Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutBPX - Sag Delta North ,~'w/¥..0f/.:d'~~rMr/AlrÆ:ß!Y#::tY/N'/AIž'&¥7.1/Ih!VAØVAr'~I/M"'#~W/'/I/#'K/E-:íW/I~AYl~hY'w/4'41P/I/'&øv#-'.4VAJ'P'AfYI'AØ"apZIW/..ofWM'.M'IAØ'YN/I/..;wAfl'7..v/I/..;wI/I/I/I/AV.MY..ofW.MYI/1/1/'/I/I/I/'áW;~V/N'{.7.M~:W::t,!~Ü¡·'~ "~iGOCC GaS DiS10SitioIl FLes - 1995 a1JX -$I (; ~''-TA - NO~TII - (;ff;:¡,W.;;(t-~.¡:;4IP4J~~~I,.{dP/I/AW~8/1/1/1/1/1/1/1/1/1/##/I/1/1-W/ßYßr~:~U/H.4Wfi?'w/MW/I/I/,E,.Ø'Y'/IAØ'YI/'/I/.,....,/,/,/g/ØAØ'YM#'#~"'o/Ø/K/A7..49Y.8WD/'/Ø/..øwN7A/.""/I/I/I/H4!IP/Áf..;t¡v,-:;¿¡¡:YÆ"'.~;/4I!:<:¡¡,::;¡f·~ ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott operator BP Exploration (Alaska) Inc. Field(S) Sag Delta North Disposition Volume MCF* I. Sold Fuel NGL o 220 2. Reinjected 5,150 - 3. Flared or vented less than I hour 19 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 50 5. Pilot and Purge 1 I 6. Used for lease operations Assist Fuel 27 6,790 7. Other TOTAL items 1-7 12,267 8. NGL gas equivalent produced 220 - 9. Purchased gas Kl::l#cj vt:D 10. Transferred from: JAN 1 0 1~96 11. Transferred to: ßja::';it.,,-j.,i¡~ .~ !\r I~~;'\ß:-~~:..j\', Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature eO. ~lt Title ~(( VÖL. Date t! ~¡í& Form 10-422 Rev. 4/95 Endicott 10450 Month/Year of Disposition December, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Official (;se On(y-¡';Iaring Authorization> I hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 1/4/96 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT December, 1995 Page 1 IUnplanned Events less than or equal to 1 hour TOTAL 12,282 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour 12/2/95 22:00-23: 10 5,195 MGC-B shutdown due to WHRU louver "valve out of MGC-B restarted. - position" . 12/3/95 00:00-01: 1 0 6,559 MGC-B shutdown due to WHRU louver "valve out of Louvers placed in manual service and MGC-B position" . restarted. Instrument techs installed "glitsch detector" to catch cause of louver failure. 12/7/95 15:30-16:40 142 Ambient temperature increased 3.3°F in 30 minutes Shut-in well 1-21. 12/9/95 02: 1 0-03:40 2,816 While attempting to jumper a known failed exhaust Bad thermocouple jumpered and MGC-B thermocouple, the MGC-B ESD was inadvertantly restarted tripped. 12/12/95 15:50-17:20 8,864 MGC-A shutdown on WHRU valve out of position. Switched WHRU to MGC-B; rebuilt louver position indicator, installed on MGC-A and restarted unit. 12/12/95 19: 1 0-20:40 455 Lining out production following MGC-A restart. 12/13/95 16:30-17:30 1,960 Gas leaked back through hydraulic equalization and Fluid packed balance and control lines and control lines from gas injection well 2-06 to the placed well 2-06 back in injection service. hydraulic return tank in Skid 410. The injection well e was shut in, resulting in gas flaring. 12/16/95 10:50-12:50 10,856 MGC-A shutdown due to power supply fuse blown Trouble shot for 2 hrs and not able to locate (short circuit). problem. Cut production to stop flaring during troubleshooting. Pulled card connectors, replaced fuse and reconnected cards one at a time to try to locate problem w/o success. Further investigation needed. 12/17/95 09:00-11 :00 5,392 Inadvertant total plant shutdown occurred while Error resulted from misinterpretation of the troubleshooting the UPS system to find the source of troubleshooting procedure. Consulted a power supply ground fault. manufacturer for clarification and held training courses for electricians to prevent a future occurrence. Restarted both MGCs. TOTAL 42,239 1/4/96 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT December, 1995 ·Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf e DATE TIME VOLUME 12/6/95 10:40-11 :10 240 12/8/95 04:00-04:20 237 12/8/95 17:10-17:50 870 12/9/95 23:00-23:30 134 12/11/95 09:40-10: 10 131 12/11/95 16:50-17:30 144 12/12/95 21 :30-22:00 218 12/13/95 01 :50-02:20 306 12/14/95 08:00-08: 1 0 126 12/17/95 00:20-01 :00 588 12/18/95 14:30-15:10 429 12/20/95 11:30-12:20 397 12/24/95 13:40-14:20 185 12/26/95 14:40-14:40 236 12/26/95 19:30-19:50 955 12/26/95 20:30-20:50 315 12/27/95 19:00-19:50 285 12/28/95 20:40-20:50 109 TOTAL 5,905 - ~~c~t;,i vt:D JAN 1 0 1~96 .- ,..' " <.~ ~p~:;i'~ii .m f~ Page 2 DESCRIPTION OF INCIDENT & CAUSE POP well 2-38. MGC-B shutdown for gearbox bearing replacement; bearing replacement required due to high vibration (normal wear and tear). POP well 2-14 POP well 1-03. POP well 1-25. POP well 1-21. Pressure up tubing on well 1-63 with lift gas to equalize pressure across sssv in order to re-open. POP well 1-25. Allow to gas off at reduced choke setting. Return 1-25 to production. Shut-in well 2-52. MGC-A idled to repair axial compressor bleed valve. Repairs completed and MGC-A re-Ioaded. Put well 2-26 on production. Put well 1-25 on production. Return well 3-09 to production following scale inhibition treatment. Shutdown MPI to allow repairs to eroded elbow in piperack. Restart MGC-A following MPI shutdown to repair piperack erosion. Continuing to bring MPI wells on production to fully load MGC-A Well 2-52 corrosion inhibitor treatment POP well 1-35. ACTION TAKEN TO ELIMINATE CAUSE Allow to gas off at reduced choke setting. Reduced production rates until flare was eliminated Shut-in wells 1-27 and 1-29 Allow to gas off. Allow to gas off. Reduce choke on well 1-25. Allow well to gas off. Allow to gas off at reduced choke setting. Allow to gas off at reduced choke setting. Shut-in all MPI production wells. Complete flowback at reduced choke; s/i 2-52 when done Allow well to gas off at reduced choke setting. 1/4/96 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT December, 1995 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf Shut-in well 2-28 to safe-out and inspect flowline check valve for possible erosion damage. Opened other wells to compensate. MGC-A shut down to repair ground fault problem. 12/3/95 04:20-05:20 328 12/17/95 16:00-17:00 4,287 e TOTAL 4,615 . < Page 3 Kept other wells at reduced choke until process swings settled out. Found the MGC-A ground fault source in conduit leading to bleed valve solenoid; replaced solenoid, coil, and wiring in conduit from coil to junction box in turbine enclosure. MGC-A restarted. TOTAL SDN ENDICOTT Volume flared less than 1 hour 18,187 19 18,168 Volume flared greater than 46,854 50 46,804 1 hour Pilot Purge 10,199 11 10,188 Assist Gas 25.835 27 25.808 e TOTAL FLARED VOLUME 101,075 107 100,968 ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION I Facility Endicott loperator BP Exploration (Alaska) Inc. Disposi tion 1. Sold Fuel NGL 2. Reinjected e 3. Flared or vented less than 1 hour 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations Assist Fuel 7. Other TOTAL items 1-7 8. NGL gas equivalent produced e 9. Purchased gas 10. Transferred from: 11. Transferred to: Remarks: I hereby certif/1hat the, foregoing is true Signature (.0. (~~ Form 10-422 Rev. 4/95 Volume MCF* 2,903 16 3,451 6,525 Field(S) Sag Delta North o 125 1 1 13 6 125 Title m&fl V6L and correct to the best of my knowledge. Date ~7..f~/qS' Endicott 10450 I Month/Year of Disposition November, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Officiäl Use Only-Flaring Authorization> 1 hr. I. