ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
ARCO ALASKA, INC.
MonthN ear of Disposition
Dec-95
e
Disposition
1. Sold 0
2. Reinjected 0
3. Aared or vented less than 1 hour 9.832
4. Aared or vented ~reater than 1 hour 0
(Supplemental report required-oSee 20 MC 25.235)
5. Pilot and Pur~e 13.522
6. Used for lease operations 615.283
7. Other 0
TOTAL items 1 - 7 638.637
y;. ,,~
~~. '~'.
8. NGL ~as equivalent produced ;¡-p é/ \; , 0
\þ )7_ '{
"Q , {\.
9. Purchased ~as ~t.:¡t, .... ~"'...,) 0
ç~"~~ "..l ¿""-!
?~ <;;..1- ~ \~ti '-
10. Transferred from: ~ 'qi 0
c> (") Ö
~; (]I
~f¿
11. Transferred to: CCP 61 28.225.926
í:l
::
Rem:lrb:
T herehv certifv that. the foregoing i~ tme ami mrrect to the he~t ofmv knowlerlge.
Signature: Þ4. - Title: SUPERVISOR
Form llLLI"" ~!-1evlsed 4Nj)
e
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 100
Official Use Only--Flarin' Authorizalion > 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
DECEMBER,1995
Page 1
e
Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT a CAUSE
12/6/95 0209-0244 365 Not required for unplanned events which
12/6/95 0426-0517 417 are less than or equal to 1 hour
12/6/95 1317-1328 115
12/7/95 1802-1855 550
12/9/95 1632-1700 219
12/10/95 1125-1216 2,833
12/11/95 0313-0333 500
12/11/95 0840-0907 656
12/11/95 1249-1259 174
12/13/95 0154-0243 1,360
12/17/95 0302-0312 67
12/19/95 1817-1841 150
12/19/95 2218-2258 2,056
12/27/95 1750-1810 278
12/29/95 1437-1511 92
TOTAL 9,832
~ Events greater than 1 hour
:¡/:¡:¡/:::tÞ.4n;::::t'/'¡'::f::::¡:¡::::/::::::ttlMittt¡//::/:::¡::::/,t://v9lÞli::tt::::¡m:'¡:tÞi$.ÇijOjJJQN::,Qf{!N9jQINlfj:¢iÞ.U:ttttftt::t::¡,:::,,//t:::¡:¡:¡:¡:f::f::ttl¢Ðº,ttÄK§N:::tQ::iwMmA'î§:p4Q$.g:f:/:/¡:::¡::::::::¡:tfft::¡:/
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
o
e
¡'of"
',~
~'¡"'"
"-,q,."
'" V4 b '? ¡f",,?,
~:'''' 'f ¡ ~'" 'l,)
"~,ts 0/ , ? 'f;,J
/1 Æ ,,,\ ¡':J"
~ 5..'t.<")... ~. t./L\
",·t;¡"ìfß" v""u
"0Cj¡ "Of'} N
liO;; 'Ò, r'!
$,7"" ....t)';,,,,.
~''"' '''·''1
-¥·/¡';;3"'·
lOll
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
DECEMBER,1995
Page 2
r.Jr.":rr.Tl";~..,.»t~J es. Than or Eaual1 Hour AND Not Exceedlna 5000 Met I
fmrm:r::þ.i.ti.:::::::::tfffff:r:j::IÎ!M$.mf::j:j:::f:::::::{:::::::m::m::j:}lgMi:fmrmfffÞil«mPDQN.mQfJNÞ!Þøt::.j:Þ.Â.::::::::::::::tjIIr::r:::::::::::::::::::::::j::t:f::::fm:¡::¡UØNltjØtUttflbwHÄm:«iij$.i::t¡::::::::m:::::::::m¡¡:¡:::¡:¡:::¡:¡:¡r:¡:
TOTAL
o
Planned Events Exceeding 1 Hour OR Exceeding 5000 Met
e
:¡:fmm::::m:PAtlfIfmrrm:::::r::::::rtt!Mifffff¡rrr:f:::::::r:¡YQþjjl¡:j:t¡:t¡::::mm:ÞiømêñgÑ¡:Qf]H«GiH:Þí.::QAø.H:¡:¡:t¡r:j:¡:::::::::m:::::mrrf:::::::¡:::::::::¡::r:tffiWø.jJt."jU~N/tQ::è.ÞMWÄjjtÞAø.$.$.:m:j:¡r::::::::::::::::r:::::::j:j::::m:::::::
TOTAL
o
TOTAL
Unplanned Events < 1 Hour 9,832
Unplanned Events> 1 Hour 0
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 13.522
TOTAL FLARED VOLUME 23,354
. \¡ ~;,;O
..'; ,~... \ ... i6-
.""," ,,' 'f. .~_
( ";;. ìi..- ........
JP-." '\ 1 1~SS
I"N'lIf\ÚSS\on
r·('\·~S V·;,.;>'\·
,."\ ~ Ga~) ~,V" .
'''aO' .~ ~ e
N,¡)'t:;,- " þ..."Ic\\û!ag
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
ARCO ALASKA. INC.
Field(s) Month!Year of Disposition
WESTERN OPERATING AREA-PH Nov-95
e
Disposition
1. Sold 0
2. Reinjected 0
3. Aared or vented less than 1 hour 3.915
4. Aared or vented ,greater than 1 hour 12.990
(Supplemental r uired--See 20 AAC 25.235)
5. Pilot and Purge 12.062
6. Used for lease operations 593.458
7. Other 0
TOTAL items 1 - 7 622.425
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: 0
11. Transferred to: CCP 26.747.501
Remarks:
T herehv cert.ifv that the foregoing i~ tme anct corrf'.ct to the he~t of mv knowlf'.rlve.
-:{- "
Signature:._j/ L:)~.;,~..-;.,.,--- Title: SUPERVISOR
Form 1O~ (RevIsed 4195)
e
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 100
OtliculllJsc Only--Flurin Allthorizutinn > 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
NOVEMBER,1995
Page 1
Unplanne.!t~Y..!t_l.:'ts less than or equal to 1 hour I
:::::::t:::tH>.,mm::::::':::::::::::::::::::::::::¡::::¡¡:ttlj::::::::::t¡::::::::::::::tt::::::':ttf.øijQI::::'::::t::¡::¡ttQ~mgnº":¡ºf:'W~P'ijijl::.]MQØ::::t::¡¡:::¡::¡¡::::t:t::t¡:'::::::::::::::::t:¡::::::::¡::¡:t:::':'.Qitt."I¡N::Tq::iQï.ÎN.AtI:çiy.iiI¡:~'i';8m::::::::::¡:::'::::::::¡%:
11/4/95 1630-1653 413 Not required for unplanned events which Not required for unplanned events which
11/9/95 0844-0901 213 are less than or equal to 1 hour are less than or equal to 1 hour
11/17/95 0531-0614 299
11/17/95 1657-1711 194
11/17/95 1825-1918 264
11/18/95 0706-0725 238
11/23/95 2342-2359 354
11/24/95 0001-0022 438
11/26/95 0104-0153 688
11/26/95 2330-2358 397
11/27/95 0220-0245 417
TOTAL 3,915
e
Un .Ianned Events ! rester than 1 hour
DATE
11/10/95
11/20/95
11/24/95
11/27/95
11/28/95
e
TIME
1255-2345
0740-1218
2036-2211
0427 -0550
2029-2208
TOTAL
VOLUME DESCRIPTION OF INCIDENT a CAUSE
8,855 See Attachments
1,062 See Attachments
1 ,469 See Attachments
271 See Attachments
1 ,333 See Attachments
12,990
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
RECEIVEU
orc 1 8 1995
Alaska Oil & Gas Cons. Commission
Anchorage
~
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
NOVEMBER, 1995
Page 2
r.J(:('rrrl"!.~...n.t~J !'Á.Á._T;hfW..lV-FlV~AI1 Hour AND Not ExceedlnaJ)~O M.C?' ,_ 1
¡::::'::::::ff:'Atlif:{:¡:¡::::¡¡:¡:::¡{mmm'{TIMI{{m:mf"¡:f¡'f¡:¡:¡:fffl<Nae.::::m::::::¡:f':¡:m:þgJ.QflOtnºrifpf:1H.Ç~Þe.~1\1::çi.ºe:{{{{mf::::"::¡':::::::::¡::::¡:::i¡::{::{m::::::::¡:::f¡iggN.:tå.:l!tø::éYMÎiÂi.i.E:çi.ت~tt::¡::{:::f::¡:¡:¡:::¡::::::'ff::::¡:
TOTAL
o
~~~ITrrl"!.~....w~Jxceedln(l1 Hour OR Exeeedlna 5000 Mef ._ ".___ ",,_ .__ "_..._ I
o
TOTAL
TOTAL
Unplanned Events < 1 Hour 3,915
Unplanned Events> 1 Hour 12,990
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 12 062
TOTAL FLARED VOLUME 28,967
e e
REPORT NO: 95-3107
Ej BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 10 Nov 95 TOTAL VOLUME: 8,855 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 12:55 TO: 23:45 10 Hrs. 50 Mins. D 00 D D 8,855 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. LP compressors and TEG regeneration system shut down because of a power failure at GC-3. The loss of the LP
compressors resulted in the flaring of all third stage separator gas.
2.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX began cutting rates at 1300 hours while GC-3 technicians identified the cause of the power failure. The initial gas
cut totalled 450 mmscfd. Assist gas was added to the flare to prevent black smoke flaring.
2. At 1400 hours, it was reported that the power failure was the result of significant damage to circuits and power would not
be returned for an unspecified length of time. BPX immediately reduced gas rates to the minimum (475 mmscfd) to
insure that production lines were not subject to freezing. Assist gas was continued to prevent black smoke.
3. At 2345 hours, the GC-3 electrical system was repaired and the LP compressors were returned to service.
4.
5.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3112
Ei BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 20 Nov 95 TOTAL VOLUME: 1,062 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 07:40 TO: 12:18 4 Hrs. 38 Mins. D 00 D D 1,062 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. It was observed that the flare header pressure was gradually increasing from an unknown source. The flare valves
indicated close.
