Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutBPX - GC3 '<'.::;;w.::;I~:'~~WA;e;~~~r/##/P/&-'D.-W/I/I/I/I/I/I/#ar/.M~.I/#W/1/1/1/1/1/1/1/1/1/Æ'Ø~I/Ø/M..ø/'/Ø/I/Ø/lhtI'/4#!W'/""'/~""'/14dII9'MI/,ØY"'A%1WI/#'#'1/8/~'~Æ'6/..v/I/H/,ØYI"/M~¥%Ø'/~t"/A~Af AGOCC GaS DiSpoSitioIl Flles 1995 ~PK...QC ¡¡:A:;:;;·ik;;{f'~~;¡¡¡"/'Mi74Ø~~WI/4fPYA'Y#'dWØ;;øyI/dlfYdf'Y¿¡¡YA'Y.dWAY4'h'WdiWAf;:6'/:ilfJYL~A'YA'Y..iWdiWl:f/ØYAWØ~,,¡f p.M;#'A?Y#/.JW.4fIVIAI/IP.fIP:{,i!/{/.4fIV'¡¡ wI/I/AJIfV,,({fK/Af':/ßJlJY.IIWA1P'.Jf!¥Ao/¿¡¡Y4V-IfIIV-lfllVL4Y7Æ'1714'ÓfllYdiW.I/ßII':/.l4iPYÂ%~./mAf~Mó4j'~',;a , ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator ARCO ALASKA, INC. MonthN ear of Disposition Dec-95 e Disposition 1. Sold 0 2. Reinjected 0 3. Aared or vented less than 1 hour 9.832 4. Aared or vented ~reater than 1 hour 0 (Supplemental report required-oSee 20 MC 25.235) 5. Pilot and Pur~e 13.522 6. Used for lease operations 615.283 7. Other 0 TOTAL items 1 - 7 638.637 y;. ,,~ ~~. '~'. 8. NGL ~as equivalent produced ;¡-p é/ \; , 0 \þ )7_ '{ "Q , {\. 9. Purchased ~as ~t.:¡t, .... ~"'...,) 0 ç~"~~ "..l ¿""-! ?~ <;;..1- ~ \~ti '- 10. Transferred from: ~ 'qi 0 c> (") Ö ~; (]I ~f¿ 11. Transferred to: CCP 61 28.225.926 í:l :: Rem:lrb: T herehv certifv that. the foregoing i~ tme ami mrrect to the he~t ofmv knowlerlge. Signature: Þ4. - Title: SUPERVISOR Form llLLI"" ~!-1evlsed 4Nj) e *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 Official Use Only--Flarin' Authorizalion > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT DECEMBER,1995 Page 1 e Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT a CAUSE 12/6/95 0209-0244 365 Not required for unplanned events which 12/6/95 0426-0517 417 are less than or equal to 1 hour 12/6/95 1317-1328 115 12/7/95 1802-1855 550 12/9/95 1632-1700 219 12/10/95 1125-1216 2,833 12/11/95 0313-0333 500 12/11/95 0840-0907 656 12/11/95 1249-1259 174 12/13/95 0154-0243 1,360 12/17/95 0302-0312 67 12/19/95 1817-1841 150 12/19/95 2218-2258 2,056 12/27/95 1750-1810 278 12/29/95 1437-1511 92 TOTAL 9,832 ~ Events greater than 1 hour :¡/:¡:¡/:::tÞ.4n;::::t'/'¡'::f::::¡:¡::::/::::::ttlMittt¡//::/:::¡::::/,t://v9lÞli::tt::::¡m:'¡:tÞi$.ÇijOjJJQN::,Qf{!N9jQINlfj:¢iÞ.U:ttttftt::t::¡,:::,,//t:::¡:¡:¡:¡:f::f::ttl¢Ðº,ttÄK§N:::tQ::iwMmA'î§:p4Q$.g:f:/:/¡:::¡::::::::¡:tfft::¡:/ ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL o e ¡'of" ',~ ~'¡"'" "-,q,." '" V4 b '? ¡f",,?, ~:'''' 'f ¡ ~'" 'l,) "~,ts 0/ , ? 'f;,J /1 Æ ,,,\ ¡':J" ~ 5..'t.<")... ~. t./L\ ",·t;¡"ìfß" v""u "0Cj¡ "Of'} N liO;; 'Ò, r'! $,7"" ....t)';,,,,. ~''"' '''·''1 -¥·/¡';;3"'· lOll BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT DECEMBER,1995 Page 2 r.Jr.":rr.Tl";~..,.»t~J es. Than or Eaual1 Hour AND Not Exceedlna 5000 Met I fmrm:r::þ.i.ti.:::::::::tfffff:r:j::IÎ!M$.mf::j:j:::f:::::::{:::::::m::m::j:}lgMi:fmrmfffÞil«mPDQN.mQfJNÞ!Þøt::.j:Þ.Â.::::::::::::::tjIIr::r:::::::::::::::::::::::j::t:f::::fm:¡::¡UØNltjØtUttflbwHÄm:«iij$.i::t¡::::::::m:::::::::m¡¡:¡:::¡:¡:::¡:¡:¡r:¡: TOTAL o Planned Events Exceeding 1 Hour OR Exceeding 5000 Met e :¡:fmm::::m:PAtlfIfmrrm:::::r::::::rtt!Mifffff¡rrr:f:::::::r:¡YQþjjl¡:j:t¡:t¡::::mm:ÞiømêñgÑ¡:Qf]H«GiH:Þí.::QAø.H:¡:¡:t¡r:j:¡:::::::::m:::::mrrf:::::::¡:::::::::¡::r:tffiWø.jJt."jU~N/tQ::è.ÞMWÄjjtÞAø.$.$.:m:j:¡r::::::::::::::::r:::::::j:j::::m::::::: TOTAL o TOTAL Unplanned Events < 1 Hour 9,832 Unplanned Events> 1 Hour 0 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events> 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 13.522 TOTAL FLARED VOLUME 23,354 . \¡ ~;,;O ..'; ,~... \ ... i6- .""," ,,' 'f. .~_ ( ";;. ìi..- ........ JP-." '\ 1 1~SS I"N'lIf\ÚSS\on r·('\·~S V·;,.;>'\· ,."\ ~ Ga~) ~,V" . '''aO' .~ ~ e N,¡)'t:;,- " þ..."Ic\\û!ag ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator ARCO ALASKA. INC. Field(s) Month!Year of Disposition WESTERN OPERATING AREA-PH Nov-95 e Disposition 1. Sold 0 2. Reinjected 0 3. Aared or vented less than 1 hour 3.915 4. Aared or vented ,greater than 1 hour 12.990 (Supplemental r uired--See 20 AAC 25.235) 5. Pilot and Purge 12.062 6. Used for lease operations 593.458 7. Other 0 TOTAL items 1 - 7 622.425 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 26.747.501 Remarks: T herehv cert.ifv that the foregoing i~ tme anct corrf'.ct to the he~t of mv knowlf'.rlve. -:{- " Signature:._j/ L:)~.;,~..-;.,.,--- Title: SUPERVISOR Form 1O~ (RevIsed 4195) e *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 OtliculllJsc Only--Flurin Allthorizutinn > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT NOVEMBER,1995 Page 1 Unplanne.!t~Y..!t_l.:'ts less than or equal to 1 hour I :::::::t:::tH>.,mm::::::':::::::::::::::::::::::::¡::::¡¡:ttlj::::::::::t¡::::::::::::::tt::::::':ttf.øijQI::::'::::t::¡::¡ttQ~mgnº":¡ºf:'W~P'ijijl::.]MQØ::::t::¡¡:::¡::¡¡::::t:t::t¡:'::::::::::::::::t:¡::::::::¡::¡:t:::':'.Qitt."I¡N::Tq::iQï.ÎN.AtI:çiy.iiI¡:~'i';8m::::::::::¡:::'::::::::¡%: 11/4/95 1630-1653 413 Not required for unplanned events which Not required for unplanned events which 11/9/95 0844-0901 213 are less than or equal to 1 hour are less than or equal to 1 hour 11/17/95 0531-0614 299 11/17/95 1657-1711 194 11/17/95 1825-1918 264 11/18/95 0706-0725 238 11/23/95 2342-2359 354 11/24/95 0001-0022 438 11/26/95 0104-0153 688 11/26/95 2330-2358 397 11/27/95 0220-0245 417 TOTAL 3,915 e Un .Ianned Events ! rester than 1 hour DATE 11/10/95 11/20/95 11/24/95 11/27/95 11/28/95 e TIME 1255-2345 0740-1218 2036-2211 0427 -0550 2029-2208 TOTAL VOLUME DESCRIPTION OF INCIDENT a CAUSE 8,855 See Attachments 1,062 See Attachments 1 ,469 See Attachments 271 See Attachments 1 ,333 See Attachments 12,990 ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments See Attachments See Attachments See Attachments RECEIVEU orc 1 8 1995 Alaska Oil & Gas Cons. Commission Anchorage ~ BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT NOVEMBER, 1995 Page 2 r.J(:('rrrl"!.~...n.t~J !'Á.Á._T;hfW..lV-FlV~AI1 Hour AND Not ExceedlnaJ)~O M.C?' ,_ 1 ¡::::'::::::ff:'Atlif:{:¡:¡::::¡¡:¡:::¡{mmm'{TIMI{{m:mf"¡:f¡'f¡:¡:¡:fffl<Nae.::::m::::::¡:f':¡:m:þgJ.QflOtnºrifpf:1H.Ç~Þe.~1\1::çi.ºe:{{{{mf::::"::¡':::::::::¡::::¡:::i¡::{::{m::::::::¡:::f¡iggN.:tå.:l!tø::éYMÎiÂi.i.E:çi.ت~tt::¡::{:::f::¡:¡:¡:::¡::::::'ff::::¡: TOTAL o ~~~ITrrl"!.~....w~Jxceedln(l1 Hour OR Exeeedlna 5000 Mef ._ ".___ ",,_ .__ "_..._ I o TOTAL TOTAL Unplanned Events < 1 Hour 3,915 Unplanned Events> 1 Hour 12,990 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events> 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 12 062 TOTAL FLARED VOLUME 28,967 e e REPORT NO: 95-3107 Ej BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 10 Nov 95 TOTAL VOLUME: 8,855 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 12:55 TO: 23:45 10 Hrs. 50 Mins. D 00 D D 8,855 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. LP compressors and TEG regeneration system shut down because of a power failure at GC-3. The loss of the LP compressors resulted in the flaring of all third stage separator gas. 2. 3. 4. 5. Action Taken to Stop Flaring: 1. BPX began cutting rates at 1300 hours while GC-3 technicians identified the cause of the power failure. The initial gas cut totalled 450 mmscfd. Assist gas was added to the flare to prevent black smoke flaring. 2. At 1400 hours, it was reported that the power failure was the result of significant damage to circuits and power would not be returned for an unspecified length of time. BPX immediately reduced gas rates to the minimum (475 mmscfd) to insure that production lines were not subject to freezing. Assist gas was continued to prevent black smoke. 3. At 2345 hours, the GC-3 electrical system was repaired and the LP compressors were returned to service. 4. 5. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-3112 Ei BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 20 Nov 95 TOTAL VOLUME: 1,062 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 07:40 TO: 12:18 4 Hrs. 38 Mins. D 00 D D 1,062 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. It was observed that the flare header pressure was gradually increasing from an unknown source. The flare valves indicated close. 2. 3. 4. 5. Action Taken to Stop Flaring: 1. Operations personnel dicovered during a thorough search that an LPS compressor discharge psv, located outside on an overhead piperack, had failed and was leaking into the flare header. The spare was put in service and the leaking psv was isolated. A sensing line on the psv was found to be faulty. 