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 12/5/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT November, 1995 IUnplanned Events less than or equal to 1 hour DATi+k ' ,! "¥iMÊ}l7 VOLUME D~SCRIPTION OF IN~tDENT & CAU'SE TOTAL 14,539 Not required for unplanned events which are less than or equal to 1 hour IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf ,DAT~/0F"i TIME V9LUME ,if ',DES'1RíIPTION OF INCIDErfi" &'CAUSE>40" 11/6/95 09:50-10:30 348 POP well 1-01 following downhole work 11/18/95 10:10-10:30 578 MGCA shut down to repair solenoid valve on axial compressor Loading up compressor after solenoid repairs POP 2-14 following downhole corrosion treatment POP well 2-18 following flowline spool replacement POP well 2-14 following flowline repairs IUnplanned Events greater than 1 hour DATE TIME VOLUME 11/1/95 01 :10-04:50 770 e 11/1/95 09:30-10:50 321 11/5/95 04:40-05:40 729 11/11/95 21 :30-22:50 284 11/21/95 09: 1 0-12:00 15,058 11/25/95 01: 1 0-02:20 117 11/25/95 04:20-05:30 90 11/26/95 07:00-08:50 665 11/26/95 19:10-20:10 249 e 11/28/95 21 :40-22:50 297 11/30/95 09:00-10:00 435 TOTAL 19,015 11/18/95 11/22/95 11/27/95 11/30/95 13:30-14:00 17:20-18:00 21 :00-21 :50 20:30-21:10 TOTAL 357 399 1045 622 3,349 ACTION TAKEN TO ELIMINATE CAUSE Reduced chokes on wells 1-29 and 1-35, finally SI well 1-35 to eliminate flaring Automatic load share system failed on compressors Machines put back into manual operation and gas rate reduced MGC antisurge problem resulting from a ground fault SI wells 1-21 and 2-40. Called out technician in a solenoid caused compressors to shed gas and solenoid valve repaired Ambient temp increased from 3-9F SI well 3-17 and then cut 1-27 to 95b and 1-25 to 55b Replaced thermocouples and attempted restart. Start up turbine dissengaged prematurely. Spin down MGC and started 2nd attempt. SI well 1-35 to reduce flared volume Cut wells 1-35 and 1-29 SI well 1-21 to eliminate flaring SI well 1-35 to eliminate flaring SI well 1-21 to eliminate flaring SI wells 1-21, 1-35 and 2-18, reduced choke on well 1-29 to 70b SI well 1-35 DESCRIPTION OF INCIDENT & CAUSE Ambient temp increased from 22 to 24F MGCB shut down due to turbine exhaust thermocouple failure Ambient temp increased from 8-12F Ambient temp increased from12-14F Ambient temp increased from 0-4F Ambient temp increased from 0-4F again Ambient temp increased from 12-22F Ambient temperatue increased from 4-6F Page 1 ACTION;i~WEN TO ELlMINATf;;,;ÇAUSE Not required for unplanned events which are less than or equal to 1 hour ~ .':"'f.' ACTION TAKEN,T:OEL¥lMÎNATE C~,W~$E ; None, allow well to gas off SI 8 wells to reduce flaring None, POP wells to provide gas to compressor Allow well to gas off. None, allow to gas off None, allow to gas off 12/5/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT November, 1995 Page 2 Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 11/16/95 13:10-14:40 299 POP wells 2-52 and 2-40 Allow to gas off, when flare was still ongoing for> 1 hour 81 well 1-25 and cut 1-29 to 75b. 11/17/95 15:50-17:40 884 POP wells 1-25 and 2-52 as ambient temps dropped Allowed to gas off. Then 81 3-03 to stop flaring. 11/17/95 18:00-19:00 1,881 "A" main compressor backed down to 80% to 81 well 1-25 to eliminate flaring e remove air keeping the compressor blow off valve closed. 11/22/95 15:50-16:50 313 POP well 2-52 A8 flare still open 81 well 2-52 TOTAL 3,377 Volume flared less than 1 hour ,)jOT AL . \¿ , 17,888 .. ~, SDN 11 ENDICOTT 17,877 Volume flared greater than 1 hour 22,392 13 22,379 Pilot Purge 9,870 6 9,864 e Assist Gas 27.347 16 27.331 TOTAL FLARED VOLUME 77,497 46 77,451 e e 't ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott loperator BP Exploration (Alaska) Inc. Disposition I. Sold Fuel NGL 2. Reinjected 3. Flared or vented less than 1 hour 4. Flared or vented greater than I hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations Assist Fuel 7. Other TOTAL items 1-7 8. NGL gas equivalent produced 9. Purchased gas r . ,.~ ... i-",-~ i ,. ~'n t,t 0 <} I ~....~ i"r' 10. Transferred from: 11. Transferred to: Alaska DB &. Gas (:C\r:1:;-;¡£:Icn Anchonga Remarks: I hereby certiJ1 t Signature k'. Volume MCF* 3,338 20 3,468 6,986 I Field( s) Sag Delta North o 129 15 9 7 129 Title f1A<..,fL V'ÖL and correct to the best of my knowledge. Date t¡{?{l1ú Form 10-422 Rev. 4/95 Endicott 10450 I Month/Year of Disposition October, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Official l:sc Only-rlaring Authorization> I hI'. I. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date - Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott Disposition 1. Sold 2. Reinjected e 3. Flared or vented less than 1 hour 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other 8. NGL gas equivalent :1' ~ en ~ ~ E. produced I2G >w :::I '" .. (f> gC? ~g m ~ TOTAL items 1-7 e 9. Purchased gas 10. Transferred from: C? <..D 3 CJ\ ê. .." (f> õ' :::I 11. Transferred to: Remarks: :i:::~:,,"rttlëô ili,t;::jj' Form 10-422 Rev. 4/95 operator BP Exploration (Alaska) Inc. Fuel NGL Assist Fuel ^' c....' r; -I ~ . " I - .. --' ,("") ...... r-n o Volume MCF* 5,172 35 6,225 11,578 Field(S) Sag Delta North o 77 34 23 12 77 and correct to the best of my knowledge. Title ~ VÜ! .UI?AÆ Date /,6 [ 'l(<1) Endicott 1 0450 I MonthlY ear of Disposition September, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Oftïci¡¡( Use Only-Flaring Authorization> I hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 10/4/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT September, 1995 Page 1 Unplanned Events less than or equal to 1 hour TOTAL 20,506 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour 9/8/95 13:10-14:50 - 7,459 9/19/95 07:50-09:10 542 9/19/95 18:20-20:00 448 9/21/95 13:00-14:30 668 9/30/95 01 :50-04:50 577 TOTAL 9,694 MGC-B shutdown due to WHRU exhaust louvers out The failed solenoid valve was replaced, the of position. The louvers failed to move properly due louvers repositioned & MGC-B was restarted. to a failed solenoid valve. The louver control logic was modified to prevent the WHRU & exhaust louvers from "modulating" such that the wear-and-tear on these solenoid valves should be reduced. Reduced rates on wells 1-21,1-27 and 2-36. Shut-in 1-01 & 2-58. Shut-in well 1-25. Ambient temperature climbed 1Q°F, during flaring period. Ambient temperature spikes bumping flare (ambient at z45°F). Ambient temperature climbed 13 degrees during flaring period. Intermittent flaring occurred while trying to maximize Shut-in well 2-18 at 0240. production rates; wells 2-18 and 1-25 were POP and allowed to gas off during this period. Shut-in wells 2-18, 1-21, 1-25 and 1-35. e .Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 9/1/95 17:40-17:50 9/2/95 15:50-16:40 9/3/95 13:20-13:40 9/15/95 08: 10-08:20 9/26/95 08:20-08:50 9/26/95 14:00-14:10 1174 Trip MGC-A to idle for antisurge control testing None; flaring required to monitor response of (CCC). antisurge valve. 1239 Antisurge control testing on MGC-A Flaring required to monitor response of antisurge valve; control logic modified to prevent future recycle trips. 2185 Compressor Controls Corp. antisurge control testing None; flaring required to monitor response of of MGC-A. antisurge valve. 152 POP well 2-68. Allow well to gas off (did in 20 minutes). 