2.
3.
4.
5.
Action Taken to Stop Flaring:
1. Operations personnel dicovered during a thorough search that an LPS compressor discharge psv, located outside on
an overhead piperack, had failed and was leaking into the flare header. The spare was put in service and the leaking psv
was isolated. A sensing line on the psv was found to be faulty.
2.
3.
4.
5.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3116
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 24 Nov 95 TOTAL VOLUME: 1,907 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:01 TO: 00:22 o Hrs. 21 Mins. D 00 D D 438 MSCF
2. FROM: 20:36 TO: 22:11 1 Hrs. 35 Mins. 00 D D D 1,469 MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High gas transit line pressure caused by GGF compressor problems due to Boosters slowing down
High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
+9°F.
2. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
+12F.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX reduced production rates and shut-in 5 wells equaling 129 mmcfd. ARGO reduced production rates and shut-in
wells equaling 80 mmcfd. Wells were shut-in or choked back starting at 23:52 hours.
2. BPX reduced production rates and shut-in 10 wells equaling 243 mmcfd. ARGO reduced production rates and shut-in
wells equaling 234 mmcfd. Wells were shut-in or choked back starting at 1857hours.
3.
4.
5.
RECEIVi::U
OEC 1 8 "95
Alaska Oil & Gas Cons. Commission
Anchorage
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3121
mi BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 27 Nov 95 TOTAL VOLUME: 688 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 02:20 TO: 02:45 o Hrs. 25 Mins. 0 IX] 0 0 417 MSCF
2. FROM: 04:27 TO: 05:50 1 Hrs. 23 Mins. IX] 0 0 0 271 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
+7°F.
2. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
+11°F.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX reduced production rates and shut-in 4 wells equaling 104 mmcfd. ARGO reduced production rates and shut-in
wells Wells were shut-in or choked back starting at 02:27 hours.
2. BPX reduced production rates and shut-in 3 wells equaling 66 mmcfd. ARGO reduced production rates and shut-in
wells Wells were shut-in or choked back starting at 05:15 hours.
3.
4.
5.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3125
.
Ei BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 28 Nov 95 TOTAL VOLUME: 1,333 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 20:29 TO: 22:08 1 Hrs. 39 Mins. IX] 0 0 0 1,333 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by
+16F.
2.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX reduced production rates and shut-in 9 wells equaling 229 mmcfd. ARCO reduced production rates and shut-in
wells. Wells were shut-in or choked back starting at 20:28 hours.
2.
3.
4.
5.
RECEIVt::u
OEC 1 8 1995
Alaska Oil & Gas COns. wnmission
Anchorage
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
ARCO ALASKA, INC.
Field(s) MonthN ear of Disposition
WESTERN OPERATING AREA-PB Oct-95
1. Sold
o
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 100
Disposition
2. Reinjected
o
3. Aared or vented less than 1 hour
12,252
e
575
5. Pilot and Purge
11,770
6. Used for lease operations
599,603
e
9. Purchased gas
i.. ~. L... ~ \I t...
o
........-...-
Official U~ OJlly--Flllrin AUlhorilation> 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
7. Other
o
TOTAL items 1 - 7
624,200
8. NGL gas equivalent produced
o
10. Transferred from:
o
11. Transferred to: CCP
Anchorage
26,915,633
Remarks:
I hereby certify tbat the forel!oÍßI! is true and correct to the best of my knowledl!e.
I
/ (r /L._') _,_~_--- Title: SUPERVISOR
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
OCTOBER, 1995
Page 1
e
Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
10/2/95 0156-0228 4,889 Not required for unplanned events which
10/10/95 1413-1500 5,940 are less than or equal to 1 hour
10/12/95 1216-1314 960
10/12/95 1529-1534 80
10/30/95 2205-2251 383
TOTAL 12,252
~Unplanned Events greater than 1 hour
;:D~rE i, '. TIME ;, VOLUME DESCRIPTION OF1NCIDENT & CAUSE
10/16/95 1621-1742 575 See Attachments
TOTAL 575
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
ACTION TAKEN Tº~UMINATE CAUSE
Not required for unplanned events
are less than or equal to 1 hour
e
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
OCTOBER, 1995
Page 2
Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
DATE TIME VOLUME DESCRIPTION OF INCìDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
o
e
Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
..;: "ATE·! ... TIME· VOlUME ... ·OESCRIPTlONOFINCIQ!;~ & CAUSE
.. AÇ:'TIQN TAKEN :rOELlMINATJ; CAUS~
TOTAL
o
Unplanned Events < 1 Hour 12,252
Unplanned Events> 1 Hour 575
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 11 ,770
TOTAL FLARED VOLUME 24,597
e e
REPORT NO: 95-3074
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 16 Oct 95 TOTAL VOLUME: 575 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 16:21 TO: 17:42 1 Hrs. 21 Mins. IXI D D D 575 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High Transit pressure caused by wells unloading that were brought on following CCP compressor #1809 start-up.
2.
3.
4.
5.
Action Taken to Stop Flaring:
1. BPX cut1 00 mmscfd starting at 17:00
2.
3.
4.
5.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: ¡Date: I BPX Representative:
Yes: No:
IDate:
ALASKA OIL AND GAS CONSERV A TION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
ARCO ALASKA, INC.
Field(s)
WESTERN OPERATING AREA-PB
e
Disposition
1. Sold 0
2. Reinjected 0
3. Aared or vented less than 1 hour 9,863
4. Aared or vented greater than 1 hour 11,969
(Supplemental report required-See 20 AAC 25.235)
,
5. Pilot and Purge 14,476
6. Used for lease operations 519,202
7. Other 0
TOTAL items 1 - 7 555,510
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred úom: 0
11. Transferred to: CCP 23,465,513
Remarks:
I berebv the fores!Oiol! is true and correct to the best of mv knowledl!e.
Signature~~~ Title: SUPERVISOR
t'orm IIJ-4;¿;¿ {Kevl "
e
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 100
, '.. --..-.
OJ1iciul Use Oll!r--Flllrin , Auth~)rilali()n > ] hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
SEPTEMBER, 1995
Page 1
I
Unplanned Events less than or equal to 1 hour
1544-1618 260 Not required for unplanned events which
0037-0043 100 are less than or equal to 1 hour
2331-2350 400
1125-1149 250
0835-0857 229
0511-0546 608
1557-1603 146
1725-1729 167
1859-1922 2,076
1128-1136 111
1547-1637 139
2107-2201 3,125
0313-0332 363
1420-1436 1,889
TOTAL 9,863
Unplanned Events greater than 1 hour
e
9/2/95
9/11/95
9/11/95
9/12/95
9/17/95
9/19/95
9/19/95
9/19/95
9/19/95
9/21/95
9/21/95
9/21/95
9/22/95
9/22/95
Not required for unplanned events which
are less than or equal to 1 hour
9/4/95
9/11/95
9/17/95
e
1259-1407
1956-2211
1322-1438
10,625 See Attachments
1,000 See Attachments
344 See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
11 ,969
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
TOTAL
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
SEPTEMBER, 1995
1:'!'1'iTi'r'r.1 ~ nI ~ _If;ll.']. :r.t'1"r.111: r.T1'17.:.' ~ III ~ ~I ~:(oi::r::r.l1WJ.illllll"1 r.f
Page 2
TOTAL
o
Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
e
TOTAL
o
TQT~L
Unplanned Events < 1 Hour 9,863
Unplanned Events> 1 Hour 11,969
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events > 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 14.476
TOTAL FLARED VOLUME 36,308
REPORT NO: 95-3028
BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-3 DATE: 02 Sap 95 TOTAL VOLUME: 260 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 15:44 TO: 16:18 o Hrs. 34 Mins. 00 D D D 260 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High LPS pressure due to wells unloading after piggingB-pad LDF.
Action Taken to Stop Flaring:
Cut gas rate.
~,
,
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
REPORT NO: 95-3030
~ BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-3 DATE: 04 Sap 95 TOTAL VOLUME: 10,625 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 12:59 TO: 14:07 1 Hrs. 8 Mins. 0 00 0 0 10,625 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
K7001 LPS compressor shutdown due to a high pressure shutdown.
Action Taken to Stop Flaring:
Turbine techs checked the compressor to find the reason for shutdown. It was restarted, inspected, and after no
faults found allowed to load.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
....
REPORT NO: 95-3038
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 11 Sap 95 TOTAL VOLUME: 1,500 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:37 TO: 00:43 o Hrs. 6 Mins. D 00 D D 100 MSCF
2. FROM: 19:56 TO: 22:11 2 Hrs. 15 Mins. D 00 D D 1,000 MSCF
3. FROM: 23:31 TO: 23:50 o Hrs. 19 Mins. D D D D 400 MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Overloaded LPS compressors while depressuring Gas Lift supply line for maintenance.
2. Restart GC from total shutdown. There was insufficient gas to restart the LP & IP compressors.
3. Wells unloaded during start-up, overloaded LPS compressor
Action Taken to Stop Flaring:
1. Cut LPS gas rate.
2. Brought up GC and restarted compressors.
3. Cut LPS rate and started compressor.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
-
REPORT NO: 95-3042
ti BPX FLARE REPORT
PRUDHOE BA V
FACILITY: GC-3 DATE: 12 Sap 95 TOTAL VOLUME: 250 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 11 :25 TO: 11:49 o Hrs. 24 Mins. D 00 D D 250 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. LP compressors lost suction due to low rates. Assist gas was added to prevent black smoke.
Action Taken to Stop Flaring:
1. Rerouted production to establish higher LP gas rate.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
REPORT NO: 95-3050
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 17 Sap 95 TOTAL VOLUME: 573 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 08:35 TO: 08:57 o Hrs. 22 Mins. 00 D D D 229 MSCF
2. FROM: 13:22 TO: 14:38 1 Hrs. 16 Mins. 00 D D D 344 MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mlns. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
High transit pressure due to maint. being performed on L TS at CGF.