2. 3. 4. 5. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-3116 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 24 Nov 95 TOTAL VOLUME: 1,907 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 00:01 TO: 00:22 o Hrs. 21 Mins. D 00 D D 438 MSCF 2. FROM: 20:36 TO: 22:11 1 Hrs. 35 Mins. 00 D D D 1,469 MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High gas transit line pressure caused by GGF compressor problems due to Boosters slowing down High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by +9°F. 2. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by +12F. 3. 4. 5. Action Taken to Stop Flaring: 1. BPX reduced production rates and shut-in 5 wells equaling 129 mmcfd. ARGO reduced production rates and shut-in wells equaling 80 mmcfd. Wells were shut-in or choked back starting at 23:52 hours. 2. BPX reduced production rates and shut-in 10 wells equaling 243 mmcfd. ARGO reduced production rates and shut-in wells equaling 234 mmcfd. Wells were shut-in or choked back starting at 1857hours. 3. 4. 5. RECEIVi::U OEC 1 8 "95 Alaska Oil & Gas Cons. Commission Anchorage If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-3121 mi BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 27 Nov 95 TOTAL VOLUME: 688 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 02:20 TO: 02:45 o Hrs. 25 Mins. 0 IX] 0 0 417 MSCF 2. FROM: 04:27 TO: 05:50 1 Hrs. 23 Mins. IX] 0 0 0 271 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by +7°F. 2. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by +11°F. 3. 4. 5. Action Taken to Stop Flaring: 1. BPX reduced production rates and shut-in 4 wells equaling 104 mmcfd. ARGO reduced production rates and shut-in wells Wells were shut-in or choked back starting at 02:27 hours. 2. BPX reduced production rates and shut-in 3 wells equaling 66 mmcfd. ARGO reduced production rates and shut-in wells Wells were shut-in or choked back starting at 05:15 hours. 3. 4. 5. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-3125 . Ei BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 28 Nov 95 TOTAL VOLUME: 1,333 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 20:29 TO: 22:08 1 Hrs. 39 Mins. IX] 0 0 0 1,333 MSCF 2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by +16F. 2. 3. 4. 5. Action Taken to Stop Flaring: 1. BPX reduced production rates and shut-in 9 wells equaling 229 mmcfd. ARCO reduced production rates and shut-in wells. Wells were shut-in or choked back starting at 20:28 hours. 2. 3. 4. 5. RECEIVt::u OEC 1 8 1995 Alaska Oil & Gas COns. wnmission Anchorage If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator ARCO ALASKA, INC. Field(s) MonthN ear of Disposition WESTERN OPERATING AREA-PB Oct-95 1. Sold o *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 Disposition 2. Reinjected o 3. Aared or vented less than 1 hour 12,252 e 575 5. Pilot and Purge 11,770 6. Used for lease operations 599,603 e 9. Purchased gas i.. ~. L... ~ \I t... o ........-...- Official U~ OJlly--Flllrin AUlhorilation> 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date 7. Other o TOTAL items 1 - 7 624,200 8. NGL gas equivalent produced o 10. Transferred from: o 11. Transferred to: CCP Anchorage 26,915,633 Remarks: I hereby certify tbat the forel!oÍßI! is true and correct to the best of my knowledl!e. I / (r /L._') _,_~_--- Title: SUPERVISOR BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT OCTOBER, 1995 Page 1 e Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/2/95 0156-0228 4,889 Not required for unplanned events which 10/10/95 1413-1500 5,940 are less than or equal to 1 hour 10/12/95 1216-1314 960 10/12/95 1529-1534 80 10/30/95 2205-2251 383 TOTAL 12,252 ~Unplanned Events greater than 1 hour ;:D~rE i, '. TIME ;, VOLUME DESCRIPTION OF1NCIDENT & CAUSE 10/16/95 1621-1742 575 See Attachments TOTAL 575 ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN Tº~UMINATE CAUSE Not required for unplanned events are less than or equal to 1 hour e BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT OCTOBER, 1995 Page 2 Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCìDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL o e Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct ..;: "ATE·! ... TIME· VOlUME ... ·OESCRIPTlONOFINCIQ!;~ & CAUSE .. AÇ:'TIQN TAKEN :rOELlMINATJ; CAUS~ TOTAL o Unplanned Events < 1 Hour 12,252 Unplanned Events> 1 Hour 575 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events> 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 11 ,770 TOTAL FLARED VOLUME 24,597 e e REPORT NO: 95-3074 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 16 Oct 95 TOTAL VOLUME: 575 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 16:21 TO: 17:42 1 Hrs. 21 Mins. IXI D D D 575 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High Transit pressure caused by wells unloading that were brought on following CCP compressor #1809 start-up. 2. 3. 4. 5. Action Taken to Stop Flaring: 1. BPX cut1 00 mmscfd starting at 17:00 2. 3. 4. 5. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: ¡Date: I BPX Representative: Yes: No: IDate: ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator ARCO ALASKA, INC. Field(s) WESTERN OPERATING AREA-PB e Disposition 1. Sold 0 2. Reinjected 0 3. Aared or vented less than 1 hour 9,863 4. Aared or vented greater than 1 hour 11,969 (Supplemental report required-See 20 AAC 25.235) , 5. Pilot and Purge 14,476 6. Used for lease operations 519,202 7. Other 0 TOTAL items 1 - 7 555,510 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred úom: 0 11. Transferred to: CCP 23,465,513 Remarks: I berebv the fores!Oiol! is true and correct to the best of mv knowledl!e. Signature~~~ Title: SUPERVISOR t'orm IIJ-4;¿;¿ {Kevl " e *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 , '.. --..-. OJ1iciul Use Oll!r--Flllrin , Auth~)rilali()n > ] hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT SEPTEMBER, 1995 Page 1 I Unplanned Events less than or equal to 1 hour 1544-1618 260 Not required for unplanned events which 0037-0043 100 are less than or equal to 1 hour 2331-2350 400 1125-1149 250 0835-0857 229 0511-0546 608 1557-1603 146 1725-1729 167 1859-1922 2,076 1128-1136 111 1547-1637 139 2107-2201 3,125 0313-0332 363 1420-1436 1,889 TOTAL 9,863 Unplanned Events greater than 1 hour e 9/2/95 9/11/95 9/11/95 9/12/95 9/17/95 9/19/95 9/19/95 9/19/95 9/19/95 9/21/95 9/21/95 9/21/95 9/22/95 9/22/95 Not required for unplanned events which are less than or equal to 1 hour 9/4/95 9/11/95 9/17/95 e 1259-1407 1956-2211 1322-1438 10,625 See Attachments 1,000 See Attachments 344 See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments 11 ,969 See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments TOTAL BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT SEPTEMBER, 1995 1:' !'1'iTi'r'r.1 ~ nI ~ _If;ll.']. :r.t'1"r.111: r.T1'17.:.' ~ III ~ ~I ~:(oi::r::r.l1WJ.illllll"1 r.f Page 2 TOTAL o Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf e TOTAL o TQT~L Unplanned Events < 1 Hour 9,863 Unplanned Events> 1 Hour 11,969 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events > 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 14.476 TOTAL FLARED VOLUME 36,308 REPORT NO: 95-3028 BPX FLARE REPORT PRUDHOE BA V FACILITY: GC-3 DATE: 02 Sap 95 TOTAL VOLUME: 260 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 15:44 TO: 16:18 o Hrs. 34 Mins. 00 D D D 260 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: High LPS pressure due to wells unloading after piggingB-pad LDF. Action Taken to Stop Flaring: Cut gas rate. ~, , If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: REPORT NO: 95-3030 ~ BPX FLARE REPORT PRUDHOE BA V FACILITY: GC-3 DATE: 04 Sap 95 TOTAL VOLUME: 10,625 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 12:59 TO: 14:07 1 Hrs. 8 Mins. 0 00 0 0 10,625 MSCF 2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: K7001 LPS compressor shutdown due to a high pressure shutdown. Action Taken to Stop Flaring: Turbine techs checked the compressor to find the reason for shutdown. It was restarted, inspected, and after no faults found allowed to load. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: .... REPORT NO: 95-3038 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 11 Sap 95 TOTAL VOLUME: 1,500 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 00:37 TO: 00:43 o Hrs. 6 Mins. D 00 D D 100 MSCF 2. FROM: 19:56 TO: 22:11 2 Hrs. 15 Mins. D 00 D D 1,000 MSCF 3. FROM: 23:31 TO: 23:50 o Hrs. 19 Mins. D D D D 400 MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. Overloaded LPS compressors while depressuring Gas Lift supply line for maintenance. 