ~ ~ ~ T Hales info fadiigi B. Action Taken ib t=Jimitlate Canso and Prevent Recurrence: (CIrCK cad describe as applkattley) Started ! restarted TIC ~ ~_ Slabirized fac~- proems attd Operation ~- CampresaOr / tree deprassur+eat ~~ Repaired equipment ~~ Reduced ! inrree$ed Gei6t gas rates Completed flare testing + Faoildy mak-tenance corrrpleted Cate:tdeQ ~&1 fltrexuatiart I faiUn~e ~ ~ Qther: ~ Gorrrl<.'tad E8~1 fluctttatrort / fdiluiiBr / W+ ~ ~ 8t other farnliy (T8c~t) • tack Sm qid irwident cause t>{aclc srtroke? Yes: ^ No: ~ {ff Yea, ooRtinue wilts this section) ^ Did incident proeant a potential threat to human heettll or safes Yes: ^ Iva: {If Yea, report too Ft;x as soon as possible. ff llfo. report to ADt-C with ~4 hoots.) t3latde smolre emitted from saeue~ (ereter tag number and description) NatiFed ADEC by Faxon: Date: Time: ' Report tl,s following ItMonrrelfon>vo ADEC rriflNrt ~t Route ~ (g07,268.~;leey. lie and thrre of bladC att~ aran>; Frpn: To: Volume flared which genereled black smoke (d dlFfarerlt from ato+ie): MSGF ~_ t~LS l3aSed an intam~auatt Gild ttei~lfaltted atler re~eisortable inquiry. l ~,r~t~t tne~ ~° "~°`~"°" •' ~`~' ~`~"~~C E IVE D doe~.rrrtertt ~~true, a~a I- Faolllty Supeervisor _~ lJate $? ~ ~ ~ PRB 6 (fk'pe gas and btdck 8rttoioe ert:idents) ~ N O V 2 1 Fuld Emdrexanerttal Campfiarice Caordirlatars, PRB 7 (t3lack Smoke incidents txNy) PBUIGPIuIA Field Managers. (i3lack smoloe aeciderrfss anh-) Alaska Oil & Gas Cons. Commission GPMA Operations Engineering Technical Aide, (C3PMA reports any - ATQ 477) Anchorage Kupatuk: Field Envlrannletttel Compliance C.aotelinBtols, NSK 67 (f Ia1B gag grad 151dGc stt~olae irt~idertta) 11-U2-00 09:32 From-ALPINE NSfwiT + T-298 P.03/O6 F-894 FLARE GAS v>rn ~ 1lvV rc~rtm p n 1 1as e1 eslce ltvc_ . aRUGHee t3AYIGR1rrJKUPARUK FacILr1Y: A..1~.;.:~ ~ . •' y~f>~ PERMIIT No_ :=~~~:~~~1.:~c := GAS DISt~051710N . l~ of t'accurrertce: ~D ~ ~ a r~ iSverrc Thne of t]crttrrence:. (m ~YY) (Check Selection) ~ 8 INl From: 0' T0: !5~ ~~ Total Volume Flared: ~I l MSCF BBI.v Fran: ~ Ta per; To: ' ~f~fo.::•:::~ ~'~:~:~:= •:.:::: ~ PIE»tned ©ur~ptatned Flom: w~_ To: (Check Selection) Frorrl: To: I = From: ~^ Ttx T _„ Total Minutes Flared: _ ~ $')a _ _ (Usbume only- lies itsred was Irwn ^ upse~n ^ downstream {CRecx Orel ~volbme Bared which ge~nerat6d AlaCk S1tlPkQ, of 7EG ~onzadar meter at LPC) A. DescNption b/ Nlsidet+t and Cause: (Cheek 88 aiarq~ ae needed to fulbr dssctlbe the lncidettq ' S!D TK.'u fGf ~,^ 1Process upset in , TIiC SD due b high a temperature section of fa~c~iQr _ Seal cN sy9lem dilruCtlltie6 ,^~ Fiarir~ !or drillsile stlukrdwn / startup ~~ t_NlFJtC~NCY SFIUTOOIIYN ~^ Flare syeDern tea-i~ ~- Ele~~lcal / kISCUmBYdabOfl It181tIMlCtIOR ~~, FaWltyr Sh1tldCYrrt on . Elacvical / klelrUmerrtetion melfuncdon ~- Fail mairdeneix:E t bi h f atdheriatlltgi (T&Dy a u~- er-toemPe arn Hig Gas trarreit system m '- ' S!D a1 high vbra6 F ~9 ---- ~ f~ 11 t~ttrer: ~ ~~im ~ t~ co ~a F~ ~ rates iMo taafnr fA~r -- e.llctlon Taksn ea Eli~inaEe Cause and Peavent liotrrrence: (Check and descrlhs as applicable) ~ Started / t~estarted TIC # Sh~ifized far.'ility process and aperalion ~"' ^ Cartlptessar / tr~ ddpr~essured ^, f R~aired equiMr>ant diffiwltie5 Radttoed /increased inlet gas rates "'~`~ Complo~ted flans testing ~ FaraGky maintenance corr>pleted ~' ~ ~ ~ ~~ Cwreliad E3J'IkrGttsadOn I fadlala - -- ~L. M1~1 M other: J1~P~E1~ N Conaetad Eel fllx~rtadOn -failure i+D SrbN6 aF [.e.~.~ait~ ~~ at other fA[dlity iT&D) ~ Bloc Smoke pid incident cause f~ladt smoke? Yes: ~ No: ~ {If Yes. continue with thins section) Did ktcidetlt preserd a potential threat to human basalt a safB17(? Yes: © No: ~ {M `des, report to FEC ae soon as possibia. ff rVO, report to ADEC trritlt 24 hours.) enter tag n Blade smoke emktetl frorrr source: ( umber' and desoriptiat) Nodded ADEC by Fit dl: Date: Tune: Report the ioNOtMirtB infarnrattars!/o ADEC vrttltin 24 hours ~Y ~7c (so7,Z69-7tM8): DaDB and time of beck smoke event Ffdtr: To: MSCF BBLS Yokane flared which 9 t~ladt smoke (if different from abot+e): ~„_ pescriptiort of steps to nrittrrirrli>:e emlesiats: Sat• Sacf7on t3. above. Type of materials txinraiK Gas: __ NGLs: ~~ Genets) Wr~lter: Air Temperature: Wilxl Spa~ll]iri~on' Warne and phttrte number d person m~drtg the t Name Phone ~ . RECEIVED Based on infcrl't1a<bn and befief fomled after reasonable atquiry,l oertiiy that the stai~rlerlts and irlfonrlation in and attr document are true. accurate and co ~ fate. • Facili~r supervfeor ` Dabs ~~~9D~60 NQU 2 ~~~'~~ Alaska Oil & Gas Cons. Commis+on Anchorage ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION (Facility ( ALPINE PROCESSING FACILITY Operator ( PHILLIPS ALASKA, INC. Field(s) I ALPINE Month/Yearof Disposition 11/00 Disposition Volume MCF* *Indicate contribution of each p ool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 ALPINE 100.00% 3. Flared or vented less than 1 hour 0 4. Flared or vented greater than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 473,199 5. Pilot and Purge 0 6. Used for lease operations Fuel Assist 0 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 473,199 8. NGL gas equivalent produced 0 9. Purchased gas 138,824 10. Transferred from: 0 ..................................................... C~{firaal Use:Or~l ==1=t~riti : AutforFzation > is tir::::::: 1. Safety MCF 2. Lease Use .~~ ~-{ "~ ~-'~, ~ r ! MCF 3. Conserv. Purposes MCF W~ ~f S ~" Commissi er Date 11. Transferred to: 0 Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. 5 ~, ~___ Signature: / ~~ "'""' Title: 5~ f~'~t~'~`- Date: ~ ~I Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ~~y` ~ ~Yr ~ ,,~~ `.J`~ cr~, y{,' ~-t<-~~e C' ~"' Form 10-4 (Revised 4/95) Gas Disposition Summary Colville River Field Gas Disposition Form 10-422 Incident Summary Page 2 JAN 0 2 ?001 Alaska Oil & Gas Cons. Co mmission Anchorage November Overview The Colville River Field sold oil into the sales pipeline for the first time on November 15. The oil train is the first module to be fully functional. Work continues on the gas train and preparations are in place to begin gas compression and re-injection. At this time gas injection is expected to commence before this report is published. Flaring continued throughout the month as efforts to commission the gas train are ongoing at report time. The low pressure (LP) compressor is online and fully operational. Until such time as the high pressure (HP) compressor is commissioned, the field will continue operating on Kuparuk fuel gas and flaring produced gas. Offtake rates are averaging approximately 40,000 BOPD while flaring approximately 38.0 MMSCFD. This rate has been maintained due to concerns over minimum gas loading rates and threshold pipeline operating temperatures. We expect the minimum load rates for the compressor to approach 40,000 MSCFD. Crude viscosity climbs exponentially at temperatures below the Pour Point (-5°F). At lower offtake rates the lower average pipeline temperature reduces the allowable recovery time required to restart the shipping pumps. Delays in startup of the LP compressor have been primarily associated with; • the Condensate booster pumps were commissioned on recycle, but the injection pumps had problems with their associated recycle valves. • the gas coolers required repair/replacement of the louver controller arms. • the BPCS was unable to control the start stop of the compressor motor despite the fact that this system had been operated previously. The LP compressor went on line November 26th, and testing continued through November 30th. This unit is now ready for fulltime service. Delays in startup of the HP compressor have been primarily associated with; • seal failures of the Greylock fittings on the interstage coolers. These high pressure pipe fittings require perfect alignment and had to be removed and refit. • the second stage dry gas seal housings had to be removed and new air flow holes bored in them to correct a manufacturing flaw. This work took three days to complete. • valve sequence problems with the blowdown valves. These problems were resolved December 1. • piping leaks during nitrogen pressure testing. • loss of the primary generator on December 1 due to a temperature probe failure. On December 2 the compressor was started for the first time. Another round of seal repairs consumed December 3rd. The compressor was spun December 4th to purge the piping of remnant trash . On December 5th the purge runs were completed, but do to Gas Disposition Summary Colville River Field Page 3 deteriorating weather conditions the decision to startup was deferred. On December 6, 2000 the compressor was brought on line in preparation to introduce gas and commence injection. A 2-4 day series of tests and mechanical checks are required before full time gas injection commences. Low levels of black smoke are being reported from the LP flare. The opacity ranges from 0-15°Io depending on operating conditions. The flare manufacturer is currently building replacement flare tips which are expected to remedy the problem. November saw completion of the producing well flowbacks (CD1-25). Attention turns now to flowing back the remaining WAG injection wells, which this month included wells CD1-31, CD1-26 and CD1-39. Due to weather and scheduling constraints the remaining six flowbacks will not be attempted until December. In accordance with 20 AAC 25.235(b), the following releases are included in Form 10- 422. Supplemental information explaining each event is provided below. The following are well events which exceeded the 1 hour limit, and are not included in the 10-422. Date & Time Event Summ Gas Volume 11/O1/00 Flowback and unload well CD1-25. All fluids are 273 MSCF 09:45 to 19:00 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks Burin the o eration. 11/03/00 Flowback and unload well CD1-31. AlI fluids are 295 MSCF 08:15 to 19:15 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks Burin the o eration. 11/OS/00 Flowback and unload well CD1-26. All fluids are 334 MSCF 09:00 to 16:00 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks Burin the o eration. 11/09/00 Flowback and unload well CD1-39. All fluids are 281 MSCF 08:30 to 13:30 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks Burin the o eration. Gas Disposition Summary Colville River Field The following Plant Events exceeded the 1 hour limit; Page 4 11/15/00 Initial startup and commissioning of the Alpine 5,595 MSCF 20:15 to 24:00 Facilit . 11/16/00 Initial startup of the Alpine Facility. Continue 37,110 00:00 to 24:00 commissionin activities. MSCF 11/17/00 Initial startup of the Alpine Facility. Adjusting controls 24,624 00:00 to 24:00 on the as train in re to commission. MSCF 11/18/00 Initial startup of the Alpine Facility. Gas train 26,658 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/19/00 Initial startup of the Alpine Facility. Gas train 30,834 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/20/00 Initial startup of the Alpine Facility. Gas train 32,547 00:00 to 24:00 commissioning is ongoing. Flare tip adjustments are MSCF and reported regarding progress. Black smoke was noted and re orted re ardin the LP flare. 11/21/00 Initial startup of the Alpine Facility. Gas train 32,868 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/22/00 Initial startup of the Alpine Facility. Gas train 29,121 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/23/00 Initial startup of the Alpine Facility. Gas train 31,048 00:00 to 24:00 commissioning is ongoing. Black smoke was noted in MSCF the LP flare. 11/24/00 Initial startup of the Alpine Facility. Gas train 31,904 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/25/00 Initial startup of the Alpine Facility. Gas train 35,651 00:00 to 24:00 commissioning is ongoing. LP knockout drums and fin MSCF fan coolers commissioned. Black smoke was noted and re orted re ardin the LP flare. 11/26/00 Initial startup of the Alpine Facility. Gas train 33,510 00:00 to 24:00 commissionin is on oin MSCF 11/27/00 Initial startup of the Alpine Facility. Gas train 32,868 00:00 to 24:00 commissioning is ongoing. Black smoke was noted in MSCF the LP flare. 11/28/00 Initial startup of the Alpine Facility. Gas train 29,870 00:00 to 24:00 commissioning is ongoing. Black smoke was noted in MSCF the LP flare. Gas Disposition Summary Colville River Field Page 5 11/29/00 Initial startup of the Alpine Facility. Gas train 34,260 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 11/30/00 Initial startup of the Alpine Facility. Gas train 24,731 00:00 to 24:00 commissioning is ongoing. Adjusting control systems MSCF prior to gas compressor startup. Black smoke was noted and re orted re ardin the LP flare. Total Volume Reported on 10-422 Line 4 473,199 MSCF it-02-00 08:32 From-ALPINE NSIRT + T-288 P.02/06 F-894 1 V/MMw.VA/ ~Y~~u~M~w ~r~~ FACNJ'fY: _ PSRMiTNO: ~;t~C~3:~~:::f~lC:r`~ pace of occw+eno.: I ~ a l oa O tiara J~ve~ ( d/yy) (ct,ecic Selection) TotadVaumeFksedv `L~MSCF 881.5 ~,;;. .~, D t Q Unpaaned (cr~eclc selee>;on) rus~me o„/~+- Gas salad was eom D Q aows~oam (c„err-c O„ev otTEG ca+lscbrayrewat tPGy Taft Ilanutss Flausd: = 5 v~ i Name and phone number d person matang the nepat Name Phone No. Tars of 0 Frorts •Y6 Ta t :o ~ 55 From: ~~, Ta = Frvrr: Ta = From: Toe Fran: T¢ _ Frail: _ To: s {inr ~~aitarle t9ared w/risa/l gerleraloacr i~dr smoke, XMpfasblel A. tJOSatpoioa of rKldeatand Caase: (Chock as r~g- ss nesdsd so furl describe the 6wFdanq SJQ T/Ctl ftr Pnooass ~~ m TJC 3D duo b high eoa~etm tomperahse serllon orfadigr -'^^~ Sae( ~ aystarn ~ Fk~ for dffllelM shutdown 1 at~atuP tS~RGENCY SHUTIaOV1Rt ~~ Fens sY~n 1a~ ~i l / t~suumarfason matCuncoon FauUy an ~~ l7acMieal / hstrurnen0a4on maltuncticn Fsaiity mainLellanoe atodrerfadihr Cam) ~' lii0h srrrbierrt~ C.,es traisit airslem oraipreswre SID on hqh vibretlon ~~ bewidn9 CPP1F1orr Stapon out ~!, ONIBr: V r C ' 2 I: BOBOeiva / i~SUlGtlOrlt Inlet ~ . ~- rates irdo faalily 1' ot~ _ ~,TAR't • ~ B. AcMOn TJakse tD tJrskrabe Calree and lax ttsprneilcs: (Glares aad describe ae sppNea6ie) ~ Started ! teaitarted T/C a* -..--- d Y and Ctxrlplassar / ![fin deprriesured R ~ t~9M diFflGt~ Reduaad / kraeased irdet Bas rates ~ ~ ~ ^`-' Faciky maitbenance oomplated other: S"fo 6U WHEN 'Tti~ tton/fa>ka+e fluc Carocoad }IOW W irL t Carrecied S&I ftuctuetiat / fdiltM9 . -. ~~ Q Y~tG N~ at dherfacd~r (Tdo) ~ Black Smol(a_ Did incident Cause btadc smctoo? YeS: Q N0: C1 (tf Yes, oordinrre with this sedicn) Q N Elul illCider>< pte6eM a potentkt! ifins~ to tlttntar+ heaNh a safety? Yes: ith 24 ltours ~ t]EC o: . w of Yes. report LO F~ as soon as poszA119. If Na, report to A eel' tag nurnt:er erttl dam) ` Nct~ied ADEC by aKF arc ~ Tarle: l2epoe: the ratloMrtng kdons.tlon >Q AaEC wkhln ?A Wows t3'Y FA.X tBtITT~6tlasos): gate and tine d bbidr smdae tr+ierd: From: To: AIISCF BB! S Yokano tittred which getrrersieol Dladc smaoe (d dKferent from above): Description d steps to min4trize emissions: See 9erdtoN t3. Above. Type of materials burned: Gas: NGls: _.,_._ Ottrer: Cet>Qr~ Weather. Air Ternpaatui+e: wind SpaetllDire~s: 13a5e0 ~ InTORn8U0n Sq WIICr r9riiwAU a1101 ~OCiDN.Pno w~yw ]~ ~ vq r~> w.v ..... ~.~.~...-..... __- _._ document ate boor aCCpr~e and oornpteUe- FactlitY Supervisor Oaf ~ EOC Supervoar, PRB 8 (flare gas and btadc smalae inidents) Field Envirautfer><al trarnplialCS 1'i001t~a>fr pRl3 7 tRiaGlc Smoke incidents only) PBUIGPMA Field Menapars, (Bktdt smoke Mciderds only) GPMA Oporadons Enpinoarirlg Tedmieat Aide, (GPMA repa#a only - ATO 4T/7 1CUpdndC field Ertvhorsnental t.otgrliatlCe Coordhmtori. NSK 61 (flare g85 end black amoioe k'~cidaMs) __- ---- _ .. - - -- -----~..- ~r~.~ _ _ .. FLARE GAS VENTING REPORT PHILLIPS A{~LyA~SKA, INC. • PRUDHOE BAY/GPMA/KUPARUK FACILITY: A~1:-:~-~:~:?~?~~~.:~'ME N~ PERMIT NO. ~!~'~:~::•`•:~:C;:QC~:~?;: GAS DISPOSITION Date of Occurrence: I ( ~ ~ ~ b ^ Flare ~ verrt Time of Occurrence: (mml d/yy) (Check Selection) 00:00 24:00 Minutes From: `.15 To: 6`t`.l$ = i:(;0 Total Volume Flared:. 2`i _S MSCF BBLS Fnxn: To: _ From: To: _ Metet~lNo..:~:~:~:~:~:~:<~:-:~:~:~:~:~:~ ' ~Faci ~':~:~:~:~:~:~ ^ Planned ^ unplanned From: To: _ (Check Selection) From: To: _ From: To: _ Total Minutes Flared: = b13~ (Lisburne Only -Gas flared was from ^ upstream ^ downstream (Check one) (Includes volume flared which generated b~clt smoke, of TEG contactor meter at LPC) if applwcableJ A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) S/D T/C# for Process upset in TIC SD due to high exhaust temperature sersion of facility Seal oil system difficulties Flaring for drillsite shutdown !startup EMERGENCY SHUTDOWN Flare system testing Electrical ! kstrumentation malfunction Faulty shutdown on Eledric:al /Instrumentation malfunc~on Facility maintenances at other faality (T&D) High ambient temperatures. Gas transit system overpressure S/D on hgh vibration bac9cing CPF/Flow Station out _~ Other: -app cIP ) W (~ Excessive /insufficient inlet gas C)i'- C ~1- 31 It~1 , 'PRk P ~tl rates inm facility START t.t ~ B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe ~ applicable) Started /restarted T/C # Stabilized fadlity process and operation Compressor /train depressured Repaired equipment difficulties Reduced / incr~sed inlet gas rates with Completed flare testing Facility maintenance completed Corrected E&! fluctuation /failure _~ other: 5"Tr,QP~~ WNE-~ THir w~t_t Corrected E&I fluctuation /failure .S,,t-lO W t: 0 S. C-rN S t1F ~.-~~NZI at other facility (T8,D) Ll P ~ j ~/c ~*l C~ Black Smoke Did incident cause black smoke? Yes: ^ No: ~ (N Yes, continue with the section) Did incident present a potential threat to human health or safety? Yes: ^ No: ^ (ff Yes, report to FEC ~ soon as possible. ff ivo, report to ADEC with 24 hours.) Black smoke emitted from source: (enter tag number and description) Notified ADEC by Faxon: Date: Time: Report the following information to ADEC wi~rin 24 hours BY FAX (907-268-7508): Date and time of black smoke event: From: To: Voume flared which generated blade smoke (if different from above): MSCF BBLS Description of steps to minim¢e emissimrs: See Section B, above. Type of materials burned: Gas: NGLs: Other: General Wither: Air Temperature: Wind SpeedlDiredion: Name and phone number of person making the report: Name Phone No. Based on information and belief formed aft reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurate and <brn e Facility Supervisor ~ Date ~~ ~~ fl~ cc: EOC Superv~or, PRB 6 ( gas and blade smoke incidents) Field Environmental Com ce Coordin~ors, PRB 7 (Blade Smoke incidents ony) PBU/GPMA Field Managers, (B~dc smoke incidents only) GPMA Operations Engineering Technical Aide, (GPMA reports ony - ATO 47'1) Kuparuk: Field Environmental Compliance Coordinators, NSK 61 (flare gas and bl~k smoke incidents) V Cr FLARE GAS VENTING REPORT PHILLIPS ALASKA, INC. • PRUDHOE BAYIGPMAIKUPARUK FACILITY: ,~~~:J:~::~::::~~~1`.