2)High transit pressure because of rising ambient temperature and compressors GT-7000 & GT-7001 going on
temperature control.
.
Action Taken to Stop Flaring:
BPX cut 93 mmscfpd of gas and ARCO cut 110 mmscfpd.
2)BPX cut 63 mmscfpd and Arco cut 50 mmscfpd.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
REPORT NO: 95-3054
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 19 Sap 95 TOTAL VOLUME: 2,997 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 05:11 TO: 05:46 o Hrs. 35 Mins. 0 IX! 0 0 608 MSCF
2. FROM: 15:57 TO: 16:03 o Hrs. 6 Mins. 0 IX! 0 0 146 MSCF
3. FROM: 17:25 TO: 17:29 o Hrs. 4 Mins. 0 IX! 0 0 167 MSCF
4. FROM: 18:59 TO: 19:22 o Hrs. 23 Mlns. 0 0 0 0 2,076 MSCF
5. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Due to high transit pressure. _
2. -3. K-7001 recycle valve opened up due to alarm (E?(haust system Alarm or trouble).
3. -3. K-7001 recycle valve opened up due to alarm (Exhaust system Alarm or trouble).
4. K7001 SID due to bad card.
Action Taken to Stop Flaring:
1. ARCO and BOX cut gas rates.
2.-3. Operator hand controlled recycle valve closed and, turbine tech called out to trouble shoot problem.
3-3. Operator hand controlled recycle valve closed and, turbine tech called out to trouble shoot problem.
4. Cut gas rates immediately.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
REPORT NO: 95-3058
BPX FLARE REPORT
PRUDHOE BAY
FACILITY: GC-3 DATE: 21 Sap 95 TOTAL VOLUME: 3,375 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 11 :28 TO: 11 :36 o Hrs. 8 Mins. 0 00 0 0 111 MSCF
2. FROM: 15:47 TO: 16:37 o Hrs. 50 Mins. 00 0 0 0 139 MSCF
3. FROM: 21 :07' TO: 22:01 o Hrs. 54 Mlns. 0 00 0 0 3,125 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High transit pressure caused by increasing ambient temperature. Ambient temp. increased 7 F.
2. High transit pressure caused by increasing ambient te.mperature. Ambient temp. increased.
3. LPS Compressor K-7001 SID.
Action Taken to Stop Flaring:
1. BPX cut 172 mmscfpd and ARCO cut 140 mmscfpd
2. BPX cut 46 mmscfpd
3. PCC cut gas rates (243 mmscfd), LPS Compressor K-7001 re-started.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
REPORT NO: 95-3060
SPX FLARE REPORT
PRUDHOE SA V
FACILITY: GC-3 DATE: 22 Sap 95 TOTAL VOLUME: 2,252 MSCF
I nte rm itte nt Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 03:13 TO: 03:32 o Hrs. 19 Mins. 0 IX] 0 0 363 MSCF
2. FROM: 14:20 TO: 14:36 o Hrs. 16 Mins. 0 IX] 0 0 1,889 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mlns. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1) High transit gas line pressure.
2) LPS compressor K-7001 sId because of logic problems.
Action Taken to Stop Flaring:
1)ARCO I BPX cut gas rates ( 54 mmscfd ).
2) BPX cut 208 mmscfd. BPX shut-in 12 wells. Maint. continues investigation to find root cause for
compressor SID's.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
....
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Field(s)
WESTERN OPERATING AREA-PH
Facility Operator
GATHERING CENTER 3 ARCO ALASKA, INC.
Disposition
1. Sold 0
2. Reinjected 0
3. Aared or vented less than 1 hour 13,966
e
2,368
5. Pilot and Purge 20,045
6. Used for lease operations 542,605
7. Other 0
TOTAL items 1 - 7 578,984
8. NGL gas equivalent produced 0
e 9. Purchased gas 0
10. Transferred from: 0
11. Transferred to: CCP 25,274,125
Remarks:
Title: SUPERVISOR
*Indicate contribution of each pool to tOIa!.
Pool Name Code Percent
PRUDHOE 640150 100
Official Use Onlv--Flaring Authorizalion > I hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
AUGUST,1995
Page 1
Unplanned Events less than or equal to 1 hour
8/11/95 1140-1155 104 are less than or equal to 1 hour are less than or equal to 1 hour
8/12/95 0033-1008 3,281
8/18/95 1138-1227 5,750
8/18/95 1332-1345 225
8/18/95 1654-1725 520
8/18/95 1915-1925 1,319
8/18/95 2138-2149 153
8/19/95 0249-0303 875
8/19/95 1611-1626 1,325
8/21/95 0818-0833 275
TOTAL 13,966
1~·~~~;:~::0;;;~~;t:~;:~.::~:~;:~:~~~~~f.t.::::.@::::.:þ€§ÇRt.t:]t.ºNP€'N¢.tº~tft~:ǵ~P. .<::::.:::.::::,...,
8/3/95 1038-1211 350 See Attachments
8/4/95 1900-2110 17 See Attachments
8/9/95 1952-2233 94 See Attachments
8/10/95 1034-1420 1 04 See Attachments
8/10/95 1510-1610 132 See Attachments
8/12/95 0321-0439 118 See Attachments
8/17/95 2132-2400 1 ,336 See Attachments
8/18/95 0000-0403 217 See Attachments
TOTAL 2,368
e
e
t
:.§~~'Å~~6h~~~;Êt.!Mt.~ATgÇAq~¡:¡):
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
See Attachments
'"
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
AUGUST, 1995
Page 2
1;:;;::;~~l;::;:;~~:;::~;:;§~;:~.:::~~;:;::~~:~~M~;:~r.A;~ª~;:~;'~;~~~:ç:Q~~:~Aº§§::.
......... ...
.........
):mmm:m,Açro.PtÆiA§~~$giºM'"*t§P!4~§~)·
TOTAL
o
.1:z;-:'~;;:w;~¡~=ng1~{~~Q:M=;~~;~=~~9f INCIDENT & CAUSE
,
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
o
T9T"L
Unplanned Events < 1 Hour 13,966
Unplanned Events> 1 Hour 2,368
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 20 045
TOTAL FLARED VOLUME 36,379
r-...
f"ll..LIII(
e
e
REPORT NO:
95-2990
mi
~ c/ ¿ jlj 5
BPX FLARE REPORT
PRUDHOE BAY
AI<:;3Ka Vii Ót Gas COliS. t;ommìssion
Anchorage
FACILITY: GC-3 DATE: 03 Aug 95 TOTAL VOLUME: 350 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 10:38 TO: 12:11 1 Hrs. 33 Mins. 00 D D D 350 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
LPS compressors went on speed control due to transit line pressure increasing and wells unloading.
Action Taken to Stop Flaring:
Arco shut in 50 mmscfd and BPX shut-in 30mmscfd. Actual flaring time was 42 minutes.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
/Date:
I
~, ~LI y' C_ e
..
REPORT NO: 95-2993
~)c/ 2 ì 1995
mi 1-\1~;)I\a Uil & Gas Cons. Commission BPX FLARE REPORT
Anchorage PRUDHOE BA V
FACILITY: GC-3 DATE: 04 Aug 95 TOTAL VOLUME: 17 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 19:00 TO: 21 :10 2 Hrs. 10 Mins. 00 0 0 0 17 MSCF
2. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. Gas Transit line high pressure due to wells unloading. This was two flare occurances that totalled 3minutes.
Action Taken to Stop Flaring:
1. Shut in gas from marginal sort with ARCO.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-2999
R t. "'-' ~ < J
.Lt If t \
~c.r' 2 ì i995 BPX FLARE REPORT
PRUDHOE BAY
laska \.,HI & Gas Cons. Commission
FACILITY: GC_3AnCh°f:i\-E: 09 Aug 95 TOTAL VOLUME: 233 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 16:33 TO: 17:15 o Hrs. 42 Mins. 00 0 0 0 139 MSCF
2. FROM: 19:52 TO: 22:33 2 Hrs. 41 Mins. 00 0 0 0 94 MSCF
3. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
4. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
5. FROM: TO: Hrs. Mins. 0 0 0 0 MSCF
CHECK ONE: FLARE/RELIEF VALVE: RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1 . High gas transit line pressure which was caused by rapidly increasing ambient temperatures.
2. High gas transit line pressure while bringing up rate from Annex reboiler sId .
Action Taken to Stop Flaring:
1. Reduced LPS gas to GC-3 C-Bank using wells on WOA.
2. Reduced LPS gas to GC-3 C-Bank using wells on WOA.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
e e
R ~~ _ L ; \1 t D REPORT NO: 95-3002
~[¡J 2 ì 1995 BPX FLARE REPORT
Alaska LHi & Gas Cons. Commission PRUDHOE BAY
Anchorage
FACILITY: GC-3 DATE: 10 Aug 95 TOTAL VOLUME: 236 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 10:34 TO: 14:20 3 Hrs. 46 Mins. 00 D D D 104 MSCF
2. FROM: 15:10 TO: 16:10 1 Hrs. o Mins. 00 D D D 132 MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
1. High gas transit line pressure which caused LP flaring for a total of 15min. intermittently through this
incident.
2. LP flared for 19mins. during ambient spikes causing LPS compressors to go to Temp. control.
Action Taken to Stop Flaring:
1. ARGO and BPX reduced gas rates to the gas transit line.
2. BP trimmed LP rates.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
e
~"'."' ,'~ ".'. .
.,: . r- U
. t.. L I v L
;) ':J' ¿ ì 1995
SPX FLARE REPORT
PRUDHOE SA V
dKä lJiI &. Gas Cons. Commission
Anchorage
FACILITY: GC-3 DATE: 11 Aug 95
Intermittent
TIME OF FLARING: DURATION: Yes No
1. FROM: 11 :40 TO: 11 :55 o Hrs. 15 Mins. 0 00
2. FROM: TO: Hrs. Mins. 0 0
3. FROM: TO: Hrs. Mins. 0 0
4. FROM: TO: Hrs. Mins. 0 0
5. FROM: TO: Hrs. Mins. 0 0
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK:
e
REPORT NO: 95-3004
TOTAL VOLUME:
Black
Smoke? Planned?
o
o
o
o
o
o
o
o
o
o
CONTROLLED BLOWDOWN:
104 MSCF
VOLUME
104 MSCF
MSCF
MSCF
MSCF
MSCF
OTHER:
First Determination of Cause:
High Slugcatcher pressure due to switching LDF incoming flows from A and B pads for repairs on B bank oil
dehydrator.