2. Restart GC from total shutdown. There was insufficient gas to restart the LP & IP compressors. 3. Wells unloaded during start-up, overloaded LPS compressor Action Taken to Stop Flaring: 1. Cut LPS gas rate. 2. Brought up GC and restarted compressors. 3. Cut LPS rate and started compressor. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: - REPORT NO: 95-3042 ti BPX FLARE REPORT PRUDHOE BA V FACILITY: GC-3 DATE: 12 Sap 95 TOTAL VOLUME: 250 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 11 :25 TO: 11:49 o Hrs. 24 Mins. D 00 D D 250 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. LP compressors lost suction due to low rates. Assist gas was added to prevent black smoke. Action Taken to Stop Flaring: 1. Rerouted production to establish higher LP gas rate. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: REPORT NO: 95-3050 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 17 Sap 95 TOTAL VOLUME: 573 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 08:35 TO: 08:57 o Hrs. 22 Mins. 00 D D D 229 MSCF 2. FROM: 13:22 TO: 14:38 1 Hrs. 16 Mins. 00 D D D 344 MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mlns. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: High transit pressure due to maint. being performed on L TS at CGF. 2)High transit pressure because of rising ambient temperature and compressors GT-7000 & GT-7001 going on temperature control. . Action Taken to Stop Flaring: BPX cut 93 mmscfpd of gas and ARCO cut 110 mmscfpd. 2)BPX cut 63 mmscfpd and Arco cut 50 mmscfpd. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: REPORT NO: 95-3054 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 19 Sap 95 TOTAL VOLUME: 2,997 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 05:11 TO: 05:46 o Hrs. 35 Mins. 0 IX! 0 0 608 MSCF 2. FROM: 15:57 TO: 16:03 o Hrs. 6 Mins. 0 IX! 0 0 146 MSCF 3. FROM: 17:25 TO: 17:29 o Hrs. 4 Mins. 0 IX! 0 0 167 MSCF 4. FROM: 18:59 TO: 19:22 o Hrs. 23 Mlns. 0 0 0 0 2,076 MSCF 5. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. Due to high transit pressure. _ 2. -3. K-7001 recycle valve opened up due to alarm (E?(haust system Alarm or trouble). 3. -3. K-7001 recycle valve opened up due to alarm (Exhaust system Alarm or trouble). 4. K7001 SID due to bad card. Action Taken to Stop Flaring: 1. ARCO and BOX cut gas rates. 2.-3. Operator hand controlled recycle valve closed and, turbine tech called out to trouble shoot problem. 3-3. Operator hand controlled recycle valve closed and, turbine tech called out to trouble shoot problem. 4. Cut gas rates immediately. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: REPORT NO: 95-3058 BPX FLARE REPORT PRUDHOE BAY FACILITY: GC-3 DATE: 21 Sap 95 TOTAL VOLUME: 3,375 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 11 :28 TO: 11 :36 o Hrs. 8 Mins. 0 00 0 0 111 MSCF 2. FROM: 15:47 TO: 16:37 o Hrs. 50 Mins. 00 0 0 0 139 MSCF 3. FROM: 21 :07' TO: 22:01 o Hrs. 54 Mlns. 0 00 0 0 3,125 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High transit pressure caused by increasing ambient temperature. Ambient temp. increased 7 F. 2. High transit pressure caused by increasing ambient te.mperature. Ambient temp. increased. 3. LPS Compressor K-7001 SID. Action Taken to Stop Flaring: 1. BPX cut 172 mmscfpd and ARCO cut 140 mmscfpd 2. BPX cut 46 mmscfpd 3. PCC cut gas rates (243 mmscfd), LPS Compressor K-7001 re-started. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: REPORT NO: 95-3060 SPX FLARE REPORT PRUDHOE SA V FACILITY: GC-3 DATE: 22 Sap 95 TOTAL VOLUME: 2,252 MSCF I nte rm itte nt Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 03:13 TO: 03:32 o Hrs. 19 Mins. 0 IX] 0 0 363 MSCF 2. FROM: 14:20 TO: 14:36 o Hrs. 16 Mins. 0 IX] 0 0 1,889 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1) High transit gas line pressure. 2) LPS compressor K-7001 sId because of logic problems. Action Taken to Stop Flaring: 1)ARCO I BPX cut gas rates ( 54 mmscfd ). 2) BPX cut 208 mmscfd. BPX shut-in 12 wells. Maint. continues investigation to find root cause for compressor SID's. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: .... ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Field(s) WESTERN OPERATING AREA-PH Facility Operator GATHERING CENTER 3 ARCO ALASKA, INC. Disposition 1. Sold 0 2. Reinjected 0 3. Aared or vented less than 1 hour 13,966 e 2,368 5. Pilot and Purge 20,045 6. Used for lease operations 542,605 7. Other 0 TOTAL items 1 - 7 578,984 8. NGL gas equivalent produced 0 e 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 25,274,125 Remarks: Title: SUPERVISOR *Indicate contribution of each pool to tOIa!. Pool Name Code Percent PRUDHOE 640150 100 Official Use Onlv--Flaring Authorizalion > I hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT AUGUST,1995 Page 1 Unplanned Events less than or equal to 1 hour 8/11/95 1140-1155 104 are less than or equal to 1 hour are less than or equal to 1 hour 8/12/95 0033-1008 3,281 8/18/95 1138-1227 5,750 8/18/95 1332-1345 225 8/18/95 1654-1725 520 8/18/95 1915-1925 1,319 8/18/95 2138-2149 153 8/19/95 0249-0303 875 8/19/95 1611-1626 1,325 8/21/95 0818-0833 275 TOTAL 13,966 1~·~~~;:~::0;;;~~;t:~;:~.::~:~;:~:~~~~~f.t.::::.@::::.:þ€§ÇRt.t:]t.ºNP€'N¢.tº~tft~:ǵ~P. .<::::.:::.::::,..., 8/3/95 1038-1211 350 See Attachments 8/4/95 1900-2110 17 See Attachments 8/9/95 1952-2233 94 See Attachments 8/10/95 1034-1420 1 04 See Attachments 8/10/95 1510-1610 132 See Attachments 8/12/95 0321-0439 118 See Attachments 8/17/95 2132-2400 1 ,336 See Attachments 8/18/95 0000-0403 217 See Attachments TOTAL 2,368 e e t :.§~~'Å~~6h~~~;Êt.!Mt.~ATgÇAq~¡:¡): See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments See Attachments '" BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT AUGUST, 1995 Page 2 1;:;;::;~~l;::;:;~~:;::~;:;§~;:~.:::~~;:;::~~:~~M~;:~r.A;~ª~;:~;'~;~~~:ç:Q~~:~Aº§§::. ......... ... ......... ):mmm:m,Açro.PtÆiA§~~$giºM'"*t§P!4~§~)· TOTAL o .1:z;-:'~;;:w;~¡~=ng1~{~~Q:M=;~~;~=~~9f INCIDENT & CAUSE , ACTION TAKEN TO ELIMINATE CAUSE TOTAL o T9T"L Unplanned Events < 1 Hour 13,966 Unplanned Events> 1 Hour 2,368 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events> 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 20 045 TOTAL FLARED VOLUME 36,379 r-... f"ll..LIII( e e REPORT NO: 95-2990 mi ~ c/ ¿ jlj 5 BPX FLARE REPORT PRUDHOE BAY AI<:;3Ka Vii Ót Gas COliS. t;ommìssion Anchorage FACILITY: GC-3 DATE: 03 Aug 95 TOTAL VOLUME: 350 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 10:38 TO: 12:11 1 Hrs. 33 Mins. 00 D D D 350 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: LPS compressors went on speed control due to transit line pressure increasing and wells unloading. Action Taken to Stop Flaring: Arco shut in 50 mmscfd and BPX shut-in 30mmscfd. Actual flaring time was 42 minutes. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: /Date: I ~, ~LI y' C_ e .. REPORT NO: 95-2993 ~)c/ 2 ì 1995 mi 1-\1~;)I\a Uil & Gas Cons. Commission BPX FLARE REPORT Anchorage PRUDHOE BA V FACILITY: GC-3 DATE: 04 Aug 95 TOTAL VOLUME: 17 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 19:00 TO: 21 :10 2 Hrs. 10 Mins. 00 0 0 0 17 MSCF 2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. Gas Transit line high pressure due to wells unloading. This was two flare occurances that totalled 3minutes. Action Taken to Stop Flaring: 1. Shut in gas from marginal sort with ARCO. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-2999 R t. "'-' ~ < J .Lt If t \ ~c.r' 2 ì i995 BPX FLARE REPORT PRUDHOE BAY laska \.,HI & Gas Cons. Commission FACILITY: GC_3AnCh°f:i\-E: 09 Aug 95 TOTAL VOLUME: 233 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 16:33 TO: 17:15 o Hrs. 42 Mins. 00 0 0 0 139 MSCF 2. FROM: 19:52 TO: 22:33 2 Hrs. 41 Mins. 00 0 0 0 94 MSCF 3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF 5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF CHECK ONE: FLARE/RELIEF VALVE: RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1 . High gas transit line pressure which was caused by rapidly increasing ambient temperatures. 2. High gas transit line pressure while bringing up rate from Annex reboiler sId . Action Taken to Stop Flaring: 1. Reduced LPS gas to GC-3 C-Bank using wells on WOA. 2. Reduced LPS gas to GC-3 C-Bank using wells on WOA. