ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
FOOD 10-422 (Revised 4/95)
I Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
I Operator
ARCO ALASKA, INC.
4. Flared or vented ~reater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Pur~e
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL ~as equivalent produced
9. Purchased ~as
10. Transferred from:
11. Transferred to: CCP
Rem~rh:
;e:
I.'J
t;<Q
$
9
~
»,0
"'" ~)
~ 1!.ß
gg?
&i~
(1).
Q
~,,"
;3
=3
ffl~
<J>
~r
e-
J:>
%
"1
;;",'
n
(
n
<
1f."W·
i ~ ;
n
19.619
31.069
1.101.520
1.152.833
69,609,584
T herehv certify th~t the foregoing is tme ~nrl mrrect to the ht>_~t. of mv knowlerlge.
Signature: (/ ~
FOOD 1O~:~sed 4/95)
Title:
--"
-..J
~
c..O
<:T>
SUPERVISOR
I Field(s) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PB Dec-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
625
o
Offici~11 Use qllly--Harin~ Authorization> I hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
1/4"1'96
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - Gc-1
GAS FLARING INCIDENT REPORT
DECEMBER,1995
Page 1
e
Unplanned Events less than or equal to 1 hour I
:r::::::::rtþ.i.mtt:t::::::~::t:t:t:tt:.ttt::t:::t:t::::::::::::::t?::t!~ittt::t:::::::::Þ.~mijjfiQH::p.F:,-m;mlkt::i::ÞAø.ø:t::t:::::::::i:::::::::::::::::t::::::::::::::::::::~:ff:::::~::t:::*iDºii:T.#.iì&.:1øIib.MmÂfitçi.ø.$.¡;tt:::?:::::t::::tt:::::mt::::~:~
12/5/95 1846-1913 14 Not required for unplanned events which Not required for unplanned events which
12/5/95 1941-2026 24 are less than or equal to 1 hour are less than or equal to 1 hour
12/6/95 0438-0500 229
12/6/95 0530-0601 323
12/9/95 1256-1306 170
12/9/95 2006-2016 140
12/10/95 1130-1221 2,125
12/11/95 0840-0934 6,680
12/11/95 1242-1324 1,750
12/11/95 1651-1715 667
12/12/95 0021-0121 1,250
12/12/95 1621-1630 438
12/13/95 0157-0229 330
12/17/95 0924-0933 438
12/24/95 11 01-1114 135
12/24/95 1758-1834 1,125
12/27/95 1131-1155 2,833
12/28/95 0012-0042 656
12/29/95 1105-1112 292
TOTAL 19,619
e
Unplanned Events greater than 1 hour . I
·~::::::ttW:ø.Ajìt:::m:::?:::ttt::::::::::::::ltíY¡;:?:t:::?:::t:?:t::t::t:?MQjj.èI:~:¡:]:;:j:::¡::::øgi¢m_tU1fmmDm:~"::þ.Ä_?:ttt::::~???::::::::::::::::?:::::::~?:I::::::::IIAIbÞN:X4.tœN.mtQ::Iþ._iœÞiØ$.Îff::ttt::t:::m?:::~~::::::t::~
12/8/95 0407-0528 625 See Attachments See Attachments
TOTAL 625
ti~CL"t:~ V1t:D
JAN 1 7 1996
Alaska Oil & Gas Cons. Commission
Anchorage
1/4+96
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
DECEMBER, 1995
Page 2
~III [q .. :C'T:'rn n IIf:rrIIII [;11 I'] . :t:'T1'r.111 : ~.:., ~ 'I '(¡'[. f~:;.'~:.-:";~~.'>!>fM~':/
. . .........
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
TOTAL
ACTION TAKEN TO ELIMINATE CAUSE
o
I ~ ~.:C'T:'rn n ~.<oiqq.ll'i'r.'Il: r.mi[']:1 ~.<'¡:;Iq.I~1tlIItll'j [o:!"
e DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
TOTAL
e
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOLUME
ACTION TAKEN TO ELIMINATE CAUSE
o
TOTAL
19,619
625
o
o
31.069
51,313
r\clJc!vt:D
JAN 1 7 1996
Aìa:};;a on & GfiS Cons. Conlmission
Anchorage
e e
REPORT NO: 95-3134
Ii BPX FLARE REPORT
PRUDHOE BAY ..
FACILITY: GC-1 DATE: 08 Dec 95 TOTAL VOLUME: 625 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 04:07 TO: 05:28 1 Hrs. 21 Mins. IX] D D D 625 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
14°F.
2.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX reduced production rates and shut-in 2 well equaling 57 mmcfd. ARGO reduced production rates and shut-in 3
wells equaling 66 mmcfd. Wells were shut-in or choked back starting at 0120 hours.
2.
3.
4.
5.
~'"'\ C \..J r- ~ \j~";.: D·
~...V~.
JAN Î 7 1996
Ah,,,,,- 0,' i\
.,'-."d:i .¡ I}; CvC'ìl." Î:'~'~~'""I"~"I'O"
,,)'- V'I.o:EfHt~,,¡;~ If
Anchorage
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e
e
REPORT NO: 95-3145
BPX FLARE REPORT
PRUDHOE BAY ~
FACILITY: GC-1 DATE: 12 Dec 95 TOTAL VOLUME: 1,688 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:21 TO: 01 :21 1 Hrs. o Mins. D 00 D D 1,250 MSCF
2. FROM: 16:21 TO: 16:30 o Hrs. 9 Mins. D 00 D D 438 MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High ambient temperature swings resulted in flaring while bringing well pad on line. Ambient temperature increased by
16°F.
2. While bringing well on production following well work, TEG contactors exceeded maximum gas capacity and logic
opened flare valves.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX reduced production rates and shut-in 4 wells equaling 85 mmctd. ARGO reduced production rates and shut-in 5
wells equaling 150 mmcfd. Wells were shut-in or choked back starting at 00:25 hours.
2. Valves closed after contactor delta pressure decreased. This is under new TEG system protection logic.
3.
4.
5.
, ;i~
" i\1·......".U
,<"~~~~ ~-
c .",,'" ~# ~_¡¡ ..."
r~'~ ~~'\ ~ ~
~ J'\" C'
Jp..~ 11 \~'JQ
C "f'ìírÚssiOI\
, ;. j) COí\\>· \",.
^.. '·'''''3 ()\\ .J. (Ie
¡'"\\,"",,,.. . AI\Cnora~
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e
e
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
FOOD 10-422 (Revised 4195)
I Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
Operator
ARCO ALASKA, INC.
4. Flared or vented ~eater than 1 hour
(Supplemental report required-oSee 20 AAC 25.235)
5. Pilot and Pur~e
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
to. Transferred from:
11. Transferred to: CCP
Rem~rks:
REGEl' lEU
OEC 18 1995
Alaska Oil & Gas Cons, Commission
Anc:horag.
14.648
28.762
1.021,772
1.065.182
66,463,806
T herehv certify t~t the foregoinl! is tOle ~nci corr¡>,et '0 the hest of mv knowlecil!e.
() /-:
Signatur~e: .~ i/ / (' :/ .. Title: SUPERVISOR
/ / / ¡¿-</)--,,¿~
Form l() 2 (Revised 4/95)
I Field(s) JMonth/Year of Disposition
WESTERN OPERATING AREA-PH Nov-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
o
o
OlTiciul Use Only--Fluring Authorization:> I hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
MCF
3. Conserv. Pu11>Oses
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
12/5/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
NOVEMBER, 1995
Page 1
e
Unpla.nned E~e.nt8 less ..than or "e,qual to 1 hour I
¡:::j:i:::j:::j:::i:fP.i.ti:j:::j:::j:':ji:::::i:F[:::::j::::::::::ili:::i:::j:1::t:::::::::i:i:::i:::::::::::::::::;v~i:jt::t:::::i:::::i:::ºiªº.IDQ.k::Þ.I:!N.ÇW~':ij::¢APi'::::::::i::::::::::=:::=:::::¡::I:::::i:i:i=i:i:i:i::I:t::::::i:::::i:i:::::ii¢flbN:rildiì..::!tQ::IÞ.Mm'tfBtl.'iit't:::=:::tt:::::::m::t::::t::::t
11/1/95 1040-1049 63 Not required for unplanned events which Not required for unplanned events which
11/1/95 2352-2400 63 are less than or equal to 1 hour are less than or equal to 1 hour
11/2/95 0000-0032 467
11/2/95 0614-0644 456
11/2/95 2001-2022 292
11/3/95 0112-0146 236
11/3/95 0210-0219 63
11/3/95 0434-0451 116
11/3/95 1101-1139 132
11/3/95 2242-2307 260
11/4/95 0521-0533 125
11/4/95 0723-0736 21
11/4/95 2253-2311 166
11/5/95 1546-1634 160
11/7/95 0014-0027 135
11/7/95 0136-0152 146
11/6/95 1139-1145 17
11/9/95 0643-0911 1 ,167
11/10/95 1726-1600 2,630
11/23/95 2352-2359 170
11/24/95 0001-0026 632
11/24/95 2136-2214 792
11/26/95 0130-0145 208
11/26/95 1301-1326 1,736
11/26/95 1336-1430 3,750
11/28/95 1046-1111 399
TOTAL 14,646
e
12/5/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· GC-1
GAS FLARING INCIDENT REPORT
NOVEMBER,1995
Page 2
Unplanned Events greater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO EUMINATE CAUSE
e
TOTAL
o
Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
o
Planned Events Exceeding 1 Hour OR Exceeding 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
I
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
o
e TOTAL
Unplanned Events < 1 Hour 14,648
Unplanned Events> 1 Hour 0
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
Pilot Purge 28.762
TOTAL FLARED VOLUME 43,410
e
e
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
FOOD 10-422 (Revised 4/95)
Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
I Operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report required-oSee 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from:
.,.," í '1. t,,,
11. Transferred to: CCP
;-\\"skl 8: G.~;? Cons. Co
Anchorage
Remarks:
3,119
30,196
1,028,115
1,061,430
66,350,398
I herebv certifv that the forel!oiDl! is true and correct to the best of mv knowled2e.