Action Taken to Stop Flaring:
BPX trimmed back high GOR wells at GC3
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
KL e e
",'''' ~' , REPORT NO: 95-3005
- L , "tV
1... _ J '
~ 0.:_f ¿ ì )995 BPX FLARE REPORT
AJé:Ska u¡1 Õt G"s G PRUDHOE BAY
d OIìS G '
Anch . ommlssion
orage
FACILITY: GC-3 DATE: 12 Aug 95 TOTAL VOLUME: 3,399 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 00:33 TO: 01:08 o Hrs. 35 Mins. D 00 D D 3,281 MSCF
2. FROM: 03:21 TO: 04:39 1 Hrs. 18 Mins. 00 D D D 118 MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED SLOWDOWN: OTHER:
First Determination of Cause:
1. Odd reboiler SID GC-3 flared per Transit gas dew pt. guide-line.
2. LPS compressors driven to temp control by ambient swing. Total 17 min.
Action Taken to Stop Flaring:
1. Odd reboiler back on and up to temp. GC-3 backed out of flare.
2. Trimmed LP wells at GC-3
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: /Date: I BPX Representative:
Yes: No:
IDate:
e e
REPORT NO: 95-3012
R. ~ ~ ; ': [: D
I' .
mi 2ì 1995 BPX FLARE REPORT
;) ., -'
t..! PRUDHOE BAY
J.\lc.5Kd VII & Gas Gons. Commission
GC-3 Anchor~ 17 Aug 95
FACILITY: DA : TOTAL VOLUME: 1,336 MSCF
Intermittent Black
TIME OF FLARING: DURATION: Yes No Smoke? Planned? VOLUME
1. FROM: 21:32 TO: 24:00 2 Hrs. 28 Mins. D 00 D D 1,336 MSCF
2. FROM: TO: Hrs. Mins. D D D D MSCF
3. FROM: TO: Hrs. Mins. D D D D MSCF
4. FROM: TO: Hrs. Mins. D D D D MSCF
5. FROM: TO: Hrs. Mins. D D D D MSCF
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK: CONTROLLED BLOWDOWN: OTHER:
First Determination of Cause:
Surging of low pressure compressor K-305 due to cutting oil into GC which reduced gas rates thru the plant.
Assist gas was added to low pressure flare to keep from black smoking. Oil rates where cut due to shutting down
Wier water injection pump P-7504 for seal repair.
Action Taken to Stop Flaring:
Added H.P. gas to help increase total L.P. gas rate thru GC, this helped reduce the amount of assist gas need for
L.P. flare. Repaired seal on water injection pump P-7504 and increased oil rates into GC.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: IDate: I BPX Representative:
Yes: No:
IDate:
R 1"/ to
i. L ~ L
'" ,J ') '\ '\995
-..)L! L
&i
c.SKa UII &. Gas Cons. Commission
Anchorage
FACILITY: GC-3
e
BPX FLARE REPORT
PRUDHOE BAY
DATE: 18 Aug 95
TIME OF FLARING:
1. FROM: 00:00 TO: 04:03
2. FROM: 11 :38 TO: 12:27
3. FROM: 13:32 TO: 13:45
4. FROM: 16:54 TO: 17:25
5. FROM: 19:15 TO: 19:25
DURATION:
4 Hrs. 3 Mins.
o Hrs. 49 Mins.
o Hrs. 13 Mins.
o Hrs. 31 Mins.
o Hrs. 10 Mins.
Intermittent
Yes No
000
000
000
000
000
CHECK ONE: FLARE/RELIEF VALVE: X RUPTURE DISK:
e
REPORT NO: 95-3014
TOTAL VOLUME:
Black
Smoke? Planned?
o 0
o 0
o 0
o 0
o 0
8,031 MSCF
VOLUME
217 MSCF
5,750 MSCF
225 MSCF
520 MSCF
1,319 MSCF
CONTROLLED BLOWDOWN:
OTHER:
First Determination of Cause:
1. This item continues from report 95-3013, Surging of low pressure compressor K-305 due to cutting oil
into GC which reduced gas rates thru the plant. Assist gas was added to low pressure flare to keep from black
smoking. Oil rates where cut due to shutting down Wier water injection pump P-7504 for seal repair.
2. LPS compressor shutdown due to high temperature shutdown.
3. LPS compressor failed to load on restart.
4. Wells unloaded during ramp-up, and ambient temperature came back up 5 degrees while compressor was
shutdown.
5.LPS compressor shutdown due to high temperature shutdown.
Action Taken to Stop Flaring:
1. Added H.P. gas to help increase total L.P. gas rate thru GC, this helped reduce the amount of assist gas need for
L.P. flare. Repaired seal on water injection pump P-7504 and increased oil rates into GC.
2. Cut approximately 250 MMSCFD gas rate. Controls techs found loose connections in panel.
3. Techs repaired PLC and loaded compressor.
4. Cut approximately 75 MMSCFD to stop flare and reduce transit line pressure.
5. Cut approximately 220 MMSCFD gas rate. Controls techs found more loose connections in panel.
If >11 HRS., the PCC will notify AOGCC (907) 279-1433. STATE TELEPHONE REPORT?
AOGCC Representative: Date: BPX Representative:
Yes: No:
Date:
~
ÀLÀSKA,(HL ^.l~D pAS CÔNS~RVÅTIO~ COMMISsiöN
FACILITY REPORT OF PRODUCED GAS DISPOSITION
..~;" t,J
AUG 1 8 1995
Facility
GATHERING CENTER 3
Operator
ARCO ALASKA, INC.
Field(s)
WESTERN OPERATING AREA-PH
as Cons. CommiSSion
chorage .
e
Disposition
1. Sold 0
2. Reinjected 0
3. Flared or vented less than 1 hour 1.339
4. Flared or vented greater than 1 hour 4,250
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge 25.278
6. Used for lease operations 507,085
7. Other 0
TOTAL items 1 - 7 537,952
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: 0
11. Transferred to: CCP 24,639,539
Remarks:
I """'bv ce:ø the fore...... is true and correct 10 the best of mv knowled...
Signature: . ~ Title: SUPERVISOR
rorm lU-4:lZ (RevIs '/
e
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 100
Official Use Only--Flarin AUlhorization > 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
ote: vo urnes must correc to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
¡
BP EXPLORATION (ALASKA) INC.
PRUQHOE BAY UNIT -.GC-3
GAS FLARINq INCIDENT REPORT
JULY, 1995
Page 1
e
L!J.&J..'1~111II:.I' Events less than or equal to 1 hour
:m@tttö.ÄtSf:m:m:m:m:m:miHrrmM¡Wt:r~:r~r:~rrr:r:ttvø.WMê.:mf]rrrÞE$.Øf.jRtlø.fd).f.tl1k3j)êH.ltitºJ.ij$.ttt::::m:t::::t:::::::f~rr:f:r:if:ttrtt\..ø.tlö.HttAkt8ttft.WNi.::ç*ij$.ljjj:¡rrrr::rrm:::m:r~
··········7iiJ95..···..·······1Ó26~·1Ö32·················.......... ··············1·25r\joÚ~ëëtu¡red·fo¡;·unpianneëi·èVenÙ¡whiCtl··....... ....... ·············Not·¡;ë·qu¡¡;ëd·for unplanned events which
7/6/95 0236-0258 275 are less than or equal to 1 hour are less than or equal to 1 hour
7/8/95 1141-1230 142
718195 1939-2019 222
7/10/95 1525-1529 14
7/17/95 0635-0702 113
7/19/95 0417-0429 125
7/19/95 0504-0516 125
7/20/95 0150-0206 198
"
TOTAL 1,339
IUnplanned Events greél,ter thanJ h~ur.._ ... ._.__._
::~m:::~m:r::PAt§tI:~::I:~::::::::~:::::::::m::::tnMft:::::::::::::::::m::~::::::r:::::::::m:m¥Þ,º.r::::::::r::::::::~:P¡;$.ØRij!D.ø.ffØFl"¢.IQ.~N1rf(ÞAP'$.ijjjj~r::::r:::~:::~::f::::t:::::~::::t::::::::::::r:f*-¢nø.ft::;r~::t(:tJ;QM'ØAj¡:~ÞAø.Hf::fff:~:r::):f:::::j~::::~:::
7/5195 1307-1533 "f25"H¡ghgaš"transit)¡;ës~duetolnëreašë"ämb¡ëiitiëmp"Arooand..BPxëutgasratë·s............. ........................ ..
7/14/95 0337-0900 4,125 Depres. D,P, Y Pad LDF's for IM-3/ine conversion. Finished depressuring D.P, & Y Pad LDF's.
TOTAL
4.250
e
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT -..GC-3
GAS FLARING INCIDENT REPORT
JULy, 1995
Page 2
IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
TOTAL
ACTION TAKEN TO ELIMINATE CAUSE
o
I
e
IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
f .~,
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events > 1 hour and
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED VOLUME
o
TOTAL
1,339
4,250
°
- ,. ~ ED
f:..
. ¡... I
AUG ì 8 \995
I$M ~I~ ~ bas Cons. CommissiQn
~~----- \ AnGbø.rag&.
o
25 278
30,867
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
I Facility
GATHERING CENTER 3
Disposition
1. Sold
2. Reinjected
e
3. Flared or vented less than 1 hour
I Operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report rcquired--Sec 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL items 1 - 7
8. NGL gas equivalent produced
e
9. Purchased gas
10. Transferred from:
11. Transferred to: CCP
Remarks:
:;r)
rT'ì
n
,rT1
~'·'....,.i
""..-.