~~.~1Z1~~ . PERMIT NO. :::~::~;:;:~:: GAS DISPOSITION ` ~ ~ ~ ~ ^ Rare ^ Vent Date of Occurrence: ~ ~ Time of Occurrence: , (mm dlyy) (Check Selection) 00:00 24:00 Minuies From: ~ ~ ~ ~ To: ~(6 : d G = Z U Total Volume Flared: a ~~ MSCF BBLS From: To: _ From: To: _ MetiBr~N'o.:~:-:~:~:-::;:;:;:~:;:~:-:;:;: ~•~F~ci ^ Planned ^ unplanned From: To: _ (Check Selection) From: To: _ From: To: _ Total Minutes Flared: = l'~' Z V' (Lisburne Onty -Gas flan3d was from ^ upstream ^ downstream (Check One) (Includes volume flared which ge-1erated bi9ck Smoke, of TFG contactor meter at LPC) if appicable) A. Description of Incident and Cause: (Check as many as needed to fu8y describe tim incident) SID T~Ak for T/C SD due to high exhaust temperature Seal oil system difficulties EMERGENCY SHUTDOWN FJectrical / krsUumenta6on malfunction Electrical / krslrumentaficn malfunction at other facility (T8D) Gas transk sysUsm overpressure baddng CPF/Flow Sfati~ out ~_ Excessive /insufficient inlet gas rates irrta fadlity B. Action Taken to Eliminate Cause and Prevent Recrurence: (Cheek and describe as applicable) Started /restarted T/C # Compressor /train depressured Reduced !increased inlet gas rates Completed flare testing Corrected E81 fluctuation /failure _~ Corrected E81 fluctuation /failure at other facility R&D) mdse inddents only) PBLUGPMA Field Managers, (Blade smoke incidents only) GPMA Operations Engir>eering Technical Aide, (GPMA reports ony - ATO 477) Kuparuk: Field Environmental Compliance Coordinators, NSK 61 (flare gas and black smoke inddents) Did incident cause black smoke? Yes: ^ No: ~ (If Yes, continue with this section) Did incident Present a potential threat to human health or safety? Yes: ^ No: ^ (If Yes, report to FEC ~ soon as possible. ff Pb, report to ADEC with 24 hours.) Black smoke emitted from source: (enter tag number and description) Notified ADEC try Faxon: Date: Trtrle: Report the following information to ADEC vrithin 24 hours BY FAX (907-269 7508): Dane and time of blade smoke event: From: To: Vdume flared which generated blade smoke (if different from above): MSCF BBLS Description ct steps to minimize emissions: See Section B, above. Type of materiels burned: Gas: NGLs: Ofh~: General Weather. Air Temperature: Wind SpeedlQirectiorf: Name and phone number of person maldrtg the report: Name Phone No. Based on mrormauon ana w~~~ ~ document are true, axurelte and Facility Supervisor Process upset in section offaality Flaring for driilsite shutdown I startup Flare system testing Faulty shutdown on Faciliiy maintsnance High ambient temperatures. S/D on high vibration Other: ~dt+i~0(~~ /Ct,tr.HN t9f ~l-~1.~t.1I Stabilized facilih- process and operation Repaired equipment difficulties.... with Facility maintenance completed Ottrer: ~'G4 ~-~ A~t~~1F ~,~1hILl._ ~1~~~.1~~~ ~:~.yn3~ C~"c. e:.glv`UVt LJe ~ L `~ / ~ tr,1 ~. Dare ~ ' ~ cx: EOC Supervisor, PRB 6 (flare's and blade smoke inddents) Field Environmentnt Compf Coordinators, PRB 7 (Black S to this 11-14-00 06:59 FronrALPINE NS)11' + T-844 P.02/02 F-604 ~SKA, INC. • pR1,IDHOE 8AY/GPI anclrrl~r: :~f~i~.~_,...,;pl~Et~fi- P~ultT trlo~. oa~a of oecunonorw + t a9 QQ Q Flare ~ vent (N!-) {c~ieclc selection) Total Volwne Flatsd: ~g( Nl9CF et31.s ~~, ~ Plarnee D unpanr~ed (Check Selection) {l.islwnre ~-Gas rtaroe was Gam © ^ doYaes~, (chea+r or+el of 7FG coarer~or~rrefaratl.PC) I T~ mom ~ ~. 1 Franc ~ Ta 13:30 = 3dt3 Fran Ta FronK i- ,,,~,~,~_ Ta ~- Fraa: Ta From: Ta = Flan: Tx Total flfinrlee F~ajad` ~ ~d i (Anakdbs yellers ~irgd w/pch Qer,erek9d blhok srrroke, 8) A. Oeacri>~rion of Inaldwu rrrrd Cause: (Check as rrwrr~ as Healed >4 ftr~- deacr~s tits incident) SA) TICe for ~~ rl~ so dus to hlgFr e~draust Mmperah~ra Ses1 oil sysum ditllcultles ewI~RCEtrcir SHU7UOwN i7eclried ~ Mrstumenlabon melRarciian ~~ FJSdneef / krstunrantatian maifixrcoan atolFR+rieo'~ity (TSD) Gas traait weitx®ar++B ^i- CPFlFIow Station out F~ooeesiva ~ insulr~cient inlet ps: cares into taciidy e Actton Taksn to E6rnirla,sa Cauca and Prvyart RaCVntirroar (Check and deecrlbs ss appNcabls) Staged /restarted T1C l1t ContPrasser /hen deprsaeutetl RerMloed / ktcroasad Inlet gas rates -- Completed flare te6ting Cotreclstl Eai itruduatiarr ~ fairxa '7C1 Ccrrocbd F31 tlucarattott / fa~ttre at grhsr faer'ity (T8D) ProCeeR upset ~ arxiorr of taa7igr foraratsss ehi,ltlown ~ startup Flora ayalr~n teaina Fauigr etwldona- on . Faddgr melrNerrer~ee~ Mlph ampientievnparaV<iea. ~ S 1 on high ~Nxaticn Other: U~1 .!7 w OF G t- i r S~P_;r__l.~o_ t~fabiBaOd idcNiq/ Process and operatior- Repaired aquipmart dHflwlhas vYltr FaCih~y ma~lenarx~e conlpleled c~arrx: SroP uJ'.1~1U ~~tl- S sl S ~ riW ~ `] ~n fn}ra .. p~ ateklsnt cause btadr snwlce? Yes: ^ No: ~ {If Yes, ctirtdrNie with thia sectkxtl~ pid lrrcidertt prsserrt a t threat to hum hear<tt or sefdly7 Yes: Q No: d (1} Yom, napott>n FEC as Goat as tiaaalNte. tf No, report m ADEC wltlt 2+l hotrca.) ~ Blaac smoke entrtted from sorrrcac {enter tag ntirrrbe~r and description? Notified ADEC by Fax ort: l7atg Tana ' Report t~ following irAonrratlorr to AP~C wa>tin 24 hours @~~ (807-289.7608): papa and tints of bk~ok emotes everrb FnDnx Ta VolWne flared vrhich ganerate~d btaclt smdos (d dilferert irons above): AA.SCF ~ BBt.S pesexipdon of stapu to min"ar+ize andssiona: yes 8aatiai B, above. I Type of rnatefiAis blurred: GAS: PIGIs: ~~ Other: Ggnaral weather: air remPaatura wind SpeedfDirectior>: Name and pttOrle n+anbar of Person making u,e reporti NartMS ~ Phone No. t3,~ed on Jrtfamtatiort and belief fonrted sfper reasonahta tngttiry, I certify that ills smterr~tts acid infoanatim in and attadtea oo this document aro irti9, searara and axr~ ~~i: „ FacWhr 5upsrvisor ~ p ~~ py~ 1 l OQ ea E . PRB 6 (flats gas and blade smoke inadartls) Field ~nvirorrrrerrtal CarrpNarrca Caorsl6lator'8, PR8 7 (t3laek Snrdre ineidanta ard~ PBtIIGPMA Field M9riagtxs. (9ttlek smote trleidarNs onlyr) GPMA OparadOr<s ~n9ineaein9 Technical Aida, (GPMA reports ony - AT+O 4TH f Wrpanalt Field Enviratnrentai C,arnpGancs Coadmalore, f•!SK $1(tlsrs tree and black snrafrs incidarrts) i1-27-00 18:22 From-ALPINE NSNT + T-326 P.02/12 F-282 !:CARE GAS VENT1NC;t 1iEPQRT PHIWPS ALASKA. INC. • ALPINElKUPARUK FApIJtY: Alpine UevelOpment Pro19ef PERMR No. 0073-ACGa9 GAS DlSP_QSITION fJatsofOeeurrettoe: ~-/S-O~ G7fiare ClYcnt TI of Occurrences (mnvddyy} (cheat Selection) p2~0 2~ Wtimre From: ~%S To: vo 2ZS Total Volume Flareek ,~22.(~ MSCF 8f3LS From: To; _ Front. To: NkterNO'~ - ~•~ B Feed ~ ^unppmeo From: To: (Check SelecGOn} Front: To: _ From: To: Total MietrOes Flarerx = ~~.~ (usoume Qny • Gas !fared was /rt7rrr ^ up~m D aamsveem (C7~ack oute- (lndudes atzlrulre ffa-ed wltidt perleratad Wads srrroka, otTEC3 oarrrachorrrrararaltPC) it dRDiiC~ls) ~ A. Dos+crlptbn of Irtetdent end Cause: (txteck as many as needed ib fully tleet:tiba the ittclclane) 31D T/Cs for Prvtses upset in TIC SD due to nlgh e~otattst temperature Saotion of laaey Seal oa system altbra,ldar; ~„_ Flaring for dr~ite ertuoaowrt /startup EMERC3EMG"Y SHUTDOWN flare system testing BsCtrSea1 / insavmenffinon maltundlon Faulty Shutdown on Eieruical / (f16MerrafiffifiDrl maaunGGiOA FaoiGtY rt181raer1ar108 at other fatality (T3A) f119h arnbfeertt ttxnpaattrres. ; Gas transit system averpreaeure S7D ort high vitiation baradrfg CPF1FIdr Sffitlort out ~ t]ther_ .TNYI'rRC~ s/tt dF diva/in6ufrxaerltinletgas f)iL~rIN~_ ~A@/t/T3~ ~j~,~5~ rates irtce faarsy B. Action Talasn to Ei'irrNrtate Cause and Prevent Recurterxae (Check and describe as aipplloablo) Started / reStartatl 7/C # SfabiUzatl taCUEty proeress drtd operation Compressor /vain depressured Repaired aquipmem diificutties Redrroed / tncxeasetl Inlet gas rates with Completed flare testing Facility malntertance completed Corrected lii&I ftucwation / faAure ~_ C+tlter. ~AS_ ~i AGV .5lL[ Corrected Ebl flurtirtation / faaure ¢ C~avr.-trSSiratte d~v Gor..w at other faalily (T&D) Black Smoke Did incident cause black smoke? Yes: ^ No: fd (If Yes, continue with this section} Did inctdertt present a potential Cheat t4 human hearth Or Safety? Yes: t7 No: jd ; Rf Yes, rapoR to FEC as soon as possible. B No, report t'o ADEC with ?.4 hours) t3laelt smoke emitrer• *nm sarroa: ,(emer tag number and description} Noticed AOEC byT-...>;.. .idte: Tme: Report the follewireg inlornradon to ADEC Within 24 hOtIrSBY FAX (907.289~760~: Date and tlme of bleat smoke avant: From: 70: Volume cared which generated bleat smoke (it different from above): MSCF ael.s Description of steps b minimize emisslorts: See Section B, above. Type of matefiels burned: Gas: NGLs: OCter: ~ General Weather. Air Tamperaclre: Wind SpeedlDirection: i Name and phone number of person making the report: ~' Name Phone No. Based on Information and belief formed after reasonable inquiry, I certify that the statements and iniamiettion in and attached m this document are true. accurate and//~j plate. Facility Supervisor ~'y`~' ~ ~ Date / / J 0 i up0aterk Fl3C RrOe R1Group•\MStTiEnvkorvrter>rer Helplfvrtra~-0014618.>as 11-2T-00 18:22 From-ALPINE NSfr<f + T-325 P.03/12 F-282 FLARE GAS VRNTING REPbRT case of Octunenca: Total Volume Flared: FAGitJJY: Alpine Development Prbj9Ct PERMR NO. (mm/adJyy) (Cpeak Selectbn) ~MSCF BBLS ~PfanneA ©unparnm (Check Setaouon) (L7sbume AMy - Qss !Jared was rrorlt D upstream p down~am (Chock t7tx) o! TEG cor~tor•motarat l~ 0073-A0009 , Time of tJcurrrerree'• ~ 24~~ From: pt7ro0 To: :op = X{yam From: To. a From: To: : From: To: - From: To: From: To: TOW MiInYlOa Flarod: s ~ qr ~0 (lrrck~des vokrnre flared which generated bJadr SrJrOka it appfiiCdb/9/ A. C!oserfptfon of Incldertr and Cataa: (Cheek as many es neodod to npry descrtbe ltts Ineidnrtt) SIC T14.a far TIC SD due q i:lgh exhaust lantperature seal oa system ~a,nia -~-^ f~1AERGFJdCY SHUTDOWN l3eeMCal / lnstrumenlation malfunction t~etsi®1 J InsbtartsntaGOn maHunCtiOn -^ at other fadfie- (Tt'.D) Gas eanatt system overpressure lutam:g CPF/Flow Station out ~ F,toBeBlre J irputfiaern iaet gas . tales into tadfuy B. Actloq Taloae to Eltmletale Cave and Prevent Recurtertce: (Check and describe as appaCabM) Started / restarted TJC a Compressor / train depressured -~ Reduced /increased inlet gas rotas Completed flare tesAng Corrected EB~I fluc'tuatlon /failure ~` Corrected FJ91 fluebratlon /(allure ai other fsality tT~D) Proases up~etin saetlon of taeuay Flaring for tlfilsit9 shutdown J efarlup Flare system testing Faulty ststdosvrl on FaraGty meirrlmtars:a , ltlgh amoiartt tanfperawres. 3!D on high vibraaion other: .7'a~no~ ~1 F aea~rW a~iccs, - '`- -~....,. 9tabillzed fadlity process and operation Repaired equipment di(Boulge8 wild Fadiky maintenance completed t7tller: S~~fA ~ o r o~ I~[ QF C~(/RS~ TieR1,U 'ON CJN Dld ktcident cause blast smoke? Yes: Q No: ~ (If Yes, continue with this section) Did incident present a polemist threat tD human health or safety? Yes; D No: ,~ (If Yea. report to FEC as soon sa possible. tf flo, report to ADEC vvhh 24 hours.) Btadc smoke emitted from tlource: (eater tag number and description) Notified ADEC by Faxon: Date; Time; Report tlla fdlowing Irr/armetlon t0 ADEC vrtehin 24 hoursBY FAX (8pT•266•y50g): Date and time of black smoke event: From: To: Volume flared whist generated black smoke (tf different from above): MSGF 89GS Description Of steps to minimize emissions: See Seetlort B, above. Type of matertals burned: Gas: NGI.s: otl'ter: General Wsattt®r. Air Temperature: wind SpeedlDlreetlon: Name and phone number of persnrt making the rt:port•. Nettle Phone No. Based on irtfomtation and belief formed after reasonable inquiry, l certify that the statements and inbrmatiort in and document are true. aorxrrate arts complete. Facility Supervisor ~ ~. Qate /! C) '~1pO~B~ tn~ eroo P.1raoups~rrSE7~rxrylrortrnernd t~elp~ronm\F~ore Gas V anwp ram ~-pb+s 1 I~toaes 11-27-00 18:23 From-ALPINE NS~11' + T-3Z5 P.04/12 F-Z8Z FLARE GAS VENTING REPORY Date of Occurrence: FACLLfiY: AlpinA U9v®lopm911t P1oi~ PERMfr NO. was otsPOSmoN (mrrVddyy) (Check Selection) Total Volume Flarptl: ~/7fA9SG~' MSCF 681S RAelerNo:~ 1• ' B Fec ~kvnea ^Unpracned (cnecx selectia,> From: Flom: From: From: From: From: 0073•AC~09 Torre of ocaurcermea f Z. r To: ~ _ ~.~- Ta - To: ~ - Toad Afkrutea t=leled: _ ~i-..S (f~sneme orry .Gas flared was trorn OupsOam ^ mwnaomnc I ono, of 7t-G cortfacxarmeteratf.PC) (frlcyudas vwwne tfaree NdtfrJt generated wear smo% Kappffaadre) A. Da3~riptlon of IncldaM antl Cauax (t:haok as many as needed to tulty tlasecl6e the irlCltlent) SID T/Ci, for TIC SQ due b high exhaust ternparature Ssal OU sys0am diffcuttia5 ~~ ~_ ~_ EM<~IGENCY SNtlTpOWN Electrical / Irrstnmcerrtadon mafturxxion F3BC1dCal / lrrstfumerrtation malturxm~tion at dhst faNtlty (Td,O) C4as transit system overpresecae txiddng c:pPrFiow Bleach out _~!s_ Excessive I Irrwffxient inlet gas nitss inm tatslity Process upset k1 9eCC>j•011 of fadTdy ~9 ~ tlrdioiie shutdown farhip Flare system testing Fauty ertualowrt on FaaGgr mairuenanpe regh ambkrit temperstwes. SJD on high vi ration other: ,~ ~.. S~~ c~F ~ ~_ ~~ pe~~~sj 9. AdiOrr Taken to Etimfrage Cause antl Provent Reaurrarrce: (Chet:ic and dasaibe as appOcabie) Bladed /restarted T/C e Compressor I train depressured Reduced /increased inlet gas rates Gornpiated flare tasting Corrected Edd fluctuation / faiure ~ Cotrecoad Ed,t fluctuation /failure at other iattiliry (TAD) Stabt~ed Y process and operation Rapnlred egtripmem difflcuiges wqn F~~Y ma~enarxse completed Other. u~ 'u s 7~, i-n (sir fro P r-i~er fn __ ~S. ii1 _ G[r~"ii~. _ .SIN ~1+r0 Did irtcidertt cause black smoke? Yes: ^ No: ~ (If Yes. trortflnua with this sectlon) Did incidem present a potential threat m human health or safety? Yes: D No: ^ (If Yes, report to FEC as soar as possible. ff No, report to ADEC with 24 hours.) 81adc smoke emitted from source: (enter tag number and description) Notifletl ADEC by Fax an: hats: Tom; Report the folktwing irrfomtaatxn m ADEC within 24 hour88Y PAX (9Q7.2B~7608y: Date and time of Mack smoke event: From: To: Volume flared which generated black smoke (If different from above): MSCF Eg~S Aesuiption of steps to minimize emissions: Sep Sectltm B, above. Type of materials bulled: Gas: NGLs: Other: ~ Genera! Weather. Air Temperature: V1wnd radian: ~ ~ ~. Name and phone number of person making the report: J~~/Il ~.t~j~.l.<,$ ~7d r Name Phone No. t3ased on information and belief loaned after reasonable inquiry, L certlfy that the document are we. acxurate and oa lets. Faclltty Supervisor and intormation in and attached W this pate 1/ V U Uptlatark FECa/oD P.\6ra~ps~ti36r1Enraenfr~enrd Harp\Fome~-0014418.nr 11-27-00 18:23 mate of Octuer+ertee: Total volume Flared: >~~n1°0 ^ Unolenrl0a (Check Selection) T-325 P.05/12 F-282 OC73-ACfl09 Tune et Otxurt+enoe~ 1n~ 24.9Q td~ From: ~aC? To: .fi:o~ From: To: - From: To: - From: To: Fiortt: To: - From: To: - Toed Minuses Flsrerk ..f..L~ lLJst#!me Grrb • Gas eared woe /ran O upstream ~ mwrnneam fG~aac fie) of TEG c0rttaCfcrnretaret iPCJ (fnCfudes vokatl8 lls7rtdd w1liQR generated bdacfr smolca, !t appla~bfe) A. Doscripllon of Inclderrt and Causos (Cftedt as marry as needed to Puny describe fire irttltlont) 3/0 T/Ca tar Proaesa upsatin T>C 1D due io tuph e>Q-sust temperature ~ section of faoUitf/ ^~- - seal oM system dirieuttiss ~_ faaflrg for tlrtsalte shutbwn ~ startup EMt7tGENCY SHUTDQVJN Fyre aye g E]ecpical l Inatnanernation matttrrtcdon Faulty etartdoertt on t7sctrkal ~ Instrumentason malhufetion F~igl mainolYfarrc~e at other faolitfr (TdD) -~ aunt ~, Cas trarreit syssm overyressure 3/D on high vi4tation baddrg CPF/Fbw station out ~~ Other. ~7'/I¢L S' ~( p~C t::ooessive I insufficient inlet gas L P/~t! c /~.~ races aaQ facdihr v1E . 8. pgien Tekan to Eihnirteito Cause and Ptetretrt tiaettrronee: (ChecK afro dascMbe as applieagie} ~~ / ~~ T~ ft Stabilized facility proesass acid opere~tion Compressor /train depressured Repaired equipment cZlficulges Reduced /increased Mlet gas rates avitlt Completed flare testing Facility rrtsitttenartce completed Corrected f$i fluctuation /failure ~_ Other: /rs-AS ~~A/,t./ S/(,~ tSorcectedEBdfltreCratbn/failure 1+t' ~mlrlnf~59~ot1» at other facility (la0) d N Aoi.~ _ Did Meident cause black ttttloke't Yes: ~ Nv: (K Yes. aontlnue with this section) Qid incident present a potential threat to human heahh or safety? Yes; O No: (tf Yes, report m FEG ds soon ss possible. fl No, report to AbEC with 24 hours.) Stack smoke emitted from eatnre: L-vWPrre ~(~r~ GF~ ' ~ (errtartag number ar~d desciption) Nomad AE~SG ny Faxon: Dare: Z~ Time: U 7 35 YjY emc.~ t ~ Report the fWlowin9 information to ADEC within 24 houraBY FAX 9t?7,2B9~75oB): Qals and time of black smoke event From: ~ To: 2 ~ QO ; Volume flared which generated blade smoke (if different from above): MSCF BBI.S Description of steps to minimize emissions: See Section S, adpve. Type of materiiats homed: Caas: ~_w~NGLs: Other. General Weather. AlrTemperae,re: "roc ~ wndSpeedlDirection: i(J~ /n ~' n~,(~ i Name an4 phone number of person making the report: ~ Y-~, r., ~ ran ~ Din r-t-~ i i / Rt7'7 ~ l0 7(~ ` +{ ~OC7 Noma ~ Phone No. 6asetl on infomtativn entl beuet•tortt-ed alter reasonable Inquiry, tcertiy that the statements tutiditefortr-atbn in and attached >d document are true, aoarrate an`d~~co~mp~l~etey. ,, / Facility Supervisor _~~ `/ V ta[~ beta /~~/y~ ~ From-ALPINE NS~IT FLARE GAS VENTING REPORT FACttmr Arne Development Project PEtsuirt N0. //- /$' 40 ~PRnre i3venc (mmfddlyy) (Check Selection) e~ ADO MSCF 681..5 11-2T-00 18:24 Froa-ALPINE NSirlT + T-826 P.08/12 F-28Z FLARE GAS VENTiNti REPORT Pate of OeWmertrx: FwCw1Y; Alpine Development Project FERMii Na. (rtrtt/dd/yy) (Check Seleohon) Total Volume Flared: o2~Op r~nsGF !0 6t31.S Meter •P• feat~noa ~tJnvlanca (Check Selection) !