198 POP well 2-52 Reduce production on well 1-21; allow 2-52 to gas off. 117 POP 2-18 for State subsurface safety valve test. Shut-in well 1-21. 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 9/11/95 01 :40-03:50 3,129 Depressure and purge gas plant and flare system for None. Required for safe plant shutdown. plant shutdown to replace flare tip. Relight flare following planned plant shutdown for flare tip replacement; keep flare lit while attempting to restart an MGC. Bringing on production in preparation of MGC-A start-up. Startup NGL plant; additional backpressure on gas Reduce rates on 4-10 and 1-61. system reduces effective gas handling capacity. POP well 2-52 at 50 beans and allow to gas off (@2115). POP well 1-25 & allow to gas off. 10/4/95 9/28/95 09:20-10:00 1032 9/28/95 14:00-14:10 TOTAL 142 6,239 - 9/12/95 10:10-13:00 1,554 9/12/95 18:30-19:30 1,574 9/16/95 00:10-01:10 220 9/17/95 21 :30-22:30 134 9/25/95 20:50-21 :50 367 9/28/95 15:10-16:30 608 9/28/95 16:50-18:20 395 It 9/29/95 01:40-03:10 308 9/30/95 08:20-09:40 564 9/30/95 12:00-13:10 125 TOTAL 8,978 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT September, 1995 Page 2 Shut-in gas injection well 2-06 for State subsurface 2-06 passed test and returned to injection safety valve test. service. POP 1-29 for State subsurface safety valve test. Shut-in 1-29. Reduced production rate on 2-46 (one of only two wells flowing to plant). Restarted MGC-B and failed attempts at starting MGC-A. MGC-A startup delayed; Shut-in well 1-35. Choke 2-52 back at 2225; shut-in at 2235. Well did not gas off within one hour; ultimately shut-in. Reduced production on neighboring well after 40 minutes to minimize flaring. Well 1-05 passed test and returned to injection service. Well did not gas off within one hour; shut-in well 2-08 at 0200; ultimately shut-in 1-25 at 0310. POP 1-09 and allow to gas off; also, State witness of Shut-in wells 1-09 and 1-25. k-valve closure test on well 1-21. Start gas lift to well 1-31 ; allow to unload and stabilize. POP well 2-36 and allow to gas off. Shut-in gas injection well 1-05 for State subsurface safety valve test POP well 1-25 & allow to gas off. Shut-in well 1-25. 10/4/95 BP EXPLORATION (ALASKA) INC. Page 3 ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Septem ber, 1995 TOTAL SDN ENDICOTT Volume flared less than 1 hour 26,745 34 26,711 Volume flared greater than 18,672 23 18,649 1 hour Pilot Purge 9,870 12 9,858 e Assist Gas 27.753 35 27.718 TOTAL FLARED VOLUME 83,040 104 82,936 e - e ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott operator BP Exploration (Alaska) Inc. I Field( s) Sag Delta North Disposition Volume MCF* I. Sold Fuel NGL o o 2. Reinjected 6,580 3. Flared or vented less than 1 hour 14 4. Flared or vented greater than I hour (Supplemental report required--See 20 AAC 25.235) 14 5. Pilot and Purge 14 6. Used for lease operations Assist Fuel 41 7,547 7. Other TOTAL items 1-7 14,210 8. NGL gas equivalent produced o 9. Purchased gas 10. Transferred from: 11. Transferred to: Remarks: I hereby cert~ th/'¡the f. oregoing i~ true and correct to the best of my knowledge. Signature /¿. (lv~ Title (V1,0(L V¿)~ Date 1.17 ['1,<..,- Form 10-422 Rev. 4/95 Endicott 10450 Month/Year of Disposition August, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Official ¡;~C Only-Haring Authorizat.ion> I hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 9/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT August, 1995 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE TOTAL 8,842 Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE TIME VOLUME - 8/16/95 13:10-14:30 570 8/18/95 2:50-4:40 388 8/18/95 10:30-11 :30 354 8/18/95 19:20-20:20 150 8/22/95 18:30-19:30 5,109 TOTAL 6,571 DESCRIPTION OF INCIDENT & CAUSE Gas injection well 2-06 shut-in for gas leak repair. Leak was on valve packing in 2-inch bypass around flow control valve. High ambient temp. swings caused intermittent flaring & forced a reduction in production rates. Ambient temp up 5°F. High ambient temp. swings caused intermittent flaring & forced a reduction in production rates. Ambient temp up 5°F. High ambient temp. swings caused intermittent flaring & forced a reduction in production rates. Ambient temp up 6°F. MGC-B shutdown due to a failure of the solenoid valve that operates the WHRU exhaust damper (resulted in a 'valve out of position' shutdown). Page 1 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Reduced production within 30 minutes of identifying problem. Repacked 2-inch valve and returned well 2-06 to service. Reduced choke on wells 1-63 and 1-35 Reduced production from wells 1-29, 3-17 and 2-04. Reduced production from well 2-04 Maintenance technicians changed out the failed solenoid valve and MGC-B was restarted. e IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 8/3/95 21 :10-21 :20 965 Weekly flare test. None. Safety requirement. 8/18/95 7:50-8:00 54 POP well 3-17. Allow to gas off. Shut-in well 1-29 for corrosion inhibitor 8/19/95 13:50-14:30 371 POP well 1-55 following corrosion inhibitor treatment treatment TOTAL 1,390 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 8/6/95 13:30-14:30 287 POP well 1-39 and allow to gas off. ACTION TAKEN TO ELIMINATE CAUSE Reduce choke on wells 1-35 and 2-52 (ultimately shut-in 2-52). 9/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT August, 1995 Page 2 8/23/95 17:40-19:10 TOTAL 3,156 3,443 Flared to trouble shoot problem with flare tip (apparent leak at base of tip). Plant shutdown on high 1 st stage pressure. Brought MPI & SDI well back on production. None. Flaring was required to troubleshoot problem with flare system. Testing of flare tip was completed. - TOTAL SDN" . ENDICOTT Volume flared less than 1 hour 10,232 14 10,218 Volume flared greater than 10,014 14 1 0,000 1 hour Pilot Purge 1 0,199 14 10,185 Assist Gas 29.810 41 29.769 TOTAL FLARED VOLUME 60,255 83 60,172 e ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott operator BP Exploration (Alaska) Inc. Field(S) Sag Delta North Disposition Volume MCF* 1. Sold Fuel NGL o 21 2. Reinjected 6,548 e 3. Flared or vented less than 1 hour 27 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 6 5. Pilot and Purge 14 6. Used for lease operations Assist Fuel 46 6,507 7. Other TOTAL items 1-7 13,169 8. NGL gas equivalent produced 2 I e 9. Purchased gas R r " ~ '.,,' F D AUG 1 0 1995 10. Transferred from: 11. Transferred to: AiaSka 011 & Gas Cons. Commission Anchgrage Remarks: I hereby certi~hat the 7egOing is true and correct to the best of my knowledge. Signature fi. Q. Ilh~ ÅTitle (hf:.tZ VI:) L Date Ô h I ~S- Form 10-422 Rev. 4/95 Endicott 10450 I Month/Year of Disposition July, 1995 I *Indicate contribution of each pool to total. Pool Name Code 220150 Percent Official LSC Only-Flaring Authorization> I hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 8/4/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT July, 1995 Page 1 Unplanned Events less than or equal to 1 hour TOTAL 13,941 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE TIME' VOIjØME 896 DESCRIPTMfIb~~QiNT &~e.USE ' "~;,;: High ambient temp. swings caused intermittent flaring & forced a reduction in prod. Ambient temp up 6°F ,~~jiJØØ"~EN TO