~........
rn
r"")
'-
2,556
22,965
524,527
550,724
25,382,017
I hereby certify that the forel!oinl! is true and correct to the best of my knowledl!e.
Signature: tJ.~" ~ Title: SUPERVISOR
t'orm lO-4~R~ViSed 4/95)
I Field(s) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PH Jun-95
*Indicate contribution of each pool to total.
°
Code
Pool Name
Percent
°
PRUDHOE
100
640150
676
°
Official ÜSeOnly--FlaringAllthorization > 1 hr.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psi a and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
JUNE,1995
Page 1
e
IUnplanned Events less than or equal to 1 hour
:::::r:ºÂJ~::~::::::::~:11.M§~\::~::J~~:Yº!;'ºM§::::;:{::Þ§$ÇRIR;m~ijQf!~¢Iº~ff:t~ÇAº$~:::::.:AQ:l1ºtÜrAK!;N;n:)~:;J"'!M!NAT!;ÞAI..J.§f#
6/2/95 0138-0154 167 Not required for unplanned events which Not required for unplanned events which
6/2/95 0418-0425 73 are less than or equal to 1 hour are less than or equal to 1 hour
6/16/95 1033-1116 56
6/18/95 1618-1656 185
6/19/95 1518-1534 69
6/19/95 1832-1856 125
6/21/95 0211-0214 1
TOTAL 676
I.".:.U,:.:,...~:...:._~,:.:,~.,:,..p'::"'.""..D.'.'...a..,'A....,..,n..'.T.,....n,,~......~:.:::..:.,.d::..~:..::..:::.:::.:.E:...::.:.:::.v,:.,:.:.::.:.e...:...:.:...:.:.<,n.::..........,t.::,:.5,..!:n".....,..g......M.......r..E..e......:,.:.a,...::..:,t.,..:...e...:.........r.:.:.:.:.:..:.t..:....h.:....':.:::.a::.:::.::.:.n:...::.:..:.:.,:....:...:1,....,....:..:,..,h0..'.........0...,.,..,.:..'..uu......,'.Mr.........E.........'.'
nv "":.QF$ÇR'gT!þNþfINÞmBNr~çAº§!;}
6/6/95 1200-1325 542 High gas transit line pressure.
6/7/95 1148-1438 317 High gas transit line pressure.
6/7/95 1624-2115 375 High gas transit line pressure.
6/15/95 1845-2015 972 High gas transit line pressure.
6/17/95 1003-1115 350 High gas transit line pressure.
............................................ ... ·T· ,. ...... .....". . .... ··:·c···'·' ......................
iAPT!ºNAJS;~·Œ.º~PM'~A[êA\..I§§<
Arco & BPX cut gas rates.
Arco & BPX cut gas rates.
Arco & BPX cut gas rates.
Arco & BPX cut gas rates.
Arco & BPX cut gas rates.
e
TOTAL
2.556
s;r
¡r'e,
("')
í4l
.,
¿ ~1
t".,
è":' C?
~
~
,,!,~"'"
.,."
~~
r;--:.
(""':"
-,......
·. ,
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
JUNE, 1995
Page 2
I~~:~:~;~~::;:~:~~.:~:~:;:~:~~~..~~~..~~~:~~~o~~..~;~~~;:e~;;;~~~q:q~::~Å4$§~:~~~~..'..:~..:::~.'
TOTAL
." 'd, .... ......
..................
..................
.................
..................
..................
..................
. . . . . . . . . . . . . . . . .
.... .............
~))(ACTl()N:iÂKEN'I'().ï;UMINA.TêcÂI.JSE);
.............................-....................... ............... .... ........................
....... .......................................................................................
..... .... .
o
IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events > 1 hour and
exceeding 5,000 MCF
e Pilot Purge
TOTAL FLARED VOLUME
t~,·
~"...
!! i r:
{
r....
'. }
PI!"1
~~
..
rf1
r-~"
"".:--.--'
o
TOTAL
676
2,556
o
o
22 965
26,197
OPERATIONS
ID:907-659-4531 JUN 26'95
· BP EXPLORATION (ALAS.
PRUDHOE BAV, ALASKA
FAX # (907) 659-4531
".j' l~ lL'~ c. .... Ir,\WJ C" ;,¡C" \\1) 1'-: rj;;)
~.~I,C.(Q)Ir"~\,I ......L [))..~ l,t;:H,.iJ
Cr:> II !11~I....r-¡:>
,~ ¡ry.1â.Ù
TO: Mr, Blair Wondzell
COMPANY: AOGCC
LOCA TION : Anchorage
9:16 No.003 P.Ol
6
FAX #: 276-7842
FROM: Bill Broman
~
OPERATIONS PHONE #: 659·4472
LOCATION: PRUDHOE BAY, ALASKA
PAGES TO FOLLOW: 1
DATE:
6-26..95
COMMENTS:
REßE\VED
JUN 2.6 }99S
~ss\O\·
AlasJœ. Oil.& Gas Cons. Camm
.. ~cborag9
IF YOU DO NOT RECEIVE ALL PAGES, OR HAVE ANY PROBLEMS,
PLEASE CALL THE FOLLOWING NUMBER:
(907) 659·4528
OPERRTIONS
ID:907-659-4531
e
JUN 26'95
9:17 No.003 P.02
(ß
e
..
BP EXPLORATION (ALASKA) INC.
P.O, Box 196612, Anchorage AK 99519-6612
REPORT OF ACCIDENTAL NATURAL GAS RELEASE
DATE: June 26, 1995
TO: Mr. Blair Wondzell
Alaska Oil and Gas Conservation Commission
3001 Porcupine Drive
Anchorage, AK 99501
FAX: 276-7542
DESCRIPTION OF INCIDENT
.....
1, Date and Time:
.....
Wednesday, 06/21/95, 2:11 AM
2. Location:
Detailed L.oç~:
L Prudhoe Bay Unit
_ Endicott
_ Milne Point
_ Nlakuk
_ Other
_3. Voiume of natural g..I~~ .
4. Cause of loss:._. Thro!J9h..~all penetration of Well C-17 choke tail piece
5. Actions taken and planned Choke was repaired. Investigation team looking into further
.. ... to prevent furthElr loss:_ opportuníti~s for prevention:.. .....
6. Equipment or procedural Investigation team will review operating procedures.
changes to prevent loss
from recurring:
7. Contact (name and
telepho'1~ ... numbe r):
GC·3 Module 4A Well C·17 choke
... .
William H. Broman 907-859-4472
Signature:
o/d(.9ðq _
co: BPX Environmental Compllanoe Supervisor MB 11-6 (FAX 564-5020)
BPX VDlume Accounting MB 5-4
Production CoordInator
Facility Superintendent
REQEIVED
lJUN 26 }995
NasEa DU& Gas Cons. Comm\Ss\on
AnchoraglJ
FORM REV 6/96
\...
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
REVISED
I Facility
GATHERING CENTER 3
Disposition
1. Sold
2. Re~njected
e
3. Flared or vented less than 1 hour
I Operator
ARCO ALASKA, INC.
4. Flared or vented greater than 1 hour
(Supplemental report required--See 20 AAC 25.235)
5. Pilot and Purge
6. Used for lease operations
7. Other
TOTAL item!! 1 - 7
8. NGL gas equivalent produced
e
9. Purchased gas
10. Transferred from:
11. Transferred to: CCP
Remarks:
*"'.
t,r
2,840
20,063
27,440
588,682
639,025
(
( .
F-""''''
,
J-¡-¡
(")
f''1ï
"",,-,;
J--!'fII.
.<t,......
.-~.
, t:. ~
r=O)
>-.~....--í
27,257,444
I hereþy certify that the forel!:oinl!: is true and correct to the best of my knowledl!:e.
Signature: (/ ~ _
rOOD lO-4tZRe~ised 4195;'" .
Title:
SUPERVISOR
I Field(s ) J MonthlY ear of Disposition
WESTERN OPERATING AREA-PB May-95
*Indicate contribution of each pool to total.
o
Pool Name
Code
Percent
o
PRUDHOE
100
640150
o
OrricialUsc Only--Flaring AUlhorization > 1 hr.
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235.
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
MAY, 1995
Page 1
~.~Ia_~.r.:aed Eve,l!!s, 1~s.!;Jhan orequ,~_IJo 1",~.~..ur ",_ ___,__.___.__u_",_,_.__ ..._ ",___ ,,,_
¡::If:¡:::¡j:fÞ.ité¡'::t:'II:¡III¡¡¡:¡:¡:::¡:¡jjMi:::¡:¡¡¡¡¡¡It:"IŒIImIŒIMø.tÞ.Mi¡::¡¡:I:::It¡:::Þi$.¢ø.i.!tr~gN::Þf{:jNÞ.tQt¡¡Nr:ltgÂP$.g,I¡¡¡tm¡:¡II:::I¡:'I'ŒI¡¡:I¡¡:¡:I¡¡I¡::I,¡:II:APÍlgN::1ÎKgN.?tø.:¡t.1.MlijA1t;ijt.iøøtm:m¡::¡¡:¡¡¡:¡t::,itII¡:¡I:'
5/2/95 0128-0226 1047 Not required for unplanned events which Not required for unplanned events which
5/3/95 0434-0531 554 are less than or equal to 1 hour are less than or equal to 1 hour
5/3/95 1847-1924 257
5/4/95 0732-0757 217
5/4/95 1553-1624 172
5/30/95 0803-0824 160
e
e
TOTAL 2,407
~Unplanned Events areater than 1 hour
5/3/95 2121-2323 1,017 High transit pressure due to L TS SID Arco cut gas
5/4/95 0127-0304 876 High transit pressure Arco cut gas
5/4/95 0447-0638 590 Wells unloading in LP after corrosion inhib. trmt. Switched LP gas to HP
5/9/95 1519-2203 122 Ambient air temperature increased PCC trimmed LPS gas rates.