+-+sbume oMy - Gas !l<vroo was ttom t7 upar~o U do-,w7cu®m tcnvaa or~~ of 7th carrlaClbrnteterat[PC) 0073-A0009 Ili! Qf Oceurteitee=_ , l~Li1Q ~ ~ l From: ,~p_4D To: ~_ _ _ _ /4!~K4 Front To. From: To: - From: To: From: To: - From: To: Tom Minute. Elated: - (lnraludes vnNune flared whirri generated efadc aretaka. n~ppff~aae~ A Description oe Inciderd and Cause; (Cheer as many as noodod to fatty eeserihe the irrCidertt) SJD T/C# for Process upset in TIC 80 due a high oraraust temperawre sectloe of faauty sear on system annwlnss ,~,_ Haring for drillrire stwtaown I startup EI~A193GENCY SHtJTDOYYN Rare ayolem testing Etec~icar / I-repunrsrpedm malfurxtlort Faulty shutdeonm on tBeCtriCai / Irtstrurrrerrtatlon manunction Facility mainter-arrce ' ~ °~ ~8Y (TaD) High anrbisrri temparaturos. Gee transit system overpressure S/b on high vibration batldrg CPF/Flow Station out ~ Oilier: Q NlT1A~ .S~G[ d F' _ E>omssive / insuffident inlet gas ~/Al R d/C I ra1Be into facility ~k'icts ~ ri_ B. Aedon Taken to £IlrnlrtRe^ Ceuw ^rtd Peevent R^currenpa: (Check and de6Ctip0 as epplieaAlo) Started !restarted T/C # Stabilized fadlity process and operation Compressor /train depressurad fiepaired equipment drifxarltles Reduced /increased Inlet gds rates with Cortrpleted flare testing Facility maintenance completed Corrected E&I fluctuation / tauure ~ Other. SrLC ~ ~.rw~txs/cw~.,, _ Corrected E8J flucnratlon / faUure ~ dL f~~ Ri,r[ OK9d~k3 . at Omer facinty (t'aD) Black Smoke Did incident cause blddc smoke? Yes: ~ No: ~ (1! Yes, continue vMith this section) Did lr>cident presem a potential threat to human heaittt or safety? Yes: ^ No: (If Yes, repoK to FEC as soon as ibis. tf No, report to ADEC vWth 24 hours.) Slack smoke emitted horn souroe: ~ (AY ~, ~. -- ~ (ententes number and descriptioM i r"7 ~ ~-+G Notified ADEC by Fax an: Date: tap Time: [~'~ ~ ~{~> -r7~; { Repot th^ iorlowing ir-romtatton to ADEC wlmin z4 hoursBY FAX (~-zs~~soe): Date and time of black smoke eNant: From: CCU : O d To: ~ ~ ; p (' volume flared which generated black smoke (rf different from above): ~. MSCF 68L3 Description of steps to rruMmlze emissions: See Section e, above. Type of materials burned: Gas: ~ NGLs: Other. General Weather. AlrTemperature: l~ Wind Speed/Direction: / }3 f Name and pt-one number of parson making the report_:~ri~r-7r~o,~ l~jP-•~,7~ / /~ ~ ~d7- ~7d ~~f?rip Name Phone No. rsasea on mtormauon ono oeiret tortned attar reasonable documem are true. aoarrate and r~mplete. , n Faeitity Superolsor statements Date / / d m ~s~ FtC 6ro0 P:16rwpslHSET1f7nA~orun^rNd rterPlr`om'q\-0014o18aos 11-27-00 18:24 From-ALPINE NSI~T + T-3Z5 P.07/12 F-282 FLARE GAS VENTING REPORT pate of t~odmertca Total Yoitrurte Flansd: FACI!lIY: Alpine pevelopment Project PERMIT NO. (Mntldd/yy) (Check Selection) ~Q4~ M3CF s81.5 Meier ~ ~ Fecit J"P ~ungsnxe `1~ ~''!~ 3So// (Check Selection) (List7ume Only -Gas Ratles0 was hom A upstresm O downstreom (Ghocrt ors) cf TEG cartraaormeterat t.r'Cj OOT3-ACOQ9 ~Qf_Oeeurrene:e: QLLflO 24.'DQ ; M From: To: ~ = ytfp ~ Krorn: To: ~ ' '- Frtxrt: To: -" 3 ~: To: From: To: ~'~ Fronk To: ~` e - Total Mbartes Flared: (lAdtplm6 vokrttt9 rfdreQ which generated b/adcsrnpdbs, if aP1e) A. Description of IriCldertt ants; Csuae: (Cheek ae many as rteoded to rally deacrlDe the inWdet~ SID TIC/ for Process up6etin TlIC SD clue to high exhaust temperatine section of facility seat oU system dhtlculdes ~~ Prating for drutsite shutdown! startup (3M139GBdCY SHUTDOWN Flare system teetfng IEearicul ! Instrurrterttation matlunction FauRy stttadown on F3eCti'iCai / Instrt,rrtentalltxt rnaHunctlon FaCYny meirtterrarroa ai ottw taairdY (TBDj High ambient temperatures. '~ transit system ~@ SID on hi h w'bratiort tmgckig CPFlFlow Bretton out Other. ,V .44 ,$ k OIe ~ _ 6oo~ive I insulficieM inlet gas A+Lf'/ - C/LIT' rates irno facility ~ A. Attlon Tak~t m t2Jimineea Cause and Prevent Recurertoai (Check and dest716e as applicable) . Started / restaged T/C ~ Stabilized fadlity Pis and oparatton Compressor / train dapreaeured Repaired equipment ditnCUitias Reduced /increased inlet gas rates with ~ Completed flare twang Faaiity maintenance com ~ Corrected F-&t fluctuaton / tailors ~_ Otfter: !~ a .~~~ Corrected E81 fluctuation / fat~ure D~' ik • A N at outer taciliry (C&D) ~~-~f~ µ Q~~ l3taGc Smoke Dtd (ncldent cause black smoke? Yes: ~ No: ~: (If Yes, contlnue with this section) Did incident present a potenitat threat m human health or safety? Yes: © No: {tf Yes, report to FEC as soon t;s possible. If fio, report to ADEC with 24 hours.) Black stroke emitted from source: _~ f LI'fil~~ rJAS (enter tag number and description) • Notified ADEC by Faxon: ba~a:~-~,,(~f~t~ Tirne: rj'7~~j5 }'nj-~-ju~>vr'r"IC~i Report the tollowMtg frdomtatiart m ADEC within 24 hotxsey,~ (907.269.7508k Date and time of bladt smoke ew:rtt From: ~t/ia,4~ rZ:• t+s.w To: /l~Zt~•• /~:'aaw Votuma flared which generated block smoke (it dttferent iron above): MSCF BBLS DescAption of steps to minimize emissions: See Section 8, above. Type of materials homed: Gas: ~ NCals: Other. Genera! Weather. Air Temperature: ~~~ Wind Speed/Direetlon: S ~! 1'l0 Name and phone number of person making the reporC~~,~ n ,-~ n ~., [~ o,-, r -^~ ,~? J /~ ~ Name Phone No. based on information and beNef tormsd Biter reasonable irpuiry, I Certify document are true. axurate and complete/. Faellity Supervisor ~ I,j Date /~ fiI 0 d to u F~c ttrop ~:~~,~.~r~sltlt~ r~a¢~Foar,s~-awoota.w~ 11-27-00 18:25 Prom-ALPINE NSI~i' + T-3Z5 P.08/12 P-Z8Z FLARE GAS VENTING REPORT FACtLdTY: ' *Atptrse E7eivaltighAalPt Pi+ii tut ~: PERMT NO. ~G?~AQ~`'...... Date of tacwnertco: !/ ~ / ~- Q ~ D flare Q~vex (mmrddhy) (Check Selectior-) Total Volume Flarod: ,~D. 7MMSCF BBLS Allelt9l: ~r7~ .e' '1 ~aci •~:''. I~r+anaa ^4s+pra~ned (Check Selection) (IJSbtmre t7nIY- Gas fisted ass them D etauasm ©aom (cteew east or7>=iC eontadormeteraetPC1 a Dasa~ipgan of Indeent and Cause: (Check as many ae needed to iuly dees~e the tnctdenr- SID TJCrF for T!C SO due b ftigh exhaust temperature Seal oN ayetort-dtC:wltiec EMERGENt:Y SHUTDOWN Electrical / Irmtnrmemafien matNrtctlort FJecYical/lnepuntartte4on matmndiort atoatertadtlgr (T8D) Gas trartsa system ovorpteae~se uadta,e CPr~Ftow statten art EoteeBeNeB / ltteurltcient irtlat gas tales Into B. Atdlen Taken b Elltrtirta4l Cause and Prawrtt Recurrapce: tCttsclt and describe as appNCabls) Startttd / festaRed TIC # Compressor /train depresstred Reduced / increased inlet gas rates Completed ffaro testhg Corrected Edd fluctuation / faiiure COt7~ted F~1 fluduation ! failure ~- at ether taalfly (TB~D) Fran: T1me of Oectereef~! `r`i' Ta. ' Q = 'i O Frarrt: S Ta - Frotrt: To: = Frortc Toy _ Profit: To: - Ftom: To: Taal WatttaaFla~ _ _~ (Int#idas tnofrMtte Aatiad xdtlt:tl, generadeaf trladc amo~cs. ltagpMeabie) t~ocsss upset b esctian of realty X FlarYtg 6or drYlsita tttsadowt I startup ~ system testirlp Fatthy shut0owrt an FaaTayr trtainoaetertea _...~~ Hiphamttisnttbetperalwes. SfD on high v~ratiort x OTher: Initial sranrp of attkte facaihr and dnlleita. Stebif¢ed teCildy process and operation Rspafred equfptt:ertt difliNities wqh FataTdy mainianance oompl0ded x Qther. Startup and wrraltissiOnllg of gas train. Did irtoidertt cause Dladt smoke? Yes: ~ Ntr. L7 (If Yea. cantlnue wish flan section) Did incident present a potential fltreat b human health or saf~+? Yes: Q tJo: L7 (If Yon. report to FFC as soon as possible. If No. report to ADEC wHh 24 hours.) Biadc smoke soaped from source: t.P Flare CF-x-03b012 (enter ~g number anG tleSCrii~don) Notiliad ApEC by Faxon: Gate: Time: Report the faifowirtg Infonnatlon fo ADEC witMn tiA hours er +stc I@oY,2asa3aa-: Data and tote of blade smoke ev~ertC Ftrom:/!-~3 ~~ aD=a~ 1~~.~ To: ~I ~l • 0 d ~3F.'Ot1 ~-s Vaume flares whidt generated blade smoke (it dMlerertt from above): MSCF BsLs DeSixlptiort of steps to mitim¢e emissions: See Sadtort B. al>'ove. Type d rnstarbds bumad: Gas: X NGLs: Outer: Genera) Weather: arTempetawre: -- Wind SpeedlDiretxiorr: a1 s ~~'~ Name ant! phone number of pennon making the -eporC Thomas Manson 807.670-42x0 Name Pltocte No. Based on infonnatlon and belief fomted after reasonable inquiry. I certlfy that the statt:ments and inforrrtatiort in and atlached,to this documtatt are true. atxurate and complete. Fadligr Supervisor pate S D 4 ca Eoe Supervisor. NRB 6 tttaro gas and black smoke irttadents) Field F_rtvirarurtrxnal Compliance t;oorrrinaoors, PRB 7 (Blade Sntde~s hddents only) PBWGt~'MA Field Managers. (Black smoke incklama ony) GPMA Operatiotca Bitginee-lrtg Technical Aida, (GF'MA ropotts ony - ATO 477) Kuparuk: Field trrtvkvrurtertfal CompQanoa Coordinators. NSK l3l (flare qas and tttadt smoke Int~dettts) 11-2T-00 18:25 From-ALPINE NS~T1' + T-325 P.09/12 F-282 FLARE GAS VENTING REPORT PHILLIPS ALASKA. INC. • PRUDHOE BAYIGPMAIKUPARUK FACIt.t1Y: ':Algiula•Dalnafoprttertt:FhYaltl~" Pts'RMIT N0. •y Y•~ [: ~~ „~:t•i.' GAS DlsposmoN Date of ocwmettteee: 11-,~ a- d ~ i7 ~ ^ ~ ~,~ oto~:»r,~a: t~~hrY) (check selacuon) 24~Q ~ Fra7n: N~~~~ ~' C~dL To: p = Total Volume Flared: a~ 7.2 MMSCF BBLS From: To: _ Flom: Ta: - ~'.;;: Maldt<.a:%> 'S~•%~°.• tfly.Fad .,;~ OPtanrKd ^tMganred From: To: - ( Seierxiort) From: To: - 3S O • ! From: To: ~ Total Minutes Flared: - ~-~ {L}db{Irne d11y - Gil Amed ttRis howl ^ ^ dower~n (L7reaR One/ (/flClfld@3 VChRA9 ~d W/!~J ~BllBlBted b19L11C SlhOllB, aI TFG awltactarmtNeratl~ r7appdca~e) a c.serlpaon et lncla.st and Cause: (Check as nwa as nailed to fulhr dest:rlhs th. inc+a.m) sID TICS for Process upsac in T1C SD sue to twph exhaust temperatue seotlon of iaci6ty Seal oA syetern ditraities X FFarirlq for drtlhite shutdown ~ eau l~IERGEVCY SttllTpOWN Flare system testing Eleclritwll ! It15M~fhD11f8d011 frlal(unplOn FatMty 8f 1utc101M~1 on Elemicei / Ine~umenfation mattunotfon _ Faoiaty malManence at oglsr taciliry (r3D) ~ 1ig1+ amlient temperapsoa. GAa a8f19k Bya6afrl OY9rp18nSae 3N t]rl lll~t Ylbr8t101'1 heddnp CPF1FIOw Station out X Other: InMlal stamp of Alpine fadfdy t3~ssds / tmdrident inlet t~ and dnllsita: r8tas IrItD taality B. Acaorl Takeo m Ellrnir1a10 Canes sail Peaoe:d Reaw-sete: (Ctteok and deeerfbs as appicabls) Started /restarted Tic # Compressor I train deprt3sstu+ad Reduced !increased inlet gas rates Completed tiara testing Cortecteo E8d fluduatlon ! tafltre X cattecosd t?81 flut~tlatial !failure at other Eadlky (Td,D) Stabilized facikiy process ono operation Repalrod equtpmertt di~cu{ties with FactTa- maintenana3 ocmple0sd Other: SterWp and corttrttissiotthlg a{ 9a5 tram. Did inadent cause black smoke? Yes: ^ No: ^ (If Yes. continue widh this SectbnF Old incident present a polentidi threat to human health or safely? Yes: ^ No: D (If Yss. report to FEC as goon as possible. ft No, naport to ADEC with ?A ttoura.) eladc srrloke emitted from source: l.P Fla-e CFTC-035012 (enter mg number an0 desCfiption) Notlflect ADEC try Fax an: Date• Time: Ropolt ttw fotloarln9 inliersraaoet /o APEC within 24 IwIRS (8W,z9a-7SO~: ! l- pate and time of baddt smoke svertc Fram: 1 -,~ .Q~ tom: dd To: ~ r,La -0 0 a~.'T~ ~ °~ Vdurne dared which generated black smoke (if ditferenctr+om above): MSCF BSLs Description of steps to minimhm emissions: Sea Section t3, above. Typo of materials burned: Gas: x NGIS: Other: General Weatlter: Air Temperature: ~'7 ~' Wald Sp98dIDk+scxial: 7 ku S Name and phone nuntbar of parson malarlg qle report: Thomas AAansan 907-670200 IYarrle Phone No. Based an iltonttad0n and belief tamed after reasonatlle inquiry, I certify that the statements and iniormatl4n In area documetlt are true. accurate and complete. ~.~/ / / /J 11-2T-00 18:26 From-ALPINE NS~tt' FLARE GAS VEMriNG REPORT ~3i1G4. INC. • PRUDHOE 13AYK3PI T-326 P.10/12 F-282 FACII.JTY: •'•AlgipO€tXdyalop ttlant••F'~eit•~' PERA~T NO. ...,,. • :: ~'• " •tt0'~~'ACOOI~`.c:"',•. , Date of aceetrnenee: t1-~ -o o GAS d18Pe~,p70N ~ ~ n,-~ Ttnre ei< „~• (mnvddlyy) (Ct~edc Selection) ~ d From: ~' , To: d = r~ ~, • Total Volume Ftae~ed: ,~q. O M MsCF 98W Ftam: . To: From: To: _ Na:~:1` • 1 ~ ) <: >. , ~ ('tamed O ~~ From: Ta = (Check Selection) From: To: - Ftttrtt: Ta - Total IAtautae FlarrO: l aMY - Gas ttarsd was from ^ w~ssm ^ Oorer~eam (cn«yr on.) bl TEC corsaesorrnsrar at LPC} (/r>cltxfe8 vdlNtta flared which ~anaral6G1 WaCk Smoke, .. M~1 a eexrtpnon of mddan acrd causes (Cheek as any as naedod to futy aesonbe tt+s incidanu SID TACO fOr 71C. SP..due io -ri9A ex1-awt tempenuue seal oil sysprm dtl6wtties B~RGENCY Stllll'Ct)VVN t~edrical / InSbUnlElrf8ti0r1 rrlatiunaion t7e~:srirai / Instnanentauon mnMwwbon a: other raarny (rao) teas barisit system avorprasaae pac*Urp CPF1Fbw Station out Eteeealva / insutTideM inlet pas nrYtt Ytro fadiky ~. Aetton Taken to Eliminad Luse and Prwsnt Rswxtenee: (Check and dsseilbs as appikabls) Smrlad 1 restdrdld TIC # Compressor / train aepressured Reduced ! hrxeased inlet gas rates Cflrnpletea flare ~g Corrected E&1 flttcaratlon /fallen: Corrected ESI flutfteatien /(allure at othef fac~ity (T8D) Pn7oess upset M eeodon otiad6ly X fiaAng for driilaita starrdorm / sar4ip FFare sysbom testkrg Featly ihultlOrrn on FaKalily mairderenoe litgh smbiertt eemparahaes. SIG on high vibration X Other. Initlal starup of Alpine faC~lty and ar~lsne. StabT¢ed fadtity process and operatbn Repaired equipment ditTicedties vrgh Fadlily maintenance mntpleted X Other: Startup ana Commisslonln9 0 strain. Did irtddent cause bladt smoke? Yes: D Na Q (tf Yes. Continue with thts sectfort) Dld 'strident present a potential Gtreat to human health or safety? Yes: Q No: p (If Vas. repoR to FEC as soon as pvssiblA. K No, report to ADEC with 24 hours.) l3ladt smoke emitted from source: 4.P Flan. CF-X-035012 (sober tag number and description) Notified AtiEC by FeX on: Dabs: Time: RapoR the tolbMng iMeretalion m AGEC within ?A hours f 807,Z0~750S1r t3ate and time of black smoke event: From: lod DA' Dr) To: !'~ %ZJ - d p -?y~4Q Volume flared whidt generated blade smoke (N different cram shover MscF BBLS Qesalptlon of 6b9ps to minimise emissions: see Section B, above. Type of ntadsrlals burned: Gas x NGIs Outer: Certerat Weather'. Air Temperature: Q _~ Wind Speed/L)irgGtiotY $" s ~`~~ ~1pme.alK1 phone. number of parson ntakin9 the report: 1Ttornas Manson 90770-4200 Name • Phone No. Based on irrtotrrration and belief tbmled after reasonable inquiry, I oaRily that the statements and information in and attadled fo this document are true, aasrraate and complete. Fadlitysupervftior 1~ f~~ ~ Date ~/ S ~O e~ FOC Supervisor. PR9 t3 (flar+e gas and blade smoke incidents) Field F-rwirorxnsndl Compliance Coorrtinatara. t?R9 T (Blade Smoke inc~den~ ony) pBIUGPMA Freid Managers, (Slade smoke inddenfs only) GPMA Qperatlons Engineering TpCFtniCal Aide. (GPMA reports only - ATO 477) fCeparuk Reid F~tvirnnmental Compfiarx:e Coordinators. NSK 61 (flare gas and blade smoke indderttS) UpOmetl: F9G efGO Pitrot,ps~l McIpIFEn111tWan~verK.~1o~1CarM7ka RePOrt2.as 11-ZT-00 18:26 From-ALPINE NS~tT PHII11P3 FLARE GAS VEN'~ING REPORT ,SiClfv INC_ . PRUDHOE BAY1Gt~l T-3Z5 P.11/12 F-ZBZ FAdt.tYY: , Alpfi~'1~%abpnlarlf;F!i+Rla'Ct•~: PEItMR N0. ", ":':';•~310i~109'•~ ~•: gate of occurrence: r ~ ",2 ~ ^ O D O tea ^ vent (mrNdd/yyl iCttedc Selection} Totat Volume Flared: '~9. 8 MMSCF BBi~S tOt';1'1i7~:•"3.S :f• Fac x;•;: ~ l-IhrMdd ^ tkpaMOA (Check Setedlon) Nsbtrrne ar+r -Gas Barad was A'onr ^ ^ eoMrra>ean (swat Ora, a ~ ~tacbormeeer ar rpc~ a oesatptlon of tncwene and Csuee: (Cheek a< nw,y as aaeded to tulh dsacriba ttts rndd.nq SfD 7R~r far T!'C Sp duels fiign exhaust tamperawre Seal ell system diffiaities B~A~tGENCY SHtITn0~ Qeddcal / Instnarteraatlon meaunaian Eleosiral / InstrunetiYdtiaf malhutgian at oihar faeiMty (TSD) ces transtt systorn ovarwa~ae tfaddng CPF-ROw Statlon out Eppaeahre / insrd~raerrl irtlst gat raters IntD (acNkY B. ACtiOP Talosn t0 t.tlminata tauara end Prevent Racunertee+ (Cheek and doeQibO ire appNeable) Sttsrted / rRed T!C >Y Contpre9sor / train cfepressured Reduced /increased inlet gas rates Compledsd fldr+e testYtg Conecte0 EBrI fltK.tuatlon / Eaoure (:ortetxed E8I ftuduation / falktre at other testify (T8D) TIl17A of t]enrera.~ !?9:98 2~ hUau~ta/sq Finn: ! ~v To: oZ : L'a = ~L. From: Ta - From: To: Front To: _ From: To: Ftttrn: To: _ Tobl Mlrwles Flied: ~ ~ T (llKr~lrffe8 UO/fMt9 Haled rrhlClr gerlerdllt-d bRsck s-rroJce. ~~ Prooese upoet to sector of faeN(ty X Haring for drilisita shutdoavn /startup Flare syerem farting FeuKy 3nYttlOrM11 Orr Easily maietananco Kielt amblers tersrpe-egmas. • SfD on high vt~xatiort x other: Inldal starup of facirty and drftlsNe. Stebifaed f~1iH Process and operation Repaired equipment dHftatltfes with FacUlry maintenance completed X Outer: Sbrtu and commissioning o gas train. Did (nddent cause black Smelts? Yes: O No: ^ (tf Yes. continue with this sacdon) Did inddent present a potential throat m fiuman health or safety? Yes: ~ No: D (H Yes. report m FEC as soon aS possible. H No, eeport to ADEC with 24 hours.} Black sntoka emitted tram Sotuce: LP Flare CF-X-035012 (setter tag number and dascriplieofl) Notified AtlEC by Fax on: 17ate: Tuna: Report the foilowlnp Inforrrranon m ADEt: rvkhb :ta hours gY FAX i~'t.~BS-7s0oj: ~4 U_ z.~' t~1 Date and time of tNadc smoke event: From: ~ -~ ~ • dd ~fd8 To: ~j'z~ + Volume dared which generated Uledc smoke Af dlffarent from above): MSCF 138LS Description of steps m minurtlze entisskms: Sea SadiOD [~ above. Type of ma0odals firmed: Gas: X IJGL.s: Other. General Weather: AlrTemperahtre: wnd SpaedlDiredlOn: L9 e~•'b ~' - - .