ELIMINATE CAUSE e 7/2/95 9:10-10:20 Bypassed NGL plant to increase plant gas throughput; reduce choke on well 2-36 7/11/95 14:40-16:40 TOTAL 1,952 2,848 1 st stage anti-surge control problem with MGC-A; control valve opening abruptly to prevent compressor surge, but resulting in process destabilization and flaring Attempt to duplicate anti-surge control problem in order to identify cause; unsuccessful, so production rates were reduced starting at 1550 hours and the controller was changed out Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 7/4/95 4:00-4:30 107 POP well 1-25 Shut-in wells 1-21 and 1-67 7/4/95 17:00-17:10 266 Ramp down MGC-A for MGC-B restart attempt MGC-B restart failed; fully load MGC-A 7/4/95 18:00-18:00 203 Ramp down MGC-A for MGC-B restart attempt Restart MGC-B 7/5/95 4:50-5:30 588 POP wells 2-04 and 2-08 Allow wells to gas off e 7/5/95 10:00-10:40 189 POP well 1-01 Rf :;\,'ED Reduce chokes on wells 1-35 and 4-38 7/5/95 11 :00-11 :20 136 POP well 3-21 Shut-in well 1-17 7/6/95 13:00-13:40 406 POP 2-40 AUG 1 0 1995 Shut-in well 2-40 7/9/95 7:40-8: 1 0 163 POP well 2-04 Reduce chokes on wells 1-27 and 1-29 7/10/95 7:30-7:40 63 POP well 1-21 ~~iI ~¡~ons C .. Allow well to gas off 7/11/95 2:40-3:00 137 Increasing rates t 0 ß,r ra ~ ommlSSIOn Allow wells to gas off 7/11/95 19:20-19:40 271 Begin loading MGC-A g Bring MGC-A to full speed 7/12/95 11 :20-12:00 231 POP well 1-63 Shut-in well 2-40; allow well 1-63 to gas off Complete adjustment; return to normal 7/13/95 8:40-9:00 116 Adjust MGC-A A/S control set point operation 7/16/95 21 :40-22:00 330 Attempt to test well 1-21 k-valve Test failed; bleed off remaining pressure 7/17/95 11 :20-11 :30 216 Test k-valve on well 1-21 Complete test; leave well shut-in 7/17/95 20:30-20:50 149 POP 2-04 Allow well to gas off 7/18/95 11 :50-12:10 75 Run Copus start-up compressor to start MGC-A Successfully start and speed up MGC-A 8/4/95 7/18/95 14:30-14:40 7/19/95 4:30-5: 10 7/25/95 16:30-17:20 7/31/95 8:40-8:40 e 7/31/95 9:20-9:40 TOTAL 168 318 1499 84 477 6,192 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT July, 1995 Return MPI wells to production following high-flow test separator block valve repair POP well 2-04 Take MGC-A down to work on 1 st stage anti-surge valve 1 st stage separator pressure control valve function testing 1 st stage separator pressure control valve function testing Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf Page 2 Fully load "A" Main Gas Compressor Too much gas; shut-in well 2-04 Reload MGC-A Flaring required during function testing Flaring required during function testing 7/1/95 7/2/95 17:10-18:30 7:50-8:50 7/5/95 8:00-9:20 TOTAL e Volume flared less than 1 hour Volume flared greater than 1 hour Pilot Purge Assist Gas TOTAL FLARED VOLUME 483 414 485 1,382 Adjusting choke on well 2-36 during sand monitoring work to attempt to identify cause of well line erosion Complete sand monitoring POP well 1-25; ambient temp up 2°F Shut-in well 1-35 and 2-18. Attempting to return wells to full production after shutdown yesterday caused flaring and process upset until those wells were stabilized. Ambient temp also up 4°F Reduced chokes on wells 3-15,1-25 and 1-67; shut-in well 3-03 TOTAL SDN ENDICOTT 20,133 27 20,106 4,230 R r; wED 6 4,224 ..... 10,199 AUG 1 0 1995 14 10,185 Alaska Oil & Gas Cons Co . 34.528 Anchorag~ mmlSSfon 46 34.482 69,090 93 68,997 :" ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott Operator BP Exploration (Alaska) Inc. Field(S) Endicott 10450 Month/Year of Disposition Sag Delta North June, 1995 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold Fuel NGL o 185 Pool Name Code 220150 Percent 2. Reinjected 9,672 e 3. Flared or vented less than 1 hour 33 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 56 5. Pilot and Purge 17 Official l;sc Only-Flaring AUlhori7alion>1 hI'. 6. Used for lease operations Assist Fuel 61 7,907 1. Safety MCF 7. Other 2. Lease MCF TOTAL items 1-7 17,931 3. Conserv. Purposes MCF 8. NGL gas equivalent produced 185 e 9. Purchased gas Commissioner Date 10. Transferred from: 11. Transferred to: Title (hG(l 0Jy!VOL Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. Remarks: I hereby cer~y that the foregoing is Signature II.G, ~1k true and correct to the best of my knowledge. Date 7 f¡ol'tr Form 10-422 Rev. 4/95 7/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT June, 1995 IUnpla"ned Events less than or equal to 1 hour DATETIMEf . VOL:UI\iIE"':ii,;;!'DESC~IPTIOfI¡J<dF,INCI[)ENr08lcAUSE .' TOTAL 15,202 Not required' for unplanned events which are less than or equal to 1 hour Iunplanned Events greater than 1 hour DATE TIME VOLUME· e 6/3/95 18:00-19:10 140 617/95 7:20-10:20 859 6/9/95 10:10-11 :20 1,145 6/10/95 11 :20-12:20 310 6/10/95 8:10-10:00 510 6/11/95 15:10-16:20 957 6/11/95 18:30-20:00 747 e 6/12/95 9:00-10:50 174 6/19/95 18:20-19:40 555 6/19/95 21 :20-22:20 197 6/21/95 8:40-10:30 735 6/23/95 1 :00-3:30 422 TOTAL 6,751 ,DESCRIPTION OF INCIDENT & CAUSE MGC-B WHRU dampeners would not open, well 4- 10 POP following essential well head maintenance Increasing ambient temp (4 deg in 3 hours) caused 1 st stage pressure to rise Increasing ambient temp (10 deg in 4 hours) combined with unplanned shutdown and repair of Repaired injection pumps shut in several both water injection pumps caused plant to be producing wells to minimize/eliminate flare unstable for most of the day (total impacts for the day were 4250 bbls of oil) Increasing ambient temp (2 deg in hour) caused 1st stage pressure to rise Shut in well 2-40 to eliminate flare Increasing ambient temp (3 deg in 2 hours) caused 1 st stage pressure to rise Flaring caused by control problems with anti-surge. Flaring caused by control problems with anti-surge. PW pump SID causing plant upset. Increasing ambient temperature caused 1 st stage pressure to rise Increasing ambient temperature caused 1 st stage pressure to rise MGC-A recycle trip occurred at same time as POP well 1-29 MGC-A 3rd stage Fin fan shut down : Page 1 . iACTION':TA!<EN,Tb~E:l;liûlINÄtE!~¡!tAUSE~~:i~;,i Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELlMINATE,cAUSE Repaired dampeners and cut well chokes to eliminate flaring. Wells 1-25 and 2-08 cut to eliminate flare Wells 1-25 and 2-08 cut to eliminate flare New control constants installed following discussions with Turbine manufacturer New control constants installed following discussions with Turbine manufacturer Cut production to eliminate flaring Well 1-25 cut to eliminate flare Well 1-25 cut to eliminate flare Shut in well 1-25 Fan repaired and wells 1-35/1-67 shut in to eliminate flare IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf '. DATE .. TIMê,.'.