!
Signature: /~ ." ..! /. ~. _ .
FOOD 1OcØ<Revised 4/95)
Title:
SUPERVISOR
Field(S) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PB Oct-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
o
o
!J.t1ici'll U~ Ol1ly--Fhlrin~ AUlhorizalion~!.!!!:...
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
11/3/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
OCTOBER, 1995
IUnplanned Events less than or equal to 1 hour
e
1
1 0/9/95
10/12/95
10/12/95
10/13/95
10/13/95
10/16/95
10/27/95
10/28/95
10/28/95
10/29/95
10/31/95
e
0433-0450
1606-1700
1242-1318
1529-1559
0919-0938
1818-1833
1753-1804
0706-0738
1456-1514
2119-2153
1505-1531
2011-2028
TOTAL
130 Not events
473 are less than or equal to 1 hour
300
104
132
188
138
625
250
331
271
177
3,119
Page 1
events which
are less than or equal to 1 hour
11/3/95
BP EXPLORATION {ALASKA} INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
OCTOBER, 1995
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
-~.._------- - -------------...-
TOTAL 0
e
IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
TOTAL
o
Unplanned Events < 1 Hour 3,119
Unplanned Events> 1 Hour 0
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 30.196
TOTAL FLARED VOLUME 33,315
Page 3
ACTlONTAKEI\I TO EUMINATE CAUSE
.
.
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Fonn 10-422 (Revised 4/95)
¡Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
Operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from:
L
, . t.
11. Transferred to: CCP
i"I~'j¡<.;;. & C&3 Con,1. C~mm¡{¡S¡OIl
Anchorage
Remarks:
13,717
7,531
29,104
968,151
1,018,503
61,845,215
I hereby certify that the fore20in2 is true and correct to the best of mv knowledll!e.
Signature: Û~ d'" _ Title: SUPERVISOR
FOOD lO@t(lievised 4/95)
Field(S) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PB Sep-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
o
Oflicilll U¡;C Ollly--FIllril~g Alllhori7alion > 1 hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
·
e
10/4/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
SEPTEMBER, 1995
Page 1
~I~ nïTi"r:'f. ~T[:]i1 Ç)'C'ITJ ~ Ir-lla'] .-or.11 r:ll r.1ii III'll1
I'ft~~!inATEfj'¡~~i':'1~ ;i",,","ME:¡~!{'~ ;··~!¡I\:':~:i¡':¡¡i VOLUME 6"[ :. DESCRIPTION OF INCIDENT" CAUSE(~!;::!'.:. ,.',' "
i'5.. ..¡'Wllji.~~~., . '" """",~'~;i ¡ ;;_..J.ii:JIl!L, ,,", ,,,~ " ~,::r, . t ~'~¡¡"'~I~'~"!:' 1, ":,,,," "',, ,,,,,, '"'' '" ' "'~¡'" "'" '" " , ",'" """"' ,',,, .'., " ",,:. ,I:"
9/1/95 0409-0458 340 Not required for unplanned events which
9/1/95 1944-2032 500 are less than or equal to 1 hour
9/3/95 1627-1711 275
9/5/95 0047-0145 600
9/5/95 0459-0547 500
9/5/95 0824-0846 230
9/5/95 1711-1751 275
9/5/95 2036-2105 215
9/6/95 0208-0304 775
9/6/95 1245-1342 600
9/6/95 1751-1810 135
917/95 0011-0103 400
917/95 0606-0658 794
917/95 1612-1644 101
917/95 2150-2233 300
9/8/95 1531-1616 313
9/9/95 1005-1055 330
9/10/95 2148-2204 120
9/13/95 0513-0527 1,560
9/14/95 1222-1247 260
9/15/95 1747-1800 135
9/17/95 0117-0130 226
9/18/95 0330-0355 503
9/18/95 0425-0432 972
9/18/95 1437-1450 108
9/18/95 1749-1823 333
9/19/95 0505-0518 271
9/19/95 2234-2252 163
9/20/95 1326-1353 637
9/21/95 0604-0621 73
9/21/95 1652-1720 233
9/22/95 0308-0337 554
9/22/95 2114-2122 44
9/24/95 1611-1622 92
9/29/95 1442-1518 750
TOTAL 13,717
.,~ACTIONTAIÇENT9ELlMINATEC~IJSEVr, .
Not required for unplanned events which
are less than or equal to 1 hour
'.' ", ~
10/4/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
SEPTEMBER, 1995
Page 2
II ~ nïTi'!'To I ::rr:m ~ I[ " H; ì
. an our
-8 9/11/95
9/12195v
-/9/13/95)
1'9/19/95 ,¡
9/21/95
e
e
2145-2400
0000-0116
2115-2230
1226-1327
0948-1128
TOTAL
~-,':;. ',.;' ';'''-
/.\J8,3t(~
4,200 See Attachments
1 ,580 See Attachments
780 See Attachments
879 See Attachments
92 See Attachments
7,531
See Attachments
See Attachments
See Attachments
See Attachments
~ ~ ~ (vEltJr ~
10/4/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
SEPTEMBER, 1995
Page 3
l~f;111ITq· Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
TOTAL
o
-
I ~ t;lllIT;I" ~'£'cJ li~. ~:(~;Z;Z.IIITt~J:I -Htì:.;:;Z· J lIt ..."'fIIIIII,'j ttj
TOTAL
e
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOLUME
r
;:'.
'.1 t.
i\tç3tG \)i:
GommlssiOrî
Anchorage
o
'; ;1,JRT~~'::1
13,717
7.531
o
o
29.1 04
50,352
REPORT NO: 95-3027
mi SPX FLARE REPORT
PRUDHOE SA Y
FACILITY: GC-1 DATE: 01 Sap 95 TOTAL VOLUME: 840 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 04:09 TO: 04:58 o Hrs. 49 Mlns. D 00 D D 340 MSCF
2. FROM: 19:44 TO: 20:32 o Hrs. 48 Mins. D 00 D D 500 MSCF
3. FROM: TO: Hrs. Mlns. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit pressure due to well unloading after POP.
2. High transit pressure due to well unloading after add perf.
Action Taken to Stop Flaring:
1. BP cut 15 MM gas rate, wells unloaded.
2. BP cut 28 MM gas rate.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: IBPX Representative:
e .e
Yes: No:
IDate:
REPORT NO: 95-3029
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 03 Sap 95 TOTAL VOLUME: 275 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1 . FROM: 16:27 TO: 17:11 o Hrs. 44 Mins. 0 00 0 0 275 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit line pressure due to wells unloading after pigging a GC-3 LDF.
Action Taken to Stop Flaring:
Wells finished unloading
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Repreeentatlve, . IDete: IBPX Repre.entet¡
Yes: No:
IDate:
REPORT NO: 95-3031
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DA TE: 05 Sap 95 TOTAL VOLUME: 1,820 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:47 TO: 01 :45 o Hrs. 58 Mins. D 00 D D 600 MSCF
2. FROM: 04:59 TO: 05:47 o Hrs. 48 Mins. D 00 D D 500 MSCF
3. FROM: 08:24 TO: 08:46 o Hrs. 22 Mins. D 00 D D 230 MSCF
4. FROM: 17:11 TO: 17:51 o Hrs. 40 Mins. D 00 D D 275 MSCF
5. FROM: 20:36 TO: 21 :05 o Hrs. 29 Mins. D 00 D D 215 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit line pressure caused by wells unloading after E-pad startup.
2. High transit line pressure caused by wells unloading.,
3. High first stg pressure when moving well from annex to test in test bank.
4. High transit line pressure due to ambeint temperature increase, causing CGF #1801 booster to operate in
EGT control.