~(8meat7p phone number of ptirson making the rt.port: Thomas Manson 907-670.4200 Name Phone No. Based on infomsation and belief forrrled agar n:asonable inquiry. l csrtlfy shat the statements and irtfortttatiOn in and atmched to this doatntent are true, acwrate and onmpletaa. oats S Facility Stspervleor Y ~ - -a s7 w~. - • tx~ FAC Supervisor. pR9 ti (flare gas and blast smoke incidents) . Field F_rnrironmental Compliance Coordinations. PRS 7 (Black Smdce incidents ony} PBtVGPMA Field Managers, (t3latlc smoke Inddenbs ony) GPMA Operatlons Eng•"in9 Technical Aide. (GPMA i+eports fifty - ATO 477) lGtpanrk: Field EnviroranenbJ Compliance Coordinaeors. NSK 61 (flare gds aM black smoke incidents} h~ 6100 t~elplFenrrelPler~VerN_AlantArroNe RCpef~~ds 11-Z7-00 18:27 From-ALPINE NS~1T FLARE GAS VENTING RE.PURT PHILIPS ALASKA. INC. • PRUDHOE SAY/GPI FAgLITY: 'Alpine ga~naloartrerttPfv}ed' Pate of occurrence: ~I ` ~~ ' t~~ 0 Flan ^ Vent (n-+~d~YY) (Check Selertiort) Total Volume Fisted: ~3~ .J MMSCF BBLS Mgter:No~ .3$ -• ( . Faeilill-1' . ^+ Pmnnea ^ unplenrk0 35 0 ~,~ ccnedc seiecGonl (t.isbtJrne CJJy -Gas AJ1tOd was horn ^ ^ dowrtsoeam (arse orr) of 7EG oorRadarntateletLPC) A Description Of Incident and Cause: (Check as many as needed to fatly desa lbe the Inedderrt} SID TlGi for TI'C 5D sue to high exheua taenpaaare Seal al system difficultles EMERGENCY SHUiDOwN Elee~ical / lnstnurfertraoon won Eleruical J Insbtettefltetbn rt18J(unraon at other facility (1'SD) Gas transe system nverPnrssur'e peddng CPF/Flow Stadat cut Ex0es6ive / insu(fid'eJlt In18t gee rates intolaality 13. Aegon Taken to Ellminete Cause and Prevent t2ecurrertee: (Cheek and describe as appUpble) Started /restarted T1C ~ Compressor /train depressured Reduced / ina>cased inlet gas rates Completed flare testing Corrected EBd fluctuation 1 faUure Conected E8J flucaJadon /failure at outer fadfdy (T&D) T-3Z5 P.12/1Z F-Z8Z PERMff NO. ~ • QOT ~-A~011~ •'. • .. Fran: ~~ Tp: ?, ~ rl'~ r,~-- _ ~~ From: To: - - From: To: _ From: Tc• From: 70: Frtirc To: _ Tool Minutes Flateds a l T N (lnekrdes yokRne dared wf licit •genarrafed black srrroke, if apP6cablel Process upset in seeGOn of faciUtY X Flaring for dn1lslDe snutdown 16tttrtup flare sy6lem tasiin9 Faulty 3rkritiDNlln On Fseiltty rnairrtenailce 1119h ambient tamparaturos. 31D tit high vitiation X Other: Irittial StaRrp of Alpine faality and drillsite, l Stabilmed taaligJ process and operation Repaired equipment difficulties wltlt Fsality maintenance completed X Other: Startup and txtrlnmissktning of gas train. LP knockout drum and fln fans corrtmissionep_ Did incident puce bladt smoke? Yes: 0 No: ^ (if Yes. continue with this saGfon) Did inadent present a potefttiaf threat to human hearth or safety? Yes: ^ No: D (I! Yes, report tc FEC ss soon as possible. ff No. report to ADEC with 24 treats.) Black smoke emitted irM1 source: LP Flare CF-X-035012 {enter tag number and de6Ctiption) Notified ADEC by Fax on: Date: Tirne: Report the foflowin9 IrdormatlOn m ADEC wHhin Z4 hours BY FAX (9o7,2tltt-7blltl Date and time of hladc smoke event: Frain: // ;~ ~• OD _: 0~ To: ff v~ 5`'4d _ ~ ~ Volume flared whiCtl generated bIaCK smoke (if different from shovel: MSCF BBLS Destaiption of steps to minimize emissions: See t;ectfon B. above. Type of materials burned: Gas: x NGI.s: t7fher: General Weather. Air Tetrtperaatre: Wind Speed/Direction: / D orS E Name and phone number of perspn making ttte report: ~ Thomas Manson _ 907-670-4200 Name Phone No. Based on information and beUef fomted after reasonable inquiry, I certify that the statements and infamauon m and attaGled tC tole document are true. accurate and complete. Faclitty Supervisor Data Qa caw OC Supervisor. PRB 6 (flare gas and bladt smoke incidents) Field Emironmerttal Compbanee Coordinators. PR8 7 (Black Smoke u+ddsnts only) pst.l/GPfiAA Field Managefs;, (Black smoke incidents Dory) GPMA Operatlons Engineering Technk~l Aide. (GPMA reports only - ATO 477} Kuparuk: Field Fltvironmerttal Corrtpliance Coordinators. NSK 61 (stare gas and black smoke irx~dents) Vs» FEC eA0 p, p•pFp~lFplre Vent~ladt 8n101te Repoet2ads 12-O1-00 08:05 From-ALPINE NS~IT FLARi: GAS VENTING REF~ORT T-462 P.02/05 F-480 Fndtmr: Alpine povelopment Project PERMIt t+10. 0073-AG009 GAS DISPOSITION Pate of t7cwraettce: //• ~w'4a ~t•wre pvom Ttrhe of Qccurrence- (mrruddlyy) (Check Selar~ion) ~ 2~ M!^~ Total Volume Flared: ~1•~ ~"tMS~ ~~ Fes: To: From: To: - ttllat`CrNO:r 4 ..:~: ~ •FeePlanned ^lkiplars+sd From: To: _ ,,..~_ (Check :3electlon) From: To: ~' - To: From: ° ~._ Total Mlntroes Flared: ~ /+ ((,~brrne or:ry -Gas flared was frarrr D ^ daM~arean- f a~e~ (lrtdtxles vofu-rre flared ovllkaFr generarmd bladr smoke. of TEG coruerxormetsrat LPC) ~$pPle! A. NOes:riptbn of Inetdettt and Gauss: (Ctrack °s many as needed to fully dsawtba the inWdettt) SID TIC1- for T/O SD due to high exhaust temperature Seal Ott sytaem tflfia,ross ~. p1AERGENCY St-lU7'pOYVN l=ledriCal / Inten,rnantation msitunClicn Eleririratl / Insutrmen~n mstivrrroon at other tacUky (TttD) Cias tntr>:it system ovarprasaura backing CPFlFlaw sta6orr out _._-~~- • ~~yg / InBYfflCierri inlet gas rates ItitD fatildy B. Action Taken W Bliminata Gsstsa end Proveat Reeunarwee (Cheek and deauibe ^s apppcsble) Started /restarted T/G # CottlPresaor / train depressured R®duoed / intxeased inlet gas rates Completed flare taetirrrg Corrected t/&t fluctuation 1 faiure Corrected EB~I }u,cwaUor- /failure at other fatilily (TAD) Process upsetin ser~ort of fa4lity Fierirq for tlrfllstte StatteoMrtl~ Flaro system teS>5nB Faulgr eMrMown on Faddy malrWananca liiph amhierrt terrrparaaees- SJP on high vibra3aon Other: wt WE. Stedltzed facility process and operatior- fiepnnsd equlpt'nent dffAwltbs v+%h FacfGty maintenance completed Other. rewa ~ sL ,~;~ Tii2Atsd see ~~, Qtd incident cause biadc smoke? Yes: ^ No: ~ (K Yes. continue wish this section) Did kicident present a potential threat to human heatih or safety? Yea: Q No; (If Yes, tepont to FFC as soon sa ppsylbie. S No, report to At?EC with 2li houra.`~ tag number and desaiption) Black smoke emided inxn souroe: NOtlAed ADEC by Fax On: ~~ Tire pepore the tolloerMg irgonn>dion ~ ADEC yrithin 2a hoursBY FAX t9C7 269 75119} Ddte and tune of black Smofce event: Fawn: To: Voume Awed whteh generated blardt smoke (it different from above): MSCF 13~f-S Description of steps to mtrtimirs emisstons: See Section B, above. Type at n~aterisls homed: Gas: NGLs: `~ Other. General Weaihar. AlrTemperature: Wind SpeedlDirection: Name and phone number of person making the report: phone No. Name Based on information and belief formed after reasonade inquiry, I Cernry document are true, acculdfe and complete. Facility Supervise ' Data // is ~ m updtterx FEC6r00 P:\Gtaupe\MSEr\t~virorrnenro~ HelPlFarrns\~ 12-O1-00 08:05 From-ALPINE NSt~T + T-462 P.03/05 F-460 FLARE GAS VENTING RSPORT iac er eckd ttuC_ • AtpINE/KUPi FApInY: Alpine peveloplrriertt Project Paaullt N0~ 0073•ACp09 GAS DtsPOSmoN t~te,otoccurlrnca ~I- Z~- Do OFlarr owe Thee effxenrnanea: FrotrL To: o~ O ToW Yalrans Flanrk %SL7."'1 AASI:F 1381.5 Frorrc TO: _ ._-^-,~. Ftvnt: To: - M7iC . sysp /~. f ~~erned (~ 9eteafon) From: -- Y~ ~.... _ ~~_ From: To: Tops Mirxress Flans: _ (tJsaurrle Gr>ry- sas BArad wee: !rote ^ uDS~n ^ down (t7i0C+k anal ~ndwluria 13A119d tMNdr ge~ne-aied b(adr snrOklB. a ray croraar~or'rnecerat IJ~'CI a, oese~an d tceliot and ~rsw: (t~,eac es marry as rreeesd to fupp dascrlbe tiro irrddanq i31p T1Gr for T/iC SQ ante t0 hiph extu+vet ternperehire ssal oiI 8~ eaa~u~ k i:'~IN~ s~ttiroowN paprieal! Irtadssnerrtatfon rnsthsxibn g~ioat ~ lnaetsttet~tion ntantxtction arosseire / ineuinr~ent mist qas r~ into facilRy a. Actlon Taken as ~7tn~krrree Caues area P~e•ad Roc~reMles: (Cttselt and r•see~s as appllolrMe) Sraried / rsstaroed T!C aR Compreosvr ~ train tlepressursd Reduced / 8~aeaaed kdet gse rates Completed faro taaWlg torreded Edd lktchaWon / fayure ,,,~~ CiOn>'lCtad i_dJ fucalatbn ~ relate at other fadlty (T8D) Process upsst in setdiort at tadNtY Ftarliq for drlMsibs ad>,ddowrt~ r-atnttr shtlawn an FadAgr meirtterwnos SMbinzad fadlity process and aperetlors Rep6~ited 9quiPment with Fadllty maintenance cromplated OIr1Cr:// -r`~+~~~~ I~6iri~s~SSi~/»_ ~7 ~~ C_y~ S ~1rrs~i/f ©Ana i.7 E Did incident cause bladr srrloke? Yes: ~ IVo: ^ (it Yes. cantlnue wish flis eeCtion) . Odd ktcfdent pr9sent a patented threat m human health or sefety't Yea ^ NO: (If Yes, report to FEC as soon as posslbis. h N0. report to ADEC rrNh 24 hors.) 91adc Srrlcks etdtted from souroa: tamer tag nernbar and deocriptbn) Nottttied /1PEC by Faxon: Report the tollowing irdorrrMtion Ito APBC wive 24 haurs~~ (80T,29~7tb09): area: Data and time of bMOk smoke event From: 70: Volume fared whkil @erterated deck smoke (if OHferenl from AbovsY 1NSCF BBf.S DeBC~ptlon of steps tb minirnf~ arnlssions: See Set~rl g, ebO~ve. Type of materials burned: Gee: ~ NCLs: Other. General Weather. AlrTemperamre: ~_ Wuxi SpeeNpiroctlat: Name and ptwne number of t~~ 0 ~ rePo~ ~,a t'horle N0. gpegd pre infarrrtatbn end belie) fomrad after reasonable Inqulry,l cer0ty document are frue~ accurate and o late. Faauuy &upe~vhor • alai the Staterrlenffi and eutactlee b RHO UOAIIr~ fEL`BIOO P.\G+a~1F~1ErYVNOrM419Mo1 HOIplFarrfs\-U02~9rs.~ 12-01-00 08:06 From-ALPINE NS4R + T-462 P.04/05 F-460 p{.ARE taAS VEMING REPORT ec we abrta_ tNe_. el_PINEJKUF FACanY: Alpine Developmt~lt ~O~ BAR f+fo. Q073-AGOOti GAS DtSPOSIT~ION p 1'• Z D + jJ"c~ i7R.e ^Vatt TMns of Docurrenae• L1eds of Ocowrells:e: ,~ ( (Citecic salaution) m F ~ ~~ , `` ,~ h D ~ To: ~~Q = ,, ~ 'f ~~~ ~ ro F~ ~= „Q To: ib.- Total Yolturca Placed: ~; To: - sC ,~1Pktried ' B ~F ' I~Unpstrted From: To: _ _~-. . r :C~: C2~a / ~ ~ ~ ) Check Selection Frotta To: ^ To: .^~+- /VI i From: - Ta41 MMtr~as Fiaceds (Cfebon~s arxY - Aaa frerse was boric D ui+sesxm ^ dovranesn • !Cheek ar+e/ vOS/rrJe ARrs~d wfildt pBnera~sd bNOk amrike. of 7'EG aaxeotormeterattf'C1 Geserlptiart a ttceidecct and Catteb (Check as ~f- r^ nseaed to fully doKribo the kcoidsc~t) n . srp T/Ct? for . - Pracsn ~ ~ _ T/C SD dw b hlph cabaret mmperaiuce .~ ifi s dMti eeclMX- of F~ for d~ shutdown l~ e a ~- 5est oU system Fltte>ti)l~ t7Vl 3HUTDDNM g~SCOt/ ItlbtflrllerlmtitMi fnelftrlCti~t1 ~,~ FeuilysitttldDwn on DeCtItCTi) / FnrtRrrerMeli0tl trlalhJnafOn ~~ F ~ ~~ _ ..~__~~ur_!-~M ~yy_~ ~-ufl~. if1i1101R~& ~i ~ YI~tYY.i~ B. ACt1011 Tata>t~ t0 E.°tYlll/IaIB C'iMt~O ettd Prerercc ~1n^fIC~' (CiN00t1811d d9~GItt7Y A~ ap(IltGllblO) .~~IZBd faC.llit~/ rJfOG951t AflA Qpar81lof1 Stetted /restarted TIC i - Cot~ssaor I train ~ Repaired equfpmecct difficypiea '-'- Reduced / ina+eased Inlet pas rates ""~ Compleeed flare tsetk-9 FadYty maint®nsncs completed C:orireted E6l fluoiu8fioul / faNt+re ~~_ Ofiter: ~~~~0 j~;s~[esr~ Gon~ected E8d flucptafion / teulure ~~7....,~.T!r' ~ti i5rssni nc at other taadYiy (TED) Dki Ittddertt cau80 biadc ettloke? Yea ,~ No: ^ (If Yes.: corrtirtue with this section) Did inCidetlt Present a p~ tht9at m human health or eataly? Yes: ^ No: (if Yes, eeport to FEC es soon as poss(bN. ll lVo, report m ADEC rHttt 24 hours.) Black smoke ernflfed from sourc~x (enter tap ountber and descrfptkxc) Notified ADEC bSl Faxon: ~: ~: R~ y1e tofio~ tton m noEC witltirt 24 hatn@L- EAX (~~'~): Date and time of bktdc entolc9 event Frotte To: Volume flared whk:h generated black smoke {q dHferent from shove): MSGF _~_ i38t.S D of steps b mfnitntze en>is~o~: See Sectbrc [3, above. Type of tctateAals twtnad: Gas: t~ IVC4L8: ~~= t3erteral Weather: Air Tempsrawre: - ~- ~ ~tiOr': Name arxf phone nurttber of person making ifb reporti Name Barred on irtforntation and bed6t formed after reere in fluirY~ 1 certlty that the atatemeot9 and itifwmattotl ~ doCUmettt are true. sOt:urab9 and / Pfcone No. ro are 12-01-00 08:06 From-ALPINE NSIIT + T-462 P.05/05 F-460 FLARE GAS VENTING REPORT Of flCCtlf fence: Total Volume Raced: Alpine Dev+alopment Protect ~fnirNO. (mm/dd/yy) (C`h'eck Selection) 32.0 ~ eat_s ~~ •r ~• ~ 'per DUrlp~~ M~ 3~. / (chew Selection) rcr~cums ~ - cas f~ tvas rout O ~a O a~t~n l ons- or TEA kxvrtadormeteraat..PC) Q473-AG009 TM1e OT OCCurTterM.~: ~~../ ldLbf f~d"• ~ • 1l6i Front: Q~.'OD TO: ~ ~Lb s / a From: Ta = From: To: - From: To: - From: To: ^ From: To: - ToW glintrtes Flarod: ^ pndudas valkarsa Karma urtttrafy ger-arat~ea blacit smarm, it applicable) A. t]eacription al lra9datd and Cease: (GteaK as many as needed to ttgty deseMbe the Incident) .SdO T/Ct- for TIC SD due to rtlgn extraust temperature ' Seal oil system tlilfiCttlGes y EMERQF~tCY gi-ItJfDQ1i4N E{erxrteal I Instrumerttatbn manunctbn ~piC31 / Itffitntrflenidtiott fnaHunttlotl at dtrler faCirRy (TSD) 13815 trertsft system overpressure backing t~FtRow Station out Exoe951ve / IraKdfitaetK inlet gee rates into fadllty B. Adbn Taken to Elimltlate Cause end Prevent Fieourrera:e: (Cheek and describe ae appllstiblel Started /restarted TIC ~ Compressor / train depreasured Reduced /increased inlet gas rates Completed flare testirty Corrected E&I fluctuation !failure ~,,,,,'w COffeCf9d EAdd fiuG'ttta110t1 / fatlura at other iadlity (TB~D) Prncsssttpsstin eecriort of tak3lity F7adng for tlrirlslte srwitaorw~staeo,p Flats trystem t9sting ~~/ Faulty sltutktwm on F2Wly rttalrtterta<rtoa Ffigh ambient tettitperacaes. • SIR on high vibration Q { '~ e . !r d j r ,' r Stabilized facility process and operation Repaired equiprneM dtffioultiea vvtttt Facility rnairrte ante completed er. ,~r5~~[ ~ So/lj~ ~~' 'G7 /r~ nr~r., .~ ~~ ra J Did inadettt cause black smoke? Yss_ O No: ,~ (if Yes, continue with this section) Did inadent present a potential threat to human health or safety? Yes: © No: (If Yes, report to ~ as soon as possible. if No, report to AdEC with let hours.) Bladk smoke emitted from source: (enter tag numt>~ arw description) Notified ADEG by Faxon: Oats: Time: Report the following lntonttstion to AbEC within 24 tawreBY AX (907-2t~•7508): pate and time of Black smoke event: From: To: Volume Bared which genstatt3d black arrtvlce ('rf cflfterartt tram above): MSCF 881.5 Description of steps to minimize emissions: See Section B, above. Typo of maieriais bumt~ Gds: NGLs: other. General Weather. AirTemperaurre: Win Speed/DirecUtut: Name and phone number of parson making tl>e report 1~A/1! ~/UD~S Name t3R8ecforl inYormatiori and tietief tprrl'1ad'atTBr reasonaole tngwry, t cerory doatmant era true, amuats and / FaOllity Suparvkiof ~~~+~-•' FACILJRY: Date ~~ ~~~ Phone Na to upaana FEC tYOD P16toupslnSETErnkaYneraor Me~plrams~-~0022evexis 1Z-06-00 08:23 Data of Occurrence: Tote{ votuma Flared: Frtfm-ALPINE NS41T FLARE GAS VENTING REPORT FACIY ITY: AIpU'1A pave i (mnv a/yy) Profeci PieRMR N0. ~rrare l7Vcnt (Ct-adt selection) ~3. iap ~ MSCF ~- BBLS • rt+foM•:•:•:•:•:•:•:••~ •:•:•••'•• B• •Faoi 1~Piemea- l7unpr,nnnd m~ ~j i t (Check Selection) MTR~- 350(2 (CJspurrte orily -Gas eared was tram ^ upsbeam ^ downstream (L'Hedc OnoJ of Tl=Ci canr~tormeteraf t.PC) From: f=rom: From: From: From: From: T-608 P.07/07 F-663 0073-A0009 Tiime of Occurrence: i0~ Ta: ~y:db fl ~Q~ To: _ To: - Ta ToW Minutes Flarod: . 1 Q (includes volurlte flared yyhich generated DlaCk 8rr1alre. if dppliCablej A. DesCrlptlon of IncidsM and Cause: (Check as many as needed to fusty doscnbe the irtcidanry SID T/Crf for Process upset In TIC SD due to Ngh exnattst temperature section of fadlily Seal oil systam• difficulties ~~ Flaring fOr driflaits ehrrtd / stanup EMERGENCY SHUTDOWN Flare sythem 9 Eleruiaal / Insmrmerttatlon maHurtctien Faulty sfwtdawn a- EleCflriCai 1 InstnrmentatlOn malfunction Faewry mafntanarxea at other fauliry Cr&D) High ambient temperaArr+as. Gastraneit system overpressure SIG on hi h vibrariort backitg CPF/Flow Station out ,~~ ~~ ~ Ettoeseivs / insutfiCfeM inlet gas rates Ir110 facdiey f3. Aadon Taken to Elienlnets Catraa and Prevost Reeurronee: (Check and tlosedfre as appileebla) Started /restarted TIC a Stabilized facility process and operation Compressor /train tlepressured Rapairetl equipment difficulties Reduced /•increased inlet gds rates with Completed flare testing Facility mai to once completed Corrected E.81 fluctuation 1 faUure ,~ Other. Corrected E&t fluckration !failure at other iaciliry <T&D) Did incident cause blade smoke? Yes: ~G No: C7 (If Yes, Continue with this section) Did incident pretaent a potential threat m human health or safety? Yes: D No: (If Yes, report to FEC as soon as possible. If No, report to AbEC with 24 hours.) Stack smoke emittae from source: }~Q~(_P ~.. i't (enter tag number and description) Notified fiDl=C by Faxon: Date: .~ Z2 L~:!<d I I ~~7 Tirne: (St'CQrt'1[:.i l S RapOR tiro follotAleng infarnredort m ADEC.watln ?.4 houraf3Y FA (907,269.7f~48): Date and time of bladt smoke evem: From: r,p;o J 4la,a To: Ludo Volume flared which generated blade smoke (ff different from above): MSCF BBLS pescription of steps to minimize emissbns: Sao Section B, above. Type of materials purred: Caatr: )C NGLa: Other. General Weather. Air Temperature: -- i ~1 ---- Wind 8peedJPireetion: /(/~ '7' K~o Name and phone number of person making the report: ~ 5 _i'T/,.ir'1/~on D o r"t s~•P: j f y ~Tdv~r~ M~a SOn ~07-1p7 d ~ ~ ZCK~ Nartie Phone No. Based an information and belief fomted after re able inquiry, I certify document are tn,A, accurate and comps Facility Supervisor statements and information in and attached m DdtA ~ DI t34 tJPdsurk FEC BreO P.16roupctHSET\Envi~onmen*a Heiplrome\-m22896.bs Colville River Unit Field Startup Summary so 70 60 D V y 50 0 a 40 O m ,;; 30 R 20 10 0 - - +~ - -Oil Production, MBO - - f - -Gas Production, MMSCFD - - - -KRU Fuel, MMSCFD - - t - -Fuel Consumed - - - -Gas Injection, MMSCFD ~ --•--GasFlared,MMSCFD ~, ,^..-^--^--^--~--^--^--^--^--~--^--^--^--^--~--^-- -+--Actual Oil Production, MBO ,- -F-Actual Gas Production, MMSCFD ,-` , ~ l MMSCFD t l KRU F A ' , ue , c ua ~ ^ -+-Actual Fuel Consumed, MMSCFD ~- ~ Actual Gas Injection, MMSCFD , ^~ -+~-Actual Gas Flared, MMSCFD ,-• • ,^' ~ LP Comp Startup :~~' ' • ASV n~.--. •1~FR rv ~ - 1~.. ~®. + i -® ~. , y ® r' ~-- 3- - ZC.-..