·:iii¡'i" VOLUME ',:öE;§:<:;~1~itI9N qf.INC.IDENT:'& CAU~.E:¡{t'!::.!,;<:: '~.. ····~;ri;·ÄCTIOr'<l,..:rA (EN':TO .E~I~!NÅ1~'Ç'AU§E::,i:¡;~il;:i"~·\~"i Hi9h 1st stage pressure resulted in MPI well shut Manually tripped MGC-A to idle to maintain 6/6/95 16: 10-16:50 799 down pressure 7/7 /95 6/6/95 17:30-18:00 6/6/95 8:20-9:00 6/7/95 15:00-15:30 6/9/95 7:00-7:50 6/9/95 8:50-9:30 e 6/12/95 11 :50-12:40 6/13/95 19:50-20: 10 6/13/95 22:00-22:50 6/20/95 13:20-14:00 6/24/95 17:10-18:00 TOTAL 423 241 310 436 195 176 269 100 448 106 3,503 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT June, 1995 High 1 st stage pressure resulted in MPI well shut down POP well 2-68 Bypassed NGL plant POP well 2-18 Open well 2-18 Essential well head maintenance necessitated shutting in and then POP'ing wells 1-21, 1-25, 2-42, 2-60 and 3-27 Well 4-20 put on production and plant started to receive slugs. Well 4-20 put on production and plant started to receive slugs. POP well 1-01 following well work POP well 1-01 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME' VOt:tJME\:¡>9t.:¡:F:¡lpES(:RIPTldN"!'OF INC.IDENT & CAUSE 6/1/95 16:40-17:40 e 6/2/95 22:10-23:50 201 392 POP well 2-40 POP well 2-40 Control problems with compressor anti-surge 6/11/95 10:00-14:50 19,598 controllers. Essential well head maintenance necessitated shutting in and then POP'ing wells 1-21, 1-25, 2-42, 6/12/95 13:00-14:00 235 2-60 and 3-27 Well 4-20 put on production and plant started to 6/13/95 18:20-19:30 260 receive slugs. Following well work well 4-20 was POP, resulting slugs from SOl caused significant swings in 1 st 6/13/95 20:40-21 :40 127 stage levels and pressure ~ Page 2 Manually tripped MGC-A to idle to maintain pressure Allow to gas off slowly Reduced choke on well 1-21 to eliminate flaring SI well 1-57 to eliminate flaring Shut in well 1-25 to eliminate flaring Minimized flare by reducing adjacent wells and POP treated wells slowly Increased Lift gas to SOl to stabilize line Increased Lift gas to SOl to stabilize line POP slowly to allow well to gas off SI well 1-35 ,. ACTION TAKENTO'~~U\I!IN~J¡~\~At.:JSE;~· ':~" Reduced adjacent well chokes to eliminate flare Reduced adjacent well chokes to eliminate flare New control constants installed following discussions with Turbine manufacturer. Wells were reduced to limit flaring while maintaining some load on the compressor to function check new controllers/transmitters Minimized flare by reducing adjacent wells and POP treated wells slowly Increased Lift gas to SOl to stabilize line ~. ..~ Increased Lift gas to SOl to stabilize line . . 7/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT June, 1995 Page 3 6/16/95 9:50-11 :00 438 Well 2-08 POP following well work Shut in wells 1-21 and 1-67 to eliminate flaring Displacing interisland water line with gas in 6/22/95 18:10-19:30 223 preparation for 'intelligent pig' inspection Well 1-25 gradually reduced then shut in Displacing interisland water line with gas in 6/22/95 19:50-21 :00 710 preparation for 'intelligent pig' inspection Well 1-25 gradually reduced then shut in Inter-island water line was inspected using intelligent PIG displaced with gas routed back to the 1 st stage Well 1-35 was gradually cut, then shut in to - 6/23/95 11 :00-12:50 472 separator eliminate flare Reduced chokes on wells 1-29, 1-63 and 2-36. 6/24/95 20:40-22:20 346 POP well 1-25 Then again Shut in well 1-25 to eliminate flare None, in pre-activity safety review this Flaring at SOl to depressure inter-island water line operation was deemed as the safest way to 6/24/95 19:00-24:00 234 following 'intelligent pig' inspection reduce line pressure in order to recover pig. Shut in well 1-29 for State required pressure survey POP well 1-25 to make up for loss and allowed 6/26/95 7:00-8:30 404 logs to gas off slowly Two wells restQred to production following flowline 6/28/95 19:20-20:40 1,287 repairs Adjacent wells cut back to eliminate flare TOTAL 24,927 e TOTAL SDN 'ENDICOTT Volume flared less than 1 hour 18,705 33 18,672 Volume flared greater than 31,678 56 31,622 1 hour Pilot Purge 9,870 17 9,853 Assist Gas 34.792 61 34.731 TOTAL FLARED VOLUME 95,045 167 94,878 Facility Endicott I. Sold 2. Reinjected e ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION operator BP Exploration (Alaska) Inc. Disposition Volume MCF* Fuel NGL 10,721 3. Flared or vented less than 1 hour 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other Assist Fuel 94 10,718 TOTAL items 1-7 t: 0 "w W VI "Ë f."LJ t..o E en <:> ....... m (; -- ....... Q, (.'; C::1 ....- r:: (;$ LU ~:; "'. N wO U .~ -£ c.c: iB,¿ LW <C eð rv 2 ë5 ~ ro <U ::¡: 21,900 e 8. NGL gas equivalent produced 9. Purchased gas 10. Transferred from: II. Transferred to: Remarks: I hereby cer1{ Signature ((. Form 10-422 Rev. 4/95 I Field(s) Sag Delta North o 194 45 105 23 194 Title ()1.Grl.. v'òL- and correct to the best of my knowledge. Date C(r..e[q$" Endicott 10450 I MonthlY ear of Disposition May, 1995 *lndicate contribution of each pool to total. Pool Name Code 220150 Percent Official Use Only-Flaring Authorization>l hr. 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 6/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT May, 1995 Page 1 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE TOTAL 15,443 Not required for unplanned events which are less than or equal to 1 hour ACTION. TAKEN TO ELIMINATE CAUSE; Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE ~AUSE 5/11/95 22:30-23:50 5,046 Main compressor shut down due to WHRU alarm Switched WHRU to other compressor e 5/12/95 5:40-8: 10 650 Plant upset due to slugging into separation train Stabilized facility process and operation 5/12/95 13:10-14:10 386 Well treatment flowbacks upset plant stability Stabilized facility process and operation 5/14/95 13:20-14:20 211 Ambient temperature swings affected plant stability Stabilized facility process and operation 5/14/95 16:40-18:10 423 Ambient temperature swings affected plant stability Stabilized facility process and operation 5/15/95 8:50-10:00 1,029 Well 1-67 shut in due to SSSV closure Stabilized facility process and operation 5/16/95 13:50-15:30 400 Well treatments caused plant upset and hence flare Stabilized facility process and operation to open 5/18/95 18:10-20:10 4,753 Plant shut down due to water handling problems Brought plant back on line e 5/21/95 13:20-15:10 7,056 MGC 'A' shutdown due to high bearing temperature Replaced bearing thermocouple alarm 5/21/95 21 :20-23:50 11,062 Attempting to restart MGC 'A' after machine failure Essential maintenance completed 5/22/95 20:50-22:00 643 Booster compressor shut down, plant de-stabilized Switched to back up booster compressor 5/26/95 18:20-20:20 975 Ambient temperature swings affected plant stability Stabilized facility process and operation 5/27/95 14:30-15:50 402 Ambient temperature swings affected plant stability Stabilized facility process and operation 5/28/95 13:50-15:30 676 Ambient temperature swings affected plant stability Stabilized facility process and operation TOTAL 33,712 6/7/95 BP EXPLORATION (ALASKA) INC. Page 2 ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT May, 1995 IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME ' "DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5f7 /95 18:00-18:10 44 Weekly Flare test None, safety requirement. 