5. High LPS gas rate due to well unloading after well work.
Action Taken to Stop Flaring:
1. BP cut 75MM gas rate. Arco also shut-in high GOR wells
2~ BP cut 30MM gas rate.
3. Shifted wells and s/i awell to D-bank.
4. BP cut 80MM gas rate, and ARCO also shut-in 80MM gas rate.
5. BP cut 30 MM gas rate LPS rate.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representa::
e .
Yes: No:
IDate:
REPORT NO: 95-3032
mi BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 06 Sap 95 TOTAL VOLUME: 1,510 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 02:08 TO: 03:04 o Hrs. 56 Mins. D 00 D D 775 MSCF
2. FROM: 12:45 TO: 13:42 o Hrs. 57 Mins. 00 D D D 600 MSCF
3. FROM: 17:51 ' TO: 18:10 o Hrs. 19 Mins. D 00 D D 135 MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit line pressure due to ambeint temperature, causing CGF booster to operate in EGT control.
2. High transit line pressure due to ambeint temperature. and well unloading.
3. High transit line pressure due to bringing wells back online.
Action Taken to Stop Flaring:
1. BP cut gas ratebut transit pressure kept rising. Had to cut about 130 MM before we finally got out of flare.
Arco also shut-in high GOR wells
2. BP/Arco cut gas rates by use of marginal sort.\
3. BP shut-in wells cut 20 MM gas rate
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: IBPX Representative:
e e
Yes: No:
IDate:
REPORT NO: 95-3033
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 07 Sap 95 TOTAL VOLUME: 1,595 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1 . FROM: 00:11 TO: 01:03 o Hrs. 52 Mins. 00 D D D 400 MSCF
2. FROM: 06:06 TO: 06:58 o Hrs. 52 Mins. D 00 D D 794 MSCF
3. FROM: 16:12' TO: 16:44 o Hrs. 32 Mins. D 00 D D 101 MSCF
4. FROM: 21 :50 TO: 22:33 o Hrs. 43 Mins. D 00 D D 300 MSCF
5. FROM: TO: Hrs. Mins. D D D 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High LPS gas rate when a well unloaded after well work. 29 minutes of flaring over period. (After well
unloaded, LPS compressor would periodically become ov~rloaded and pop to flare.)
2. High transit pressure with line packed. _
3. High gas transit line pressure caused by the CGF boosters slowing down when an additional 15mmscf gas was
routed back to transit while work was being done on EWE W40i gas injection well.
4. High gas transit line pressure caused by the ambient temperature causing CGF boosters to bog down due to
anti-ice system
Action Taken to Stop Flaring:
1. Cut LPS gas rate by shutting in 15 mm gas rate and switching wells temporarily to Annex until compressor
stablized.
2. Waiting for the higher GOR wells that Arco s/i BP s/i lower GOR wells to stop flaring. Will bring wells back
on after pressure drops.
3. WOA shutin approximately 55mmscf to reduce flaring and requested ARCO to reduce their higher GOR wells
in order to reduce transit line pressure.
4. BP cut approximately 80mm gas rate to stop flaring. Arco also shut-in high GOR wells to lower transit line
pressure.
. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representstive: .. IDste: IBPX Representet.
Yes: No:
IDate:
REPORT NO: 95-3034
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 08 Sap 95 TOTAL VOLUME: 313 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 15:31 TO: 16:16 o Hrs. 45 Mlns. 0 00 0 0 313 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit line pressure due to increasing ambient te_mp.
Action Taken to Stop Flaring:
BPX & Arco cut gas rates
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: / _ IDate: IBPX Representa~:
~ ~~
Yes: No:
IDate:
REPORT NO: 95-3035
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DA TE: 09 Sap 95 TOTAL VOLUME: 330 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 10:05 TO: 10:55 o Hrs. 50 Mins. 0 00 0 0 330 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
Rapid increase in gas transit line pressure when FS1 brought on a 70 mmscf well without coordinating with
ARCO EOC. The additional gas resulted in additional backpressure to the gas transit line which backed up the
interstage pressures to the compressors at CCP.
Action Taken to Stop Flaring:
ARCO initially reduced higher GaR wells to compensate for the additional gas rate which was produced to the gas
transit line. Both ARCO and BPX then took additional gas cuts to relieve the backpressure on the gas transit line
so that the CCP compressors could be of additional help in drawing down the transit line pressure.
C·
_,-,,:it
~ \".
., \.. I.
.-
f": 1.....\
';; 'v ~
(. "\1:~,_'\îSS\Q'{\
"~,r'''' Cul'it.H
.,.," ~ \..JI.,.;....,:)þ
l\ì' ,'"
J'\~C\;':ð.. . . ~'í\ """l'y"aß
-f"\~V'- l"!h"i~\...~G"
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: / ", IDate: IBPX Representa:
-
Yes: No:
Date:
~~
REPORT NO: 95-3037
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 10 Sap 95 TOTAL VOLUME: 120 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 21 :48 TO: 22:04 o Hrs. 16 Mins. D 00 D D 120 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit Gas line pressure due to CGF Booster compressors backing off.
Action Taken to Stop Flaring:
Arco & BPX shut-in high GOR wells, CGF Booster compressors ramped up.
~;;.,
'~
t." t 'I, (j,'¡'"
,~'.
'..' ¡
~,\¡;;::V::¡'
3:~
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: /~. \Date: IBPX Representa~,:
- ~~
Yes: No:
IDate:
REPORT NO: 95-3040
Li BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 11 Sap 95 TOTAL VOLUME: 4,200 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 21:54 TO: 24:00 2 Hrs. 6 Mins. D 00 D D 4,200 MSCF
2. FROM: 06:30 TO: 07:10 o Hrs. 40 Mins. 00 D 00 D MSCF
~FROM: 07:30 TO: 08:30 1 Hrs. o Mins. 00 D 00 D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Restart GC from total shutdown. There was insufficient gas to restart the compressors. Assist gas was added
after LPS compressor started to prevent black smoke.
Action Taken to Stop Flaring:
1. Started LPS Compressor.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Repre.entative: . IDate: IBPX Repre.enta.,
Yes: No:
IDate:
REPORT NO: 95-3041
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 12 Sap 95 TOTAL VOLUME: 1,580 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:00 TO: 01 :16 1 Hrs. 16 Mins. 0 00 0 0 1,580 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 D 0 D MSCF
4. FROM: TO: Hrs. Mins. 0 D 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 D 0 D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Continued flaring from total shutdown until insufficient gas to restart the IP & LP compressors. Assist gas
was added to prevent black smoke.
Action Taken to Stop Flaring:
1. Started I P & LP compressors
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: . IDate: IBPX Representative:
Yes: No:
IDate:
REPORT NO: 95-3043
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 13 Sap 95 TOTAL VOLUME: 2,340 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 05:13 TO: 05:27 o Hrs. 14 Mlns. D IX] D D 1,560 MSCF
2. FROM: 21 :15 TO: 22:30 1 Hrs. 15 Mins. D IX] D D 780 MSCF
3. FROM: TO: Hrs. Mlns. D D D D MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. While returning pad back to service after TAPS slowdown and GLT repairs, a slug from Y-LDF caused a
surge of gas to hit the contactors. This caused loss of TEq from contactors. Gas was flared to stablize the plant.
2. High transit line pressure when CGF booster compressors. bogged down due to +40 of ambient temperature.
Action Taken to Stop Flaring:
1. BP Shut-in 200MM gas
2. Arco & BP Shut-in 50MM gas to to lower transit line presssure. BP cut an additional 50MM after transit
pressure did not subside after 45 min.
f~""
r
"'-/
~~\as}~'2i.
~L
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representstlve: . loste: BPX Represents.
Yes: No:
IDate:
REPORT NO: 95-3045
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 14 Sap 95 TOTAL VOLUME: 260 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 12:22 TO: 12:47 o Hrs. 25 Mins. I&J 0 0 0 260 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 D MSCF
3. FROM: TO: Hrs. Mins. 0 D D D MSCF
4. FROM: TO: Hrs. Mins. 0 D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit pressure due to CGF booster compressors bogging down when ambient temperature increased.
Action Taken to Stop Flaring:
BPX shut in 125 mmscfpd
. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: .. IDate: IBPX Represantat.
Yes: No:
IDate:
REPORT NO: 95-3046
Li BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 15 Sap 95 TOTAL VOLUME: 135 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 17:47 TO: 18:00 o Hrs. 13 Mins. D 00 D D 135 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit line pressure caused slugcatcher to pop to flare.
Action Taken to Stop Flaring:
BPX cut LPS gas rate
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Repressntstivs: . loste: IBPX Represents¡
Yes: No:
IDate:
REPORT NO: 95-3048
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 17 Sap 95 TOTAL VOLUME: 226 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 01:17 TO: 01:30 o Hrs. 13 Mins. D 00 D D 226 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit pressure due to CGF bypassing L TS #3 to prevent loosing reefers.