~ • a • - - - -, d ~w s Y •r p 0 5 10 15 20 25 30 Days after Startup ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition ALPINE PROCESSING FACILITY PHILLIPS ALASKA, INC. ALPINE 12/00 Disposition Volume MCF* 1. Sold Condensed Gas 323,297 2. Reinjected 830,991 3. Flared or vented less than 1 hour 0 4. Flared or vented greater than 1 hour Su lemental re ort re wired--See 20 AAC 25.235 428,942 5. Pilot and Purge 0 6. Used for lease operations Fuel Assist 34,337 0 7. Other TOTAL items 1 - 7 1,617,567 8. NGL gas equivalent produced 0 9. Purchased gas 252,587 10. Transferred from: 0 11. Transferred to: 0 Remarks: I hereby certify that the foregoing isis true~ct to the beCst of my knowledge. Signature: ~~ Title: e~V`PV ' Date: ~ L 0/ *Indicate contribution of each pool to total. Pool Name I Code (ALPINE (ffcfal Lise:C3rsl~'=:~tari~i` : Autl~itizatiorr> 1: tir;~:~:~::< :~: 1. Safety MCF 2. Lease Use '`~~ ~ ~' ; ` 1 ~C ~ MCF 3. Conserv. Purposes MCF 'Y~ Commissioner ~ ! I , b ~-- Date Percent 100.00% ~~ ~~ JAN 2 ~ 200 ~ ka Orl & Gas~Ccns. Comm+ss;~, Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ;~ '~~~~~ •Y (/ Form 10-42 evised 4/95) Alpine Crude and Gas Condensate Allocation Production information and well tests suggest a large quantity of natural gas condensate is being formed in the Alpine compression train. The evidence for this is a relatively high oil allocation factor ratio for the Month of December. December AF =Metered Sale Volume /Estimated Theoretical Volume = 1.141 This phenomenon was not a factor in the month of November because the compression train was not in operation between Field start-up (November 15th) and the end of the month. During most of December and all of January, Alpine condensate has been mixed into the Alpine crude stream and sold as product. Periodic well tests allow us to estimate theoretical oil, gas and water production for an allocation time period. Because test equipment cannot compress and condition the gas in the same manner as we do in the production stream, we are unable to make corrections to "theoretical production", which is the denominator of the allocation factor. In order to accurately report mass flow at the well level, we have chosen to calculate total condensed gas production and reduce total crude volume using the following methodology: Condensed Gas (MCF) _ (Inlet Separator Gas + LP separator Gas -Gas Lift Gas) - Flared Gas -Produced Fuel Gas -Injected Gas Condensate liquid volume. is calculated using the following conversion formula derived from condensate stream characteristics predicted through facility process simulation runs: Condensate (bbls) =Condensed Gas (MSCF) x (1000 SCF/MSCF) x (mole / 379.4 SCF) x (55.5728 Ibm / mole) x (cu.ft. / 35.7275 Ibm). x (bbl / 5.615 cu.ft.) Estimated condensate barrels are subtracted from the net (dry) metered crude volume. The remaining volume of oil is then. used to allocate oil production to each well. Using this methodology for December, the overall monthly oil allocation factor was determined to be .9884. This value is preferable to the uncorrected 1.141 ratio and suggests the gas to condensate conversion technique is appropriate. The overall gas. allocation factor can be calculated as follows: Gas Allocation Factor = (Total Gas Production -Condensed gas) /Theoretical gas production For December, the above equation yields a ratio of .9221. This is somewhat better than the 1.1444 gas allocation factor calculated prior to the correction. Once the Alpine miscible injection. (MI) blending unit is commissioned, we anticipate a large portion of the condensate stream will be blended back into Alpine produced gas to manufacture miscible injectant. If in the future most of the condensate is utilized to make MI, it may not be necessary to undertake this correction. We will not be able to determine this until the Alpine production facility is stabilized in its permanent configuration. i. Q ~~ 0 `'t+~ N :~ rR"^' I.CJ Nei ~ c9 C~ (,~ O Z {J Q ~~ Y N tQ Flare update - 12/12 Subject: Flare update -12/12 Date: Tue, 12 Dec 2000 02:07:22 -1000 From: "Michael D Erwin" <MERWIN@ppco.com> To: Wendy_Mahan@admin.state.ak.us CC: "Mark M Ireland" <MIRELAND@ppco.com>, "Brian D Richards" <BRICHAR4@ppco.com>, "ALP Env Coord" <N1508@ppco.com> Wendy, As you will see on the attached plot, this weekend we successfully fired up the HP compressor and are now injecting gas in wells 1-06 and 1-31. This week we expect to begin curtailing KRU fuel gas as we shift onto our own, and line out both LP and HP compressors to smooth out plant operations. Gas injection metering has presented unexpected problems, but we continue to press toward resolution on this and other similar control/automation issues. I will be in Bartlesville for the week ,but wanted to get you this update before I left. mike (See attached file: Flare Update 121 l.xls) ..__,. Name: Flare Update 1211.x1s Flare Update 1211.x1s Type: Microsoft Excel Worksheet (application/vnd.ms-excel) Encoding: base64 '' Description: Microsoft Exce197 1 of 1 12/13/00 8:16 AM Gas Disposition Summary Colville River Field Gas Disposition Form 10-422 Incident Summary Page 2 December Overview The Colville River Field sold oil into the sales pipeline for the first time on November 15. First oil sales began following commissioning of the oil train and associated modules. The gas train was commissioned to begin gas reinjection on December 9. Flaring continued throughout the month: The field has continued operating on Kuparuk fuel gas for several reasons. During the first half of the month following startup of the gas injection compressor problems with the fuel gas dehydration and associated automation system prevented the field from generating sufficiently dry fuel gas. Unexpected field shutdowns plagued operations throughout the month. The primary power generating compressor to date is incapable of starting on diesel, making it critical that a continuous supply of clean dry fuel gas is available. Shut-in of the KRU fuel gas line is expected to present significant problems during a restart from natural gas liquids condensing along the cold line. Low levels of black smoke continue being reported from the LP flare. The opacity ranges from 0-15°Io depending on operating conditions. The flare tip manufacturer is currently building replacement flare tips that are expected to remedy the problem. During the month several additional well flowbacks were completed. Efforts to complete the remaining injection well flowbacks were thwarted by weather, the holidays, rig location, and startup activities. Additional work in this area will commence in January. Where differences exist between the flare volumes reported in Flare Gas Venting Reports and the volumes shown below, the volumes shown reflect corrected and allocated volumes for the time period reported. In accordance with 20 AAC 25.235(b), the following releases are included in Form 10- 422. Supplemental information explaining each event is provided below. The following are well events exceeding the 1 hour limit. Date & Time Event Summ Gas Volume 12/01/00 Initial startup of the Alpine Facility. Gas train 36,898 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 12/02/00 Initial startup of the Alpine Facility. Gas train 36,880 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. Gas Disposition Summary Colville River Field Page 3 12/03/00 Initial startup of the Alpine Facility. Gas train 38,830 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 12/04/00 Initial startup of the Alpine Facility. Gas train 37,049 00:00 to 24:00 commissioning is ongoing. The presence of black MSCF smoke could not be observed due to sever weather conditions. 12/05/00 Initial startup of the Alpine Facility. Gas train 37,877 00:00 to 24:00 commissioning is ongoing. Black smoke was noted in MSCF spite of continued severe weather conditions hampering the observation. 12/06/00 Initial startup of the Alpine Facility. Gas train 36,821 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF reported regarding the LP flare. The gas compressor train was fired up and shut down due to foreign matter in the Tube oils stem. 12/07/00 Initial startup of the Alpine Facility. Black smoke was 31,135 00:00 to 24:00 noted and reported regarding the LP flare. Restart of the MSCF com ressor is imminent. 12/08/00 Initial startup of the Alpine Facility. Black smoke was 33,262 00:00 to 24:00 noted and reported regarding the LP flare. The MSCF compressor came online today for brief gas injection eriod, but was terminated to re air flan a leaks. 12/09/00 Initial startup of the Alpine Facility. Black smoke was .18,429 00:00 to 24:00 noted in the LP flare. The gas compressor train came on MSCF line in~ectin as into wells CD1-06 and CD1-31. 12/10/00 Initial startup of the Alpine Facility. Gas train 16,371 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 12/11/00 Initial startup of the Alpine Facility. Gas train 1,953 00:00 to 24:00 commissioning is ongoing. Black smoke was noted and MSCF re orted re ardin the LP flare. 12/12/00 Black smoke was not noted in the LP Flare. Gas train 16,455 03:00 to 20:00 commissionin is on oin MSCF 12/13/00 Black smoke was not noted in the LP flare. A faulty 8,950 00:08 to 04:32 vibration switch shut down the gas injection MSCF com ressor. 12/14/00 Flowback and unload well CD1-36. All fluids are 299 MSCF 07:45 to 18:15 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the tanks durin the o eration. Gas Disposition Summary Colville River Field The f~llnwing are well events exceeding the 1 hour limit. Page 4 12/15/00 Flowback and unload well CD1-42. All fluids are 208 MSCF 10:00 to 24:00 contained in tanks set next to well CD1-45 on the south end of the drilling pad. Gases are vented directly from the .tanks Burin the o eration. 12/16/00 Black smoke was noted and reported regarding the LP 12,471 00:00 to 24:00 flare. Compressor section gasket leaked gas into MSCF module and SD in'ection. 12/17/00 Flowback and unload well CD1-45. All fluids are 295 MSCF 09:15 to 20:30 contained in tanks set next to well CD1-45 on the south end of the driIling pad. Gases are vented directly from the tanks Burin the o eration. 12/17/00 Black smoke was .noted and reported regarding the LP 16,400 07:30 to 16:15 flare. Repairs to the gaskets are ongoing in the gas MSCF 19:15 to 24:00 in'ection module. 12/18/00 Black smoke was noted and reported regarding the LP 16,100 04:37 to 20:18 flare. Electrical malfunction caused lant to ESD. MSCF 12/22/00 Black smoke was not noted regarding the LP flare. A 15,400 14:39 to 24:00 rocess u set in the as train SD the com ressor train. MSCF 12/23/00 Black smoke was not noted regarding the LP flare. 2,300 00:00 to 03:28 Efforts to restart the as com ressor train continue. MSCF 12/24/00 Black smoke was not noted regarding the LP flare. The 110 19:51 to 21:21 power generating compressor went down taking the MSCF entire lant down. Total Volume Reported on 10-422 Line 4 414,493 MSCF 12-0~-00 08:23 From-ALPINE NSffIT + T-608 P.06/07 F-663 FLARi; GAS VENTING RPPORT PHILLIPS ALASKA INC. • Al_p1NE/KUPARUK PACII.fYY: Alpine Developm>mnt Project PERMR NO. 0073-AC~9 ~.,AS _FSISPOSITIf]N pate of pccurrence: ~~ ~~~~~ }$[Fl~m ^veat Time of t? currents: (mm/dd/yy) {Check Selection) 9Q.'{)Q 24:!?Q ~/ From: To: _ Total volume Flared: rTV~~~I M3CF BBLS From: To: = From: To: - l1A hJ~io:~ :::::.::::::::::.•. 8 •F~lcl ~Ptartneq ^Unptanned From: To: - Tl~ .... aI'~-- (Check Selection) From: To: From: _~ 70: ~ 7 TDtal Minutes Flared: = 1 (Llsbume Onty -Gas xan9ar was tAOm ©upm+eam ^ downweam (Cnerxr Orre) (lrfdudes volume Rar>3d wllicxf generated tflack smralre, of TEG oorrfadd'meterat LPoC) if appliCdble) A, t]escription of Incident and Cause: (Cheek as many as needed to fully doSCrlbe the tt-cidem) SID T/Cd for t•'roeess upset in T!C SD tlu®t0 high e7rhaust temperature Sei;dM Of facility Seal ail system diffitwities ~ Flaring for drllislle shutdovm etattup _ _ EMERC,ENCY SF1t1TDOVYN Flare system testing i=lecmcal ~ Instrumentation malfunction Faulty shutdown en Elecuiaal 1 Instnsmenration malfunction Facility maintenance at other iadlhy (TRP) ~ Filgh amtrem temperatures. Cae transit system ovetpresaure ~ SJD 4n h' h vibra4on backing CPFIFtow Station out ~:--- Other: ~~/" 7F6t O~ F~ccessfve I Irtsutficient Inlet gas ~,p~'Q,G ~ G s'/. ~y ~1,1~ rates into facility • ~" r.•/ /~. ?~ G _ _ _ _ B. ACtiart TaKen m Eliminate Cause and Provent Recurrence: (Check and desCfit>t es applloabie) Started I restarted T!C a Stehilizetl faoiliry process and operation ~'- Compressor / train depressured ~...r-, Repaired equipment tliKiculties Reduced /increased inlet gas rates with ,~_ Gampietetl Have testing Facility maintenance completed _~ Corrected E.d~l t-uotuation /failure _,~~ Other: s Q~i~ Corrected E8,1 fluctuation /failure i d at ether faality (T8D) e.~.~ +`ya Black 9m°1ce Did incident cause black smoke? Yes: No: iwt~lM (If Yes, continue watt this section) Did inryclent presAnt a potential threat to human hearth or safety? ~ Yes: ^ No: (tf Yes, report to FEC ds croon as possible. ff No. repoA to AbEC with 24 boars.} Black sttloke ammed from source: L7? ~ (ctt- ~ (enter fag number and descrlpflan) Notified ADEC by Fax an: Date: l 2.t~ o - , i I I z"IIoQ Tema: ~~ ~~"'+r" i ~s Aepart qte iollowlne lrttormation td ADEC wttnln 24 aurat3Y FAX (11071189-7508): Gate and time of blaoK smoke everts: From: To: Volume flared which generatetl black smoke (if different from above): MSCF BBLS pescrlption of steps to minimize emissions: See Section B, above. Type of materials burned: Gee: ~NGLs: _ Other: Gen®ral Weather. Air Temperature:; ~^' F Wind Speed/Direction: /VD/'~l' F ~' S'f' Noma and phone number of person making the reporter .,~~,t/1~,~~~- ,~~Or ~~ Name Phone No. Based an infam>zition and belief formed after reasonable Inquiry, I certify that the statent®nts and infomtatian in and attached tb this datxtment are true, accurate and aampleta. Facility Supertri54P ~ -~' ~ ~~~) • e ~ upaamd: FEC BrOR P:~Craups1H5E1'~fmvlronmonttri Hvlp~fomtsl-GO2zti96.>vs 12-06-00 08:22 From-ALPINE NSNR + FLARE taAS VENTING REPORT 'PS ALASKA, INC. • ALPIN~/KUPA PAGfIAilf; Alpine p6veloplnertt ProjeC") i~ERMR Nt3. GAS DI$PQSITION pate o! Occurrence: , f ~s -' 4~ -' dQ ~F~ p ~ (mm/dd/yy) (Check Selection) ~ ~ ~~ From: Total Volume Flared: „tea . ~ F Btil.S From: From: tstcr~i'o:_•.~:•:~ •'~'~ :.•:.•.:•: t3 fai:I ~Piaevira qunplarrrud From: ...... . ... . (Check Seletgon) Front: y-/>~' ,~, ~C.~ ~ ~ From: T-606 P.05/O7 F-66S 0073-ACO49 'fief'te of Occurrence: flQ;QQ ~4;pp Minutes 70~ To: 70: c - 70' __ s Total Minutes Flared: _ / ~ (LiSDaame Orriy - Gds 1ISr19d was Jr011f 0 tgst>saot O Cowrstream (CAeck One) (-nClUaas troturre® flared which gerreratttd black amak6, of T(;G aontaclor m6ter at LPC) if applicable) A, peacription of Incitlent ahd Cause: (Check a5 many as needed w fully describe the Incident) 5-l] TJC# .for Process upset in TIC SD due to high exhaust temperature section of facility Seat oil system diificultieS - ~ -- Flaring for drillsne shutdown / tartup ~- EMERGENCY 3HtJrDOV4N Flare system testing ELI ~ Instrutnernatlon maifuncipn _~ Fauiiy shutdown on _ ' ElecMcal / Instrumema6on malfurtctbn Facility maintenance ~^ dt oMer fadllty (T&G) High ambient terrtpsraturaS. Gas transit system overpressure 5/D on high vibration ~- baoldry CPF/Flow Station out ~_ Other:. r' ~ Excessive /insufficient inlet gas ~' rates into facility f' ~ ~ B_ Action Taken id Eliminate Cause told Prevarrt RecurtonCe: (Check and describe as applicable) staved / re~rted TIC # _ Stabilized facilii~r pnx~ss and oper~tian ~- Compressor / train dapressured Repaired equipmam difficulties Reatxed /increased inlet gas rates r+'~~ _ Gomplated flare testing Facility maintenance oomplett:d Corrected E8.1 fluctuation /failure ~ Other. ~. - Gorreott3d E&I fluctuation !failure r~'~c ~r~ • ~ .~ ~airt~r / at other facility (T8D) -- --- Did incidern cause black smoke? Yes: ~ No: ^ ,~~~ (If Yes, oominue with this sedlon) Did inoiderrt present a poternisl threat to human health or safety? Yes: ^ No: ,~ (If Yes, report to FEG ds soon as possible. ff No, rtrpwt ~ ADEC with 24 hours.) f3lsdt smakr3 emitted from source: L~ ~ 1 d~~ i i P - (entertag number and d~criptiatU Notified ADEC by Fax on: Date: I l /7~/OpyJt_~z~~i I f27 /O d Time: 'S~~' ~r"-''c.~ i ~ ~ Roport tfto following Information to ADEC Within 24)tours6 FAX (f)D7-269.750i~: Data and bme of bleat smoke event: From: Ta: Volume flared which generated bleat smoke (•rf different iron above): M$CF _, BBLS pesodplJon of steps to minimize emissions: See Set:tbn B, above. Type of materials burned: Gas: NGLs: Oflter: Genrirdt Weather: Air Temperature: ~^ F w SpeedlDiraction: I11~ /~ KrSa Name and phone number of person making the repork~ ~/(/l~.~1~^•~ _ •~~O,F~~~ 2~ Name Phone Nq. Based on information and belief formed after reasonable inquiry, I cartlfy that the statements and inl0rmaflon in a~ doarmem are true, accurate a~njd tromp) te. Facility Supervisor ''-fi __ Date _ ~ ~i~~i~d ff tJpdatetl: FEC g~pp P~1tw~oups\HSET1Envirortmental tieiplformsl-t]022a96.~ds 12-08-00 06:22 From-ALPINE NSfdl' + T-6D6 P.04/D7 F-663 FLARE GAS VENTING REPORT Date of tSecurrence: Total Volume Flared: Alpine Development ProjeCl PEkMR NQ. /2, -'~ -' C~G7 - , avant (mrNdd/yy) (Check Selection) '' ~• 7 Ioti MSCF BBiS A11e~rN8:c•:~}:~:~:'~:~''~ '•'•'~ i3 •~C1 ,~Ptamed ^unplaru~ed 'r ~/e ~ ~ ~~, ~ • . (Check Selection) (Llstwrne only - Gass Nanact was from ^ upstream ^ uownsasam (Giecx one! pfTEts' cantacrormererat LPC) From: From: From: From: Flom: From: X073-ACOO9 15me of O.:currence• - To: _ _~~~ To: !~ To: - ,^ To: Iota) Minutes Flart~: _ ~ (ltacludes trohtme flared which generated blaclt smoke, if applk~le) A. Deserlptlon of Incitlont and Cause: (Ct10CK as marry es nestled t0 fully describ9 the InGldent) S1D T/Cl- for T/G SD due ~ high exhaust temperature Beal oil system dlfrlCUlties EMERGENCY SHUTDOWN .,~. t7ertriCal /Instrumentation malfurtctlon Eleotritxl ~ Instrumentaton maik,ncNOn at other facility (TAD) Gas transit sysem overpnfSSUre taaoldne CPF/Fltwr Station art aoceasive ~ insulfiCient inlet gas rates into taaligr B_ Action Taken m Eliminate Cease and Prevene Recurr®nt:e: (Chet:k end descrilto as applicable) Started /restarted 7/C # . ~ Compressor 1 train depressured Redutxd /increased inlet gas rates Completed flaretesting -- Corrected F-Al fluctuation /failure ,_,~~ Corrected E&I fluctuation / failure st other faellhyr (1'&D) Proeass upset In section of facility Fladng for drdlsite shutdown rtup Flare system testing Fauily s)1u~n bt1 ---- Facifity maiment+tu:e High amUient temperatures- SID on h'~~ vibration Other. Ge Titr~as ~/~ i ,' ~ Stabilized fatality p and opsretlon Repaired equipmem diificuldes with Fadllty maintenance ocrnplet tl pther• ~ 53.,)si3. ~ ai ~.•.