5/15/95 1637-1744 225 Increased LP gass when switching D-LDF to GC3 BP cut gas
5/23/95 0138-0416 63 D Pad LDF was routed from GC1 to GC3 . Switched LP wells to HP to reduce gas rates
5/23/95 1721-2010 384 D Pad LDF was routed from GC1 to GC3 . Switched LP wells to HP to reduce gas rates
5/24/95 0819-1616 931 High transit pres. due to increasing ambient temp. ARCO and BPX reduced gas rates.
5/24/95 1822-1929 13,500 K7001 LP camp sId due to faulty signals from PCM. Compressor was restarted
5/25/95 0251-0510 90 High LPS gas rates Trimmed LP gas rates.
5/27/95 1101-1211 90 High transit pressure Arco cut gas
5/31/95 1724-1829 900 High transit pressure ARCO and BPX reduced gas rates.
TOTAL 20,063
.4 .\\~ t \)
\)\rCt.
\' ,..,.
(\ '\
ç'c\ ( -
\"~ "'~
5/'ZA - tJo...l'M IN ;'
5J'Z,3 - \N~j f:£/?c.JïlJ\::.~
Ð PAù ~
"''''V'~
""'~J"''''
Ct;\\'\'·'·
. ,.:., \lj~s. .
., \;i';""
t"t ."?r
f';\,.\,;'r.o, '
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
MAY, 1995
Page 2
l~a.~.I)~ "E_vents less Than, or Equal 1 Hour AND, Not.,Ex~~di..ng ,~.oOO..Mc.f.._ ,
TOTAL
..................
...................
433
~
~Planned Events Exceeding 1 Hour OR Exceeding 5.0.0.0 Mct
TOTAL
e
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOlUME
" .' \)
D ,~(t\ \j t. ~
~.... ~.....
, t:,
f" t\
¿ \
. ."è~O~\
'~I"<.¥' ",< r'\r.)\\\~:\\\iJv\
r~r \)U,\'j, .-
t~ ..:,ù:.·..~J
Þl.nC\1Ûr:
. .....
.0
TOTAL
2,407
20,063
433
o
27.440
50,343
.". "Of
...-------
MEMORANDUM
TO:
David JohnstøfÍ.
Chairma~
THRU:
Blair Wondzell, Æ~
P. I. Supervisor 57r1
Doug Amos~
Petroleum Inspèttor
FROM:
State of Alaska
Alaska Oil and Gas Conservation Commission
DATE: May 14.1995
FILE NO: gj9hencd.doc
SUBJECT: Gas Release
BPX PBU A-Pad
Prudhoe Oil Pool
Sunday. May 14. 1995: I received a call from Bobby Foster and was informed
that there had been a gas release at BPX PBU A-Pad early this morning.
I traveled to A-Pad but was denied access due to the evacuation of gas from the
module to the atmosphere. I contacted BPX Environmental Specialist Wade
Schrok to get the details on what took place. Wade told me that there was a
flange gasket failure in the gas lift module which filled the module with gas.
There were no injures, no release of oil and no damage to the module.
î
Wade had no figures on the volume of gas released or the reason for the gasket
failure. Wade will be filling an incident report as soon as the area is cleaned up
and the assessments are made.'
SUMMARY: I conducted a fact finding investigation on the release of gas in the
gas lift module at BPX PBU A-Pad. !
J ) t'" (...
.7() ;..-- {t!.t:..J . ;~/7..r.J.~
UX'''· I·qv- !L,J.
(0'* ~
,e
e
6
"r .,L
/
Mr. Blair Wondzel
M;::ay 17,1995
Page 2
27a~ 7542
1995
17,
FAX #
May
Mr. Blair Wondz(;!1I
Alaska Oil and Gas Conservation Commission
3001 PorcLJpi ne Drive
Anchorage, AK 99501
Notification of Accidental Loss of Oil or Gas
Prudhoe Bay Western Operating Area, A Pad, Skid 56
I
The following information is submitted as required by 20 AAC 25.305(b). On
May 14,1995, a lifting gas release occurred at Skid 56, A-Pad. in the Prudhoe
Bay Western Operating Area. Wade Srock reported the incident verbally to you
at approxi mately 0950 hours on May 14, 1995.
1
14th
Wondze
Time of Incident. A low gas alarm sounded at 0530 hours on May
1995. The release continued for approximately 12 minutes.
Mr.
Dear
n the Prudhoe Bay
location. The release occurred at Skid 56 on A Pad,
Western Operating Area.
2
that approximately 0.5 million
Volume of natural gas lost. BPX estimates
cubic feet of gas were released.
3.
CaU9é of loss. Failure of a flange gasket on a gas metering device caused
depressurization of the gas lift system. The failed gasket was found to have
been incorrectly fitted.
4.
Actions taken and planned to prevent further loss. All other similar
gasket installations within the module were ctlecked. No othar incorrectly
fitted gaskets were found.
5.
Equipment or procedural changes to prevent loss from rocurring.
Proper installation of gaskets should ensure that failures of this type do not
occur. An in-depth incident review is focusing on installation procedures for
the gaskets, R E C E , V E D
6.
CommiS~ji9J!
M,4 Y 1 7 199:>
dlas~ét.oil &. Gas Cons.
~'chorag,
AH 1N3S
e
SG-l.1-S
Ndgt:~1
J1J1II1IIOJ XdH
e
ðOqpn1d
!-
1
#: ~tSL 9L& LOG
1
ñ-f ~
d-
Mr. Blair Wondzel
May 17,1995
Page 2
rnf:! al 659-4472.
you have any questions, please contact
If
PBU-WOA
Sincerely,
J:7- rJJ~
~¿. Garry Meek
f - Production Coordinator.
Ijm
cc: Jack Maddux/Dan Blanchard, Operations Superintendent
Janet Platt, BPX ERAD, Anchorage
Mary Cocklan-Vendl. BPX ERAD Anchorage
Carol KleinJWade Srock, PBU-Envlro Compliance
REef
VEO
,
1 7
& Gas Cons. CommisslQI
Anchoraga
1995
MAY
Alaska .Oil
Á\] .LN3S
e
£S-L1-9
Nd9t:61
J1JUlUlOJ XdQ
e
aot{pnJd
....
1
G #:6v£L 9LG LOS
....,*"~ ~. ilL-J.'.>:'
._I.'",,;!I:i::.-:,,1
, .
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
BPX
Field(s}
WESTERN OPERATING AREA - PBU
Disposition
Volume MCF'"
1. Sold 0
.einjected 0
3. Rared or vented less than 1 hour 2,969
4. Flared or vented greater than 1 hour 65,183
(Supple""DIaI ~pon requi...4-·S.. 20 AAC 25.235)
5. Pilot and Purge 22,547
6. Us~d for lease operations 537,419
7. Other (Production sent to CCP) 21,227,513
TOTAL 21,855,631
of Disposition
"'If production comes from multiple pools,
indicate contribution of each pool to total.
Pool Percent
{(:L/C"" /S 7S~ / C':'. c-
Offici'll \J~e OIlI)i,lõlallll; Alllhori:r.alion> 1 hr,
1. Safety MCF
2. Lease MCF
3. Conserv. Purposes MCF
.: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F.
win the month of dis osition. Authorit 20 AAC 25.253
Remarks:
I hereby certify that the foregoing is true and correct to the best
Report due by the 20th of the month
Signature
Title
of my knowledge.
c:. ,-..d c~ - ., '&0
J,....: 7
Date:
--~L
'l ~ /7.5--:-
.~
Form 1 ()"4 22
Rev. 11194
. '.
. .,
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
APRIL, 1995
Page 1
lunplanned Events less than or equal to 1 hour I
tttt:tÞ.ÄÎitt::t:ttmt::tt:IJjMJ¥tttItttttttt:]~º'ºMi.\t:tt~tm:Pj$.ÇfjRD9tH~FJt~¢Ip.iwt:.::çjQ$.Îttt:ttm::::::::ttttmt:::¡~tti::::::Im¡tA¢Tl9t!ttÜgÜttttIt1Mt.NÄTi~:Mº$.§:::::::~:::t::::~t:t:::::rItr:¡:~~
4/1/95 0326-0341 833 Not required for unplanned events which Not required for unplanned events which
4/10/95 1508-1524 1,000 are less than or equal to 1 hour are less than or equal to 1 hour
4/17/95 1040-1045 35
4/17/95 1252-1254 14
4/19/95 1707-1718 76
4/24/95 0348-0421 779
e 4/28/95 1149-1210 232
TOTAL
2,969
e
~~_.mø1E®'·J~~!!!I!!~~~m.J
4/11/95 1756-1908 133 Depres. header from A pad to gathering center. Gas rates were cut to stop flaring.
4/14/95 1045-1625 563 LP gas was so low that LP compr. surged. Flare pad back in service.
4/15/95 12Q6-2400 593 LP Compr sd due to lack of gas Bring up plant to prod. more gas.
4/16/95 000Q-240Q 2000 LP Compr sd due to lack of gas Bring up plant to prod. more gas.
4/17/95 0º00-05~ 696 LP compressors shutdown due to lack of gas Increased gas rate and started LP compr.
( 4/20/95 0856-1445 10664 K305, K308 SID during bridle work on V336 Started compressors following repairs.
.~ 4/20/95 1518-2158 3611 K305,K308 SID during bridle work on V336 Started compressors following repairs.
L 4/20/95 2248-2400 650 K305,K308 SID during bridle work on V336 Started compressors following repairs.
4/21/95 ºº01-21 05 40378 IP Compressors and LP Compressors shutdown. Started compressors following repairs.
4/22/95 1130-1329 92 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
4/24/95 0625-0801 1079 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
4/25/95 1749-1859 904 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
4/26/95 0506-0955 1158 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
4/28/95 0006-0106 340 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
4/29/95 1750-2134 2169 High gas transit presr. due to ambient temp. ARCO and BPX reduced gas rates.