Action Taken to Stop Flaring:
BPX and ARCO cut gas
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: IBPX Representat~:.
.... '~ ~
Yes: No:
IDate:
REPORT NO: 95-3051
mi BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 18 Sap 95 TOTAL VOLUME: 1,916 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 03:30 TO: 03:55 o Hrs. 25 Mins. D 00 D D 503 MSCF
2. FROM: 04:25 TO: 04:32 o Hrs. 7 Mins. D 00 D D 972 MSCF
3. FROM: 14:37' TO: 14:50 o Hrs. 13 Mins. D 00 D D 108 MSCF
4. FROM: 17:59 TO: 18:23 o Hrs. 24 Mins. D 00 D D 333 MSCF
5. FROM: TO: Hrs. Mlns. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Flaring off 3rd stages because of low LP gas rates. Assist gas on to keep from black smoking.
2. Flared off HP sep. at GHX 1 due to mechanical problèl'!1-with back pressure valve PV 9980.
3. Gas transit line pressure was already increasing due to the rapid increase in ambient temperature (10
degrees F increase
in less than 3 hours). When EWE gas injection compressor SD, an additional 105 mmscf gas was routed into
the gas
transit line, thereby, further increasing the gas transit line pressure.
4. Due to high trasit pressure caused by outside high ambient temperatures.
Action Taken to Stop Flaring:
1. Rates became higher allowing compressors to pump better.
2. Back pressure valve working again alowing pressure to drop.
3. ARCO and BPX shutin about 150 mmscf gas to the gas transit line, and the EWE gas injection compressor was
restarted.
4. Arco / BPX shut in gas.
. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Repre.entati.e: . IDate: I BPX Repre.entat.
Yes: No:
IDate:
REPORT NO: 95-3053
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 19 Sap 95 TOTAL VOLUME: 1,313 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 05:05 TO: 05:18 o Hrs. 13 Mins. 0 00 0 0 271 MSCF
2. FROM: 12:26 TO: 13:27 1 Hrs. 1 Mins. 0 00 0 0 879 MSCF
3. FROM: 22:34 TO: 22:52 o Hrs. 18 Mins. 0 00 0 0 163 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Due to high transit pressure GHX1 flared off HP SEP. dry flare.
2. High gas transit line pressure due to rapidly increas.in-g ambient temperatures (over 10 degrees F in 3
hours).
3. High transit pressure due to outside temps and unloading well at GG3.
Action Taken to Stop Flaring:
1. BPXand ARGO cut gas rates.
2. BPX and ARGO reduced over 300mmscf gas to lower gas transit line pressure.
3. BP and ARGO s/i in high GaR wells.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: e IDate: IBPX Represent:;:
Yes: No:
IDate:
REPORT NO: 95-3055
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 20 Sap 95 TOTAL VOLUME: 637 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 13:26 TO: 13:53 o Hrs. 27 Mins. D 00 D D 637 MSCF
2. FROM: TO: Hrs. Mlns. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit pressure caused by rising ambient temp. Temperature increased from 42 F to 51 F.
Action Taken to Stop Flaring:
ARGO cut 40 mmscfpd and BPX cut 172 mmscfpd.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
.
....
Yes: No:
IDate:
REPORT NO: 95-3056
Ei BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 21 Sap 95 TOTAL VOLUME: 398 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 06:04 TO: 06:21 o Hrs. 17 Mins. 00 D D D 73 MSCF
2. FROM: 09:48 TO: 11 :28 1 Hrs. 40 Mins. 00 D 0 D 92 MSCF
3. FROM: 16:52 TO: 17:20 o Hrs. 28 Mlns. D 00 0 D 233 MSCF
4. FROM: TO: Hrs. Mlns. 0 D 0 D MSCF
5. FROM: TO: Hrs. Mins. D D 0 D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit line pressure, due to adjusting wells after X-Pad shutdown maintenance work.
2.High transit line pressure, due to increase in ambiel1ttemperatures.
3. High transit line pressure, due to increasing ambient temperatures. 65 degrees.
Action Taken to Stop Flaring:
1. BPX cut 55 mm gas and readjusted wells.
2. BPX cut 140 mm gas and adjusted wells as needed.
3. BPXlARCO cut 110 mm additional gas rates.
. If >11 HRS., the PCC will notify AOGCC (907) 279·1433. STATE TELEPHONE REPORT?
AOGCC Represontotl.o, . IDot., I BPX Represents¡
Yes: No:
IDate:
REPORT NO: 95-3059
mi BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-1 DATE: 22 Sap 95 TOTAL VOLUME:
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned?
1. FROM: 03:08 TO: 03:37 o Hrs. 29 Mins. D IX] D D
2. FROM: 21 :14 TO: 21 :22 o Hrs. 8 Mins. D IX] D D
3. FROM: TO: Hrs. Mins. D D D D
4. FROM: TO: Hrs. Mlns. D D D D
5. FROM: TO: Hrs. Mlns. D D D 0
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK:
CONTROLLED BLOWDOWN:
First Determination of Cause:
1. High transit gas line pressure.
2. "A" Bank Slugcatcher flare valve "open."
Action Taken to Stop Flaring:
1. Arco / BPX cut gas rates ( 54 mmscfd ).
2. PCC trimmed 18 mmscfd LPS gas.
If >11 HRS., the PCC will notify AOGCC (907) 279-14-33. STATE TELEPHONE REPORT?
AOGCC Representative: e Date: IBPX Representa¡
598 MSCF
VOLUME
554 MSCF
44 MSCF
MSCF
MSCF
MSCF
OTHER:
Yes: No:
Date:
REPORT NO: 95-3061
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GCø1 DATE: 24 Sap 95 TOTAL VOLUME: 92 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1- FROM: 16:11 TO: 16:22 o Hrs. 11 Mlns. 0 [Ñ] 0 0 92 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 D D D MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High line pressures resulting from returning H pad wells back to service after line pigging.
ARGO had increased rates to make up for the cutback du(ing pigging operation.
Action Taken to Stop Flaring:
Four well were shut in to cut gas and get out of flare. Total of 85.6 mmscfd.
, If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: e IDate: IBPX Representa¡
Yes: No:
IDate:
REPORT NO: 95-3062
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DA TE: 29 Sap 95 TOTAL VOLUME: 750 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 14:42 TO: 15:18 o Hrs. 36 Mins. D 00 D D 750 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit pressure due to loss of #1 MI compressor.
Action Taken to Stop Flaring:
1. BPXlARCO cut gas rates to reduce transit pressure.
'" If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
. ~
Yes: No:
IDate:
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Fonn 10-422 (Revised 4/95)
Facility .
GATIIERING CENTER I
Disposition
I. Sold
2. Reinjected
e
3. Flared or vented less than 1 hour
operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report requircd--Sec 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
,
8. NGL gas equivalent produced
e
9. Purchased gas
10. Transferred from:
II. Transferred to: CCP
Remarks:
23,729
32,314
1,024,239
1,080,744
65,880,200
I herebv certifv that the forel!oinl! is true and correct to the best of mv knowledl!e.
Signature: (/)--¿ __ _ Title: SUPERVISOR
Form IO-4~R~~S;:;;
Field(S) JMonth/Year of Disposition
WESTERN OPERATING AREA-Pß Aug-95
*lndicate contribution of each pool to total.
o
Pool Name
,
Code
Percent
o
PRUDHOE
100
640150
462
o
Official Use Only--Flaring Authorization> I hr.
1. Safety
\~
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
o
Commissioner
Date
Note: AJI volumes must be corrected to
pressure of 14.65 psi a and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
, .
9/6/95
IUnplanned Events less than or equal to 1 hour
e
UA TF.
8/1 i9!>
8/2/95
8/3/95
8/3/95
8/3/95
8/4/95
8/4/95
8/4/95
8/5/95
8/5/95
8/6/95
8/6/95
8/6/95
8/6/95
8/7/95
8/8/95
8/9/95
8/9/95
8/10/95
8/10/95
8/11/95
8/11/95
8/11/95
8/12/95
8/12/95
8/12/95
8/12/95
8/14/95
8/14/95
8/15/95
8/15/95
8/15/95
8/15/95
8/16/95
8/16/95
8/16/95
e
11M I::
1245-1308
0512-0542
, 0436-0507
0603-0612
21 08-2134
0155-0224
2227 -2313
2249-2338
0537 -0559
0642-0708
0429-0455
0813-0835
2012-2029
2209-2230
0013-0051
1508-1519
1658-1729
2235-2308
0206-0248
1205-1224
'0227-0310
0230-0259
2032-2040
0416-0431
0655-0713
0924-0936
1624-1633
0459-0516
1847-1906
0749-0810
1342-1359
1750-1801
2137 -221 0
0015-0059
0210-0220
1311-1323
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
AUGUST,1995
Page 1
I
VOLUME DESCnll'TION OF INCIUENT & CAUSE
96 Not required for unplanned events which
35 are less than or equal to 1 hour
108
31
144
108
319
272
17
144
271
153
118
146
396
76
10,764
344
1,050
330
747
201
56
104
150
92
63
118
132
142
200
76
344
306
69
83
ACTION TAKEN 10 ELIMINA TE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
'.