5/9/95 0:50-1 :20 609 Optimizing rate during compressor overhaul Stabilized facility process and operation 5/9/95 2:10-2:40 408 Optimizing rate during compressor overhaul Stabilized facility process and operation e 5/9/95 3:00-3:50 206 Optimizing rate during compressor overhaul Stabilized facility process and operation 5/9/95 5:00-5:20 338 Optimizing rate during compressor repair Stabilized facility process and operation 5/9/95 16:20-16:50 29 Optimizing rate during compressor overhaul Stabilized facility process and operation 5/16/95 11 :00-11 :20 357 POP well 1-67 and allow to gas off Stabilized facility process and operation 5/19/95 3:40-4:30 561 Start main compressor following overhaul Stabilized facility process and operation 5/22/95 1 :30-2:00 201 Optimizing rate during compressor repair Stabilized facility process and operation 5/23/95 3:00-3:50 638 Gas flared during loading of compressor during Stabilized facility process and operation 5/23/95 8:30-9:20 139 Optimizing rate during compressor overhaul Stabilized facility process and operation e 5/26/95 14:10-15:00 98 Ambient temperature swings affected plant stability Stabilized facility process and operation 5/29/95 5:40-6:00 39 Optimizing rate to TAPS proration levels Stabilized facility process and operation 5/29/95 12:10-12:10 110 Optimizing rate to TAPS proration levels Stabilized facility process and operation 5/29/95 13:30-13:30 137 Optimizing rate to TAPS proration levels Stabilized facility process and operation 5/29/95 14:20-14:30 263 Optimizing rate to TAPS proration levels Stabilized facility process and operation 5/29/95 17:40-17:50 42 Optimizing rate to TAPS proration levels Stabilized facility process and operation TOTAL 4,219 6/7 /95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT· ENDICOTT May, 1995 Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME .' DESCRIPTION OF INCII?ENT &.CAUSE 5/3/95 14:20-15:20 213 POP well 2-42 following well work 5/9/95 6:40-7:40 130 5/9/95 8:20-10:50 870 e 5/10/95 17:30-20:30 3,492 5/12/95 1:10-2:20 504 5/13/95 16:30-19:30 739 5/13/95 19:50-21 :20 315 5/14/95 5:10-7:50 1,098 5/15/95 16:50-18:20 951 e 5/15/95 18:40-21 :20 1,059 l' .If)} ^ 5/16/95 . ('4'f.-Q:00-1 :20 197 . ..... 4.{.., 4:1'A '" <<(~./~ f "û't. '''~j) / l .. ·'f~,.. t/'. ¡,r,,_:'\ '<@cf%/95 ¿> 18:104~ 600 ""l"v" /.'"1 5/~&~~Z,~ 'r~~0-14:50 934 , (;h?' (~';Z~;i-,. t--,/., 5/27/95 2:t''ê-3:10 565 5/29/95 18:20-19:50 772 MGC 'A' shut down for maintenance,optimize rate on 1 compressor MGC 'A' shut down for maintenance,optimize rate on 1 compressor POP wells 2-04 & 1-27 to prepare for Compressor restart Optimizing rate during compressor overhaul Water wash gas injection wells Water wash gas injection wells Turbine wash of main gas compressors Adjusting temperature control logic on MGC 'B' Adjusting temperature control logic on MGC 'B' Optimizing rate following MGC 'B' control logic change POP well 1-29 and 2-20 following well work Page 3 ACTION TAKEN TO EtIMINATE.CAUSE Stabilized facility process and operation Stabilized facility process and operation Essential maintenance completed Stabilized facility process and operation Stabilized facility process and operation Stabilized facility process and operation Stabilized facility process and operation Essential maintenance completed Essential maintenance completed Essential maintenance completed Essential maintenance completed Stabilized facility process and operation SI well 1-29 for Rig Move, POP well 1-55 and allow Stabilized facility process and operation to gas off Optimizing compressor performance Wells gassing off after TAPS slowdown. Equipment testing completed Stabilized facility process and operation 6/7/95 5/30/95 5/30/95 e 11:50-13:20 20:20-21 :30 TOTAL Volume flared less than 1 hour Volume flared greater than 1 hour Pilot Purge Assist Gas TOTAL FLARED VOLUME e BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT May, 1995 Page 4 268 Stabilized facility process and operation Shut in well 1-29, attempted to make up rate with other wells 374 POP new well 3-37. Gas rate initially contiunued to Stabilized facility process and operation rise. 13,081 TOTAL SDN· END'ICOTT 19,662 45 19,617 46,793 105 46,688 10,199 23 10,176 41.609 94 41.515 118,263 267 117,996 ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott Operator BP Exploration (Alaska) Inc. Disposition Field(s) Endicott 10450 Month/Year of Disposition Sag Delta North April, 1995 Volume MCF* *If production comes from multiple pools, indicate contribution of each pool to total. I. Sold e 2. Reinjected 3. Flared or vented less than I hour 'L: o ~¡;) (,? 'Ë E (..) (...) I..::) f.J~! (.0 <:1'> c:.."? .-- 4. Flared or vented greater than I hour (Supplemental report required--See 20 AAC 25.235) :::~ . , . f...e;...,,.' ç, 5. Pilot and Purge t (" 6. Used for lease operations 7. Other NGL Gas Equivalent Assist Gas e TOTAL Pool Percent o 220150 6,374 I 3 6 I 3 Use Only-flaring Authorization> J hr. 6,441 I. Safety MCF 235 38 2. Lease MCF 13,120 3. Conserv. Purposes MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.253 Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Q.QL~_ Title Ybd~t1._&ç;\Ll~-"!J\ßlli~ Date: _~/'i..r Form 10-422 Rev. 11194 5/5/95 IUnplanned Events less than or equal to 1 hour BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT April, 1995 Page 1 events are less than or equal to 1 hour fUnplanned Events greater than 1 hour Not events are less than or equal to 1 hour 0700-0810 228 e 4/6/95 1150-1320 246 4/9/95 2010-2140 348 4/17/95 1210-1350 574 4/20/95 1540-1640 213 4/25/95 1350-1540 409 4/26/95 0640-0830 836 TOTAL 2,854 Ambient temperatures caused flare valve to open production to Ambient temperatures caused flare valve to open Cut production to avoid flaring Compressor anti-surge control problems led to flare Blocked in GL header valve on MGC'A' event Ambient temperatures caused flare valve to open Cut production to avoid flaring Attempting to limit production to TAPS proration levels Ambient temperatures caused flare valve to open Cut production to avoid flaring Ambient temperatures caused flare valve to open Cut production to avoid flaring e IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mef 2120-2200 109 Put well 2-52 on production 4/16/95 1320-1400 486 Bypass Chiller to assess compressor performance None, equipment function test. 4/22/95 1910-1920 833 Second stage flare test. None, safety requirement TOTAL 1,428 " 5/5/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT April, 1995 Page 2 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 151 610 1510-1610 1810-1930 out on own Cut rate to eliminate flaring None, Safety requirement 4/14/95 4/16/95 175 264 1,256 Brought wells on, allowed to gas off. Put well 2-50 on production. Allowed to gas off Routine Flare Test TOTAL 1,695 - SDN ENDICOTT 10,223 13 10,210 4,549 6 4,543 if' 9,870 13 9,857 29.824 38 29.786 54,466 70 54,396 Volume flared less than 1 hour Volume flared greater than 1 hour Pilot Purge Assist Gas TOTAL FLARED VOLUME - /'/\ f'~ é" ~ " "'" (#d"\ ft.... ; . /'j :t':..,....... .é\ ."') C' "~w ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott Operator BP Exploration (Alaska) Inc. Disposition 1. Sold e 2. Reinjected 3. Flared or vented less than I hour o f..LJ 4. Flared or vented greater than I hour....... (Supplemental report required--See 20 AAC 25.235) .-P" 5. Pilot and Purge U.J '"..; L.LJ CL 6. Used for lease operations 7. Other e Note; All NGL Gas Equivalent Assist Gas TOTAL '. Field(s) Endicott 10450 MonthlYear of Disposition Sag Delta North March, 1995 Volume MCF* l..O cn c:!'ì ...-- ~ (:) ·r..) tf) 'f: E (,;) Q . n, f'l) I'^~ r: ;j 8~ ~i ~g 0<t ct\ *If production comes from multiple pools, indicate contribution of each pool to total. Pool Percent N 0: .