TOTAL 65,183
11';:¡~'!'ITrTlo;'~'lo I f~~'( .¡o;q')'11 I! .I-:tim ill]:1 ~ t1ir.J.i'!'IIII'j r:;
¡tttttgm¡tt¡t¡¡¡¡¡¡¡t¡¡H¡l¡ttnMjf:~tftMtt¡t¡¡¡¡!¡¡¡¡¡:¥§i.YMj¡ttf¡t¡t¡pg§ÇØä1a~¡gj¡¡W§Im¡,¡¡g4.g§§:!tM¡t~¡t¡tt¡:M¡m::!:!~:¡¡:¡!!:j!!¡j:¡!¡¡¡¡¡¡!!¡"§11.§H¡¡t.~trg¡:gÜMMÎi.¡:þjP.~t¡¡¡:~¡::~¡¡¡¡¡:¡tt¡!¡t¡j:::::¡¡¡:!¡t:¡j:
TOTAL
o
"
. .~
. ".
e
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOLUME
e
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
APRIL,1995
Page 2
..:.. :.TQI~~·/ \:
2,969
65,183
o
o
22.547
90,699
e
e
I spoke to Gary Meek at BP on August 10, 1995 about the following events that were
reported for April:
The most cornmon types of flaring are Ambient temp. (CCP), Reboiler shutdown (skid
18). Transit pressure and ambient temp are almost always intermittent.
Gathering Center 1
04/01/95 Skid 18 compressors not loading
The compressor at the electric driver is very sensitive when started up and they end up
bumping the flare. If this equipment shuts down the whole Gathering Center will shut
down. They play with the compressor controls and the recycle valve. They recycle the gas
from the outlet to the inlet. If the compressor surges, then the 2nd and 3rd stage will trip
out and flare. Skid 18 contains the 2nd stage to IP compressor and the 3rd stage LP
compressor. They replaced the computer control systems. A small compressor controls
the flow. If they lose the load, then they start to bog down. - Not loading. They suspect
the LP were having problems. Sometimes they have to bring on more wells in these
situations.
04/01/95 Odd reboiler SID
04/03/95 Even reboiler SID
He couldn't tell me exactly what the problem was with the reboiler SID.
When events last over 1 hour then they usually have problems with restart attempts.
These were continuous flaring events. On the 1 st, they flared a high rate for 15 minutes,
they started shutting in wells and flared at a low rate for the next 2 hours. On April 3rd,
they routed gas to the flare to avoid shipping wet gas to the transit line. They did reduce
rates, but he couldn't tell when. They should have started cutting rates 1/2 hr into the
event, at 2309, but they didn't start until 2318. Then they flared 40 more minutes.
04/1 0/95 Took their Odd train contactor offline to repair leak
There was a leak on the odd train discharge flow transmitter. They flared offthe
slugcatcher. This could have been a gasket leak. They took the TEG pump down, so the
gas was no longer dehydrating, so they had to flare. They cut back the slug catcher flare
valve to a minimum and cut the gas rates by shutting in several wells.
Gathering Center 2
04/02/95 LPS compressors on governor limited
04/16/95"" "
04/19/95"" "
This was intermittent flaring. He didn't know if theis was a temperature or speed
governor problem. The governor prevents the compressor from going over or under
e
e
range. They tried to speed up the gas rates but the compressor wouldn't take it. They
started tweaking backwells. The LPS compressors full safety systems weren't allowing
gas in. This is generally caused by having a packed separator upstream.
04/21/95 Excess gas due to cycling wet shutin wells
These were high water cut oilwells. The event gave rise to high LP gas rates. They cut
back the LP production. The event lasted 4 1/2 hours, but had a total flaring time of 63
minutes.
04/22/95
K205 SID when C bank slugcatcher sid.
04/23/95
LPS flaring bringing up well
04/24195 K7000 LPS compressor shutdown
15:05-24:00
They were having continuous control instrumentation problems. They tried to start
K7001 but had a failed attempt. They cut rates by 100 mmscfd by 15:30 so the copus or
starter turbine discharge pressure lowers enough to start the motor to start the compressor.
They ended up replacing the logic cards and the power supply. K7001 came on between
1500-2400 intermittently. At 23:00 Wand Z pads were shut in to cut the gas 100 mmscfd
more. Why weren't the gas rates cut earlier or enough? Ifnot enough gas in the system to
start the turbine, then it just won't start. It also can have an effect on other equipment. On
4/25, from 00:50-01:39 the K205 LPS compressor shutdown due to high vibrations. Not
enough gas was going through it as a consequence of the previous event.
Gathering Center 3
04/14/95 LP gas was so low that LP compressor surged
The flare system was diverted to the burn pit for a flare system inspection and repairs to
the flare system-tip replacement. They normally use the candles to minimize black smoke
events. This flaring causes black smoke because the gas is diverted to open-ended pipes
in the burn pit. This gave rise to too little gas in the LP compressor, causing it to surge.
Not enough flow causes loading or bogging down. It surges because it doesn't have
enough feed and the discharge starts flowing back in. This was an intermittent event from
10:45-16:25, but there was 81 minutes of total flaring. There was a TAPS event, too and
they cut to 95% nomination. The root cause was the inspection ofthe GC-3 flare pad,
which routed gas to the burn pit. They flared because the LP compressor wasn't loading
and had to put the LP gas to flare. If not, they would have had to shut down the entire
plant.
04/15-17/95 LP compressor sid due to lack of gas
This was a trickling flare over the course of 712 minutes. There was a planned SID of the
LPS system on the 16-18th. If the LPS system was shut down, then there isn't enough gas
for the LP system. with the TAPS slowdown each producer was cut proportionally. If
e
e
they're cut to 60%, then they will start with the higher gas and oil wells. They want to
maintain the most difficult production. Jfthey cut back GC-I and GC-2 more, then they
would have to freeze protect miles and miles of lines, since they have the higher water cut
wells, so GC-3 feels the brunt of TAPS slowdowns, especially in colder weather. This is
a safety and rupture preventative action. This event was either caused by the TAPS
slowdown, or by GC-3 maintenance work during the TAPS slowdown. He was unable to
tell me for sure.
04/20/95 K305, K308 SID during bridle work on V336
The bridle on V336 had dangerous corrosion. The V336 is a scrubber that comes off of
the JP, either the suction or the discharge. No gas rates were cut because they were trying
to avoid a total plant shutdown. The bridle is a looped piece of pipe which comes out of
the scrubber bottom and goes back in about halfway up. The bridle contains the liquid
level. The vast bulk of flaring was done on the 20th, from 9 a.m. to 3 p.m. and from 3
p.m. to 9 p.m. and on the 21 st, from 11 a.m. until midnight. During the event, they had to
get rid of the gas (depressure), purge with nitrogen, break the seals and replace the bridle.
Then they have to purge it with nitrogen again before they put it back together.
They loaded up the other train and they didn't cut rates because both the LP and JP
compressors were shutdown.
04/21/95 JP compressors and LP compressors SID
This is part of the event mentioned above.
. ~ .
.
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GA TIJERING CENTER 3
Field(s)
WESTERN OPERATING AREA - PBU
Disposition
Volume MCF'"
l. Sold 0
2. Reinjected 0
Aed or vented less than 1 hour 15,611
4. Flared or vented greater than 1 hour 5.362
(Supplomontol roporl øquiml--Soo 20 AAC 2S.23~)
5. Pilot and Purge 19,252
6. Used for lease operations 639,945
7. Other (Production sent to CCP) 26.569,861
TOTAL 27,250,031
MonthlYear of Disposition
Mar-95
..,
"'If production comes from multiple pools,
indicate contribution of each pool to total.
Pool Percent
.
O''icial Use Only-I:laring ^ uthC)rÌ7.at~an> ~ hr.
1. Safety MCF
2. Lease MCF
3. Conserv . Purposes MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
followin2 the month of disposition, Authority 20 AAC 25.253
e-rks:
-
I hereby certify that the foregoing is true and correct to the best of my knowledge.
.
Signature F~J3,... i't %~-J~~ 1\-1...>1 Title ...¡J fA-Þ,'sA; ~¿~''''- ... f?..u~ t(L-0~ Date: '111 Lis f-
Form 10-422
Rev. 11194
1'\
't~~!!p' ~','
-:'."
· ..
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
MARCH, 1995
Page 1
~~~=-_._-_.~"~.~~~)!!~~~~.~~~~:__,,I
30/95 1300-1308 111 Not required for unplanned events which Not required for unplanned events which
3/10/95 1216-1316 10,167 are less than or equal to 1 hour are less than or equal to 1 hour
3/17/95 2041-2057 167
3/24/95 2226-2246 1,444
3/25/95 1333-1426 336
3/27/95 1647-1700 1,237
3/28/95 1346-1412 2,149
TOTAL 15,611
e
¡unPlanned Events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
3/8/95 0646-0838 413 LPS turbines going into governor control.
3/25/95 0049-0350 1,938 Gas transit line pressure increased
3/25/95 0556-1119 1,682 Gas transit line pressure increased
3/26/95 0411-0805 1,329 High Transit Pressure
TOTAL 5,362
ACTION TAKEN TO ELIMINATE CAUSE
Sihfted gas rates to unload LPS gas system.
ARGO and BPX reduced gas rates.
ARGO and BPX reduced gas rates.
Trimmed up Gas rates
318 - UP l-A \ W
e
3)25' ~i , vVf\~ bvf:J0~
;; I ZG . " }.J\51f...C 60
\"..0(0 6 --::
-4 .¡. .
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
MARCH, 1995
Page 2
I:~:I:::;~~::;~:~:;::::~::;'§~~:·;:::;~:::::~~~~~M~~:~:~:::;:~~$;;:~~;;;~:~~ç::~~:~Iº§§ff:::::r':::f:rrrr::::::::::i:%f:::::êi~:j;!~H:Î9::~YM!t@I§::P.«I~O::oo
TOTAL
.................
o
~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct
e::::::::::::::::::qÎm:%:::::::::::::r:::%i:rln~::·::::::::::::::::::%::%%N19gqM~:::::::::::r::::::::g~§Çfl!B1J9fj9fnHÇJ.þ~fjI:I::Ç~Q$§::rrm/
TOTAL
e
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
TOTAL FLARED VOLUME
f
o
................................. ........ ........................ .............. ... - -..... .................................