,
~.
9/6/95
e
8/16/95
8/17/95
8/17/95
8/18/95
8/18/95
8/21/95
8/21/95
8/28/95
8/29/95
8/30/95
8/30/95
8/31/95
8/31/95
8/31/95
2159-2214
1207 -1236
1831-1854
0947-1040
1744-1808
1411-1426
1718-1740
0745-0823
1648-1710
1304-1342
2041-2051
1122-1144
1805-1 836
1911-2000
TOTAL
e r~ t. ..'~','; t \)
SEP 1 8 1995
A\aS~a Oii &. Gas Cons. Commission
~ \ l\Ilcboraga .
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
AUGUST,1995
Page 2
104
443
160
1,362
250
156
168
369
718
449
90
225
750
680
23,729
.,
.
9/6/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
AUGUST,1995
Page 3
IUnplanned Events greater than 1 hour I
f't::t:::::ÞAT§:tt'::::::fj:::::,::::t::::::j"wMg:':fj'::f::j':':t::::::::::::::::::{i:VQgQMg:::::':::::::::::::::::::::pg§9.R!ffI!ptfpg'í.Jiþ!Q.gfftjij:9A:4$§.,:I:::::::::::::::'::::::=:f:if={:::::If::::=:::=::::::::::::f:AÇDP«::tr&<.§tÜtQ',ªMM!«4+ê.=:ÇAq$~::::::ff::m::=:m:=j:::::::::::j:f:::\f:
naÎ4Î9Snn .. n.ni ä1ä~1956 .. .. ...nn 139 See Attachments See Attachments .. .. . . n.nn . .
8/4/95 1949-2110 108 See Attachments See Attachments
8/10/95 1619-1743 100 See Attachments See Attachments
8/16/95 0933-1107 115 See Attachments See Attachments
e
TOTAL
462
e
9/6/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
AUGUST,1995
Page 4
1;;:':;;:~~~~'Ë::~~::;:;';;I~;~g~:~:;:~:::j;:ljj:;:]~:~øM~~:~jj~;j:~j;~~;:~¡~;~~~~q[3i~T:r4Aµ§§mj:::::t:;¡:::::t:::jlj¡ilif0:{;;:¡¡:::f0¡¡::A9I!9fÆIAß§H,:mt~t§g'M!~1ê:çAº$.~:::::::;::;:::j;:ItI:::::;::::::::::;::I::
TOTAL
o
Iplanned Events Exceeding 1 HourORExceedinëg 5000Mcf . ..... ...... ... ..... . ... ... . .. .. ... ..... ... .... . ... ... .. . ...... .. ... ... .... .... . .......... .. ... .. . I
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED VOLUME
o
TOTAL
23,729
462
o
o
32 314
56,505
R L\_L;\,'ED e
e
~ c.r 21 1995
REPORT NO: 95-2992
Li
Alaska Uìl & Gas Cons. Commission
Anchorage
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-1 DATE: 04 Aug 95 TOTAL VOLUME: 946 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 01:55 TO: 02:24 o Hrs. 29 Mins. D 00 D D 108 MSCF
2. FROM: 18:18 TO: 19:56 1 Hrs. 38 Mins. 00 D D D 139 MSCF
3. FROM: 19:49 TO: 21:10 1 Hrs. 21 Mins. 00 D D D 108 MSCF
4. FROM: 22:27 TO: 23:13 o Hrs. 46 Mins. D 00 D D 319 MSCF
5. FROM: 22:49 TO: 23:38 o Hrs. 49 Mins. D 00 D D 272 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit line pressure due to packing off line with additional production.
2. Gas Transit line high pressure due to wells unloading.
3. LP Gas Transit line high pressure due gas breakthrough well E11.
4. HP Gas Transit line high pressure due to Ambient temp. increase.
5. LP Gas Transit line high pressure due to Ambient temp. increase.
Action Taken to Stop Flaring:
1. BP cut gas rates.
2. Shut in gas from marginal sort with ARGO.
3. Shut in gas from marginal sort with ARGO.
4. BP cut gas.
5. BP cut gas.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
RL e e
- ~ .y, h 95-3001
- L. I 'w t U REPORT NO:
mi ~[r 21 1995 BPX FLARE REPORT
Alaska vII & Gas Cons Comm" . PRUDHOE BAY
. ISSIOO
Anchorage
FACILITY: GC-1 DATE: 10 Aug 95 TOTAL VOLUME: 1,480 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 02:06 TO: 02:48 o Hrs. 42 Mins. D 00 D D 1,050 MSCF
2. FROM: 12:05 TO: 12:24 o Hrs. 19 Mins. D 00 D D 330 MSCF
3. FROM: 16:19 TO: 17:43 1 Hrs. 24 Mins. 00 D D D 100 MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High gas transit line pressure which was caused by rapidly increasing ambient temperatures.
2. Ambient temp. increase raised transit gas line pressure high.
3. LP flare open while LP wells were unloading briefly causing the LP flare valve to open a total of 18mins.
Action Taken to Stop Flaring:
1. ARCO and BPX reduced gas rates to the gas transit line.
2. Cut gas rate per GaR sort between BP and ARCO.
3. Cut LP well rate.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3009
R "t'_ {"'.-..
_LI '" cU
.. t.
BPX FLARE REPORT
~) [1' 2 1 1995 PRUDHOE BAY
Alaska UII & Gas Cons. Commission
FACILITY: GC-1 An~RCf~ 16 Aug 95 TOTAL VOLUME: 677 MSCF
I nterm ittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:15 TO: 00:59 o Hrs. 44 Mins. 0 00 0 0 306 MSCF
2. FROM: 02:10 TO: 02:20 o Hrs. 10 Mins. 0 00 0 0 69 MSCF
3. FROM: 09:33 TO: 11 :07 1 Hrs. 34 Mins. 00 0 0 0 115 MSCF
4. FROM: 13:11 TO: 13:23 o Hrs. 12 Mins. 0 00 0 0 83 MSCF
5. FROM: 21:59 TO: 22:14 o Hrs. 15 Mins. 0 00 0 0 104 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High Transit Pressure due to ambient temp. increases.
2. High Transit Pressure due to ambient temp. increases.
3. High Transit Pressure due to ambient temp. increases.
4. High Transit Pressure due to ambient temp. increases.
5. Arco wells unloading
Action Taken to Stop Flaring:
1. Shut in high gor wells.
2. Shut in high gor wells.
3. Shut in high gor wells.
4. Shut in high gor wells.
5. GaR sort shut in BP and ARGO wells
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e
i'
"
e
ii' -ij ,- ? <'_ :!!~ ¡ .' ~ _~ t:','t
ALASIV\íQIL A.NDGASiCO~SER~*,T'O~i:C;.QMMISSIdN
FACILITY REPORT OF PRODUCED GAS DISPOSITION
FOOD 10-422 (Revised 4195)
Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
Operator
ARCO ALASKA. INC.
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from:
11. Transferred to: CCP
Remarks:
7,801
3,447
29,192
947,638
988,078
64,611,327
I herebv certifv that the forel!:oinl!: is true and correct to the best of mv knowledl!:e.
Signature: d. ~
t.OOD lO-4~R~ViSed 4195) II
Title:
SUPERVISOR
Field(S) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PB Jul-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
Official Use Only--Flaring Authorization> I hr.
1. Safety
MCF
o
2. Lease Use
MCF
o
3. Conserv. Purposes
MCF
o
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
8/3/95
BP EXPLORATION (ALASKA) INC.