~ ©sf~ afrsg J Did inoieent cause black smoke? Yes: 6r/ No: "'i 1)~ (lf Yes, oortenus with this sec4on) Did inoid9nt present a potential threat to human health or safety't Yes: O No: J~ (tf Yes, report to FEC as soon as ptassiAle. if No, report to APt=C with 2b hours-) ` Black smoke emitted from source: Lp ~ I ca rat ~ \ ~ _ (enter tag numusr and descripiicn) Notified ADSC by Fax on: Rafe: jJ tt a (~-f TirtiA: --+E~~' ~'~''~"'~ i ~ ~ Report the rollowin9 IrrfomratatM ~ AO~G within 4 hoursBY FAX (807 269.7508): Data and time of black smoke event: From: To: Volume flared which generated black smoke (if differem from above): MSCF BBLS pescrlption of steps to minimize emissions: See Section B, above. Type of materials burned: Gds: ,X NGLs: Otrisr: General Weather. AirTempsrature: Vitind Speed/Direction: o Name and phone number of person making the rsport~~~ ~o,^~Orv'l~ f f ~~ . ~T~f-'t ~`•~'son ~'~~'~"'~ /° ~d ~ 9©~ Name Phone No. Based tan information and belief formeA $tter reasonaoie inquiry, t cErary document ere tru®, aocurats and carrtplete. Facility Supervisor l _,~ FAGItlTY: Date /~~/g~v ~ to tJppaOCa: FEC fYOD P:\6rouPS~}tSET\Erwirotvnsntal MaiA\FOm~s1-04228`-~s ~z-os-oo oe:zz From-ALPINE NStdT FLARE GAS VENTING REPORT PHILLIPS ALASKA,. INC. • At-PINElKUPA Gate of tccurrence: ~,~^"~y i~~ ~'Flam event (mmlddlyy) (Check Selection) Total Volume Flared: ~'~M~+CF _„_BBL~ iNbter ' ~: • 6 •F~H ~Plarv~etl punplan,>ea (Check Selection) ~j7~ 3 moo/ ~ (LisberlJt~E dI1JY ~r'7a3 flared ws5 fran ^ upstr~m ^ downst~9n+ (Check C)rw7 of rFG ranradormeterarLPC) From: From: From: From: From: From: T-608 P.03/OT F-663 .0073-AC009 Time Of Occurrence: To: _ ~._ To: _ To: - To: _ Total Minutes Flarsrl: (!nclrxfes volurtte flared which generated Waclt smoke, ;f appllcaille) A Description ollrfcitl8nt and Ouse: (Chock as many as needed to filly descHbe the incident) SID TICK for Proc®ss upset In _ TIC 5D tlue u nigh exhaust temperature lfies dilF i ~ section aF tacilay Flaring for drdisite ahutrtown startup id: l system Seal n ~^ EMEFiGENGY SFl1JTDOVVN __ Flare System testing Electrical / tnsuumt:maUOn maltunaion _„^_ Fauhy ahutdDwn On ~- Electrical ! lnstrumeMaGOn mslfurxlion Facility malntenarx:a at other tacfllgr (TB,A) High amhisM temperatures. C;as transR syst®m overpressure ~ S!D on high vibration Other..' I>sacing CPF1Ffow Statior- out as nt inlet fliCl E ! i g xCSSSiVe nsu e rates into utility B. Action Taken to Eliminate Cause and Provent Recurrence: (Check antl desorlkae ae applicable) Started /restarted TIC # Stabilized faoiliN proeASS antl operation Compressor /train tlepressured Repaired equipment ditficultree Reduced ~ increased inlet gas rates '"~ Completed flare testing Facility mairrcenanco completed _^ Corrected E$1 fluctuation / failure _,~ ~: ~ ~ '~i^55sin ~^~ Corrected E81 fluctuation ! fEilure ~ rr-, f~'i,r3 i.'n~ at Other facility (T&D) • ~iaok Smoke ~ e.,~er~e..,~e~~.+r,cr- GC?~1CI t'~'1b ~ S Did incidr3nt cause black smoke? Yes: ~ No: ,~:` {It Yes, Dominus with this secction) Dkt incident present d potenasl threat m human hBa1Ct o- safety? Yes: © No:~ (If Yes, report to FECES Soon as possible. ff No, Deport to ADEC with 24 hours.) Slas;lc smoke emitted from source: (enter tag number and descriptioN Notified ADEC by Fax on: Date: Timed R9port rho tollowin9 information ~ ADEC wbhin 24 hoursBY FAIL (9D7-2~69~7S4a): pate and lime of black smoke event: From: To: Volume Bared which generated black smoke (iE giffsrent from above): _,,,_~ MSCF BBLS pescrlpUOn of steps ~ minittwze emissions: See Section B, above. Type of materials bumad: Gas: NGIs: Other: ~ ~o~~,~.~ General weather: Air7emperature:'H5°~ Wln~SpeedlDirecdon: t..6, • ~w-- Name and phone numl>s~ of person making the report: _- - ---- Nttme Phone Nq. tia3eo oil IniOrmaaorl erne ueear i documem are true, accurate and Facility Supervisor FAC1idiY: Alpine i3evelopment Plta~ect PteftMlT No. I certify filet the statements and information in and attached ro pate / ~/ `~ p [~ _~ uppeud: FEC tlrOn P:\6rourrlFta~lErnlronmerltai HelptFom+s\-0Q22B96.xls 12-0~-00 08:22 From-ALPINE NSI~T FARE-GAS V6tVTING REPORT T-608 P.02/OT F-663 FACI).RY: Alpine Development Project PERMR NO. U073-AC009 AS DISPOSITION Date of OCCUITencs: 9 ~~--• ~~ ~~ ~Mxe Ovens Mme tit t~courrenee: (mrNaa/yy) (Check Selection) From: OQ:QO 24tQQ utlnutes To: o Total Volume Flared: ~ ~• ~ M MSCF BBLS From: ~ To: _ From: 70: - ~- •h:Nio'°~::::~:~:~:: •••~•.•..• s• •Fad ~Pianren plfialannetl From: To: _ ~„~ ~ ~, ~ (Check Selection} From: Front: 70: ~, __ To: ~ _ Tatei Minutes Flayed: p_isbunte Onty -Gas flareQ was from ©upstream ^ downsueam (Chedr Ono) Qnctudes volume Bared which generated bIACk Smoke, ce1 TEG conYdrxormeferat L,pCj ~ appllcab-eJ A. Description of InCidant and Cause: (Chock es many ae needed to fully dea~ibe the incident) SJD T/CN for Tre so due to ngn exhaust ten~ps-aa,re ~~-• Seal oil 8ysrem ditliCUltles ~~ - - ^_ f3~lERGENCY 3111.ITDOWN ElecUirxti I irwtrumentatwn matluncrion ~- EIBGUlCa1 / Instrumentation malfunction at other faafiry (r&D) - Gas lrenak system ovetpreseure BSCKinp CpgFlow Station out ~ • - ExaeSSive I Insufflaerx inlet gas raise into facility f3. Action Taken to Eliminate Cause and Prevent tiectMreM.'e: (Ctreck antl describe a$ aPPlicabia) Started /restarted TIC ~ Compressor/train tlepressun:d Reeuoed !increased inlet gas rates Completed flare testing Corrected E&I fluctuation /failure _~_ Corrected FBI fluctuation / fdllure at other fat`.ility (T&D) Process upset in aecuon of testify ~'~ Flarlrxa for drdlsim shutdown ~rt Flora System lestirxi Faulty ehutdoym on Faoitlty maintenance Hiph ambient temperatures. SID on high vibration ~er: • ~ .' Stabilized facility prxdss anti operation Repaired equipment dificulties wnh Facility maifttanance completed tJff-er. BIa,~Gk Srttnke ~~.t ~t~ W ~c~-~t'~c,~-~ tlpr'tic1 t-~"1t~7~ Did incident cause black smoke? Yes: rf No: ^ (If es, cominue with this section) pia incident present a potential threat ~ human heat67 or safety? Yes: D No: (If Yes, report to FEC as soon as posslttle. tf No, report to ADEC with x4 hours.) Blade smoke emittatl from souroe: G •Id ~/N/'G JJ~R 3~p~(e~r tag number and description) NoA7iad ApEC by Faxon: ~; _ Tlms: "~Ceptiit file to'llowlrl~ Ittforriiatfori to ApEC willtln ?+4 hotr-eBY (907.28t)•y6dBk ' Date and time of blade bMOke event: ~ From: „x~~~O~P To: •~'~-'QD ~~~~ Volume flared whk:h generated black smoke (if different from above): _~ MSGF BBLS Description of steps 4D minimize amiss Section B, above. Type of maierlals burned: Gas: NGLs: Other. General Weather: Air stature: ~•~ Wind Speed/PirecYion: ~/~Ar~iitr ~~es.w.~a,~- Name and phone number of person making the report: l~i -Q-yll ~'IV'b~S _ - ~~~"~~"~ Narita Phone No. Based On mTOnnatlOn one tx311Sf torrneu aiiBr tea ,xu»c n~yunY, , vv,.,q .••-• ~•- -••-•~••~~••- -.~ ••..--•------- --- -- tloeumentare true, accurate and complete. Facility Supetvlsor Dam ! ~ ~ (! r to upctat~tl: FEG 8/U0 P:1Graups\HSEf1~rwltarvslenml HelplFomxl-0022$9o.xb 12-07-00 Q7:54 Date at occurrence: Total volume FlateU: From-ALPINE NSMT . _.....~ ...,... ~n r mu n~rt,irt 1 FaCU.RY: Alpine D9velopment Project PERMfr NO. .~~ ~ ~~ gvar,t (mm/ddyyj {Check SelecGOn) MSCF _--,~- BBLS Meter o:: :tat' B~ ~>rac' ~'Plamed ^unWBnned /'+7'R - 3.~0~2 (Check Selection} {tis6ume Onry.: Gas flarop was from O upstream ^ 4oHm,tr~ (Cltatk one) of rEG confacrormeter'att,PCj T-645 P.02/02 F-714 .0073-AC009 Tlnte of occurrences ~~ 24:~ loom From: e/ C c To: _x_^ococ From: ~ Ta: - From: ` 7a: ~ From: To: ~- t `- From: ~- To: - From: To: ~ Totttt Mlnutos Flared: = /11!1 {Includes volume flared which generated bladr 8rrroko, if applicable) A_ DasCripdpn of Incigent and CaGSO: (CheCK as many as needed to fully rrascrlbe the ineldont) SID TJCtr for ~_ TIC Sp due to high exhaust tempereture seal oil system CMfiarl6es ~I_ ~^ ~NIERGENt;Y SfiUTplatMN Electrical / Instrumentation malfunction ~~ ,~_ Faectrical / tnstrumantarion marfr,nctlon "-' at Ottrar fapllry (T6D) _' Cias transit system overpressure ~- bac*ing cPFIFww station out ~~` Fatcessive / insutflcient Inlet gas rates into facilily B. Action Taken to efiminat0 Cartes and Prevent Recurronce: (Check anp describe es appticabloj ,,,_ Slatted J restarted TIC # Compressflr / train tlepressured '"` Reduced ! incraeaeed inlet gas rates _~ Completed flare testing Corrected F~1 fluctuation /failure =~- ,~ Corrected E8d fluctuation /failure at other facility {rB~D) Process upsatin section of facility Flaring for driusite shutdown / Flare system testing Faulty shutdown on _ Faglhy maintenance High amt~ierN temperatures. SID on high vibration Outer: ~.. ~'l~/ ..S'a~'ar~~~~•° Stabilized faciAty process,and operation Repaired equipment diffiouhies with Facility mairroenance completed Oth®r: ,~~'ee. tin i!'orr...:~s.Cn:.. ~ ~ ~ Did ineideM cause blade smoke? Yes: ~„ No: ^ (If Yes, continue wi(h this section) Did inadeM present d poteMidl threat to human heahh or safety? Yes: ^ Iva ~ (If Yes, report to FEC as soon as possible, ff No, report tp ADPC Mirth 24 !tours.) 81adc smoke emitted from source: Lp ~ re rr/riQ 3~~il~ (enter tag number and descriptieon) Notified ApEC by Faxon: Date: lt. ~ oweo,~r ~ Time: '~- L d~ ~Gi Report the following informatlan b AD(:C within 24 houra6v~, 1~ (9p?~g.?Spg); Dare and time of black smoke evens: From: To: volume flared which gensraEed black smoke ('rf different from above): MSCF ggl~ Desenption of steps to minimize emissions: See Src(ion g, at~are. Type of materials homed: Gas: dr•"`" _ NG~: ~@r: Cameral Weather. Air Temperature: Wlnq SpeedJDirection: _ Name and phone dumber of person milking tyre report nil ~M;.~ .~ ~~ ~ w~.~.1 Phone No. teases on lnformadon and belief formed after reasonable inquiry, l certify document are true, aoctrrats and txxnplete. FacNity Supervisor- ~+-~.1, ~ ~ . statements Date / ~"/JQ u upaatost ~c ar00 P: ~GroupatfiSE~'1Envlrorrnentor r+eIP~FOrms1-Oo22590.Ae 12-11-00 13:00 From-ALPINE NShIT + T-826 P.05/05 F-932 FW1RE GAS VENTING REPORT PHIL1_tP$ ALASKA INfC. • ALPINElKI.)PARUK FACILITY: Alpine Development Project PERMIT No. 0073-AC009 nr:e: ~ - CJ yr+ ~~nt O Time Of QCCUrreAC9: Mi CCUrre Date of (ntm/ddlyy) (Check Selection) nuets QQ:aQ 2A:~4 ` From: /O - ,~o e 2 To: ~ Yde = !S+ ~) ~i,,.,~~ L-T".CF S~LS Total volume iFlydt+ed: Z l ~l From: To: _ ~- T - . . . y From; o: anned C7 uti,viarii+ed INt+lerTio:: ~: .: .:vG1:~ S ~fsc ~ From: To: ° ^~ To: _ CAedt Selection) From: Frort: Total Minuets Flared: = (lisiwma fA'tly -Gas tlareQ was from ^ uDStream ^ "' fCnerxc qte) (!ncludeS wlume flared tivh)c)r generated black smoke, of 7EG confacxor meter ar LfaC) )f applleableJ A, pescrtptltm of Incident and Cause: (Check as mamf ~ needed to fully ge5cribe ih0 Irrddent) Process upset In ~~ T!G SD due m nigh exhaust temperature section of feality ~., Seal as system difficultles _, 1~ Flaring for drNlake shutEOwn /~arwR } ~~ Flare system tt:Stir19 EMERGENCY SHUTDOWN .-.---~ _ Faulty shutdown on FJeetrlCal ! InstntmeMation manurwtion Feci+iry maintenance tectricai ! instrumentation matfunctlar- E _ . +^ MI9h ambient Lemperature8. at other facitlry (7&D) S/p on high vibration Gas erattsit systemoverpressure -- ~ Omer: ~ -~ ~ bacirin9 CPF/F-ow Station out --~.- ~ ~ , Excessive /Insufficient inlet 8se .~/~,• /! i'/~ ~'- rates iritofaci~ity B. Action Taken io Eliminate Cause end Provem Recurrence: (Chock and describe as applTcabb) Stabltlzed facility process and operation Started ! restarted 7/C # Compressor! train depreasured Repaired equipment difficulties Reduced !increased inlet gas rates wnh Completetl Hare lasting Facility mairdenance completed ~~ Corrected ESI fluctuation!failure -~- ~®r: `~ ~ ~ ~ max' ' lr~,~¢ ~- Corrected EB~I fluotuatbn !failure -Q~~' ° r '~'~ ° `=~'~'~ at other facility R&p) Did incident cause black smoke? Yss: f~l: No: ^ (If Yes, continue with this section) Aid incident present a potantlal threat to human health or safety? Yes: ^ No: (If Yes, report to FEC a6 soon as ppssibie. ff No, repot to APEC with 24 hours.) Blade smoke emitted from source' il} ~' a.f 4 r'-'17 ~,r$l ~. (enter tag nurTtber and description) Notified ADEC by Faxon: Date: Time: _. Report titd iolloWirrp irRormatlon to ADEC rwithin 24 h~re8 Ax (q07 269'7508): Date and tune of black smoke event: From: To: MSCF BBLS Volume flared which generated black smoke (If differerd fnxn above): --- - Deacrip6on of slaps to minimize emissions: See Sect' ~ aboNVeG.~: Other: TYp+ of materials burned: Gas: _ - Cterterdi Weather. AirTempsrature: ^! Wind Speed/Direction: Name and phone number of person making the report: ~a ~ ' •- Name Based On Inrormaeon ono Drivel IVnilau anc~ ,owv.r..-••••• •••`~••••,• - ------~ document era true, acarrate and complete. Facility Supervtaor ~~u1f rf-~~) Phone too, andand irtfomnation in and attached to Date P:tit7r^vo51tr5Er~~~rnnm~x±±ftd He1P\rc~rms\-QQ2?B"~`~_ws 12-11-00 12:59 From-ALPINE NS~IT + T-9Z6 P.04/05 F-932 FLAKE GA5 V11+NT1NG REPORT pHILUPS ALASKA, INC. • ALPINF~KUPARUK Factunr: Alpine Developmt3rti ProjGCi pERMIi No. dd7S-AC0~9 ~,, - ~-iare ^Vent Tlme of Qcourrenee_ Date of Occurrence: -,~~~yy (Gh®dc Selection) From: D4:114 2444Q Miuutas G To: _ ly~~ Total Yolume Flared: ~.CF Bl3~S From: From: _ To: _-- To: ~_ 1tlIA~rPto:~ ~ B FaC p~ ~'~„ ~unpwmso From= F : ,. .. To: - To: rom 3S'LY (Check Selection) M ~/~' .~ From: _ To; TOtel Minuttas Flaratl: _ ~~ ~~ (fJsDtrme only -Gas Bared -,ras from ^ upsaeam ^ dorms t(,`Aecrc onel (lncludAS volume flared WNkh generated 41ack smok®, of TE~s corltaCtw'meter at tPG) !f applicable) A. Dascrlpiion of InCftlent and Gnu3o: (Check as many as rteedotl to 1u1tY describe the im:id9nt) Process upset in 3!p TIC.b _ f~ ~--~ TIC SD doe to high exhaust tenlperatYfe ~ -- SSCtlOrt of facility Flaring for tlrill9ite shutdown ffinti Seal oil system dif(IicuMies teMERGENCY SFIUTDOWN _ - Flare system testng _ EfectrlCal / Inam,merltation math,nfxwn ~+ Faulty snutdovm on '~- getxriCal / Instrurrtar>tation matlunt:tion Faryiity maintenance at other fedrity (T&D) h11gn ampient temperatures. SID on high vibration Gas transit system overpressure ~ faElter: ~ ~~~ ~`!`8rf(,~dF _ Uac*ing CPF/Flow station out A ~gsiv9 / ir1SlJfdClaM inlet gas te. i r rr ^ Y r `~ - rates into facility .. r ~, s ~ r E:. Action Tarn UD Elimirtatra Cause and PrOYOnt Recurrence: (Check arKl dOSCNtte » appOCabie) STablliZed facility process and operation Started J restarted TIC # _..~- ~- Repaired equipment difficulties Gompressor /train depressured _ ~ ""a' _ Redtirt~tl /increased inlet gas rates Facility maintenance completed Completed flare testing r /f il ~ b '-'~- Qtiler. d. L°dx. ' t}"~- :.-~ e , a u n Corrected fc8~l flut:tuat -- `lam ~'~°~ '°! Corrected E&l flucarafon /failure ! at other facility (1'&D) B1ac~ ~ Did incident cause black smoke? Yes: ~ No: ^ (If Yes, continue with this section) Yes: ~ No: Did incident present a potefltial threat to human health or safety4 (tf Yes, report to FEC as soon as possible. M Nor repor# td AOEC with 24 hours.) ~~' FL~re M71c ~~r1 (enter tag number and deacriprion) Black smoke emitted from source: Time: Notified ApEG by Fax on: Date: RepDR the following irttorrrtatlon m ADEC wittrm 24 haurs6Y FAX (8D7~69.7508): Date and lime of black smoke event: From: __ To: BSLS MSGF ~ black smoke (if tlifferent from above): Volume dared wh~clt generated Description of steps to minimize emissions: See Section B, above. pmerc Type of materials homed: Gas: - 1/ NGLs: _„_ Cat-aral Weather: Air Temperature: Wind Spaed/Directicn; Name and phone number of person making the report '~~^ F• • ~ ^^ rr . ^~ G7a - u~t Name Phttne No. 6638SI On infOmratwn an4 C®IICr Wmtea etnar rwoa+~~www •~w~••~~ • ~+•^•~ document are true. accr,rlate and oo pieta. FacifitY Supervisor statarnents and~inionnation In and Date Upcated: FEC B+pc P:\Gro~Pg1H5ET1EnvlRmmerxa~ tielPtForms~-OUZ?844.x1s ' 12-12=00 19:13 From-ALPINE NS~IT + T-B71 P.02/02 F-990 ~~ pLAR~ GAS VRNTING REPORT •.~~. pHILt•lPS ALASKA INC. • PpUDHQE RAY/GPMAIKUPARUK :':ai'Ds~i1°'res~t-~~' PERMfrNO. ~:~ARI~A'•'•:~~~~~'~ EACf11Tl: Z r ~,~ ~ ^ VCrtt Ti Of 000Urr~nce:- ~~ ~~ Mi 1)ate aT Occurrence: (mmiddlyy) (Cheat Selection) From: 1F1~0 t To: _ ~ BBLS From: ,~~ To: _ ' ~- Total Vptume Flared: ~.L~-~M~F-/~- From: TQ: ,~ _ '"~ ~ftnnnea fa U11P~ned From: To: _ _ ~- r.tio:::.;:< :.;: •-: ;:; ::~~ B •>Fsc (Chi Selection) From: ~- To: - /N T~' ~~~ 1'Z Froth: Ta: ~, ---- Total iM tee Hared: Q dam tc»eck °"•) (rncludes volume flared which generated black smoke, (tishurr+e only -Gas Bared was from Q ups if applicable) of TEG ooratactor meter ar tPCI a. Doscr:Pnon or 1nCident and CatrBa: (Ctteok as many as rteeded to fully cbSCribo the incident) S!D T/Cp ~_ for ~, ~..-~- '~y T!C $D due m nigh exhaust temperature ~r '^'~ $eal oA system ~itttot,lties ~~ EMEtlGENCY SHUTtaOWN -"~"'- ~~ Electrical ! Inr~rumenration ,riayunct-on --~~ ~~ EIeUAGaI ! InsttumerNation maltuttcuon ~~ at other tacir~ty (1'bD) ~~ Gas transit system wgrpressure ~~ pecking GPFfFIoM- Station out f~essNe ~ instaf ficient inlet gas ~~ rat6S into tacifity B. Action Taken ik Etirninate Cause and Prevent gecurrottce: (Check and desfxi6o ae aPPtieabND) Started /restarted TIC a ~^- Compressor /train depressured -• - Reduced / increased 'mist gas rates '^~ Completed flare testlng - ,f-' ~! Carrecfied Ed,l fluctuation / tafiure .-~4~--- ~- Corrected E&{fluctuation !failure ~^ at atl'ier facility Ci'&o) Process upe~ In aAGiOn of reality Flaring for dtinsite shutgown -~ Flare system tsSUng Faulty ahuttlW~+n ~ Facility maintenance high ambient 1amperature9. S-D ~~gh vibration Q/hJgr: , : ~ ~ ~' fY~ i , r~ ' ~~ T - ~ '/ ~; ~' Stabilized facitdy process and operation Repaired equipment difficulties with FaGAty maintenance ~mpleted Oilier: ~ y ~i~r~%dr»~y~ ~: ^ pf Yes, continue with this sectiNo: Did incident cause black smoke? Yea= ~ Yes: ^ pia fnadant present d pOteMiel threat to hu rbie. ~ No. repoKAPEC with 24 hours.) pf Yes, roport to FEC as coon ~ (ernar tag number and description) Black srr-oke emitted from source: lime: Nolpied ApEC by Faxon: ~~: ~ ggg,7r,~; Report the tdtowing iMOrmatlon to ADEC wltltfn 24 houref~-(~' ~,o: Date and time of black smoke event: From: MSCF ~ f36Ls Volume Eldred tiyttictt generated black smvlte (if ditferettt frorrt alcove. ~^~ f7escfiPtion Of GPs to minimize emissions: flee Sectio r NG~s• ~, ~ Other: Type of materiais burned: Gas: Wnd Speedlpirecticn: General Weather. Air Temperature: Name and phone number of person making the repcrl• Ppone Nc. Name • _ -- -_..e....tiwe :.,n,drv. t certify that the statemenw and information in and ached to this Based on irttonnanon ~,~ ~„~, ~~...~-_ -•.