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: e e R ~~ _ L ; \1 t D REPORT NO: 95-3002 ~[¡J 2 ì 1995 BPX FLARE REPORT Alaska LHi & Gas Cons. Commission PRUDHOE BAY Anchorage FACILITY: GC-3 DATE: 10 Aug 95 TOTAL VOLUME: 236 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 10:34 TO: 14:20 3 Hrs. 46 Mins. 00 D D D 104 MSCF 2. FROM: 15:10 TO: 16:10 1 Hrs. o Mins. 00 D D D 132 MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. High gas transit line pressure which caused LP flaring for a total of 15min. intermittently through this incident. 2. LP flared for 19mins. during ambient spikes causing LPS compressors to go to Temp. control. Action Taken to Stop Flaring: 1. ARGO and BPX reduced gas rates to the gas transit line. 2. BP trimmed LP rates. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: e ~"'."' ,'~ ".'. . .,: . r- U . t.. L I v L ;) ':J' ¿ ì 1995 SPX FLARE REPORT PRUDHOE SA V dKä lJiI &. Gas Cons. Commission Anchorage FACILITY: GC-3 DATE: 11 Aug 95 Intermittent TIME OF FLARING: DURATION: Yes No 1. FROM: 11 :40 TO: 11 :55 o Hrs. 15 Mins. 0 00 2. FROM: TO: Hrs. Mins. 0 0 3. FROM: TO: Hrs. Mins. 0 0 4. FROM: TO: Hrs. Mins. 0 0 5. FROM: TO: Hrs. Mins. 0 0 CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: e REPORT NO: 95-3004 TOTAL VOLUME: Black Smoke? Planned? o o o o o o o o o o CONTROLLED BLOWDOWN: 104 MSCF VOLUME 104 MSCF MSCF MSCF MSCF MSCF OTHER: First Determination of Cause: High Slugcatcher pressure due to switching LDF incoming flows from A and B pads for repairs on B bank oil dehydrator. Action Taken to Stop Flaring: BPX trimmed back high GOR wells at GC3 If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: KL e e ",'''' ~' , REPORT NO: 95-3005 - L , "tV 1... _ J ' ~ 0.:_f ¿ ì )995 BPX FLARE REPORT AJé:Ska u¡1 Õt G"s G PRUDHOE BAY d OIìS G ' Anch . ommlssion orage FACILITY: GC-3 DATE: 12 Aug 95 TOTAL VOLUME: 3,399 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 00:33 TO: 01:08 o Hrs. 35 Mins. D 00 D D 3,281 MSCF 2. FROM: 03:21 TO: 04:39 1 Hrs. 18 Mins. 00 D D D 118 MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED SLOWDOWN: OTHER: First Determination of Cause: 1. Odd reboiler SID GC-3 flared per Transit gas dew pt. guide-line. 2. LPS compressors driven to temp control by ambient swing. Total 17 min. Action Taken to Stop Flaring: 1. Odd reboiler back on and up to temp. GC-3 backed out of flare. 2. Trimmed LP wells at GC-3 If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: /Date: I BPX Representative: Yes: No: IDate: e e REPORT NO: 95-3012 R. ~ ~ ; ': [: D I' . mi 2ì 1995 BPX FLARE REPORT ;) ., -' t..! PRUDHOE BAY J.\lc.5Kd VII & Gas Gons. Commission GC-3 Anchor~ 17 Aug 95 FACILITY: DA : TOTAL VOLUME: 1,336 MSCF Intermittent Black TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME 1. FROM: 21:32 TO: 24:00 2 Hrs. 28 Mins. D 00 D D 1,336 MSCF 2. FROM: TO: Hrs. Mins. D D D D MSCF 3. FROM: TO: Hrs. Mins. D D D D MSCF 4. FROM: TO: Hrs. Mins. D D D D MSCF 5. FROM: TO: Hrs. Mins. D D D D MSCF CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: Surging of low pressure compressor K-305 due to cutting oil into GC which reduced gas rates thru the plant. Assist gas was added to low pressure flare to keep from black smoking. Oil rates where cut due to shutting down Wier water injection pump P-7504 for seal repair. Action Taken to Stop Flaring: Added H.P. gas to help increase total L.P. gas rate thru GC, this helped reduce the amount of assist gas need for L.P. flare. Repaired seal on water injection pump P-7504 and increased oil rates into GC. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: IDate: I BPX Representative: Yes: No: IDate: R 1"/ to i. L ~ L '" ,J ') '\ '\995 -..)L! L &i c.SKa UII &. Gas Cons. Commission Anchorage FACILITY: GC-3 e BPX FLARE REPORT PRUDHOE BAY DATE: 18 Aug 95 TIME OF FLARING: 1. FROM: 00:00 TO: 04:03 2. FROM: 11 :38 TO: 12:27 3. FROM: 13:32 TO: 13:45 4. FROM: 16:54 TO: 17:25 5. FROM: 19:15 TO: 19:25 DURATION: 4 Hrs. 3 Mins. o Hrs. 49 Mins. o Hrs. 13 Mins. o Hrs. 31 Mins. o Hrs. 10 Mins. Intermittent Yes No 000 000 000 000 000 CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: e REPORT NO: 95-3014 TOTAL VOLUME: Black Smoke? Planned? o 0 o 0 o 0 o 0 o 0 8,031 MSCF VOLUME 217 MSCF 5,750 MSCF 225 MSCF 520 MSCF 1,319 MSCF CONTROLLED BLOWDOWN: OTHER: First Determination of Cause: 1. This item continues from report 95-3013, Surging of low pressure compressor K-305 due to cutting oil into GC which reduced gas rates thru the plant. Assist gas was added to low pressure flare to keep from black smoking. Oil rates where cut due to shutting down Wier water injection pump P-7504 for seal repair. 2. LPS compressor shutdown due to high temperature shutdown. 3. LPS compressor failed to load on restart. 4. Wells unloaded during ramp-up, and ambient temperature came back up 5 degrees while compressor was shutdown. 5.LPS compressor shutdown due to high temperature shutdown. Action Taken to Stop Flaring: 1. Added H.P. gas to help increase total L.P. gas rate thru GC, this helped reduce the amount of assist gas need for L.P. flare. Repaired seal on water injection pump P-7504 and increased oil rates into GC. 2. Cut approximately 250 MMSCFD gas rate. Controls techs found loose connections in panel. 3. Techs repaired PLC and loaded compressor. 4. Cut approximately 75 MMSCFD to stop flare and reduce transit line pressure. 5. Cut approximately 220 MMSCFD gas rate. Controls techs found more loose connections in panel. If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT? AOGCC Representative: Date: BPX Representative: Yes: No: Date: ~ ÀLÀSKA,(HL ^.l~D pAS CÔNS~RVÅTIO~ COMMISsiöN FACILITY REPORT OF PRODUCED GAS DISPOSITION ..~;" t,J AUG 1 8 1995 Facility GATHERING CENTER 3 Operator ARCO ALASKA, INC. Field(s) WESTERN OPERATING AREA-PH as Cons. CommiSSion chorage . e Disposition 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 1.339 4. Flared or vented greater than 1 hour 4,250 (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 25.278 6. Used for lease operations 507,085 7. Other 0 TOTAL items 1 - 7 537,952 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 24,639,539 Remarks: I """'bv ce:ø the fore...... is true and correct 10 the best of mv knowled... Signature: . ~ Title: SUPERVISOR rorm lU-4:lZ (RevIs '/ e *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100 Official Use Only--Flarin AUlhorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date ote: vo urnes must correc to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ¡ BP EXPLORATION (ALASKA) INC. PRUQHOE BAY UNIT -.GC-3 GAS FLARINq INCIDENT REPORT JULY, 1995 Page 1 e L!J.&J..'1~111II:.I' Events less than or equal to 1 hour :m@tttö.ÄtSf:m:m:m:m:m:miHrrmM¡Wt:r~:r~r:~rrr:r:ttvø.WMê.:mf]rrrÞE$.Øf.jRtlø.fd).f.tl1k3j)êH.ltitºJ.ij$.ttt::::m:t::::t:::::::f~rr:f:r:if:ttrtt\..ø.tlö.HttAkt8ttft.WNi.::ç*ij$.ljjj:¡rrrr::rrm:::m:r~ ··········7iiJ95..···..·······1Ó26~·1Ö32·················.......... ··············1·25r\joÚ~ëëtu¡red·fo¡;·unpianneëi·èVenÙ¡whiCtl··....... ....... ·············Not·¡;ë·qu¡¡;ëd·for unplanned events which 7/6/95 0236-0258 275 are less than or equal to 1 hour are less than or equal to 1 hour 7/8/95 1141-1230 142 718195 1939-2019 222 7/10/95 1525-1529 14 7/17/95 0635-0702 113 7/19/95 0417-0429 125 7/19/95 0504-0516 125 7/20/95 0150-0206 198 " TOTAL 1,339 IUnplanned Events greél,ter thanJ h~ur.._ ... ._.__._ ::~m:::~m:r::PAt§tI:~::I:~::::::::~:::::::::m::::tnMft:::::::::::::::::m::~::::::r:::::::::m:m¥Þ,º.r::::::::r::::::::~:P¡;$.ØRij!D.ø.ffØFl"¢.IQ.~N1rf(ÞAP'$.ijjjj~r::::r:::~:::~::f::::t:::::~::::t::::::::::::r:f*-¢nø.ft::;r~::t(:tJ;QM'ØAj¡:~ÞAø.Hf::fff:~:r::):f:::::j~::::~::: 7/5195 1307-1533 "f25"H¡ghgaš"transit )¡;ës~duetolnëreašë"ämb¡ëiitiëmp"Arooand..BPxëutgasratë·s............. ........................ .. 7/14/95 0337-0900 4,125 Depres. D,P, Y Pad LDF's for IM-3/ine conversion. Finished depressuring D.P, & Y Pad LDF's. TOTAL 4.250 e BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT -..GC-3 GAS FLARING INCIDENT REPORT JULy, 1995 Page 2 IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE TOTAL ACTION TAKEN TO ELIMINATE CAUSE o I e IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL f .~, Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events > 1 hour and exceeding 5,000 MCF e Pilot Purge TOTAL FLARED VOLUME o TOTAL 1,339 4,250 ° - ,. ~ ED f:.. . ¡... I AUG ì 8 \995 I$M ~I~ ~ bas Cons. CommissiQn ~~----- \ AnGbø.rag&. o 25 278 30,867 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION I Facility GATHERING CENTER 3 Disposition 1. Sold 2. Reinjected e 3. Flared or vented less than 1 hour I Operator ARCO ALASKA, INC. 4. Flared or vented greater than 1 hour (Supplemental report rcquired--Sec 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other TOTAL items 1 - 7 8. NGL gas equivalent produced e 9. Purchased gas 10. Transferred from: 11. Transferred to: CCP Remarks: :;r) rT'ì n ,rT1 ~'·'....,.i ""..-. ~........ rn r"") '- 2,556 22,965 524,527 550,724 25,382,017 I hereby certify that the forel!oinl! is true and correct to the best of my knowledl!e. Signature: tJ.~" ~ Title: SUPERVISOR t'orm lO-4~R~ViSed 4/95) I Field(s) J MonthlY ear of Disposition WESTERN OPERATING AREA-PH Jun-95 *Indicate contribution of each pool to total. ° Code Pool Name Percent ° PRUDHOE 100 640150 676 ° Official ÜSeOnly--FlaringAllthorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psi a and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT JUNE,1995 Page 1 e IUnplanned Events less than or equal to 1 hour :::::r:ºÂJ~::~::::::::~:11.M§~\::~::J~~:Yº!;'ºM§::::;:{::Þ§$ÇRIR;m~ijQf!~¢Iº~ff:t~ÇAº$~:::::.:AQ:l1ºtÜrAK!;N;n:)~:;J"'!M!NAT!;ÞAI..J.§f# 6/2/95 0138-0154 167 Not required for unplanned events which Not required for unplanned events which 6/2/95 0418-0425 73 are less than or equal to 1 hour are less than or equal to 1 hour 6/16/95 1033-1116 56 6/18/95 1618-1656 185 6/19/95 1518-1534 69 6/19/95 1832-1856 125 6/21/95 0211-0214 1 TOTAL 676 I.".:.U,:.:,...~:...:._~,:.:,~.,:,..p'::"'.""..D.'.'...a..,'A....,..,n..'.T.,....n,,~......~:.:::..:.,.d::..~:..::..:::.:::.:.E:...::.:.:::.v,:.,:.:.::.:.e...:...:.:...:.:.<,n.::..........,t.::,:.5,..!:n".....,..g......M.......r..E..e......:,.:.a,...::..:,t.,..:...e...:.........r.:.:.:.:.:..:.t..:....h.:....':.:::.a::.:::.::.:.n:...::.:..:.:.,:....:...:1,....,....:..:,..,h0..'.........0...,.,..,.:..'..uu......,'.Mr.........E.........'.' nv "":.QF$ÇR'gT!þNþfINÞmBNr~çAº§!;} 6/6/95 1200-1325 542 High gas transit line pressure. 6/7/95 1148-1438 317 High gas transit line pressure. 6/7/95 1624-2115 375 High gas transit line pressure. 6/15/95 1845-2015 972 High gas transit line pressure. 6/17/95 1003-1115 350 High gas transit line pressure. ............................................ ... ·T· ,. ...... .....". . .... ··:·c···'·' ...................... iAPT!ºNAJS;~·Œ.º~PM'~A[êA\..I§§< Arco & BPX cut gas rates. Arco & BPX cut gas rates. Arco & BPX cut gas rates. Arco & BPX cut gas rates. Arco & BPX cut gas rates. e TOTAL 2.556 s;r ¡r'e, ("') í4l ., ¿ ~1 t"., è":' C? ~ ~ ,,!,~"'" .,." ~~ r;--:. (""':" -,...... ·. , BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT JUNE, 1995 Page 2 I~~:~:~;~~::;:~:~~.:~:~:;:~:~~~..~~~..~~~:~~~o~~..~;~~~;:e~;;;~~~q:q~::~Å4$§~:~~~~..'..:~..:::~.' TOTAL ." 'd, .... ...... .................. .................. ................. .................. .................. .................. . . . . . . . . . . . . . . . . . .... ............. ~))(ACTl()N:iÂKEN'I'().ï;UMINA.TêcÂI.JSE); .............................-....................... ............... .... ........................ ....... ....................................................................................... ..... .... . o IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events > 1 hour and exceeding 5,000 MCF e Pilot Purge TOTAL FLARED VOLUME t~,· ~"... !! i r: { r.... '. } PI!"1 ~~ .. rf1 r-~" "".:--.--' o TOTAL 676 2,556 o o 22 965 26,197 OPERATIONS ID:907-659-4531 JUN 26'95 · BP EXPLORATION (ALAS. PRUDHOE BAV, ALASKA FAX # (907) 659-4531 ".j' l~ lL'~ c. .... Ir,\WJ C" ;,¡C" \\1) 1'-: rj;;) ~.~I,C.(Q)Ir"~\,I ......L [))..~ l,t;:H,.iJ Cr:> II !11~I....r-¡:> ,~ ¡ry.1â.Ù TO: Mr, Blair Wondzell COMPANY: AOGCC LOCA TION : Anchorage 9:16 No.003 P.Ol 6 FAX #: 276-7842 FROM: Bill Broman ~ OPERATIONS PHONE #: 659·4472 LOCATION: PRUDHOE BAY, ALASKA PAGES TO FOLLOW: 1 DATE: 6-26..95 COMMENTS: REßE\VED JUN 2.6 }99S ~ss\O\· AlasJœ. Oil.& Gas Cons. Camm .. ~cborag9 IF YOU DO NOT RECEIVE ALL PAGES, OR HAVE ANY PROBLEMS, PLEASE CALL THE FOLLOWING NUMBER: (907) 659·4528 OPERRTIONS ID:907-659-4531 e JUN 26'95 9:17 No.003 P.02 (ß e .. BP EXPLORATION (ALASKA) INC. P.O, Box 196612, Anchorage AK 99519-6612 REPORT OF ACCIDENTAL NATURAL GAS RELEASE DATE: June 26, 1995 TO: Mr. Blair Wondzell Alaska Oil and Gas Conservation Commission 3001 Porcupine Drive Anchorage, AK 99501 FAX: 276-7542 DESCRIPTION OF INCIDENT ..... 1, Date and Time: ..... Wednesday, 06/21/95, 2:11 AM 2. Location: Detailed L.oç~: L Prudhoe Bay Unit _ Endicott _ Milne Point _ Nlakuk _ Other _3. Voiume of natural g..I~~ . 4. Cause of loss:._. Thro!J9h..~all penetration of Well C-17 choke tail piece 5. Actions taken and planned Choke was repaired. Investigation team looking into further .. ... to prevent furthElr loss:_ opportuníti~s for prevention:.. ..... 6. Equipment or procedural Investigation team will review operating procedures. changes to prevent loss from recurring: 7. Contact (name and telepho'1~ ... numbe r): GC·3 Module 4A Well C·17 choke ... . William H. Broman 907-859-4472 Signature: o/d(.9ðq _ co: BPX Environmental Compllanoe Supervisor MB 11-6 (FAX 564-5020) BPX VDlume Accounting MB 5-4 Production CoordInator Facility Superintendent REQEIVED lJUN 26 }995 NasEa DU& Gas Cons. Comm\Ss\on AnchoraglJ FORM REV 6/96 \... ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION REVISED I Facility GATHERING CENTER 3 Disposition 1. Sold 2. Re~njected e 3. Flared or vented less than 1 hour I Operator ARCO ALASKA, INC. 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other TOTAL item!! 1 - 7 8. NGL gas equivalent produced e 9. Purchased gas 10. Transferred from: 11. Transferred to: CCP Remarks: *"'. t,r 2,840 20,063 27,440 588,682 639,025 ( ( . F-""'''' , J-¡-¡ (") f''1ï "",,-,; J--!'fII. .<t,...... .-~. , t:. ~ r=O) >-.~....--í 27,257,444 I hereþy certify that the forel!:oinl!: is true and correct to the best of my knowledl!:e. Signature: (/ ~ _ rOOD lO-4tZRe~ised 4195;'" . Title: SUPERVISOR I Field(s ) J MonthlY ear of Disposition WESTERN OPERATING AREA-PB May-95 *Indicate contribution of each pool to total. o Pool Name Code Percent o PRUDHOE 100 640150 o OrricialUsc Only--Flaring AUlhorization > 1 hr. 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT MAY, 1995 Page 1 ~.~Ia_~.r.:aed Eve,l!!s, 1~s.!;Jhan orequ,~_IJo 1",~.~..ur ",_ ___,__.___.__u_",_,_.__ ..._ ",___ ,,,_ ¡::If:¡:::¡j:fÞ.ité¡'::t:'II:¡III¡¡¡:¡:¡:::¡:¡jjMi:::¡:¡¡¡¡¡¡It:"IŒIImIŒIMø.tÞ.Mi¡::¡¡:I:::It¡:::Þi$.¢ø.i.!tr~gN::Þf{:jNÞ.tQt¡¡Nr:ltgÂP$.g,I¡¡¡tm¡:¡II:::I¡:'I'ŒI¡¡:I¡¡:¡:I¡¡I¡::I,¡:II:APÍlgN::1ÎKgN.?tø.:¡t.1.MlijA1t;ijt.iøøtm:m¡::¡¡:¡¡¡:¡t::,itII¡:¡I:' 5/2/95 0128-0226 1047 Not required for unplanned events which Not required for unplanned events which 5/3/95 0434-0531 554 are less than or equal to 1 hour are less than or equal to 1 hour 5/3/95 1847-1924 257 5/4/95 0732-0757 217 5/4/95 1553-1624 172 5/30/95 0803-0824 160 e e TOTAL 2,407 ~Unplanned Events areater than 1 hour 5/3/95 2121-2323 1,017 High transit pressure due to L TS SID Arco cut gas 5/4/95 0127-0304 876 High transit pressure Arco cut gas 5/4/95 0447-0638 590 Wells unloading in LP after corrosion inhib. trmt. Switched LP gas to HP 5/9/95 1519-2203 122 Ambient air temperature increased PCC trimmed LPS gas rates. 5/15/95 1637-1744 225 Increased LP gass when switching D-LDF to GC3 BP cut gas 5/23/95 0138-0416 63 D Pad LDF was routed from GC1 to GC3 . Switched LP wells to HP to reduce gas rates 5/23/95 1721-2010 384 D Pad LDF was routed from GC1 to GC3 . Switched LP wells to HP to reduce gas rates 5/24/95 0819-1616 931 High transit pres. due to increasing ambient temp. ARCO and BPX reduced gas rates. 5/24/95 1822-1929 13,500 K7001 LP camp sId due to faulty signals from PCM. Compressor was restarted 5/25/95 0251-0510 90 High LPS gas rates Trimmed LP gas rates. 5/27/95 1101-1211 90 High transit pressure Arco cut gas 5/31/95 1724-1829 900 High transit pressure ARCO and BPX reduced gas rates. TOTAL 20,063 .4 .\\~ t \) \)\rCt. \' ,..,. (\ '\ ç'c\ ( - \"~ "'~ 5/'ZA - tJo...l'M IN ;' 5J'Z,3 - \N~j f:£/?c.JïlJ\::.~ Ð PAù ~ "''''V'~ ""'~J"'''' Ct;\\'\'·'· . ,.:., \lj~s. . ., \;i';"" t"t ." ?r f';\,.\,;'r.o, ' BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT MAY, 1995 Page 2 l~a.~.I)~ "E_vents less Than, or Equal 1 Hour AND, Not.,Ex~~di..ng ,~.oOO..Mc.f.._ , TOTAL .................. ................... 