¡p,RUI/>HOE BAY UNIT-GC-1
GAS FLARI'1~ INqDENT REPORT
JULY, 1995
Page 1
_Unplanned Events less than or equal to 1 hour__..._""._
trr:t\Ø#m:\:m?::t:::f:~::f:f::¡tfi,gf~~:::¡:::¡:¡tt:¡tt:::f::¡:::¡:~:~IºQJ.Mi:tfffff])'G.$QIRt~9"])'f~:æø.JQiNt:"::9.Äq$.;::::¡t¡tf¡tt:}}::¡:::1:¡t:}¡t:::::¡~:~f:::::::::Ä9j1ºH.::::t~mtçféJMi.N.iîf§)fAijjg:::!:¡::t:¡:¡:}ff}!@}::¡t:::¡@
e
7/1/95
7/2/95
7/3/95
7/4/95
7/6/95
7/8/95
7/13/95
7/13/95
7/15/95
7/15/95
7/15/95
7/16/95
7/16/95
7/19/95
7/20/95
7/20/95
7/20/95
7/24/95
7/25/95
7/25/95
7/25/95
7/25/95
7/28/95
7/29/95
7/30/95
7/30/95
7/30/95
7/30/95
7/31/95
,
"
e
1058-1153
0854-0927
1110-1145
1803-1815
0129-0143
1115-1134
2003-2037
2123-2152
0023-0053
1412-1424
1641-1656
1046-1129
2110-2122
1123-1148
0001-0015
0935-1001
1210-1228
1417-1429
1020-1045
1315-1335
1615-1640
2255-2316
1031-1058
1935-2030
1136-1147
1150-1217
1403-1435
2145-2228
0916-1938
1628-1637
1658-1714
TOTAL
688 Not required for unplanned events which
275 are less than or equal to 1 hour
201
108
156
200
307
121
417
33
73
2,400
49
69
190
524
300
208
35
69
87
73
188
382
31
94
111
149
92
38
133
7,801
Not required for unplanned events which
are less than or equal to 1 hour
8/3/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT -C¡C-1
GAS FLARI",C¡ INClDE;~T REPORT
JULY, 1995
IUnplanned Events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT" CAUSE
7/5/95 1826-2002 1,067 High gas transit pres. due to ¡ncreas ambient temp
7/27/95 0433-0540 838 High transit line pres. due to unloading EOA Wells.
7/28/95 1903-2003 417 High gas transit pres. due to increas ambient temp
7/29/95 1148-1309 1,125 High gas transit pres. due to increas ambient temp
e
f .~
TOTAL
3,447
e
Page 2
ACTION TAKEN TO ELIMINATE CAUSE
Arco and BPX cut gas rates.
Arco and BPX cut gas rates.
Arco and BPX cut gas rates.
Arco and BPX cut gas rates.
8/3/95
BP EXPLORATION (ALASKA) INC.
PRUQHOE BAY UNIT - GC-1
GAS FLARIH~ INCIDENT REPORT
JULY, 1995
kpJannPJU=~~¡r¡\-....~"~~':"~':'"T."''''': "II: 1"ai '-=-~,:-rl.;.' ~ ¡II ~ r:11~.<~::::' t1'i'!'='J~(I:'I.' ~
DATE
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
TIME
TOTAL
o
e
JPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
DATE TIME VOLUME DESCRIPTION OF INCIDENT'" CAUSE
TOTAL 0
,
..,
TOTAL
Unplanned Events < 1 Hour 7,801
Unplanned Events> 1 Hour 3,447
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 29 192
TOTAL FLARED VOLUME 40,440
Page 3
ACTION TAKEN TO ELIMINATE CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
e
e
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Form 10-422 (Revised 4195)
I Facility
GATHERING CENTER I
Disposition
1. Sold
2. Reinjected
3. flared or vented less than I hour
operator
ARCO ALASKA, INC.
4. flared or vented greater than 1 hour
(Supplemental report required--Sec 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from:
11. Transferred to: CCP
Remarks:
.?
Ä-<:" ".-.......
:;:;\:"1
m
()
m
<J-}
<
n¡
C:'
9,220
10,064
28,723
1,021,495
1,069,502
65,514,788
I herebv certifv that the foregoing is true and correct to the best of mv knowledge.
Signature: tL~
t'orm 1O~R~~iSed 4;;)- ""
(, ~r
,(- C":¡ "_~~
~<
;7
':;;
;;- ;~
;1.
í¿
g~
Title:
SUPER VISOR
Field(S) JMOnth/Year of Disposition
WESTERN OPERATING AREA-PH Jun-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
640150
100
Official Use Only--Flaring Authorization> I hr.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psi a and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
7/12/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MAY, 1995
IUnplanned Events less than or equal to 1 hour
.:tt:¡::roM.§::::fi:::¡:¡:::¡:¡m:://:¡/t:¡MÞl.iUMftf:::/:::::¡::::tQ§$.¢.RI.Bí'ºH.:ÞFJ~Çtø.§fttj¡,ÇAº$.f#::::¡:/::::ff:
e
:.:.:.:.:.:.:.:.:.:.:......:....;;,;.¿:.;.:.:.:.:.:.:.:
,}},:,,:,::,::,ÐA':,::c>,""::':}:::'
...........'..................................................,
6/1/95
6/1 /95
6/2/95
6/6/95
6/6/95
6/7/95
6/9/95
6/9/95
6/10/95
6/10/95
6/12/95
6/12/95
6/14/95
6/16/95
6/17/95
6/17/95
6/18/95
6/19/95
6/19/95
6/19/95
6/20/95
6/21/95
6/23/95
6/28/95
e
1352-1403
1356-1405
1137-1201
1305-1329
1950-2015
0919-0951
0629-0723
0822-0858
0040-0132
0831-0843
0720-0738
1412-1457
1344-1437
1 033-1130
1 027 -111 0
1312-1344
1635-1701
1404-1436
1516-1548
1810-1907
1431-1512
2303-2340
1424-1511
1245-1307
TOTAL
~.
~'
t' H?
:::. tf:¡
:;:-- c-,
~ '......J
o
!~
.;¡.
:.:~
M
(r)
õ'
::;¡
/t)
n-í
n
f"ìï
-
<:
n¡
r-.,
,~.,".,
1,994 Not required for unplanned events which
240
83 are less than or equal to 1 hour
183
260
250
338
175
542
92
449
597
552
673
209
111
108
229
220
469
569
240
335
302
9,220
Page 1
)))iJJ'::{:::::'AÇÍl.ºH.JAKgN:[ÞJ;t.i.I.M.I.ff.ATgÇAº~{'
Not required for unplanned events which
are less than or equal to 1 hour
7/12/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MAY, 1995
Page 2
e
IUnplanned Events greater than 1 hour
DATE TIME VOLUME
6/2/95 0427-0537
6/2/95 1250-1432
6/2/95 1525-1631
6/2/95 2141-2400
6/7/95 1815-2016
6/9/95 1052-1207
6/11/95 1344-1452
6/13/95 1924-2359
6/19/95 0935-1110
6/25/95 1455-1625
6/26/95 1726-1837
6/29/95 1551-1654
TOTAL
I
DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELlMINATEÇAJ.I$1i;}=)
729 High Transit line pressure. ARGO trimmed gas rate.
350 High Transit line pressure. ARGO trimmed gas rate.
470 High Transit line pressure. ARGO trimmed gas rate.
1,158 High Transit line pressure. ARGO trimmed gas rate.
667 High transit pressure and increasing ambient temp. BPX / ARGO cut gas
938 High transit pressure and increasing ambient temp. BPX / ARGO cut gas
756 EWE compo K3151 SID due to flameout on turbine. ARGO /BPX s/i 6 wells totaling 176 mm in gas.
1,528 ARGO increased rate causing high transit gas press. BP cut gas.
677 High transit pressure and increasing ambient temp. ARGO/BP trimmed gas rate.
1,560 High Transit line pressure. EWE compr. flame out Re-started Ewe compressor and trimmed gas rate.
750 High Tran. pres. ARGO bring on high GaR wells ARGO/BP trimmed gas rate.
481 High transit pressure and increasing ambient temp. BPX / ARGO cut gas
10,064
e
£~-~ c:-,:·r-ii
n
Iï:ï
. ,¡
'~.j~\
<
M""1
!~~
,~-c-__..
7/12/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MAY, 1995
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
......._-.... ..........................-.-."... ,......
.... r::r:þ.~!5::::::::::{{::):rrtTI!\ßE)?
:::::V9bºMgr:w:::::r9~$ÂR.,ffr,qN:Þf:'N.ç~þg¡rrl~çµ§§\:.·..
....
...
TOTAL
o
Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Met
e:::::rWP~T§r:::::::::::;PM§:::::i::::::Y9M.U'-'ft::::::þ§§ÇR'BJ]9N9F.!~~m;)'§N[f:~çA-º~g:
TOTAL
o
TOTAL
Unplanned Events < 1 Hour 9,220
Unplanned Events> 1 Hour 10,064
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and °
exceeding 5,000 MCF
e Pilot Purge 28 723
TOTAL FLARED VOLUME 48,007
!:"'~
?:
fï¡
f~''''
.' }
fTI
F~·"
i
§~
:ç
<
r-n
o
.,.....j
....-
Page 3
..
.... :..... . .:·:··.Aq1pON 1'AKEN TO ELlMI~[~ CAUSE
I
....,.........--..-.
.....................
.....................
......................
.....................
.....................
......,..............
.................... ."
I
rrAºT!QR1'AKgN[ºJ;;J,.J.M!N.Äl'gÇA!J§~)
e
e
//
~ .
REVISED
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Form 10-422 (Revised 4195)
Facility
GATHERING CENTER 1
Disposition
1. Sold
2. Reinjected
3. Flared or vented less than 1 hour
Operator
ARCO ALASKA. INC.