--.. __ document are true, accurate and complete. Date f Fdt:Uity guparvisar • ~; EfJC Supen-isor, PRB 6 (flare gas and black smoke inadertts) Field Erntronmantai Compliance Coordinators. PRB 7 (Black smoke incidents 4Ny) PsU/GPMA Feld Mana4ere, (Black smoke incidents only GPMA Oparstiotts Engineerin4 Technical Aide, (GPMA repaRts ony - ATO 477) t(uparuk: Fiatd lttviranmenffiI Compliance Coordinators. NSK 61 (flare Sae and bleat sntake ittcidar-ts) P:\6'rot+pg\HSFr\rxt,rucn:rtentoi Hap\Forms\Flt~re Goy Vt7nlNtig Form BA9•~ UpOat•d: FEC 6104 12-11-00 12:59 From-ALPINE NS~IT + T-826 P.03/05 F-932 FWRE GA$ VENTING REPORT pHILL.IPS ALASKA, INC. + ALPINFJKUPARUK FACILITY: Alpine Development Project PERMIT NO. Q073-ACQt)9 Date of Occurrence: Tota{ Volume Flared: (mm/dd/yy) iCh9ok Selection) ~seF 613LS pleier / s F c~ ~ ~:~ '~1netl O unplanned . ~~IP 3 ~ 4 ~~ (Check S®tectlort) (Llsbume Onry • Gas Nand was irvm ^ upstream ^ uowr+stream fG,e:xc Orel of ~ eorrractormerarat tPC) From= From: From: From: From: From: 75me of t]ccurrencec l]Q;QQ gg;QQ MinuteB ~$Q 70: ~ rien ~ ~/ To: To: _ _ To: - To: - To: ~- _ TOWI Minutes Flared: _ // ~/ d (Induda5 volumtr flared wAiGt generataol black smoke, rf applicable) a. ooscripuon of Incident and Cause: (Check as many ae ~~ zo forty describe the inOidbne) SID T/C# for T/C SD due to high Exhaust tBrtlparature t3eai oil system ctifficukies OuIERGENCY $MLiT00WN Oectricel / InstrumeManOn mam,ncuon Electrical / Instrumentation malfunction r- a! Other tadlity {TikD) Qae transit gygtem overprl9ssure backing CPF/Flew Elation out ~,~' „~ Excessive I insuftitSerlt kuet gas raise into iacilily S. Action Taken to Eliminate Cause and Prevent t;eourrertce: (Cheek and dOShcbo as applicable) Started /restarted TIC # „~_ Compressor / train depressured ~~ REtluoed /increased inlet gas rates Completed flare testing Corrected E&t fluctuation /failure ._ Corrected E&t fluctuation / isilure at other facility (1'8~D) Pnx~ss upset in section Gf facility Flarirl9 for tlrlnslte shutdown artu ` Flare system testing ~-~ Faulty shutctawn on Fadlity malrrcenance High ambient temperatures. SJD on high vibralfon Other. 7 __ ?~ ~ / .~/r~i~7~ vr~ d ~ Stabilized fadtity process and operation Repaired Equipment di(ficultiEs with Facility maintenance completed other. -s'~r ~` G'o ~r_so,,,- Did incident cause black smoke? Yes: §7 No: ^ {It Yes, continue with this section) Did Incldeni present a potential threat to human heaHh ar safely? Yes: ^ No: ~ (If Yes, report to FEC as soon as possible. ff No, report to ADEC with 24 hours.) Black smoke emoted from source: ~ P~~ /YtTf2 3.SP ~~ (enter tag number and description) NotiflEd ADEC py Faxon: Date: Time: - - .--- _-.- _ _ Report rite ronowigg information ~ ADEC wrihin 24 hours BY FAX tso~ z~~tos~: Date and time of bleat smoke evem: Fmm: _ To: volume flared which generated black smoke Crf different from above): ~_ MSGF BeLS I~eacription of steps to minim~e emissions: See Section B, above. Type of materials burned: Gas: 1~`- NGt.s: Other: General Weather. Air Temperature: ~ F/ wnd SpeedlDinscpon: Name and phone number of perm making the report: 3 Rn ~r•'a,rr~ . ~ ~~' ~~1 Name Phane No. Based on information and belief formed aRer reasonable inquiry, I oErtiy that ihE statements ana information in a document are true, accurate and complete. FaoNlty Supervisor , Date upaataa: ft:C WOO R~6roups~ttsEt~erwinonmenra HeiplFOnns~..t7D22ft9gxls 12-11=00 12:59 From-ALPINE NS~IT + T-826 P.02/05 F-932 FLARE GA$ V6NTiNG REPORT Date of Qccurreaae: Total Volume Flared: FAClLI[Y: Alpine DeveEopment PraJecf PERMIT NO. (mmlddlyy) {Check Selection) M5CF BBLS p1e~FNoM~7~y3K ~ ..:~.ac Planned ^unpltutneA ~l%Q 3s'~fa~ (Check Selection) 0073-AG009 3lme eii_aCeumance: j)p;pp 24:01} Minorca From: ~P To: ~ 1f~ _ j~7 From: To: ~_, ~ From: ~ 70: - From: To: a -- From: To: - From: ~_ To: _, - Total Mlntrtes Flared: ¢JsDume aMy -Gas t)area wag fnxrr ^ upstrea+n D aowrutream (G7racx Orw) of rl:G contactor meter at cPC) (Mdudes w~-ums flared whkh yeneraied black smoke, it applicabJeJ A. Doscription e>7 tne:letent and Cause: (Check as marry as rroodod to tulry describe the (rteldent) SrD T/CA for T/C SD duo b high exhaust temperature Seal oll system difficulties E+TtERGENCY SFiIITI~QYVN Elaccical / Instrumentation matrunctitx- Qectrie:al ! Instn+mernaton malfunction at atlter tacphy (T&D) Gas transit system overpressure periling CPF/Row StatioA out Excessive I insufficient inlet gee ~^ rates into facility B. At:tlon Taken to Ellminate Caure and Prevent RcCUrronCe: (Cheek and describe as aPPlirmbte) Started /restarted T/C fi Compressor !train depreasured Reduced /Increased inlet gas rates Completed flare testlng Corrected E.AI fluctuation ~ failure Corrected E&I fluctuation /failure at other faclltty (T&D) Process upsetin section offaalhy Flaring for drillsse shutdown Flare system testing Faulty Shuttlown on Facility maintenance Fllgh ambient temperatures. S/D on high vibra5on tartttsr: S ~~~ f - ~_ r" s' Stabilized fertility prrac.ASS and operation Repaired equipment difficulties with FaplitY maintenance completed Othe~ car ~ : en.Z,o Pitl incitlAM c2lusa black Smoke? Yes: ~ ~ No: D (If YAS, continua wish this section) Rid inadent preeertt a potential threat to human health or safety? Yes: ~ No: (H Yes, report to FEC as sewn ae possible- It N4, repor< ~ APE:C twteh 2d hours.) RIaCk Smoke emitted from source: 1.~ ~/~ s r^t72 3d~~~ (erKer tag number and deacripti4n Notified ADEC by Faxon: Date: Tlme: Report the following Inrormatitxi to ADEC within 24 hocersBY FAX {9D9-~6~9508): Date and time of blade smoke avant From: To: Volume flared which generated black smoke ('rf different from above): MSCF Description of steps to mMimize emissions: See Section 8, above. Type e~f materials burned: Baas: 4'~' IuGls: Other GAnerat Weather. Air Temperature: , `~/ Wind 5peed/Direction: Name and phone number of person making thra report ~~.4n ~ ~ eMe~ • ~ ~ Name Based on intarrAation and pellet rormeo after reasonaoie mqurry, ~ ccrmy dora,ment are true, accurate and complete. Facility Supervisor in Date ~ ~~ ///,r~o } BBI~^^ L'7c - Ydd ~ Phone No. had to-this updates: Fl:C Bd10 ~lcraupslresETl~vlronmanrd NelplFarms~-OD228RS.xr3 12-16-00 09:23 From-ALPINE NSNT + T-005 P.02/03 F-146 FLARE GAS VENTING RRPQRT PHILLIPS ALASKA, INC. • PRUDHOE BAYlGPMA/KUPARUK FACEF.IIY' ~'~i~llpirie:~ni ~}!ig adt~:~: PERMR No. ~;~~.~~~~''':~~' • GAS DISPOSfi'ION +~ .~i Uatn of Occurrence- ~, r ~(.r [~v /Flare Cl verrt Time Oi Occurrerlae_ {mmldd/yy) (Gheclc Selection) 00:00 29:00 ~ From: p3[~p To: ~2:~ _ _./d.a'O, Total Volume Flared: ~~, ~~ art MBCF _^ BBLS From: To: From: To: _ _ ~- Meter~to': 'r F8C" ~ O Planned ~unpmnnec From: ~ ~ • .. • ~ 70: ~- {Check Selection) From: ~~ ` ~~~, J C 6 .955` From: To: ~T TD: M7~' 3 5~0/ ~ L/P. o00 ~ ~ _ Total Minutes Flares: ~/(~7~ Q (tisW,+me orNy -Gas flared was fra» A upstream D dawl-stralm {raecrc ore) (Indudos volume sart~u which generated WaGft smok®, of 7EG contaCrPr meter' at tPCJ if appilaabfe) A. prescription Ot Incident and Cause: (Check aS many a6 needed t0 Fu11Y describe the inclctant) SIp TICS for _ - - Process upset in TrC Sp due m high exhaust ta,npsrature section of facllfty Flaring for drillsite shutdown /startup Seal al system difficulties ^~ ~MERGEWCY SHUTDOWN Flare System testing -~ Electrical / lnstrumerttation malfunction Faulty shutdown on Electrical / Inspumentatian malfurtCdon Faality maintenance at other Facility (f&C) Gas tranaksystem averpreeaure High ambiem temperaturas- S/D on high vibration ~T hacking CPF/Flow Station out Other: fticlent inlet gas F i a / ins ~ecass v u atit t t f y ra es m o a 9. Action Taken pa Eliminide Cause and Prevost Ret:urrance: (Chedi and describe as applicable) Started / restarted T/C # Stablllzed facility process antl operation Compressor / train tlapressured _~~ Rapairetl equipment diificultiea ~ Reduces 1 tnaeased inlet gas rates ,Mth r~Y ~' ~ r. Completed flare testing Fadlity maintenance completed Corrected E8,1 fluctua5ort /failure tamer: -'^ Correctetl E&I fluctuatlpn / failure st outer taoility (T&D) Black Smoke Did incident cause black smoke? Yea: D No: ~., (If Yee, ccfliinue with this section) ? Yes: D No: fel h lth y ea or sa pid incident present a potential threat 14 human (tf Yes, report to FEC as soon as Possible. tt No, report tv ADEC with 24 bouts) Biadt smoke ertitted from source: (enter tat; number and description) Notifiatl ADEC by Fax on: Date: Tune: Report the tollowirrg lrgorraation to ADEC Whhin 24 hours,BY FAx (907 2897508): Pam ens time of black smoke event: From: -- To: M SCF BBLS Volume flares whlch generated black smoke (it different #rom above}; pescription of steps to minimize emissions: See Sectiarr S, above. Type of ntatertals burned: Gas: NGLS: ~~ Other: General Weather. Air7emperature: Wintl SpeedlDirectian: Name one phone number cf person making the report: . Name sasAe on mtomtatH document are true, Facility Supervisor the pate ~~-~~ r~~ Phone No. rx: EtaC Supervisor, PRB 6 (flare gas and blade smoke incidents) Feld Environmental Compliance Coordinators. PRB 7 (Black Smoke incidents onN) PBU/GPMA Field MaFlagere, {Black smoke ineisente only) GPMA Operations Engin®ering Technical Aide. (GPMA reports only - ATO 477) Kuparuk: Field Environmental Compliance Coortlinator3, NSK B1 {fare gas and black arnaka incidents) UptlA~ FEX: sroo P:\6roupslN5kTlFJwirorlmantol Help\FolrnilFiGre Gos Vetmnp Form 8-08.ws 12-16-00 09:24 Date of Ocourrertoe: Total Votutste Flared: From-ALPINE NStu1T + T-005 P.03/03 F-146 FLARE GAS VEN77NG REPORT PttILLIPS ALASKA, INC. • PRUDHOE BAY/GPMA/KUPARUK PACILRY: •:~fclGdrie:#7~r~ro)eU::~: PERMIT MC. _:~ON.3~AC004':~:~':'~'~'• GAS DISPOSI7lON x-13~~-r~o JB~Flare ^vent (mm/dd/yy} (Check Selection) ~'S I~IMSCF BBLS Time of dccurrence• pQ;pp 24;QQ AAinutes From: ~~ - To: s From: :6 To: ~+V:3Z = ~~r--- From: To: = From: To: _ __ _ __ From: 70: From: To: _ Total Minutes Flarmtl: - (1ncJuQles volum® Aered which gerterdted bk3ok Srftoke, !/applicable) r:Ffo~.;.;•••:•.;.•.•:.•.•.•:• 13 t=ie Oalanned ~[t)nvlenned :.. ....... ...... w~. 'tt3sa~r (Check Selecborl) ft-islsume Onry - C,as f!a-ad was from ^ upsveam ^ Qawnsveam fCnoa~ Cne! of TEG confat7tx rooter ar LPC) A Description of Incident and Causo: (Chtftr>t tie rnanv as needed to fully deeorlbe The incident) ~_ S/DTlCe Q-38elir for Ni If.5+ew1-..l T/C SD clue to nigh exhaust temperature Seat oil system dtniculties EMERGENCY SHIJTDC3YVN Eilet~fical! In3inimetNation malfunction Electi'ic21 / Insfrumerttation nlttlfunction at other facility (Tao} Gas transh system overpres3ura backing CPFlFbw Station out Exicessive / inauffx:ierrt inlet pas rates into facility B. Action Tarn m Eliminate Canso antl P nr Racurtence: (ChoeK and describe es applicable) Stalled / eSTarted !C # ~ - `fib! ~„~_ __ Compressor train depressured Reduced /increased IMet gas rates Completed flare testing ,~ Corrected FSl fluctuation /failure Corrected EP,I fluotuation /failure dt oflter fatality (f'd~D} Process uD~ in section 01 fadllty Flaring for dfiilrate Shutdown / SlaRltp Ftar® system tasting FauKy ShutrJOwn on Fadilty mairrtenartca Hi~1 amWent temperatU-es- S/D on high vibration vtner. Stabilized facility process and operation Repaired equipment difficulties with Faality maintenance completed tJttler: Ditl Incident cause black smoKa? Yes: ~. No: IeT (If Yes, continue with this section) Did inoitlaM present a potential thtaat fC human health or safes Yes: ^ N0: {If Yes, report to FEC as arson as possible. M No, report to ADEC with 24 hours.) BIaCk smoke ®mitted from s0un.e: (enter tag number and description) Notified ADEC fay Fax on: Rafe: Time: - Repoli ttte fo114wing infomHtion tD ADF.C within 24 hourS,BY FA,x (9p7~69-7506): Date and time of black smoke event: From: Ta: Volume flared which generated black smoke (if differfent from above): MSCF BBLS Desoeptlon of steps to minimise ltmissions: See Section B, above. Type of materials twined: bias: NG W: Other: General Weather: Alr Temperature: Wind SpraadlDlrec6on: Name and phone number of person making the report: Name Phone No. Based on infonnatlon env belief fomlrsd after reasonable inquiry,) eeroty that the statements and infom;tatlon in and attached to dooument era tru9. accurate and c0 plc Facility Supervisor -'^` Qate ! cc: EOC Supervisor. PRB fi (flare gas antl black smoke incidents) Rsld Environmental Compliance Coordinators, PRB 7 (Black Smoke incidents only) PBU/GPMA Field Managers, (t3lack smoke intodents tiny) rPMA t~n~,ret;onr.• Englnearinq Technical AiBA, (GPMA reports only - ATb a7n 12-23=00 12:11 From-ALPINE NSNR + T-177 P.02I05 F-361 r~s~n~ tiarw •~n nma n~rvn~ .~. FacurrY: ~F~~~~ ~.. g.~4~ M~ err no. :a'~s~~'~' :.:.:~3~! - --~ -- t~ of ac~nrence: 1 ~.. l o n v~ m (check Selectlcn) From: Total Yoltrerts Flared= ~-~ M$G~F 1381.5 W{et~>F1os: d riarKrad O Uraarr~ed (Check Sermon) From: Frorre Fnari: From: ~~ i~ e ~ ~f '" Ta 15:1 S Ta To: Ta - -~ - Total lWrartes Flared: _ ~6~ Q {Lfsbui»a Only-Gas dareQ was ~ ~ ~a ~ dor+rt l~l~ ~ a4 Tt=G cnn(ac~iratatsret LPC) {Hx*J~lS M~4MNr19 flared whlClf pkl/19eYlF9d blkiCk St1>17~V9, l~epp><icad+al A Deacrip~n of ineldaetwrKl Catrsa: (Cheek asmare/ ~ rrerrrMrA t,o fuy dascrWe the Irwida~eq sIp Tlt:s tOt Process in TIC SD dos to tliyh aodreust larnperature aeeYan ottarality ~- ~ oN syatare dd6arlfies Flaring for driMoiea ahuldorm ! searlup '~- EJI1f=RC~Nl:1f SHtJT1101AR~1 F1ara sy~ taatirrp ~- EloetriceA l lr~ranr~tamon rrratsmetiort ~_ F~ afw,mown ~ ~~ E5ec6~feat ! k»rtarrenk~an I~~~art Fea~l mairrlarranos ~- ad ogerie~dib (1.8DI --•--~ ~ ~ p L3as trartoit alraMm aMerpres9ure ~- ~ oa high vbration Other: - lA as t~ ~ ~ ~ ~C1 U bsddng CPF1Row Sia~l out , . w ~. n Ewe ~ iosulidane inlet gas ~ _C.t] i ~ ~ ~^ t• u mesa irrb i~aoiiltr Acton Taha to ENa+inats C~uao anrJ Prevent Rearnrroe: (Ctrrok awm aucribtt as appprawa) B . Started / nsslarted TJ~C i 5tebilinad fear proosss a~ oper8tiop Canpreaear / pain depressurad ~~'~ d>lficttties Redrtaed / int~esaed krlet gas roles tl~ FacNfty tt~nmenartoe cxnrtpie0ed ~ -"~i Corrected €81 flueY,ation / fsiu~A ~_ ,,,, e:~tter: ~ ~'~ Canaolod E8d f111dU24iar1 I faiure ~T 6d Qlher faddy ('f8D) pid inoldard cartes blade txrtoke7 Yes: D No: ~ ~ (tf Yes. ~ wtlh th"s seoUon) • ~ Did incident prttsertt a P ttKaal to hunsn itesth or sefetyt (I(Yes. ropart m ~ as soon as poasgtle. IE ~ report to A~ vrlgt ~ ~u~-) Blerdr amolaj entitled front aottrca (~e1' ~ r"'rr~ arrd ~r~10n} Natgled ADEC by Fax err l7aba T+~ et.port ur• fo~arrrktg talon to M7~C ,rIMYa gil lrsra. @~ (ttg7~ss•'i~OBk pate and tiros d blade smdte e>+~ PDatt: To: vowme Herod which generated black amat®Cf diF~ererd from ttbot~: _..~, tdt# •-.-- pescripticrt d to mptindaa ernlsabns: 8es Section 8. atwva. Type d marerias bunted: Ces: P1Cits: _ Outer: Gerrerat We~ethee Ak Temper~ae: ~-, ~1N'nd speedJDireetiar• Name and ptto-re ntlnther d pttnsati malo,tg ttte report: IVerrte Rhone No. t355ei0 an Inromrawn artu wool ~ doctenent se true. e~oratrete ~d Fa~gl 8upawhor p.. Z / a-a oa SOC Sttperrisar, PRB 6 (flweai blstAC sdtoks Irtciderrts) Field ErlMknnrrterdtd t.omp • Cesrdnabats, PRB 7 (t318dt Smdcts irxti0enle orttyr) PBU/GF'AAA Field MprragArs, {Black tilnolte IltCitlerlt8 only) GP1iAA Oparatior-e Sn9fnaerir~ Tednicat Aide, (GPMA rrlpcrts aNy - ATO 4TH Kupartrlc Field Ernianmerttet C~ampNant:+e Goonditaats, NtaK Q1(flar+a gab end Mack timoloe incideMtts) 12-23'-00 12:11 From-ALPINE NSf~IT + T-177 P.03/05 F-361 FLARE QAS VENTNC' REPt]RT PHIL.L.IPS ALAS INC. • PRUDHOE B~AYJGPINMKUPARUK FwCMY: ~:-~-~~tl~lr~l'K~N`~ F~wr~riNO. ~:~'-_~.~.-,aF~',`:'•' f~~^ Date Q~ OCCIIrratM79: Z. ~ d O ©~ ~1-ellt mmlddl~l (Check SdeC~ioil) Tart~d Vdlrrrn~ ~isnsd: ~~ rIASCF ~BBLS, If~+~mriN(o: '• ©awmeu O tanned (Check S~efectbn) {t.-ebinr~e Orb'- t~sa i~ia4 was ~ ~ le6belRn ~ dews~aem t of 7€G oanlrcrprlllewatLPq 'thrw of i1~ ~i4.'i~l FrwlK r~ oa Ta Z ~ ~ ~b From: . Ta ~ _ FrRxrl: ~„ Ta ^- _ Frame ~~„_ Ta From: Trx ~_._-'. FrorrK ~ Ta Toot itnnllMes f ~' ~e (1rx'~idss rakne l~d~d perrarated [deck srrs+laeR ^appir~b) J+, On OE blCrdellt alld glif+~ (CIMak o tRfa~ A a~edud ~ ~~ d~ran 1!M hlSiAel~q ~ T~ ~ Ffiooe~a `~~ ~ •~^~~ ~- TJiC SD duab high e~dttimpasdKe laC1i011 of f~iq- -~ Seel all ~a~ dilRulliea 1,,,,,_ Flelin0 ~' drWriM ^hlldown ! ater4Q ~~ EIYIFRC~IGYSIiU'TDW1M F1~eeo-slxaia~n0 ~- Ela~icd liwdnrmanlu~ion+noifur~lion Fe~4- atxlteAowl °^ ~~ ElecbicN Nneslmlenmron malllRwilon Few '-"! at eQ~erTadrlq- (rd~D} ambient s " i?se iranea syeirie ~1p~ ~^ on an ~ ~ ~~ ineuaialardidetpss ~~ ~ ~ ~ ~ -Z~~ V -~- laeee inb fB-~Yp- Acrion'i7eaea b ~ba6lab aloe and Prwawt fiaawlwlee: (~dl aad desatibe ae aPP) B , lestarled TIC -~^ StBbiar~ed fa~a41- proossa and aperaAbn ~. S ~ RepaTrsd egtdplr~f da>faraies ~ --"'- RedtlGed / itlCreaaOd k~iat 9YS r~ss ~ ~^p Facifgr lrlairMenallGe ~- ~gnec~ed E.~I fl11e~1a1i0r1 ! hllkMS filer. -~. Corroded F~1 iirlcilldiolt f Tailors -~- at atller taciAq~ lT~? pid klGlderit ~ bisd~ smrtoloeT ~ Yea: O Nac 1~ (rr Yes, as ~~e wan ttds ^ediart) did ilrciderrt P a tad tltreat to human NssRh Q adngfd {KY+~4 ~~ ~ FiEar of snort as pasalWs. if Mo. rsportlo 11bLC wNh Z41~re.) f3mcic snlolre eodiled from sauncec I Tenter roB "'R'+t'er acrd de°m(pd°") Walifled AE>EC by Fes arK Dales T~ _~ Rap~are ~ NdelnMton m ADEC rrltllln ~441MOtlrs ~~ (ii0T~9-70iM~ Dwie and aims d bmdi smoMS ~ imdcs (r r~errt fiam aborek Ta T- Valtne blared wltkdi gsmralsd neecrlpuat cl seeps a mininrme emissions: s~ sectlsn e. a~ . c~ae: WGLa. w~ ~ Wadnerbtsrie~ ATr Tanperagssc I~fane arld r1Yll~er d penal maWnp Ura report: fY~lla N~ 8aee11 all aIIORllaoan e~ owo~ ~ dOFlarAerlt eta Iltla. ~~ arld D~~~~ ca EOC Sepe~rvlsor. PIS t3 f~ oCk etr141re ilCiderd's) Field F.rridrnr.nelllal ~. F+RB 7 (Bleak Snloecs M+ddelda anb/j PBLKoPiIAA F'feed , (~~ anlolas YlCid6llea Crdy~ CsPIMA Operseidt'rs Exrplrteerlrrp TeWtr+feal Aids, (6P#A~- rolrr++m +anhi ` AT+D 4T7) KapartrlC Field Ernilarrrlenlel t'rampfiarw~a Goolrorlators. hISIC 6i tiirare pas end black smd~ inddenls} 12-23=00 12:12 From-ALPINE NSf~IT + T-177 P.04/05 F-361 FLARE C~-8 VENTING REPORT ~SKA. INC. • RRUDHOE BAYl~liAMCUPA~,UK l FAgLrIY: ~.~~'~hl~•:~i1~~1°~1~~ ptsRMiTN(?. :~~3d~=~:-:~~~:~: ire of Ocgrrrer» ~ ~ ~ ~] 0 Q rem ~~ (Check Selection) Ta#ai Vofwwnelcianed: ~.-`j ~ MBCF l3B~F •:.•:.•.•:: •:.. ...... {Cfieck Selection) ~(.lsLrpne Orel!"- Caen oared was iFwt- ~ ~• Q dorrrrmnsrr ( Ong ol7EC3 t~ornre(aratt,PC:) Tbne of Oocunenee: From: ~~ `.1 ~ Ta :3 0 = _ b+t ~ _ - - From: Ta ~ - t=rarc Ta -- From: Ta: _ ~ _ Frain .