Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutUNOCAL - GRANITE PT. PLTFRM4 ,r,.;-gsq-/S';tt..,.. _....~ ,. ..i...u:9/~/~/6P/.~/.W/.~~/./~/.~/.~'/~,®.'d9/.~/d"/.9"/i°'.dY.4~/.abY./~/./~/S:.SV//.G/~P/~//.A/.~Y~/,~/.Y/B'/.Jm/.i'Y.~/p/.Y°/.P/~/~/O/n7/in/~/.ds/~Y~/0/®/O/~/~/.Y/~/®/.~/d~/~Yd'/.6~/~/.~/fa. ..:'~/...t .r AGoCC GAS Disposl~ion Files 1998 uNOG~c -6~AriTE i • .~ Y , x;a r/~,a~~:~nrniwr.~;;e~iari.~~a+i~ieri.~~wz~iaim;:rimwi.~s:~i,~i.~.~rs~i~i.~i..ri~iaaiw~.~iw~.~i.~;aaz~~.~i.~.~i.,~~.~r.~i.~i.~~.ri.~n~iais~iaer.~rmrairvi.~i.~r~ie~°ia^io~~~~iw~.Seri.~i.~i.~i,~i,~iwr~i~~mz~~~~.rrr.~ ~. ~ w,~ z ~~~ .~ s.t k.°... ~li C3. ~~ ~~ • ALASKA. OIL AND GAS CONSER~7ATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION ...:} ~~~~J'~ Facility ~ '~ei~~~i~l~~ ~ Operator Field(s) Month/Year of Disposition ~r~Q`yJi1vF nice Point Platform Unocal Oil and Gas Granite Point Dec 98 i <t~?t~ Disposition Volume MCF* 1. Sold 0 2. Reinjected _ 0 3. Flared or vented less than 1 hour 190 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 705 5. Pilot and Purge 620 6. Used for lease operations 40,556 7. Other 0 TOTAL items 1 - 7 42,071 8. NGL gas equivalent produced 0 9. Purchased gas 210 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 38, 962 6,031 Remarks: I hereby certify that he fore ing is true and correct to the best of my knowledge. Signature Title: Acct. Supervisor Date: 1!15/99 "Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 77.95% Hemlock Lease 18761 280152 5.69% Tyonek Lease 374044 280150 3.79% Tyonek Lease 374045 280150 12.57% Official Use Only •- Flaring Authorization > 1 hr 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 Form 10~d'22 Rev. d/95 GRANITE POINT PLATFORM EXCESS FLARE LOG DECEMBER 1998 Date Start Time End Time Event Hrs. Total MCF Source ID No. Equipment Description Category Oper/Safety Reason for Excess (Categorize, if possible) Planned or Unplanned 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 -1000 1100 1.0 . 493 Centaur compress Operational Scheduled maintenance Unplanned 13 0 14 0 15 0 16 0 - 17 0 18 0 19 0 20 0 21 1000 1400 4.0 212 Production wells Safety Other-State insp. well safety valves Planned 22 0 23 0 24 0 25 0 26 0 27 0 26 0 29 0 30 0 31 0 r I~ Total ~ 5.0~ 705 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition GRANITE POINT PLATFORM UNOCAL ALASKA RESOURCES GRANITE POINT FIELD NOVEMBER 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected p 3. Flared or vented less than 1 hour 399 4. Flared or vented greater than 1 hour (Supplemental report required -See 20 AAC 25.235) 93 5. Pilot and Purge 570 6. Used for lease operations 41,842 7. Other p TOTAL items 1 - 7 42,904 • 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: p 11. Transferred to: 42,487 Remarks: I hereby certify "tryh/at the foregoing is true and correct to the best of my knowledge. Signature ~~, ~~ ~ ~ Title ACCOUNTING SUPERVISOR Date 12/11/1998 Form 10-422 Rev. 4/95 *Indicate contribution of each pool to total. Pool Name Code Percent MIDDLE KENAI 280150 94.39 HEMLOCK UNDEFINED 280152 5.61 Note: All volumes must be corrected to pressure of 14.b5 psia and to a temperature of b0 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 DEC. 9.1998 2~38PM UNOCAL N0.913 P.1i2 EXCESS FLARE SUMMARY Granite Point Platform Nov-98 Dore Start Time End Time Event HrA. Toffi MCF Swncc ID No. Equipme~rl Dasari Cnmgory O ar Reason Car Excess , if posst'blo) .. Plermad or U fanned 1 0 - .. 3 . .. .. ..0 _. 4 0 ,.. . 5 • - --- --- 0 • ---. . .... 