433 ~ ~Planned Events Exceeding 1 Hour OR Exceeding 5.0.0.0 Mct TOTAL e Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events> 1 hour and exceeding 5,000 MCF Pilot Purge TOTAL FLARED VOlUME " .' \) D ,~(t\ \j t. ~ ~.... ~..... , t:, f" t\ ¿ \ . ."è~O~\ '~I"<.¥' ",< r'\r.)\\\~:\\\iJv\ r~r \)U,\'j, .- t~ ..:,ù:.·..~J Þl.nC\1Ûr: . ..... .0 TOTAL 2,407 20,063 433 o 27.440 50,343 .". "Of ...------- MEMORANDUM TO: David JohnstøfÍ. Chairma~ THRU: Blair Wondzell, Æ~ P. I. Supervisor 57r1 Doug Amos~ Petroleum Inspèttor FROM: State of Alaska Alaska Oil and Gas Conservation Commission DATE: May 14.1995 FILE NO: gj9hencd.doc SUBJECT: Gas Release BPX PBU A-Pad Prudhoe Oil Pool Sunday. May 14. 1995: I received a call from Bobby Foster and was informed that there had been a gas release at BPX PBU A-Pad early this morning. I traveled to A-Pad but was denied access due to the evacuation of gas from the module to the atmosphere. I contacted BPX Environmental Specialist Wade Schrok to get the details on what took place. Wade told me that there was a flange gasket failure in the gas lift module which filled the module with gas. There were no injures, no release of oil and no damage to the module. î Wade had no figures on the volume of gas released or the reason for the gasket failure. Wade will be filling an incident report as soon as the area is cleaned up and the assessments are made.' SUMMARY: I conducted a fact finding investigation on the release of gas in the gas lift module at BPX PBU A-Pad. ! J ) t'" (... .7() ;..-- {t!.t:..J . ;~/7..r.J.~ UX'''· I·qv- !L,J. (0'* ~ ,e e 6 "r .,L / Mr. Blair Wondzel M;::ay 17,1995 Page 2 27a~ 7542 1995 17, FAX # May Mr. Blair Wondz(;!1I Alaska Oil and Gas Conservation Commission 3001 PorcLJpi ne Drive Anchorage, AK 99501 Notification of Accidental Loss of Oil or Gas Prudhoe Bay Western Operating Area, A Pad, Skid 56 I The following information is submitted as required by 20 AAC 25.305(b). On May 14,1995, a lifting gas release occurred at Skid 56, A-Pad. in the Prudhoe Bay Western Operating Area. Wade Srock reported the incident verbally to you at approxi mately 0950 hours on May 14, 1995. 1 14th Wondze Time of Incident. A low gas alarm sounded at 0530 hours on May 1995. The release continued for approximately 12 minutes. Mr. Dear n the Prudhoe Bay location. The release occurred at Skid 56 on A Pad, Western Operating Area. 2 that approximately 0.5 million Volume of natural gas lost. BPX estimates cubic feet of gas were released. 3. CaU9é of loss. Failure of a flange gasket on a gas metering device caused depressurization of the gas lift system. The failed gasket was found to have been incorrectly fitted. 4. Actions taken and planned to prevent further loss. All other similar gasket installations within the module were ctlecked. No othar incorrectly fitted gaskets were found. 5. Equipment or procedural changes to prevent loss from rocurring. Proper installation of gaskets should ensure that failures of this type do not occur. An in-depth incident review is focusing on installation procedures for the gaskets, R E C E , V E D 6. CommiS~ji9J! M,4 Y 1 7 199:> dlas~ét.oil &. Gas Cons. ~'chorag, AH 1N3S e SG-l.1-S Ndgt:~1 J1J1II1IIOJ XdH e ðOqpn1d !- 1 #: ~tSL 9L& LOG 1 ñ-f ~ d- Mr. Blair Wondzel May 17,1995 Page 2 rnf:! al 659-4472. you have any questions, please contact If PBU-WOA Sincerely, J:7- rJJ~ ~¿. Garry Meek f - Production Coordinator. Ijm cc: Jack Maddux/Dan Blanchard, Operations Superintendent Janet Platt, BPX ERAD, Anchorage Mary Cocklan-Vendl. BPX ERAD Anchorage Carol KleinJWade Srock, PBU-Envlro Compliance REef VEO , 1 7 & Gas Cons. CommisslQI Anchoraga 1995 MAY Alaska .Oil Á\] .LN3S e £S-L1-9 Nd9t:61 J1JUlUlOJ XdQ e aot{pnJd .... 1 G #:6v£L 9LG LOS ....,*"~ ~. ilL-J.'.>:' ._I.'",,;!I:i::.-:,,1 , . ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator BPX Field(s} WESTERN OPERATING AREA - PBU Disposition Volume MCF'" 1. Sold 0 .einjected 0 3. Rared or vented less than 1 hour 2,969 4. Flared or vented greater than 1 hour 65,183 (Supple""DIaI ~pon requi...4-·S.. 20 AAC 25.235) 5. Pilot and Purge 22,547 6. Us~d for lease operations 537,419 7. Other (Production sent to CCP) 21,227,513 TOTAL 21,855,631 of Disposition "'If production comes from multiple pools, indicate contribution of each pool to total. Pool Percent {(:L/C"" /S 7S~ / C':'. c- Offici'll \J~e OIlI)i,lõlallll ; Alllhori:r.alion> 1 hr, 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF .: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. win the month of dis osition. Authorit 20 AAC 25.253 Remarks: I hereby certify that the foregoing is true and correct to the best Report due by the 20th of the month Signature Title of my knowledge. c:. ,-..d c~ - ., '&0 J,....: 7 Date: --~L 'l ~ /7.5--:- .~ Form 1 ()"4 22 Rev. 11194 . '. . ., BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT APRIL, 1995 Page 1 lunplanned Events less than or equal to 1 hour I tttt:tÞ.ÄÎitt::t:ttmt::tt:IJjMJ¥tttItttttttt:]~º'ºMi.\t:tt~tm:Pj$.ÇfjRD9tH~FJt~¢Ip.iwt:.::çjQ$.Îttt:ttm::::::::ttttmt:::¡~tti::::::Im¡tA¢Tl9t!ttÜgÜttttIt1Mt.NÄTi~:Mº$.§:::::::~:::t::::~t:t:::::rItr:¡:~~ 4/1/95 0326-0341 833 Not required for unplanned events which Not required for unplanned events which 4/10/95 1508-1524 1,000 are less than or equal to 1 hour are less than or equal to 1 hour 4/17/95 1040-1045 35 4/17/95 1252-1254 14 4/19/95 1707-1718 76 4/24/95 0348-0421 779 e 4/28/95 1149-1210 232 TOTAL 2,969 e ~~_.mø1E®'·J~~!!!I!!~~~m.J 4/11/95 1756-1908 133 Depres. header from A pad to gathering center. Gas rates were cut to stop flaring. 4/14/95 1045-1625 563 LP gas was so low that LP compr. surged. Flare pad back in service. 4/15/95 12Q6-2400 593 LP Compr sd due to lack of gas Bring up plant to prod. more gas. 4/16/95 000Q-240Q 2000 LP Compr sd due to lack of gas Bring up plant to prod. more gas. 4/17/95 0º00-05~ 696 LP compressors shutdown due to lack of gas Increased gas rate and started LP compr. ( 4/20/95 0856-1445 10664 K305, K308 SID during bridle work on V336 Started compressors following repairs. .~ 4/20/95 1518-2158 3611 K305,K308 SID during bridle work on V336 Started compressors following repairs. L 4/20/95 2248-2400 650 K305,K308 SID during bridle work on V336 Started compressors following repairs. 4/21/95 ºº01-21 05 40378 IP Compressors and LP Compressors shutdown. Started compressors following repairs. 4/22/95 1130-1329 92 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. 4/24/95 0625-0801 1079 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. 4/25/95 1749-1859 904 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. 4/26/95 0506-0955 1158 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. 4/28/95 0006-0106 340 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. 4/29/95 1750-2134 2169 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates. TOTAL 65,183 11';:¡~'!'ITrTlo;'~'lo I f~~'( .¡o;q')'11 I! .I-:tim ill]:1 ~ t1ir.J.i'!'IIII'j r:; ¡tttttgm¡tt¡t¡¡¡¡¡¡¡t¡¡H¡l¡ttnMjf:~tftMtt¡t¡¡¡¡!¡¡¡¡¡:¥§i.YMj¡ttf¡t¡t¡pg§ÇØä1a~¡gj¡¡W§Im¡,¡¡g4.g§§:!tM¡t~¡t¡tt¡:M¡m::!:!~:¡¡:¡!!:j!!¡j:¡!¡¡¡¡¡¡!!¡"§11.§H¡¡t.~trg¡:gÜMMÎi.¡:þjP.~t¡¡¡:~¡::~¡¡¡¡¡:¡tt¡!¡t¡j:::::¡¡¡:!¡t:¡j: TOTAL o " . .~ . ". e Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events> 1 hour and exceeding 5,000 MCF Pilot Purge TOTAL FLARED VOLUME e BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT APRIL,1995 Page 2 ..:.. :.TQI~~·/ \: 2,969 65,183 o o 22.547 90,699 e e I spoke to Gary Meek at BP on August 10, 1995 about the following events that were reported for April: The most cornmon types of flaring are Ambient temp. (CCP), Reboiler shutdown (skid 18). Transit pressure and ambient temp are almost always intermittent. Gathering Center 1 04/01/95 Skid 18 compressors not loading The compressor at the electric driver is very sensitive when started up and they end up bumping the flare. If this equipment shuts down the whole Gathering Center will shut down. They play with the compressor controls and the recycle valve. They recycle the gas from the outlet to the inlet. If the compressor surges, then the 2nd and 3rd stage will trip out and flare. Skid 18 contains the 2nd stage to IP compressor and the 3rd stage LP compressor. They replaced the computer control systems. A small compressor controls the flow. If they lose the load, then they start to bog down. - Not loading. They suspect the LP were having problems. Sometimes they have to bring on more wells in these situations. 