I Field(s) JMOnth/Year of Disposition
WESTERN OPERATING AREA-PH May-95
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
9. Purchased gas
10. Transferred from:
11. Transferred to: CCP
"tarks:
-"Y)
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
5,054
44,558
29,942
1,003,418
rt';
Official Use Only--FIaring Authorization> 1 hr.
~,,,,...,..."'O
1,082,972 1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
I~r~<,
Commissioner
Date
68,296,865
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authoritv 20 AAC 25.235.
, certify that the forel!oioll is we and correct to the best of mv knowledl!e.
,-,
.'
..
6/19/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· GC-1
GAS FLARING INCIDENT REPORT
MAY, 1995
Page 1
IUnplanned Events less than or equal to 1 hour
e
DATE
5/6/95
5/8/95
5/12/95
5/13/95
5/14/95
5/16/95
5/16/95
5/17/95
5/19/95
5/19/95
5/21/95
5/25/95
5/25/95
5/25/95
5/27/95
5/27/95
5/28/95
5/29/95
5/30/95
e
_,.__ ,n.
TtME
0049-0135
1618-1638
1620-1705
1456-1555
1523-1600
0939-1 018
1430-1525
1857-1956
0604-0649
2144-2201
0557-0628
0001-0017
0515-0528
0727 -0812
0843-0911
2049-2058
1146-1230
0457-0553
0754-0817
TOTAL
VOLUME DESCRIPTION OF INCIDENT & CAUSE
224 Not required for unplanned events which
111 are less than or equal to 1 hour
211
451
231
271
382
1,024
195
83
388
67
27
94
97
63
275
700
160
5,054
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
. ,
,
.
6/19/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MAY, 1995
Page 3
~1r.mrM'5\.':i,.'L;) If~ 'fl:I-i-'llT. ~I.II'].I:!. LI ~ f. ."¡~.lll.~"~) II ~ r:rI ~:(t3::J:q. tfiTt'l.ilIII11 l'l r.J
::::::¡::m~tHi~!T§~::tt::~~::::~~~::::m::::::tttnMilt:t::::::::t::::::::~:::::::::::::::::MpbQMif:::~:::::::::t::~:~::QiÎçmfmPtB;~fnlø.~Q§Kr:I.::çliµ§it:::::::t~~::::m:::::::JJ:::I:::::::::::~~:::::::::::::::::::~::~::~:APJiN11tíi$.N::J;9il!M!fm;t§:pÅY§itt}:..
TOTAL
. ...
o
~ ~"''''L':J.'5\.':i,.,¡;) I f~'Ñ:<t3::;::I.rl.I' .·....~.]II..,J-:-Ø:(t3::I:I..(III...'tltltll'j
e DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
5:'21'95 1016-1124 1,587 CGF tandem compressor SD for minor repair
5/28/95 1313-1501 3,817 K3200 GL T compo was sId to perform minor maint.
TOTAL 5,404
e
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events > 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOLUME
. . .... ...
ACTION TAKEN TO ELIMINATE CAUSE
ARC 0 and BPX reduced gas rates.
BPX reduced gas rates. K3200 was restarted
TOTAL
5,054
39,154
o
5,404
29 942
79,554
p't:CEiVED
,\.
r. 1 WOf:
I iN / ,,}..;v
\....1', t 1-
& Gas Cons. CommissiOn
Anchor::
"4¡'¡£
4,:4;..(~
, I
1·1:·.
,,\-~,..
-!.
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
IFacility
GA 11IERTNG CENTER 1
I~rator
Field(S) I
WESTERN OPERATING AREA - PBU
IMonthlYear of Disposition
Apr-95
Disposition
Volume MCF*
*If production comes from multiple pools,
indicate contribution of each pool to total.
Pool
Percent
1. Sold
o
eeinjected
t: é/C~ /.-~("
/({~0
o
3. Plared or vented less than I hour
17,225
4. Flared or vented greater than I hour
(Supplemental repon required..S.. 20 AAC 25.23:5)
49,267
5. Pilot and Purge
29,168
OfOcial . Use Only-Flaring Authorization» hr.
6. Used for lease operations
1,005,920
1. Safety
MCF
7. Other (production sent to CCP)
54,224,516
2. Lease
MCF
TOTAL
55,326,096
3. Conserv. Purposes
MCF
.. All volumes must be corrected to pressure of 14.65 psi a and to a temperature of 60 degrees F.
ing the month of disposition. Authority 20 AAC 25.253
Remarks:
Report due by the 20th of the month
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature
~~
J. ¡ ~.-~
Title
s~
Date:
0ßS-
Form 10-422
Rev. 11194
· .
"
5/4/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC·'
GAS FLARING INCIDENT REPORT
APRIL, 1995
Page 1
e
... ~~1a,~Ar:"'"$N!~L":f!~.,Nrr.IT."~;wr.M".4Jr.."· .-
tffff¡ºits.::ff¡rr~¡rrrr:ftüi§t:¡:¡::r:fmm¡:¡::~mmmrrrVQ,ºiftrr:fftfÞ§$.¢.I.fjRDW¥ºf~~WÇJgifß¡jiÞÄi$.gf¡:ff::fm~¡rmmm@::fmr:¡:¡:::f@::¡'@::¡:f:A9U9ÜmìNf.§Nlrtfi'ï.Ml.NÄíi.)'ªº§G::::::::f@~::r:::::@::f¡:::::f:m
4/3/95 0034-0118 665 Not required for unplanned events which Not required for unplanned events which
4/3/95 0118-0147 1,410 are less than or equal to 1 hour are less than or equal to 1 hour
4/3/95 0147-0206 287
4/3/95 0222-0311 3,828
4/3/95 1914-1945 3,028
4/4/95 1643-1708 1,111
4/7/95 0631-0645 1,332
4/7/95 1605-1620 2,083
4/7/95 2041-2128 2,448
4/26/95 1724-1736 1,033
TOTAL
17,225
e
~ ,f¡: 1.1.~.:,·~·¿.~ ,Ù'I'I ¡. ': ¡"(.] .'(.:: 1,..·lr,~II·
,
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
4/1/95 1320-1622 3,160 Skid 18 compressors not loading. Shut compressors down and restarted
~4/1/95 1725-19411~'J~~~'~~~J.Þwf..,r¡4,423 Odd reboiler SD. Reduced gas rates, restarted odd reboiler.
~/3/95 2239-2359 6,402 Even reboiler SD. Reduced gas rates, restarted odd reboiler.
~ 4/10/95 0722-0849 5,981 Took their Odd train contactor "off line" to repair leak Put Odd train contactor back on line.
\4/17/9.5......... 1450-1515 r /10,417 ~ost the TEG circulating pumps at GHX 1 Restarted Circulating pumps.
~/17/95 . .1534-1608 16,315 ost the reboiler at the GHX 1. Cut rates to annex.
4/29/95' '-" 1726-1922 1,611 igh Transit Pressure BPX and Arco cut gas
4/30/95 1516-1625 958 High Transit Line Pres. with increase ambient temp. BPX and Arco cut gas
TOTAL 49,267
. .
. .
5/4/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· GC-1
GAS FLARING INCIDENT REPORT
APRIL,1995
Page 2
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT", CAUSE
TOTAL
ACTION TAKEN TO ELIMINATE CAUSE
o
Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Met
e DATE TIME VOLUME DESCRIPTION OF INCIDENT 81 CAUSE
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED Va..UME
I
ACTION TAKEN TO ELIMINATE CAUSE
o
. .
... . . .
.TQ1 ~!-
17,225
49,267
o
o
29 168
95,660
".
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GA TIIERING CENTER 1
I~rator
I Field($) I
WESTERN OPERATING AREA - PBU
IMonthlYear of Disposition
Mar-95
Disposition
Volume MCF'"
"'If production comes from multiple pools,
indicate contribution of each pool to total.
Pool
Percent
1. Sold
o
2. Reinjected
o
3aed or vented less than 1 hour
11,214
4. Flared or vented greater than 1 hour
(Sapplemo.... noporl noquinod--S.. 20 AAC 25.23')
16,340
5. Pilot and Purge
30,941
Orficial Use ()nly.I~I.ring Allthmi7.Rlion>1 hr.
6. Used for lease operations
1,050,943
1. Safety
MCF
7. Other (Production sent to CCP)
54,304,283
2. Lease·
MCF
TOTAL
55.413,721
3. Conserv. Purposes
MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
following the month of disposition. Authority 20 AAC 25.253
Wrks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature f~J3C-h.1/A ~"-j jtu,~::> /tvl Title .:s~,~~'\. ~d.r~ ~ð
Date: '--II, 2.. { ~ j/
Form 10-422
Rev. 11/94
I'~:l:,::~,:: '
4/6/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MARCH,1995
e
IUnplanned Events less than or equal to 1 hour
u fj:j1.ÄT$.·':{:j\\tnM¡:::':fftft\j:::::M9,ºM¡\:::::{i\j::::þ$.$çij!8TI.PH.:ÞfÜRÞIQIH.î=:j¡'@#.Yª"f¥:f:::ff::,\:f: ..