~. Ta ~ - - - - - . 1=rorrK Ta = TOtel >Yfimses Fhusd: ~ ~`~'".,5~ (MCk~dei rolrarre t7ersdwl~i gieneralsdbiaCk SfllOkid, Sappfceb~) A, ~ rf incidsnt and Csuee: (Check ss nrsrti- ra rraeded to ttr~- describe Lila lncidenel S1D Tlt~ tOr ~~, 'flt3 SQ dueleiygri aoasus<ternperadrs -- Sad oa syleelrl d(~icul6ea ~... ~- FJItBiGENC1f SFitlTDOYVM ~„_,.^ ~- Electrical / Jheentaeon nrerfEmc6on ~- Electrical / Inatnarrenwtion mdiErr+~~ ,r_ ~~ at otlrer EsdM4r RaD) ~-- ces tit ~ asrrpressurs ~ backing t.'FF1Row ikon out -~-- t3saeshre ~ Mmuifideru irriet ~ ~~~ B, Action Tsken m EiNdneis Cwse and Prvane Rtrp.rerro~ IChrct ono dbe as appNraaa) Sysited / restarted Tl~C +« i~ Corrrprsssar / trdn depne~ssunbd 1..,,-..-_ _ Reduced / inerea~ed inlet yeo nitee ----- caenua,~t~lias ~ -~ yea r~sr ti,auaGon /tailiars ""-' Notherfaolth-R~ Procase rrpset in eectlan ~rtilry'~r Hering for drSeite ahtAdorrr- / ater0lp Here ayetem tasting l:aulgl on Fedligt ~ Mi9h ambient eanparaeaes.on hipir t~ration on,er. ~ N 4 ~. l W~ stud tardy process and aperatim Re~p~+e0 equlPmern ~ Fara7dy nrakrpansnoe completed otner_ s ~.. ~ t., i,~,,. ~ tbd irtcider# case k+tedc smdm4 Yes: C? No: I~ (It Yee. ctrMkxre with this section) Dld incident present a pderaial throat to human hedth ar sd?egA' Yes: D IVo: ~ (If Ys. r19114r't m FEC:w iCiOrt as poeelbN. li qO. IwAor! ~ I-oEC wNh ~t hoaws.) Btacit smolae anrRled from earrrre: (er-ter tag acrd deecrlpNon) NatTied ADS !~- Fax an: Data; Time: tiapori ttrs ioaowtrrg krrarrstiou to AD1E~.rittl~e u hours $Y r-UI l'Y07,~•76D1t~ Date and iirrte of btacie smoke aMerrl: t=-~ortX Ta . , Valtane tierod wFrich 9snalated black smells Qf tlilfsrent from d~we): 11ASCF t3BL5 pesp~rtian of steps to ruNrlmtxe enNsslorre: Sas Section B. ahc~n. .type a maaeri~ burned: cis: wrLs: ,_ oti>er: tener~ py~~ /ur Temperature:. vvtr~ ~~ Hla,rre and phone number ai parson metaria<a ttre report ~ ~ $aied tin trrtCfm8Mlf7rr sna pq•er ~nw~ cacao iw~wsna nMw7. ~ ,.awl w~ca wp.r•~•••••••••- -••- ••••~•••••••.-•• __ -.., _.... dp~rerrt als irNB, alyd OO 1 „~ Deoe 17 C) ~' ct~ EOC SerparMecr. PRB 6 (flans srd e{ack srrrdes lnciderrts) Field Enviramrarld ~~ i'RR 7 (Block Smoke incidents onlyl) PBUUCaP6AA f=ield Yano®ers. (E31adc attroloa incidents ~ GPM/14peralbna F.~earing 7achricd Aide, (OPMA isryaits aMY - ATiD 4'Tn FLARE GAS VENTING REPORT PHILLIPS ALASKA, INC. • PRUDHOE BAY/GPMA/KUPARUK FACILITY: ~>:~Alpioe:f)erv;a~iojecf:: PERMR NO. :~: >ODT.3=ACQ09:~::~:~;> GAS DISPOSITION Date of Occurrence• ~~ ~~ ~ ~~ ~8(Fiare ^vent Time of Occurrence: (mMdd/yy) (Check Selection) 00:00 24:00 Minutes / From: ~ To: /(o%$ _ ~Z S Total Volume Flared: ~(~ •~ MMSCF BBLS From: ~[~ To: ~ _ ~~ From: To: _ IdlBi@I'NO:[::::::~:~:::~:~:~:~:: B FBCilit ^Planned 'Unplanned From: To: _ /~ 3~f~ ~ 2 (Check Selection) From: To: _ M7 From: Ta = Total Minutes Flared: = g~~ (Listwme Only -Gas flared was from ^ upstream ^ downstream (Check One) (Includes volume flared which generated black smoke, of TEG contactor meter at LPC) if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) SID T/C# for ~ Process upset in T~~ T/C SD due to high exhaust temperature section of facility Seal oil system difficulties Flaring for drillsite shutdown /startup EMERGENCY SHUTDOWN Flare system testing Electrical /Instrumentation malfunction Faulty shutdown on Electrical /Instrumentation malfunction Facility maintenance at other facility (T&D) High ambient temperatures. Gas transit system overpressure S/D on high vibration backing CPF/Flow Station out Other. Excessive /insufficient inlet gas rates into facility B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started /restarted T/C # ~~ ..Stabilized facility process and operation Compressor /train depressured Repaired equipment difficulties Reduced /increased inlet gas rates with Completed flare testing Facility maintenance completed Corrected E&I fluctuation /failure Other. Corrected E&I fluctuation /failure at other facility R&D) Black Smoke Did incident cause black smoke? Yes: ~ No: ^ (If Yes, continue with this section) Did incident present a potential threat to human health or safety? Yes: ^ No: ^ (If Yes, report to FEC as soon as possible. if No, report to ADEC with 24 hours.) Black smoke emitted from source: (enter tag number and description) Notified ADEC by Fax on: Date: Time: Report the following information to ADEC within 24 hoursBY FAX (907-269-7508): Date and time of black smoke event: From: To: Volume flared which generated black smoke (if different from above): MSCF BBLS Description of steps to minimize emissions: See Section B, above. Type of materials burned: Gas: NGLs: Other: General Weather. Air Temperature: Wind Speed/Direction: Name and phone number of person making the report: Name Phone No. Based on information and belief formed after reasonable inquiry, I certiiy that the statements and information in and attached to this document are true, accurate co lete. Facility Supervisor ~ ~ Date ~ ~ ~~ co: EOC Supervisor, PRB 6 (flare gas and black smoke incidents) Field Environmental Compliance Coordinators, PRB 7 (Black Smoke incidents only) PBU/GPMA Field Managers, (Black smoke incidents only) GPMA Operations Engineering Technical Aide, (GPMA reports only - ATO 477) Kuparuk: Field Environmental Compliance Coordinators, NSK 61 (flare gas and black smoke incidents) Updated: FEC 6/00 P:\Groups\HSET\Environmental Help\Farrns\Flare Gas Venting Form 8-98.x1s FLARE GAS VENTING REPORT PHILLIPS ALASKA, INC. • PRUDHOE BAY/GPMA/KUPARUK FACILITY: >:~Alpitiea~e~t::~roieof:: PERMRNO. :~>:~OQ7.3=A0009::~:~:~:~:~ GAS DISPOSITION Date of Occurrence: ~Z w ~~ ^Flare ^vent Time of Occurrence: (mm/dd/yy) (Check Selection) 00:~ Minutes From: d ~f 3 7 To: !A~ _ ~L Total Volume. Flared: ~~ • ~ M MSCF BBLS From: Tae = From: To: MiEaer:NOa>:~:~>:~::~:~::::::~: B~ ~1?acilitiy ::::~:: armed ,l~nplanned From: To: _ p (Check Selection) From: To: _ MTr1 ' .3SO~Z From: Ta _ Q Total Minutes Flared: _ / ~~ (Llsbume Only- Gas Nared was from ^ upstream ^ downstream (cneck one) (Includes volume flared which generated black smoke; of TEG contactor meter at LPC) if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) S/D T/C# for ~_ Process upset in /~/ /~%,r~'y g ~~jAi ~~d T/C SD due to high exhaust temperature section of facility Seal oil system difficulties Flaring for drillsite shutdown /startup x EMERGENCY SHUTDOWN Flare system testing X Electrical /Instrumentation malfunctiort~~ Qi'ai/r`r-~ ~ Faulty shutdown on Electrical /Instrumentation malfunction -~`- Facility maintenance at other facility (T&D) High ambient temperatures. Gas transit system overpressure S/D on high vibration backing CPF/Flow Station out Other. Excessive /insufficient inlet gas rates into facility B. Action Taken to Eliminate Cause and Prevent Recurrence: {Check and describe as applicable) Started /restarted T/C # Stabilized facility process and operation Compressor / .train depressured ~ Repaired equipment diffic rlties Reduced /increased inlet gas rates with GPt~ /~/ rIf ~ Xr itc, /iMei~ Ir/d Completed flare testing Facility maintenance c mpleted Corrected E&I fluctuation /failure Other. . Corrected E&I fluctuation /failure at other faciliiy R&D) Black Smoke Did incident cause black smoke? Yes: ~ No: ^ (If Yes, continue with this section) Did incident present a potential threat to human healttYor safety? Yes: ^ No: ^ (If Yes, report to FEC as soon as possible. If No, report to ADEC with 24 hours.) Black smoke emitted from source: (enter tag number and description) Notified ADEC by Fax on: Date: Time: Report the following information to ADEC within 24 hoursBY FAX (907-269-7508): Date and time of black smoke event: From: To: Volume flared which generated black smoke (if different from above): MSCF BBLS Description of steps to minimize emissions: See Section B, above. Type of materials burned: Gas: NGLs: Other: General Weather: Air Temperature: Wind Speed/Direction: Name and phone number of person making the report: Name Phone No. Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurst plete. ~~ Facility Supervisor ~~~i 1 Date ~ Z cc: EOC Supervisor, PRB 6 (flare gas and black smoke incidents) Field Environmental Compliance Coordinators, PRB 7 (Black Smoke incidents only) PBU/GPMA Field Managers, (Black smoke incidents only) GPMA Operations Engineering Ter~nical Aide, (GPMA reports only - ATO 477) Kuparuk: Field Environmental Compliance Coordinators, NSK 61 (flare gas and black smoke incidents) Updated: FEC 8/00 P:\Groups\HSE7\Environmental Help\Fonns\Flare Gas Venting Form 8-98.x1s 12-25-00 12:12 Date of octxrrrenee: From-ALPINE NSfAT FACifffY: FLARE GAS VENTING REPORT ,SKA. INC. • PRUDHOE BAY/GPI ~::hlpdiia i>~ait. ~h ~: ~: ~~ ~Z~dt3 t~~ o~ (~~YY) (Check Selection) Total Volume Flared: MSQF BBLS M'~(p;=~ ~ ,aC ©PSerarr ~10A P~ (Check Selection) (~ig6ryrts carNy - Gas !lerBd rtes Iront D upmeare Q dormstrearn f~ one) W 7~C; aor~cror meter arlPO) PEItMR NO. From: From: From: from: T-177 P.05/05 F-361 ~: ~OQT~.4G110~:;-:- Ttma of Occurronca• 29~Q . f¢ 3'S' To: d'"D = 7 sue' __.__- To: - -- ~^ To: - _ To: - Total Minuets Flared: = ~ ~ (Irrdudes vvkrrne Rated whkh gener$tad b1,sdVc srratta, 1~ app!lcabfe) A. pttsrxlptlon of Irrddant and Cauae: (cttodc as many as nearJod to fidhr describe tae Incident) ~ AS ~~ '" S-o 71G- for. ~- j Process upsettn ? Tlir SD due b hlph extrauet temperature ~~ Seal oil 6yetent tlitTidlaGes ~ ~ ~ Shutdown /startup ~9 ~+ F~+IF.RGfB+iCY 3fi1.1T0t3fNN -- ~~ ~~ ~~ t7echical I In~rwnerNalion malfuno>ion Faulty eF~utdown wr - E-7eetrical / Inrpru~nerMatan matnmWon - Faality matnter~anae ~~ at other tacAby (T&i~) Biel' amhierrt temperawrea pastransit system overpressure ~ SJD 4n high vibration hearths CPFfROw Station out Other: E:rGeeeive / irreutfirient irrat gas ~ rates irlso facility ~ B. Action Taken to EllrirlfistR cruse and Prevent Recurrerroa: {Checlt antl Oeacribe as applicable) Started / r98ta~d T/C B Stabilized facility process and operatbh _~ Compreaaor /train depreseured ~ Repaired equipment difflatltles Redtx~J / inrxeased Inlet gas rates ~1h ~7 A5 "r2.41~ '~~ t'.omplated flats testing !„^ Facility maintenance completed t,`,pr(eUed t.~t flutRttation / failure ~~ Corrected F&1 flucwatlon / (allure '^~ rt other fecAity (TSD) Did irKadertt cause bleak smoke? Yas: .: No: (If Yes, continue vraAt- this section) ~ ktciderd present a potential tFtreffi 1D human health w Satiety? Yes: ^ No: B'~ (If Yes, report t0 pEC as 901 as possible. ff tile, nspat to ADEC umft ~ hours.) Black errloka emitted from source: (enter tag number aitd description) Notlfled ADEC by Fax an: Date• -- -- -- 'rte' Report the follOYrirtp information to ADEC witttln 24 houraBY FAX (~7 ?L~7506): . Date and time of black tttnoka evsrtt: Frarr-: ~ To: Zit =~ 77 -- Volume flared vrhich genereted Wadc smoke (ff different from above): MSCF ~ BBL3 pptlnn of steps to minimize errlisSbrrS: See t3ectlon B, share. Type of tnaterialG burned: Gas: t~ _ Nfa'I..s' Qther: General Weather. Air TemperAture: rPl' wn0 SpeedlDirection: Name end phone number of person malting the report: ~~ Pttcne No. I3aSed on infomlation and trelief icrmad after reasonable inquiry. i Certify tftat the staterrtents ana Ntparmtm4ri m tura a~rneu to ms document are true, accurate and complete. Facility Supervisor • Pate ~ ~~~1 tx: HOC SupttiviscP, RB B (flare gas and black smoke inoider+ts) Feb Emironmentai Comptiattos Cccrctirrattors. PRB 7 (Black Smoke Incidents only) Pt3t!/GPMA Field fiAana®er~, (Bieck smoke incidents tufty) GPMA Operations Engineering Technical Aida, (GPMA n',po~ only - AT4 47'7) Kuptwk: Field Emrironmantel t:omptiance Coordinators, Nt3K 61 (flare pas and bku~ smoke irxaderrts) V uppnped: FEC ttroD P.~Gro~s1-SEnEnvlnxmenra Hmip\romu~RareCcrve~nlinp Fonr+E-98.xk 01-11~-01 07:50 From-ALPINE NSI~T + T-80Z P.02/02 F-ZZ4 PHiti_tPS AUISKA, tNC. • PRUDHOE BAY/1'.wPMA/KtJpARUK FACl1J1Y: ~:~AIp)[ies<;;.Ptoteo>t~>: PERMiT NO. ~:~00,73~AC4QR~'~:•'~:~.~:~ ' GAS piSPOSITION Date of t7ceurrence: / ~ ~ 3 ~ Flare Deem Time of Occurrence: (mnVa yy) (Gheck Selection) QQ;Qp 29:QD From: To: U ~?~ _ _~~~ Total Volume Flared: ~ . 3 MSCF BBL3 Fro:Y-: _ _ _ To: _ From: To: Meter7to:C~. •' B' ~f~c ^PlarMetl ~JUr:plamed Frgm: _~_ To: - '~ ~. (Check Selection) From: ~_ Ta: o From: 70: 5 . Total Mtnutos Flarotl: ~ c Ca {1_isbuma Onty -Gas fished was frorrl ^ upstream ~ aownstream {l7frecw One) {includes vo1L+m8 Rd/ed v-diiClr generated black sMOke, of rEG contactor meter at tP~C) i- apprcable) A. i]eecription of Incldem and Cause: (Chock as many as needed to fully describe the Incident) S!D T/C# for Process upset in T!C 8t7 Oue to high exhaust temperature ~ section at facility Seal ai system difficulties ~_ Flaring for dritlafte enutpown! stanvp EMERGEWCY SHUTDOWN ^~ Frare system testing Electrical I Instrumentatwn mam,nctior- ~,_ Faulty stwttlown on ©Br:trlCal / InstrufieMatiOn malfunction ~^ Facility maintenance at other facility (T&D) Fligh ameieM temperatures. __ _ __ _ .Gas transit system overpressure SID +mrhigh vibration backing CPF/Flow Station out Other: ~ rr . f"' Cr ~/ Excessive I Insufficient inlet gee p//+ff s't` ~ «- tates irroafacility _ 8. Action Taken to Esmittate Cause and Prevent Recwrerwre: (Cheek and cleseribe as applkable) Started / restanea T!C ~ Stabilized facility process and operation Compressor ~ train tl6pressured • ~_ Repaired equipment difficulties Reduced /increased inlet gas rates with ___ _ Completed flare testing Fadlity maintenance mpleted Corrected E$i 9uctustion /failure ~T Other; 2 ~ _ i~ ~ a~,/~..~ Corrected E&I fluctuation /failure ar'v+ - - at other facility (T&b) Bieck Smoke pia incident ra3u8e black snake? Yes: No: ~ (If Yes, Continue with this section) Did )ncidertt present a potential thit~t to human hearth pr safety? Yes: ^ No: Ta/ (I(Yes, report to FEC as soon ds pae+aible. fl Nia. report to AOEC with 24 hours.) Stack smoke emitted from source: (enter tag number and description) Notified ADEC by Faxon: pate; Time: Report the following Information tp ApEC Within 24 AOUrst3Y FAX (907 2tiS~7508): Date and time of blade smoke event: From: To: Volume flares which generated black Smoke (rf diflerertt from above): MSCF BBL.S Oesoeptlon of steps to minimize emiseians: See Section B, above. Type of materials burned: C~as: N~al,B: f3ttter. G®nerai Weather: AirTe3mparature: ~ Wind SpeadlOireotian: Name atttf phone number of person making the report: _ _ Nana Phone No. Based on information and belief formed after reasonalle inquiry, I certify that the statements and information In and attached tp this document are true, aFcurate and om )Etc. • Facility Supervisor ~ late EC1C Supervisor, PRB 6 (flare gas and blat:k smoke inddents) Fieltl Environmental Complianre Coaniinatora, PRB 7 (Slack Smoke inddentS only) PBU/GPMA Fiend Malingers, {Black arnoka irtadents only GPMA Cperatlons F~tgineering Technical Aitle. (GPMA reports only - AT4 477) Kupantk: FIeKt i=tlvironmerttal Compliance Goardinators, NSK 61 (bare gas and black smoke inoiderrts) upasrea FEG 6/0t3 P:16roar~slNSEt'1Envkanmentnl HelplFortnslFxre C,pa Vonting Form s-9a.ws 12-30-00 08:30. From-ALPINE NS~fT FLARE GAS VENTING R~POIRT -SKA. INC. • PRUpHOE BAYIGP! FAGIt17Y: ~.~Itcl~•• ••t3~eiY:: PERMI? NO. GAS DISPQSITION Date of Occurrence: /~ a -t~flere Qverst (mmldd' yy) (Cheek Selection) Total Volume Flared: ~~N1SCF SBLS tdt~ertio-=• .:~ B .Fact ^PWrv:ed [$'rtn (check Selection) (Lisbtrmf! OntY -Gas Haled was lrorr+ ^ ^ Downstream (Chadc ~) of TEG ContaCtormsterat LPC) T-276 P.02/02 F-490 Ti of Occurrence. From: ~/ To: ~ G•! _ ~~ From: To: ~,.-_ _ _.-~ From: To: From: _ To: _ From: To: _ From= To: ~- _ Total Minulas Flared: _ ~ ~ (Includes volume f1d+1~d ~~ ge»erated WaCK smolre• Jf iAPJJcable) A. tleseriptlon of 1nCfdont and Cause: (Cheek as many as needed tP iuily deserlbe tha inGiderK) E!A T1Ci for ~~ TIC SD due ro hien exhaust temperature ~~ seat oli system sitlicutties ,.~ • EMERGENCY SHl]TOCWN ~~ lJeCtiiCal / instrumerrtation maflunction -~ Electficat J insvumernation malturwtion at ocher faailty (T6D) -~ Gas transit system overpressure tracking CPF/ROw Statiann out Excessive / insufficient irtiet gas rates irtto tadlny B. ACtIOn Taken to Eliminate Cause and Prevent Rocurrertce: (Chock and dasCrlHe as applloahle) Started !restarted T/C # .~-~f '~ Compressor! train depressured Reduoad /Increases inlet gas rates -'~ Completed Aare testing ~•- Corrected E&I flucwatian /failure '~~ Corrected E&1 flucn,ation /failure at other facility (T&Q) f3{aC~ e Process upset in kH~- SeClIOR of facility Flaring for orillaite shuttloti+m /startup i°lara system testirtg Faulty st-utdown on Faatity maitltenanoa High ambienttemperatures- $/p Cn high vibration ether: Stabilized facility process and operation Repaired eq 'meat ditA ties with '' Facility maintenance completed t]tl-er. pid incident Cause black Smoke? Yes• ~ Na ~ Uf Yes, oantinue with this section) Did incident present a potential threat to human haafth or safely'' Yes: Q No: L~ (If Yes, report to FEC as soon as possible. ff No, report to AR>`C with 241tours.(ertterfag number and tlescription) 81dck smoke emitted from Source: Time: Notified AOEC by Faxon: Pats: Report the toliowin9 (Motmation to ADEC wittrin 24 houreBy_F9~ (90'~ ~'7~1~ Date and time of Mack smoke snrertt: From: To: Volume flaratl wh~h generated black smoke (if different from above): MSCF BBLS pesrxlption of Steps io minimize emissions: See Section t3 above. Type of rnaterlals burned: Gae: ~ NGLs: ~~: General Weather. Air7smperature: _ Z - ~W~d Speadf~recti°n' Name and pitons number of person n9 ~® report Phone No. Name ~ _s.-_ ...-......ewe :ww~~inr t rssrYNthat ttie. statements and information in and attaches t0 this eased on mtormatton sort ucac~ ,v~n:~+ a.w.. ..-._ ...-.--.,.. __ document are we, accurate and mete. F'aeflity Supervisor Gm EOC Supervisor, PRB 6 (flare gas and black smoke incidents) Field Environmental CompliartCe Coordlnatore, PRB 7 (91aok Smoke incidents Doty) PBWGPMA Fiekt Managers, {Black smoke Incidents only) GPMA taperations Engineering Technical Aide. (GPMA reports only - ATtJ 477} I€uparuk: Fieltl Environmental Compliance foortlinators, NSK 61 (flare gas and black smoke inadents) - _-r ~„~ q~Cxaupa\t•+SE'i'lEn~hO~mentcA Mdp\Forrralflae G.as Ventk+p Form 8-08.:os