04/01/95 Odd reboiler SID 04/03/95 Even reboiler SID He couldn't tell me exactly what the problem was with the reboiler SID. When events last over 1 hour then they usually have problems with restart attempts. These were continuous flaring events. On the 1 st, they flared a high rate for 15 minutes, they started shutting in wells and flared at a low rate for the next 2 hours. On April 3rd, they routed gas to the flare to avoid shipping wet gas to the transit line. They did reduce rates, but he couldn't tell when. They should have started cutting rates 1/2 hr into the event, at 2309, but they didn't start until 2318. Then they flared 40 more minutes. 04/1 0/95 Took their Odd train contactor offline to repair leak There was a leak on the odd train discharge flow transmitter. They flared offthe slugcatcher. This could have been a gasket leak. They took the TEG pump down, so the gas was no longer dehydrating, so they had to flare. They cut back the slug catcher flare valve to a minimum and cut the gas rates by shutting in several wells. Gathering Center 2 04/02/95 LPS compressors on governor limited 04/16/95"" " 04/19/95"" " This was intermittent flaring. He didn't know if theis was a temperature or speed governor problem. The governor prevents the compressor from going over or under e e range. They tried to speed up the gas rates but the compressor wouldn't take it. They started tweaking backwells. The LPS compressors full safety systems weren't allowing gas in. This is generally caused by having a packed separator upstream. 04/21/95 Excess gas due to cycling wet shutin wells These were high water cut oilwells. The event gave rise to high LP gas rates. They cut back the LP production. The event lasted 4 1/2 hours, but had a total flaring time of 63 minutes. 04/22/95 K205 SID when C bank slugcatcher sid. 04/23/95 LPS flaring bringing up well 04/24195 K7000 LPS compressor shutdown 15:05-24:00 They were having continuous control instrumentation problems. They tried to start K7001 but had a failed attempt. They cut rates by 100 mmscfd by 15:30 so the copus or starter turbine discharge pressure lowers enough to start the motor to start the compressor. They ended up replacing the logic cards and the power supply. K7001 came on between 1500-2400 intermittently. At 23:00 Wand Z pads were shut in to cut the gas 100 mmscfd more. Why weren't the gas rates cut earlier or enough? Ifnot enough gas in the system to start the turbine, then it just won't start. It also can have an effect on other equipment. On 4/25, from 00:50-01:39 the K205 LPS compressor shutdown due to high vibrations. Not enough gas was going through it as a consequence of the previous event. Gathering Center 3 04/14/95 LP gas was so low that LP compressor surged The flare system was diverted to the burn pit for a flare system inspection and repairs to the flare system-tip replacement. They normally use the candles to minimize black smoke events. This flaring causes black smoke because the gas is diverted to open-ended pipes in the burn pit. This gave rise to too little gas in the LP compressor, causing it to surge. Not enough flow causes loading or bogging down. It surges because it doesn't have enough feed and the discharge starts flowing back in. This was an intermittent event from 10:45-16:25, but there was 81 minutes of total flaring. There was a TAPS event, too and they cut to 95% nomination. The root cause was the inspection ofthe GC-3 flare pad, which routed gas to the burn pit. They flared because the LP compressor wasn't loading and had to put the LP gas to flare. If not, they would have had to shut down the entire plant. 04/15-17/95 LP compressor sid due to lack of gas This was a trickling flare over the course of 712 minutes. There was a planned SID of the LPS system on the 16-18th. If the LPS system was shut down, then there isn't enough gas for the LP system. with the TAPS slowdown each producer was cut proportionally. If e e they're cut to 60%, then they will start with the higher gas and oil wells. They want to maintain the most difficult production. Jfthey cut back GC-I and GC-2 more, then they would have to freeze protect miles and miles of lines, since they have the higher water cut wells, so GC-3 feels the brunt of TAPS slowdowns, especially in colder weather. This is a safety and rupture preventative action. This event was either caused by the TAPS slowdown, or by GC-3 maintenance work during the TAPS slowdown. He was unable to tell me for sure. 04/20/95 K305, K308 SID during bridle work on V336 The bridle on V336 had dangerous corrosion. The V336 is a scrubber that comes off of the JP, either the suction or the discharge. No gas rates were cut because they were trying to avoid a total plant shutdown. The bridle is a looped piece of pipe which comes out of the scrubber bottom and goes back in about halfway up. The bridle contains the liquid level. The vast bulk of flaring was done on the 20th, from 9 a.m. to 3 p.m. and from 3 p.m. to 9 p.m. and on the 21 st, from 11 a.m. until midnight. During the event, they had to get rid of the gas (depressure), purge with nitrogen, break the seals and replace the bridle. Then they have to purge it with nitrogen again before they put it back together. They loaded up the other train and they didn't cut rates because both the LP and JP compressors were shutdown. 04/21/95 JP compressors and LP compressors SID This is part of the event mentioned above. . ~ . . ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GA TIJERING CENTER 3 Field(s) WESTERN OPERATING AREA - PBU Disposition Volume MCF'" l. Sold 0 2. Reinjected 0 Aed or vented less than 1 hour 15,611 4. Flared or vented greater than 1 hour 5.362 (Supplomontol roporl øquiml--Soo 20 AAC 2S.23~) 5. Pilot and Purge 19,252 6. Used for lease operations 639,945 7. Other (Production sent to CCP) 26.569,861 TOTAL 27,250,031 MonthlYear of Disposition Mar-95 .., "'If production comes from multiple pools, indicate contribution of each pool to total. Pool Percent . O ' 'icial Use Only-I:laring ^ uthC)rÌ7.at~an> ~ hr. 1. Safety MCF 2. Lease MCF 3. Conserv . Purposes MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month followin2 the month of disposition, Authority 20 AAC 25.253 e-rks: - I hereby certify that the foregoing is true and correct to the best of my knowledge. . Signature F~J3,... i't %~-J~~ 1\-1...>1 Title ...¡J fA-Þ,'sA; ~¿~''''- ... f?..u~ t(L-0~ Date: '111 Lis f- Form 10-422 Rev. 11194 1'\ 't~~!!p' ~',' -:'." · .. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT MARCH, 1995 Page 1 ~~~=-_._-_.~"~.~~~)!!~~~~.~~~~:__,,I 30/95 1300-1308 111 Not required for unplanned events which Not required for unplanned events which 3/10/95 1216-1316 10,167 are less than or equal to 1 hour are less than or equal to 1 hour 3/17/95 2041-2057 167 3/24/95 2226-2246 1,444 3/25/95 1333-1426 336 3/27/95 1647-1700 1,237 3/28/95 1346-1412 2,149 TOTAL 15,611 e ¡unPlanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 3/8/95 0646-0838 413 LPS turbines going into governor control. 3/25/95 0049-0350 1,938 Gas transit line pressure increased 3/25/95 0556-1119 1,682 Gas transit line pressure increased 3/26/95 0411-0805 1,329 High Transit Pressure TOTAL 5,362 ACTION TAKEN TO ELIMINATE CAUSE Sihfted gas rates to unload LPS gas system. ARGO and BPX reduced gas rates. ARGO and BPX reduced gas rates. Trimmed up Gas rates 318 - UP l-A \ W e 3)25' ~i , vVf\~ bvf:J0~ ;; I ZG . " }.J\51f...C 60 \"..0(0 6 --:: -4 .¡. . BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT MARCH, 1995 Page 2 I:~:I:::;~~::;~:~:;::::~::;'§~~:·;:::;~:::::~~~~~M~~:~:~:::;:~~$;;:~~;;;~:~~ç::~~:~Iº§§ff:::::r':::f:rrrr::::::::::i:%f:::::êi~:j;!~H:Î9::~YM!t@I§::P.«I~O::oo TOTAL ................. o ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct e::::::::::::::::::qÎm:%:::::::::::::r:::%i:rln~::·::::::::::::::::::%::%%N19gqM~:::::::::::r::::::::g~§Çfl!B1J9fj9fnHÇJ.þ~fjI:I::Ç~Q$§::rrm/ TOTAL e Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events> 1 hour and exceeding 5,000 MCF Pilot Purge TOTAL FLARED VOLUME f o ................................. ........ ........................ .............. ... - -..... ................................. ..················'··A····....--··;rA· OK··· e··· N°··TO· o··E'···I·Mo.. ·1·..i...·T··· eO··""A··U···SE······ ....................................................... :::::::::::::::::::::: . :,,":I:I~n::::t:·.