3/4/95 1620-1656 250 Not required for unplanned events which
3/7/95 1828-1850 3,560 are less than or equal to 1 hour
3/11/95 1228-1252 133
3/22/95 0927-0947 1,042
3/23/95 1937-2013 1,250
3/27/95 0430-0530 885
3/28/95 0351-0432 569
3/29/95 1315-1409 3,525
TOTAL 11,214
Page 1
::f/\*ºÏIºH.:']ti~tt9:~M!il)\Ig:Ç#.º$§ttt:::,
Not required for unplanned events which
are less than or equal to 1 hour
IUnplanned Events greater than 1 hour
:::::f::QÄïW:,:::,:::j:f:'{:J1M§t:mft/ /H{MótUME:::J· :, DESCRIPTION OF INCIDENT~ CAuSe: . ····,:::AÓTIO&TAKEN::'tÕELiMINATE¢Au.SE..::{}
3/22/95 0518-0707 ................u15,1á9uË"efl·reboilersid,·lost 'rËG ·incontractors. u..uResiartedrêhoiíêr~·····u,u",.....".,u", .
3/25/95 0303-0701 1,201 LP Compo could not remain online at present rates. Restart of LP Compressors.
TOTAL
16,340
e
3J2.2 _ ~"tiy t/~ 6't)
+)/&\ I IAIHI\1 & Te.ß.
3/zK' Ntl Y 4 t1~,
~ .
4/6/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
MARCH, 1995
Page 2
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
::/PA1§;:; ....... :. ·:·:.llME.:))f::::f)::))::::YÞkºM¡;::::¡::i:r:::t::ºJ.?~9RjfÌ!PN::9f7riç1Þ§tfl.t~::çì.µ~Î:;:¡I:¡::::;::::::::
TOTAL
."".-"'''-'-
..,..
. . .........
................ .
::;:::::;::::¡:¡:~9.!,ÞNmr~K~r.f[q:~t!M!f@¡~:¢Aº~))
.....................
....................
.....................
....................
.....................
............,..'....................
o
IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED VOLUME
o
TOTAL
11,214
16,340
o
o
30 941
58,495
RECfEIVED
APR 1 7 1995
Alaska Oil & Gas C
AnChor~~~' Commission
;~
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I
Facilíty
GA TIIERING CE~ 1
I~rator
Disposition
Volume MCF*
1. Sold
e Reinjected
I:
3. Flared or vented less than 1 hour
4. Flared or vented greater than 1 hour
(Supplemental report requiJedooS.. 20 AAC 2S.23S)
20,280
5. Pilot and Purge
30,109
6. Used for lease operations
(includes 2as ¡ lift 2as)
7. Other (Production sent to CCP)
990, I 4 I
56,029,442
TOTAL
57,070,667
~te: All volumes must be corrected to pressure of 14.65 psia and
.owing the month of disposition. Authority 20 AAC 25.253
Remarks:
Field(S) I
WESTERN OPERATING AREA - PBU
*If production comes from multiple pools,
indicate contribution of each pool to total.
Pool
o
o
695
Officilll UKC Only-Flaring Alllhori7.llIilln> 1 hr.
1. Safety
2. Lease
3. Conserv. Purposes
to a temperature of 60 degrees F.
Report due by the 20th of the month
and correct to the best of my knowledge.
I hereby certify that the foregoing is true
Signat'" cÝ.~··ð
Title
Form 10-422
Rev. 11194
5~
IMonthlYear of Disposition
Feb-95
Date:
Percent
MCF
MCF
MCF
0o~$-
3/1/95
IUnplanned Events less than or equal to 1 hour
2/3/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
FEBRUARY, 1995
2249-2259
695 Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
695
e IUnplanned Events greater than 1 hour
2/5/95
2/7/95
e
0707 -0833
0658-0819
TOTAL
8,750 Reboiler problems on even train.
11,530 Even reboiler sId due to condensate problems.
20,280
REGEIVED
MAR 1 4 1995
Alaska Oil & Gas Cons. Commission
Anchora
~A-l WAS R.6 ßOILEo~ ~
\,!J-j".... J)orV6 T<> ,,^\I'IIMlt~
v.>f1 Y ~ I\ÞPE.Ntü 7 tV Id;
~~ I~UI)~1ð ~
Not required for events
are less than or equal to 1 hour
Cut gas rates to GC -1
Gas cuts made.
Page 1
I
3/1/95
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
FEBRUARY, 1995
Page 2
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
I
TOTAL
o
e
IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
TOTAL
o
:." ~." TPTAJ-
Unplanned Events < 1 Hour 695
Unplanned Events> 1 Hour 20,280
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED VOLUME 20,975
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 1
Field(S) I
WESTERN OPERATING AREA - PBU
I~rator
Disposition
Volume MCF*
*If production comes from multiple pools,
indicate contribution_-O~each pool to total.
" "
Pool ,,\
"" \
\
1. Sold
o
\
J
2. Reinjected
e
3. Flared or vented less than 1 hour
o
3,757
4. Flared or vented greater than 1 hour
(Supplemental report requireduS.. 20 AAC 2.5.ns)
5,000
5. Pilot and Purge
43,864
Official Use Only-Flaring Authorization> 1 hr.
~ \ p. Used r kli$(. u}'.,ratI~" s
~ (includes gas lift gas) /J1:u.Á
c /\ "\
7 Other (Production sent to CCP)
1,127.470
1. Safety
37,866,427
2. Lease
TOTAL
39,046,518
3. Conserv. Purposes
All volumes must be corrected to pressure o( 14.65psia and to a temperature of 60 degrees F. Repòrt due by the 20th of the month
month of disposition. Authority 20 AAC 25.253
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Si,."." cf. 'J-£:. ,
-- Title
J~-~' ¿")
Form 10-422
Rev. 11194
IMonthlYear of Disposition
Jan-95
Percent
MCF
MCF
MCF
Date: 2hhj
FEB 06 '95 10: 49AM BP EXPLORATION TAX
aOGCC Gas Flaring Be Venting Incident R.rt GC-1
P.2/4
DOR Reporting
hit 1 . Unp"lIIIId __ ~ aoeectNlg1 hOllt
~
VaIulM,
fttCt
1.286
a,uo
222
Sell. S2 (Þ1) ::J.:.æ
1)118
1J1QIM
11111II5
'II18IDS
TotiI
leo. .. End. TIIIHIII
Dlnllan
0G40-0830
Q506.06OO
0Ø46-Cr7a0
Totot
Sch. B2 (ÞS)
J \
, :Þ11'1r \
VolwIea
Met
5000
6,000
oesclipllOn of
II'IOICImbi a c-e
Odd and Ewn RøÞol... 1IId.
AcrlOtl Taken to
Eliminlllll CllUse
FIC..1aruId IWboI18ß1lnd CUI9IS iate.
Part Z UI'IPIIIMtd....... SIMtIIr IhIn 1 haur
811I. & I!nd. T1mtI
DIlle DurJ1lon
1/1&'95 030+0418
,.,. S tllBnnad 8Y8ntII nat ncøødIng 1 hour AND not exceecnng 1000 Mer
<tilt
980." End. Timeø Yol_
DIII8 Dur8don ~
Delcrlpllon of
InIIldell!4l." c.....
Actian TaIœn to
Eliminate Cause
T....
SOh. 82 (114)
o
,-', "....... _rellJl1l88dl"ll1110.. 0.. eøeealngl5OO0 Met
I
AOGCC lid R8ring 6 Ytmlinglnold8nt Repart
100. a End. TifMS e1hr :Þ1'"
Dahl Dunllivn YaI_ Duradon Val.... tlMcrtplion 01
<:1 hour "III )0 1 ,*,r MCf Incide.... a c__
TIII8I Sch. 82 (b6) 0 0
AOGCC Api
LlBn <1l1r -!:Z!r
Lf1114 ~ 1h1' ~
AOGCC tlpl 43.864
u..S "'016 "''''' Sch. B2 (Þ2)
Unl7 COlllllluoua A....I leb. B2 (bõ) 0
Adon T.rœtI to
.,lInt"* c.....
(1) "..auIhor\2ellon reQuired for Gellng and venUns when letting a weQ Þeloro legula, øl'CduCtiOn
OOA Aeponlng
(b1)
(b2)
(Þ3)
(114)
(b5)
(b6)
(0)
EmerlOp Up <1 No TIX
PIIO...-urge NO TI)c
ErTltr>1 NoTu
PIIU\. c1&c!lOOO No Tax
IIIdllDens. Le... No TIX
AuIhoriød Tax
UMUlhJWU18 TuIP_hy
S.7S7
43,(184
5.000
o
o
o
FEB 6 '95 11:46
913756441394
PAGE. 002