..················'··A····....--··;rA· OK··· e··· N°··TO· o··E'···I·Mo.. ·1·..i...·T··· eO··""A··U···SE······ .......................................................
:::::::::::::::::::::: . :,,":I:I~n::::t:·.· .: :. :;::1; ';.:::L; ItM:;:; :;;\i.f;.:...... :;::::::::::;;;:::;:::;::::::::\::::;:;::::::-:::-;.;
......................................................,...............................................
. ..................................................................,...................................................
o
... .T9TA.L
15,611
5,362
o
o
19 252
40,225
e
e
,
I spoke to Gary Meek at BP on July 25, 1995 about the following events that were
reported for March:
Gathering Center 1
03/22/95 Even reboiler SID, lost TEG in contactors
The TEG flows from the top down in the contactor towers. They are operated near flood
conditions. A shutdown could be caused by 1) too much gas through contactors, or 2)
transit pressure line drops. This is more likely. If CCP lost a machine or if another plant
went down. They lost the TEG level. They don't have enough information on it. They
probably didn't cut gas rates, it's not documented.
03/25/95 LP compo could not remain online at present rates
GC 1, Annex, FS 1, and Ccp had water washes and drill site shutdowns. There was a big
plant SID with associated flaring t~ing to balance.
Gathering Center 2
03/01/95 SIC flare valve cycling off seat
The slugcatcher valve was "popping." The slugcatcher was packed so the valve was
lifting intermittently to keep the pressure up.
03/03/95 EWE compo shutdown due to flameout on turbine
This compressors supply comes from GC-2. The Eileen West End compressor
compresses and injects the gas. Flameout on turbine can be caused by 1) sensors (magic
eye) or 2) thermocouples. For the magic eyes the glass can get smokey, causing it to
rregister a false flameout. First, the operators try to restart the compressor and secondly,
PCC starts to shut in wells.
03/04/95 Increasing ambient temp. High transit line pressure.
Arco has higher GOR wells, so they should be shutting in first. This was an intermittent
event.
Gathering Center 3
03/08/95 LPS turbines going into governor control
LPS turbines went into governor control due to inlet heat from snow and ice blockage.
The turbine slowed down. They weren't getting enough gas through the separators, so the
valves were opening.
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GATHERING CENTER 3
Operator
BPX
Field(s)
WESTERN OPERATING AREA - PBU
MonthlYear of Disposition
Feb-95
Disposition
Volume MCF'"
1. Sold 0
Reinjected 0
':
3. Flared or vented less than 1 hour 0
4. Flared or vented greater than 1 hour 0
(Suppl....ulal report required--See W AAC 25,235)
5. Pilot and Purge 2 1.377
6. Used for lease operations 535.904
(includes øas; lift øas)
7. Other (Production sent to CCP) 23.687.836
TOTAL 24.245,117
"'If production comes from multiple pools.
indicate contribution of each pool to total.
Pool Percent
Official Use Onl y. Flaring 1\l1Ihorizlllion> 1 hr,
1. Safety MCF
2. Lease MCF
3. Conserv. ~urposes MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
lowin the month of dis osition. Authorit 20 AAC 25.253
emarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature
Title
S~
Date: 3.f, ö /~J-
. TL---
Form 10-422
Rev. 11194
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
FEBRUARY, 1995
Page 1
Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
I
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
o
e ~UnPlanned Events greater than 1 hour
DATE " TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
o
e
RECEIVED
MAR 1 4 1995
Alaska Oil & Gas Cons. Commission
Anchor~
,. .
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING INCIDENT REPORT
FEBRUARY, 1995
Page 2
Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
TOTAL
o
e
Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
TOTAL
o
;TRTA)"
Unplanned Events < 1 Hour 0
Unplanned Events> 1 Hour 0
Planned Events < 1 hour & not 0
exceeding 5,000 MCF
Planned Events> 1 hour and 0
exceeding 5,000 MCF
e Pilot Purge 21.377
TOTAL FLARED VOLUME 21,377
RECEIVED
ìv1AR 1 4 1995
Alaska Oil & Gas Cons. Commission
Anchorz
·
'"
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility
GA TIlERING CENTER 3
Operator
BPX
Field(s)
WESTERN OPERATING AREA - PBU
MonthlYear of Disposition
Jan-95
Disposition
Volume MCF'"
1. Sold 0
Reinjected 0
3. Flared or vented less than I hour 2,825
4. Flared or vented greater than 1 hour 2,277
(Supplemental reporl required..See 20 AAC 25,235)
5. Pilot and Purge 19,346
6. Used for lease operations 630,738
(includes gas lift gas)
7. Other (Production sent to CCP) 37,866,428
TOTAL 38,521,614
"'If production comes from multiple pools,
indicate cont!Í~!lti.Q.~ each pool to total.
./.~
Pool / - - .~ ~ Percent
I \ \
I
\
\ \ \
\ \
\
~ /'
Official· Use Only-Flaring Authorization> I hr.
1. Safety MCF
2. Lease MCF
3. Conserv. Purposes MCF
Note: All volumes must be corrècted to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month
llowin the month of dis osition. Authorit 20 AAC 25.253
Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
~
Signature
Title
J
Form 10-422
Rev. 11/94
RECEIVED
FEB 22 1995
Alaska Oil & Gas C
Anchor~n~,' Commission
Date:
~/?~
1
FEB 06 '95 10:50AM BP EXPLORATION TAX
.
DIdII
111ath
1/17186
11221D5
1~
11241II5
1/2eIDS
1131/95
To'"
leg. .. &rid. TII'II"
DulaUøn
2209-2220
1161-1227
1 518-1 $U
171.17!58
OD02-OOS1
*5-0718
097000918
$1:1I. ea (b1)
P.4/4
AOGCC Gas Flaring & Venting Incident Report Gt-3
o.te
111WitS
111'1tIS
1/17/96
Tall!
.-.n Z Unplanntd eventt !Jrater tilt" 1 !lOur
_ 6. End. TII1I.
DInIIøn
0030?072O
0S28-ð14S
¡gœ.2153
>1"r
Volum
Met
SIlO
CKI4
1,083
20m
OOR Rlpo~
'an t - Unplanned _ntI not exceeCIl"I 1 !lOur
cUll'
Vllfum.
Mal
153
2a6
.ce
550
760
542
535
I.N
$dI. 82 (lIS)
Pin 3 PIM::::::(I~ 1 h_:~~uwediIlllSODO Mat
DteI Dutlllon Mal
Total Sell. S2 (\14)
PI114 PIIftnICI ewnts UCMdlnsJ1 hour OR RCMdlng 5000 Mc:f
I
AOGÇC GIll fJUIn9 .. vonan,lncident At'*'
!eG. .. end. TImes c111r ,.111f
Da DurItIon Volumes Durltion Vol
.tho... lIat )0 t hour Mar
10'" Sch. Ða (be) 0 0
AOOCC Apt
LIn. S <lhr 2.825
u...b1hr 20m
AOGCC FIpt
Une 5 P." PUrge SCI'I. 82 (b2) 19.34$
u... , ContlnuauS AssiSt Sch. B2 (b5) 0
PeIcrIptlon or
Inold..... 6. Cau..
Unloading well lO..eonø stage.
HlgII TransR nn. p.....ure CGF 11885 lid for malnL
Hgh TrlNJt 11n. pfMaure OGF '1885 sid for main!.
Dnarip1lon at
InatdelllS .. c.lI$e
Deacrlp1Ian at
incidents .. Cøø
COR Reponing
(1) PnJ·authorlzadon requlr8d foe' naring Ind V8I'I1Ing wh.n tHUl1la wen belalllregularprcducdon
(b1)
(b2)
(b3)
(b4)
(b5)
(be)
(e)
!merJDp Up <11 No Tax
p~u. 11I0 TalC
Em.~1 NaTali
prill!.. <11&<5000 No Tax
IIIClSØ8N. 1.e8.. No TalC
AulPlorlZlld fix
Unau1h.NIule Tu/Penally
FEB 6'95 11:47
2,828
Iii'"
2PT
o
o
o
e
9075644094
e
AcIIon Te,*, to
EJimiRatw c....
SWildted _u blck to ""I.lage.
Area anø 'IX $/IuNR Gas rats
AICO and EIpJt Ilwt-ln a.. TII1II
Action TIn.. to
I!Ilmlna19 C....
Action TlIC8rI \Q
Eliminll18 C.UIMI
PAGE. 004
I spoke to John Hal Tucker at BP on June 12, 1995 about the following events that were
reported for January:
Gathering Center 1
01/15/95
Odd and even reboiler shutdown
The reboiler boils gas and oil. If the reboiler shuts down water condenses and they have 3
choices. They can send the gas to CGF. It would freeze in the inlets and this would cause
the whole field to shutdown. They can flare it. They can shut dow their facility, causeing a
loss in production, This is a rare occurrence and it's extremely rare for both of the
reboilers to shut down at the same time.
Gathering Center 2
01/02/95
High transit line pressure from higher ambient temperature.
This was an intermittent problem.
01/17/95
01/18/95
High gas line pressure due to CGF 1885 off-line
These events were both intermittent as well. They run close to the flaring point and have a
counter which counts the minutes a flare valve is open. They have cameras at the facilities
but only look at them for the black smoke, Cameras are not in production control center
and they are the ones who make the decisions to cut production. I asked if hey were
notified beforehand of the compressor problem and he said he didn't know, but that Arco
and BP have very good fieldwide communication.
Gathering Center 3
01/1 0/95
Unloading well to second stage
This was also another intermittent event. When a well is shut-in it loads with fluid. The
pressure drops 150-300 psi. If a well wont flow to the surface they can get the well into its
own line and get it to go to 2nd stage - 35 psi. then it would flow enough to get the load
fluid out. This doesn't happen very often and there is no gas lift on that particular pad.
e
e