· .: :. :;::1; ';.:::L; ItM:;:; :;;\i.f;.:...... :;::::::::::;;;:::;:::;::::::::\::::;:;::::::-:::-;.; ......................................................,............................................... . ..................................................................,................................................... o ... .T9TA.L 15,611 5,362 o o 19 252 40,225 e e , I spoke to Gary Meek at BP on July 25, 1995 about the following events that were reported for March: Gathering Center 1 03/22/95 Even reboiler SID, lost TEG in contactors The TEG flows from the top down in the contactor towers. They are operated near flood conditions. A shutdown could be caused by 1) too much gas through contactors, or 2) transit pressure line drops. This is more likely. If CCP lost a machine or if another plant went down. They lost the TEG level. They don't have enough information on it. They probably didn't cut gas rates, it's not documented. 03/25/95 LP compo could not remain online at present rates GC 1, Annex, FS 1, and Ccp had water washes and drill site shutdowns. There was a big plant SID with associated flaring t~ing to balance. Gathering Center 2 03/01/95 SIC flare valve cycling off seat The slugcatcher valve was "popping." The slugcatcher was packed so the valve was lifting intermittently to keep the pressure up. 03/03/95 EWE compo shutdown due to flameout on turbine This compressors supply comes from GC-2. The Eileen West End compressor compresses and injects the gas. Flameout on turbine can be caused by 1) sensors (magic eye) or 2) thermocouples. For the magic eyes the glass can get smokey, causing it to rregister a false flameout. First, the operators try to restart the compressor and secondly, PCC starts to shut in wells. 03/04/95 Increasing ambient temp. High transit line pressure. Arco has higher GOR wells, so they should be shutting in first. This was an intermittent event. Gathering Center 3 03/08/95 LPS turbines going into governor control LPS turbines went into governor control due to inlet heat from snow and ice blockage. The turbine slowed down. They weren't getting enough gas through the separators, so the valves were opening. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GATHERING CENTER 3 Operator BPX Field(s) WESTERN OPERATING AREA - PBU MonthlYear of Disposition Feb-95 Disposition Volume MCF'" 1. Sold 0 Reinjected 0 ': 3. Flared or vented less than 1 hour 0 4. Flared or vented greater than 1 hour 0 (Suppl....ulal report required--See W AAC 25,235) 5. Pilot and Purge 2 1.377 6. Used for lease operations 535.904 (includes øas; lift øas) 7. Other (Production sent to CCP) 23.687.836 TOTAL 24.245,117 "'If production comes from multiple pools. indicate contribution of each pool to total. Pool Percent Official Use Onl y. Flaring 1\l1Ihorizlllion> 1 hr, 1. Safety MCF 2. Lease MCF 3. Conserv. ~urposes MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month lowin the month of dis osition. Authorit 20 AAC 25.253 emarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Title S~ Date: 3.f, ö /~J- . TL--- Form 10-422 Rev. 11194 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT FEBRUARY, 1995 Page 1 Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour I ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL o e ~UnPlanned Events greater than 1 hour DATE " TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL o e RECEIVED MAR 1 4 1995 Alaska Oil & Gas Cons. Commission Anchor~ ,. . BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-3 GAS FLARING INCIDENT REPORT FEBRUARY, 1995 Page 2 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf TOTAL o e Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf TOTAL o ;TRTA)" Unplanned Events < 1 Hour 0 Unplanned Events> 1 Hour 0 Planned Events < 1 hour & not 0 exceeding 5,000 MCF Planned Events> 1 hour and 0 exceeding 5,000 MCF e Pilot Purge 21.377 TOTAL FLARED VOLUME 21,377 RECEIVED ìv1AR 1 4 1995 Alaska Oil & Gas Cons. Commission Anchorz · '" ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility GA TIlERING CENTER 3 Operator BPX Field(s) WESTERN OPERATING AREA - PBU MonthlYear of Disposition Jan-95 Disposition Volume MCF'" 1. Sold 0 Reinjected 0 3. Flared or vented less than I hour 2,825 4. Flared or vented greater than 1 hour 2,277 (Supplemental reporl required..See 20 AAC 25,235) 5. Pilot and Purge 19,346 6. Used for lease operations 630,738 (includes gas lift gas) 7. Other (Production sent to CCP) 37,866,428 TOTAL 38,521,614 "'If production comes from multiple pools, indicate cont!Í~!lti.Q.~ each pool to total. ./.~ Pool / - - .~ ~ Percent I \ \ I \ \ \ \ \ \ \ ~ /' Official· Use Only-Flaring Authorization> I hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Note: All volumes must be corrècted to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month llowin the month of dis osition. Authorit 20 AAC 25.253 Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. ~ Signature Title J Form 10-422 Rev. 11/94 RECEIVED FEB 22 1995 Alaska Oil & Gas C Anchor~n~,' Commission Date: ~/?~ 1 FEB 06 '95 10:50AM BP EXPLORATION TAX . DIdII 111ath 1/17186 11221D5 1~ 11241II5 1/2eIDS 1131/95 To'" leg. .. &rid. TII'II" DulaUøn 2209-2220 1161-1227 1 518-1 $U 171.17!58 OD02-OOS1 *5-0718 097000918 $1:1I. ea (b1) P.4/4 AOGCC Gas Flaring & Venting Incident Report Gt-3 o.te 111WitS 111'1tIS 1/17/96 Tall! .-.n Z Unplanntd eventt !Jrater tilt" 1 !lOur _ 6. End. TII1I. DInIIøn 0030?072O 0S28-ð14S ¡gœ.2153 >1"r Volum Met SIlO CKI4 1,083 20m OOR Rlpo~ 'an t - Unplanned _ntI not exceeCIl"I 1 !lOur cUll' Vllfum. Mal 153 2a6 .ce 550 760 542 535 I.N $dI. 82 (lIS) Pin 3 PIM::::::(I~ 1 h_:~~uwediIlllSODO Mat DteI Dutlllon Mal Total Sell. S2 (\14) PI114 PIIftnICI ewnts UCMdlnsJ1 hour OR RCMdlng 5000 Mc:f I AOGÇC GIll fJUIn9 .. vonan,lncident At'*' !eG. .. end. TImes c111r ,.111f Da DurItIon Volumes Durltion Vol .tho... lIat )0 t hour Mar 10'" Sch. Ða (be) 0 0 AOOCC Apt LIn. S <lhr 2.825 u...b1hr 20m AOGCC FIpt Une 5 P." PUrge SCI'I. 82 (b2) 19.34$ u... , ContlnuauS AssiSt Sch. B2 (b5) 0 PeIcrIptlon or Inold..... 6. Cau.. Unloading well lO..eonø stage. HlgII TransR nn. p.....ure CGF 11885 lid for malnL Hgh TrlNJt 11n. pfMaure OGF '1885 sid for main!. Dnarip1lon at InatdelllS .. c.lI$e Deacrlp1Ian at incidents .. Cøø COR Reponing (1) PnJ·authorlzadon requlr8d foe' naring Ind V8I'I1Ing wh.n tHUl1la wen belalllregularprcducdon (b1) (b2) (b3) (b4) (b5) (be) (e) !merJDp Up <11 No Tax p~u. 11I0 TalC Em.~1 NaTali prill!.. <11&<5000 No Tax IIIClSØ8N. 1.e8.. No TalC AulPlorlZlld fix Unau1h.NIule Tu/Penally FEB 6'95 11:47 2,828 Iii'" 2PT o o o e 9075644094 e AcIIon Te,*, to EJimiRatw c.... SWildted _u blck to ""I.lage. Area anø ' IX $/IuNR Gas rats AICO and EIpJt Ilwt-ln a.. TII1II Action TIn.. to I!Ilmlna19 C.... Action TlIC8rI \Q Eliminll18 C.UIMI PAGE. 004 I spoke to John Hal Tucker at BP on June 12, 1995 about the following events that were reported for January: Gathering Center 1 01/15/95 Odd and even reboiler shutdown The reboiler boils gas and oil. If the reboiler shuts down water condenses and they have 3 choices. They can send the gas to CGF. It would freeze in the inlets and this would cause the whole field to shutdown. They can flare it. They can shut dow their facility, causeing a loss in production, This is a rare occurrence and it's extremely rare for both of the reboilers to shut down at the same time. Gathering Center 2 01/02/95 High transit line pressure from higher ambient temperature. This was an intermittent problem. 01/17/95 01/18/95 High gas line pressure due to CGF 1885 off-line These events were both intermittent as well. They run close to the flaring point and have a counter which counts the minutes a flare valve is open. They have cameras at the facilities but only look at them for the black smoke, Cameras are not in production control center and they are the ones who make the decisions to cut production. I asked if hey were notified beforehand of the compressor problem and he said he didn't know, but that Arco and BP have very good fieldwide communication. Gathering Center 3 01/1 0/95 Unloading well to second stage This was also another intermittent event. When a well is shut-in it loads with fluid. The pressure drops 150-300 psi. If a well wont flow to the surface they can get the well into its own line and get it to go to 2nd stage - 35 psi. then it would flow enough to get the load fluid out. This doesn't happen very often and there is no gas lift on that particular pad. e e