<f' ~: o ~' ~,;¡ o 220150 9,705 1 6 17 -- ..... ,."-----.'.- Official Use Only-Flaring Authorization> 1 hr, 8,896 1. Safety MCF 330 47 2. Lease MCF 19,012 3. Conserv. Purposes MCF volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.253 Remarks: : i:~:~:"ce'Q (it ~"::d Form 10-422 Rev. 11194 i correct to the best of my knowledge. Ti tie {Y1G'(L---VOL.l~t::."'4f!.,Qý-/J(1..l1¥-____-- Date: -'1tlLl'1.f' 417195 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT March, 1995 IUnplanned Events less than or equal to 1 hour "::t:l"TIME.:Y:~l;')',:-:~t ~<,ç~~ ¿)VOLiUME DESCRIPTION,Of,INCIDENT&.CAUSE: 'ii' TOTAL 6,543 Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE . TIME .,' ';,A\';:<sVOLUME TOTAL 0 '. DESCRIPTION OF. INCIDENT & CAUSE! , e [Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE· TIME' 'i ?~. .òU~: VOLUME-. DESCRIPTI0t:l OF;lNCIDENT & CAUSE ,!, , ',1./ 3/5/95 1640-1650 619 Perform weekly test of the high pressure flare 3f1/95 1320-1400 259 Put well 2-42 on production 3/9/95 1330-141 0 816 Put well 2-52 on production 3/12/95 1740-1750 487 Perform weekly test of the high pressure flare 3/19/95 1200-1300 191 Begin underream & flowback of well 3-39 3/21/95 2100-2120 119 MGC-B startup following exhaust thermocouple e 3/26/95 1910-1920 539 Perform weekly test of the high pressure flare 3/31/95 2230-2300 180 Put well 2-32 on production TOTAL 3,210 Page 1 ACTIONTAKENTOiELIMINATE.CAUSE...······ hi" '.' Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE: ' ,; '" ACTIQN T A (ENTQELlMINATE;~AlJSE!)iF None; safety requirement ;':,·..'..i'·".···:·.', è/"Y__::Ù':::'? Allow well to gas off at reduced choke setting See above None; safety requirement Adjust other wells to minimize flare volume Small flare volume required by Copus slu turbine None; safety requirement Allow well to gas off at reduced choke setting 4/7 195 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO, 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT March, 1995 Page 2 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf ibATETIME " ~·;;¡;iiVÓ(:(JMEI~11Iitjit:>~§þRìPtlº!iJ;t>f;ilNcl_DgNT;&Ç~(J$I:;¡~t·,;¿ 3/10/95 1310-1440 484 I Put well 2-46 on production TOTAL 484 {::,::~~ /iÚt;:::,'8:t\r . ACTIÞN;TA.KENTC).ELÎMí!iJA T¡:ÇAUSE§~.;~~j.if· ,. Allow well to gas off at reduced choke setting - w>:'*""~ TOTAL SDN ENDICQTT, Volume flared less than 1 hour 9,753 16 9,737 Volume flared greater than 484 483 1 hour Pilot Purge 10,199 17 10,182 Assist Gas 29.013 47 28.966 TOTAL FLARED VOLUME 49,449 81 49,368 e "t~, \}f ~1?' #ç:> ¿ 1 '(,.1-.. ~'r.A¡) -"/.... '.1' C~-:~'~ ,J > \';"(': /' -'(7, ~., '~;:;\:;~~~ l':r;-" .~. ,.? .. ·{i.h· 'i.;> /\, ~#~~ .. " <~~,. ., <~) ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Endicott Operator BP Exploration <Alaska) Inc. Field(s) Endicott 10450 Month/Year of Disposition Sag Delta North February, 1995 Disposition Volume MCF* *If production comes from multiple pools, indicate contribution of each pool to total. Pool Percent I. Sold o 220150 e 2. Reinjected 3,342 3. Flared or vented less than I hour I I 4. Flared or vented greater than I hour (Supplemental report required--See 20 AAC 250f<> E eEl V E D 5. Pilot and Purge I 2 4 Official Use 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF MA.n 2 1 1996 6. Used for lease operations . . . Alaska OH & Gas Cens. Ccmm¡SSlon An¡;hu Ci\J1:: 1,269 7. Other NGL Gas Equivalent Assist Gas 83 10 e TOTAL 4,731 Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.253 Remarks: .. I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature _QIJ_~ Ti tl e --L!:16t:L-._I&J-I~!:f-Itliz..V Date: ~/8/'iS- Form 10-422 Rev. 11/94 e e 3/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT February, 1995 Page 1 [ifu·p!anned Events less than or equal to 1 hour DATE TIME ,c",,(! VOLUME DESCRIPTION OF INCIDENT & CAUSe?> TOTAL 14,889 Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE ' TIME)f¡;: t(;b>' 'VOLUME> 2/5/95 0730-0900 348 ".' DESCRIPTION OF INCIDENT & CAUSEtM¡ ..> Rising ambient temp caused flare valve to open ACTION TAKEN ,TO ELIMiNATE ,CAUSE L'';~,:tÚ'';'" Reduced prod rates to minimize flared volume 2/5/95 1450-1630 716 See above See above 2/10/95 0000-0520 13,174 Lost "B" main due to thermocouple control Replaced failed exhaust thermocouples instrument failure 2/11/95 1800-1930 546 Rising ambient tempertures caused flare valve to Reduced prod rates to minimize tlare 2/12/95 1240-1410 512 High ambiernt tempertures forced the flare valve See above 2/12/95 1940-2120 10,617 Lost "B" main gas compressor with a control failure. Repaired bad control card and restart "B" main 2/13/95 1900-2130 1,136 Rising ambient tempertures caused flare valve to Reduced prod rates (phase 3 weather) 2/13/95 2210-2320 292 See above See above 2/15/95 1210-1320 138 See above Reduced prod rates to minimize tlare TOTAL 27,479 IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf , DA TEiTlME(iii;!,ÿ3!ii!;.i,i;!¡!¡ii¡'Šii'ŸVOLUMEii,!U'9¡¡iDEŠCRI~IIÖ~OBINCI[)ENJ'&¡ÇAt.J§g;0.¡;: 2/4/95 1730-1830 1277 Put well 2-14 on production ;f~':1d'::j{:iT1' "A"':"; i" :;~0:"/ACTION ,TAKEN TOELlMINA TECAUSE ¡;*-~;-¡ í£¡ .j;kL::!;':;! , r">,·.Sê:·-:~:(,"".."., ':....'.." .:.".' . .... ".':. ......, .,.":.. :...... .".: . ,,::.' . ,.,. :,'.:"... ...,. . ·c', .." .,'., ":..::, .". <':::::.:':.'.;:.:'>.'.:.:;'~::. ...~.,. '". :.:.::.·.·.:···:::,::,·:·,:.:",Æ Allow well to gas off at reduced choke setting 2/4/95 ·2010-2040 693 Flare test None; safety requirement 2/11/95 1320-1420 337 Put well 1-45 on production Allow well to gas off at reduced choke setting 2/12/95 1540-1610 641 Put well 2-14 on production See above 2/14/95 0500-0540 847 "B"-Main compressor shutdown Repair NGL bypass valve and restart "B"-Main 3/7/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT February, 1995 IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE·' TIME·' ""i~ih., '<V.OL.UMEA ~j::~;:DESCRIPT'ION,OF::;:INCI[)ENT;'&'CAUSE 2/14/95 0800-0840 245 Put well 1-27 on production 2/14/95 0900-0910 772 Put well 2-14 on production 2/18/95 1930-1950 639 Flare test - 2/21/95 2000-2050 4499 Bringing wells on production following TAPS TOTAL 9,950 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME',:;) DESCRIPTION OF INCIDENT&'CAUSEi'!S)¡;;;!0)/ 2/28/95 1120-1240 155 I Put well 2-14 on production following corrosion TOTAL 155 Page 2 /ACTlONTAKENTO ELlMINATECAUSE),t,.r¡'>:¡;\i!¡¿// ., Allow well to gas off at reduced choke setting See above None; safety requirement Reduce choke settings to allow wells to gas off > "ACTION TAKEN TOELlMINATE.CAUSE'¡y·· Reduce choke setting to allow well to gas off SDN ENDICOTT' Volume flared less than 1 hour 24,839 11 24,828 Volume flared greater than 27,634 12 27,622 1 hour e 4 9,208 Pilot Purge 9,212 Assist Gas 23.391 10 23.381 TOTAL FLARED VOLUME 85,076 37 .i 85,039 · . ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Faci I i ty Endicott Operator BP Exploration (Alaska) Inc. Field(s) Endicott 10450 Month/Year of Disposition Sag Delta North January, 1995 Disposition Volume MCF* *1£ production comes from multiple pools, indicate contribution of each pool to total. Pool Percent I. Sold o 220150 e 2. Reinjected 6,003 3. Flared or vented less than I hour 10 4. Flared or vented greater than I hour (Supplemenlal report required--See 20 AAC 25.235) 30 5. Pilot and Purge ECE~\ltD ---------,--_._,_.