6 0 7 _... _.. .._ 0 .. __. . . ._ .. . S ... 0 .. . 9 _ 0 -- - --~- lU .. .. 0 ._... - •-- t ~ 0 . _ 12 _. , .0 ... . 13 0 --- 16 - _.. 0 .- _ ... -- . .-- ... _._. t8 0 _.-„ _ r 19 0 ...-- 21 ---• 0 . - _ . ._ --•-•--- 22 ... 0 ..._.. . -- --~- -- -• 0 - -- .. - 24 0 25 1000 1500 5.0 93 fv..02110 valve O 'anal Schodulod man+te~ plnntled 26 __ 0 ~_ . Z6 ~ 0 -~ ---._.- ._...___ .-- - -~ -- Z9 0 3l p -• -- • Tolal 5.0. . ~ . . 93 ~ _.... Report ONLY flaring events greats tfrm,l brnv or single ovenls ewcoeda~g 5 MMCI:. J,~cretional R_eeawnR for Exoeart Flaring: 3d Reasons for JVell kale Dlow down well Alarm tests Nall spikes OlVcr(d~'bc) IiZS Pufgimg Otlwr(dascn'bc) t a ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition GRANITE POINT PLATFORM UNOCAL ALASKA RESOURCES GRANITE POINT FIELD OCTOBER 1998 Disposition Volume MCF* 1. Sold p 2. Reinjected p 3. Flared or vented less than 1 hour 370 4. Flared or vented greater than 1 hour (Supplemental report required -See 20 AAC 25.235) 882 5. Pilot and Purge 620 6. Used for lease operations 41,529 7. Other 0 TOTAL items 1 - 7 43,401 8. NGL gas equivalent produced o 9. Purchased gas 1,042 10. Transferred from: p 11. Transferred to: 44,.876 Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature !~;~,,,~ ~~~ „~ ~ Title ACCOUNTING SUPERVISOR Date 11/16/1998 Form 10-422 Rev. 4/95 *Indicate contribution of each pool to total. Pool Name Code Percent MIDDLE KENAI 280150 94.31 HEMLOCK UNDEFINED 280152 5.69 Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by th~(~Zh of ~~ ~ month following the month ~cs~os~i~n:~,~ w,„ Authority 20 AAC 25.235 r~ , . ~~i~w CrO ~S. °vQi~:lll6SSti11i 131ChOIiA ARE SUMMARY oint Platform Oct-98 Date Start Time End Time Event Hrs. Totai MCF Source ID No. Equipment Description Category Oper/Safety Reason for Excess (Categorize, if possible) Planned or Unplanned 1 0 2 10:30 13:00 2.5 882 G-28 Gas Compressor Operational Unscheduled maintenance-instrument air failure Unplanned 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 Total ~ 2.5~ 882 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. Operational Reasons for Excess Flaring: Safety Reasons for Excess Flaring: Well tests Blow down well Alarm tests Other(describe) Weli spikes Other(describe) H2S Purging Scheduled maintenance Unscheduled maintenance Scheduled maintenance Unscheduled. maintenance ' - ~ ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION • C~ Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point Sept 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 how 119 4. Flared or vented greater than 1 how (Supplemental report required--See 20 AAC 25.235) 134 5. Pilot and Pwge 600 6. Used for (ease operations 41,509 7. Other 0 TOTAL items 1 - 7 42,362 8. NGL gas equivalent produced 0 9. Pwchased gas 0 10. Transferred from: Granite Point Plt. 0 GPTF-LEX I1. Transferred to: GPTF-GPP 45,738 4,410 Remarks: I hereby certifly that the foregoing is true and correct to the best of my knowledge. Signature~!