~._,_.._---------~---_._-_.._~_.__.~.....,....-~-------- 9 Official Use Only-Flaring Authorization> 1 hr. 6. Used for Icase operations t,lI I'" , ¡¡ ~ ') 1 10.(',(: £.. . ...;..;0 4,436 I. Safety MCF 7, Other NGL Gas Equivalent Assist Gas Alrrs}ca OiJ e~ G.Js. '_:u::1:;,;. CI~;iTI~11g3::Jn An ~no:2~c 1 8 I 24 2. Lease MCF e TOTAL 10,693 3. Conserv. Purposes MCF Note; All volumes must be corrected to prcssure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following thc month of disposition. Authority 20 AAC 25.253 Remarks: I hcrcby certify that thc forcgoing is true and correct to thc bcst of my knowledge. Signature _(2'D....L_~____ Ti tl c _¡.'1./M~a.__VÙL I ~-/-ðW------- Datc:___Z!LQlîS Form 10-422 Rev. 11/94 2/10/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT January, 1995 IUnplanned Events less than or equal to 1 hour DATE' '>TIME»" ji VOLUME),! !ii¡'¡">[)~SêFUÞTI()NÖF' NêIDENt,&CAlISE;:" TOTAL 5,774 Not required for unplanned events which are Jess than or equal to 1 hour IUnplanned Events greater than 1 hour . DATE VOLUME» DESCFUÞTIONOFINCIOENT&iCAÛSE¡r¡js\¡¡S1S.::; , 1/1/95 1700-1900 40 Ambient temp swing caused flare valve to open e 1/2/95 1300-1600 1,250 1/15/95 1940-2050 186 1/16/95 0110-0230 136 1/17/95 0940-1230 9,594 1/17/95 1250-1450 9,930 1/17/95 2100-2230 648 1/18/95 0100-0230 1,382 e 1/18/95 0900-1120 1,418 1/26/95 0140-0250 411 TOTAL 24,995 Plant SID & restart (high 1 st stage level) Running maximum rates, bumping flare. Rising ambient temp cause flare valve to open Page 1 !i ACTION TAKEN TOELIMINATECAUSEi::¡i\Hi' i+fè,,'¡.> Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE·" 'WKiii; S};¡jigy<' Reduced prod rates to minimize flare vol Adjust well chokes to minimize prod swings Reduced prod rates to minimize flare vol See above MGC A SID on a problem with waste heat recovery Repaired waste heat recovery unit, restarted MGC-A MGC A startup then SID due to thermocouple failure Replaced failed thermocouples & resstarted MGC-A Rising ambient temp caused flare valve to open See above See above Ambient temp swing caused flare valve to open IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME iVOLlIME'<. DESCRIPTION OF INCIDENT&.CAlISE;;' 1/4/95 1600-1700 350 Put well 2-52 on prod; allow well to gas off 1f7/95 0200-0230 670 1f7/95 0500-0530 120 Put well 1-67 on prod; allow well to gas off Put well 1-35 on prod; allow well to gas off Reduced prod rates to minimize flare vol See above See above See above ACTION TAKEN TO ELlMINATECAlISE.'/' ;'5<;( ;r.i Shut-in well 2-52 Adjust other wells to minimize flare See above 2/10/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT January, 1995 Page 2 IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf ¡J>;. DATE" .' TIME')'''i!4{;fh~wOLUM~ ,,;'~F:/bESCÁIPtION OF.INCIDENt'&>CAUSE ":"':"1;'" 1f7/95 0600-0630 120 ' Well 1·61 nitrogen lift and put on production e 1f7/95 1610-1710 220 1 f7/95 1900-1930 90 1/8/95 1920-1940 708 1/10/95 1140-1150 24 1/12/95 131 0-1340 36 1/12/95 1630-1650 20 1/13/95 0820-0840 35 1/13/95 1250-1300 66 1/13/95 1830-1850 44 1/14/95 0740-0750 1 1/14/95 1050-1130 247 1/14/95 1230-1250 33 1/14/95 1950-2010 579 1/16/95 1210-1240 139 1/19/95 1510-1520 29 1/20/95 0130-0220 329 1/20/95 0500-0600 215 e I i)i~i:: r,·' ACTION .TAKEN TO ELlMINA TE,CAUSE Lf;W,'* i%-,r;rfit;~ See above Put well 2-52 on prod; allow well to gas off See above Well 3-21 WSO squeeze Reduced prod rates to minimize flare Beginning well 3-19 WSO squeeze See above Well 3-19 inflow test No response taken due to short event duration POP well 3-21 following squeeze Reduced prod rates to minimize flare POP well 3-19 following squeeze See above Corrosion inhibitor treatment flowback Reduced prod rates to minimize flare See above No response taken due to short event duration See above Reduced prod rates to minimize flare See above No response taken due to short event duration See above Reduced prod rates to minimize flare See above See above Flare test None. Safety requirement Corrosion inhibitor treatment flowback Reduced prod rates to minimize flare Slowed MGCs to minimum speed for maintenance Completed work on main gas compressors Adjust wells to meet Alyeska proration requirement Reduced prod rates to minimize flare See above See above 2/10/95 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT January, 1995 (Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME «(",mg.!,', VOlUME·(";! '/DESCRIPTI()N()FINCíDÊNT&CAUSE'~;';!> "! 1/21/95 2100-2130 116 MGC anti-surge valve calibration 1/22/95 0210-0250 TOTAL 257 4,448 Well 2-18 squeeze work e (Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE ,;,:iJIM E :):";//'Ý;:4; '~::. V.OLUM E'Y ;,:,,; D,E:SCRI,RJlqN::,OF::'INCIDENT,&::'C,~US__E:.~I~f~ 0:;~f'!~:ffr~~Y ':;':::l¡«:;:~'?:,,::*: 1/14/95 1350-1500 288 Shutin high prod well. Tried to bring on more prod 1/16/95 1750-1900 159 Bleed 3-01 inner & outer annulus due to high pressure 1/17/95 0640-0750 160 Well corrosion & scale jobs caused prod swings 1/17/95 081 0-0920 718 See above 1/17/95 1520-1910 1,080 MGC A startup, prod swings 1/25/95 1450-1610 925 MGC performance testing (pre regulatory change permit #202.36) 1/26/95 081 0-0930 5,257 See above e TOTAL 8,587 Page 3 ACTION TAKEN TO ELIMINATE CAUSE See above See above ACTION TAKE,N TO ELIMINATE CAUSE Reduced prod rates to minimize flare , ",,;\¡ þ:::::i/":'8 lU-:&fi$J Minimize bleed rate; adjust well flowrates Adjust well flowrates to line out prod swings See abaove Adjust well flowrates to line out prod swings Flaring previously approved by AOGCC permit #202.36 See above Volume flared less than 1 hour 10,222 10 10,212 Volume flared greater than 33,582 30 33,552 1 hour Pilot Purge 10,199 9 10,190 Assist Gas 26.099 24 26.075 TOTAL FLARED VOLUME 80,102 73 80,029 .~ _ _c· _ WALTER J. HICKEL, GOVERNOR ALASKA OIL AND GAS CONSERVATION COMMISSION JIIOI PORCl:PL'ò[ DRJ\'[ A'liCIIORAGE. ALASJ.:A 99!'OJ -JI9: ""ONE: (907)279-I43J TEI.[COP\,: (907):76-7!'4: Novcmber 29. 1994 ADMINISTRA TTVE APPROVAL NO. 202.36 ENVIRONMENTAL DtC 0 1 1994 Rc: Additional narc volume. Endicott Oil Pool production facilitics. Duck Island Unit. Alison D. Cookc BP Exploration (Alaska) Inc. P. O. Bex 196612 Anchorage. Alaska 99519-66 I 2 .~ ··EG .;FFAIRS Dear Ms, Cooke: Wc have receivcd your IcUcr of Novcmber 28. 1994 requesting additional flare volume for the Endicott oil pool production facijity in the Duck Island Unit (DIU). The additional flarc "olume is rcquired during tcsting of the reccntly rcpaircd gas compressors. The Commission hereby approvcs flaring up to 30 MMcf of gas ovcr and above the dcsignated safety flare of thc Endicott production facility. Flaring is expccted to commcnce on or about November 29. 1994 and continue until work is complete. It is understood that gas flaring will be kcpt to a minimum whenever possible. and all volumes will be reported monthly on Alaska Oil and Gas ConseryaLÌon Commission form 10-422. DONE at Anchorage. Alaska and d<1ted Novcmber 29. ]994. c \ ~ .. ...,.....,. ~e!i:Jf---- Alaska Oil and Gas Conservation Commission -þc (u:_~/2rrÁ--- .______. I Tuckerman B<1bcock. Commissioner Alaska Oil and G<1S ConseT\'atÎon Commission e e