~~~~,[],~~ `~~--~ Title: Acct. Supervisor Date: 10/16!98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 62.10% Hemlock Lease 18761 280152 26.67% Tyonek Lease 374044 280150 2.60 Tyonek Lease 374045 280150 8.63 Official Use Only -- Flaring Authorization > l hr 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volwnes must be corrected [o pressure of 14.65 psia and to a tempera[we of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 2S.23S Form 10-022 Rev. 4185 EXCESS FLARE SUMMARY Granite Point Platform Sep-98 Date Start Time End Time Event Hrs. Total MCF Source ID No. Equipment Description Category Oper/Safety Reason for Excess (Categorize, if possible) Planned or Unplanned 1 0 2 0 3 0 4 0 5 0 6 0600 1630 10.5 134 Operational Other-tank farm suction too low Unplanned 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 r L r Total ~ 10.5 134 { Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. Operational Reasons for Excess Flaring: Safety Reasons for Excess Flaring: Well tests Blow down well Alarm tests Other(describe) Well spikes Other(descdbe) H2S Purging Scheduled maintenance Unscheduled maintenance Scheduled maintenance Unscheduled maintenance ~ .~. ~,.~ ~ il', i ,~,, ~, ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION ;fi{" Facility ~ ~~t~1, `" Operator Field(s) MonthlYear of Disposition ;J~~~Eird'mte Point Platform Unocal Oil and Gas Granite Point August 1998 -~`.=.. nc.~ Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 74 4. Flared or vented greater than 1 hour (Supplemental re ort required--See 20 AAC 25.235) 932 5. Pilot and Purge 620 6. Used for lease operations 41,042 7. Other 0 TOTAL items 1 - 7 42,668 8. NGL gas equivalent produced 0 9. Purchased gas 316 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 51, 677 3,076 Remarks: I hereby certiVfy la he foregoin 's true and correct tg the best of my knowledge. Signature (/'YCf ~ Title: Acct. Supervisor Date: 9/15/98 v *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 62.10% Hemlock Lease 18761 280152 26.67% Tyonek Lease 374044 280150 2.60% Tyonek Lease 374045 280150 8.63% Official Uae Only -- Flaring Authorization > 1 hr 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes moat be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 Form 10~d22 Rev. J/96 SEP.16.1998 10~14AM UNOCAL ~CESS FLARE SUMMARY r5ranite Point Platform N0.312 P.2i3 Aug-98 .~ Data Start Time End Tu_nc Event Iirs. Tot®1 MCF Source ID No. Equipment 17oscri bn Category O S Reason tar Excess orize, if oasible Pintntc~l or Un lnmted ! 0 2 _ 0 4 0 5 - 0 _ 6 - _ 0 _. ._.. 7 _ 0 8 0 _„ .. 9 • ° 0 - ~• •- --•- - _ '~ 0 _ 12 ... . 0 ... - ..._. .._ 13 .... . . 0 . 14 , D .. .__ . IS D 16 _ 0 - -- 17 ... __ 0 ... . w -- _ 18 . .. ... D ~ _ _ .~, _ i9 - 0 _. . _. 0 .. .. . . 21 ... D .. , _ ... .._ ~ . .. 0 ... _ .. D _ ...... 2q 0 ~ ._. . ,. ,. D _ .. 26 0700 1000 3.0 685 entaur oom tional Scheduled mmntananea tanned 27 D ,.. _. 28 0 ... .._. ,-. ~ 0 ... 30 0800 1500 7.0 w 2a7 O etRfioaal Wcll sptltes Ianncd 31 ..... _ - 0 ~ -~- . . Total ..~~i - , _2:x, 2 .. , ~ _ Rcpai ONLY tinning evan~ greaser rhea 1 hour or sir~le events o~ocoading 5 MMCF. ALASKA OIL AND GAS CONSERVATION CONIlVIISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point July 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3, Flared or vented less than 1 hour 433 4. Flared or vented greater than 1 hour (Su lemental re ort re uired--See 20 AAC 25.235) 0 5. Pilot and Purge 620 6. Used for lease operations 42,242 7. Other 0 TOTAL items 1- 7 43,295 8. NGL gas equivalent produced 0 9. Purchased gas 168 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 51,030 3,374 Remarks: I hereby certify tl a he foregoing is true and correct to the best of my knp}vl,~dge., r Signature- Title: Acct. Supervisor Date: 8/7/98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 76.2790 Hemlock Lease 18761 280152 9.969 Tyonek Lease 374044 280150 3.1990 Tyonek Lease 374045 280150 10.5890 l~tllcial 1'ai: Only -- h i ~rm~; Auth~nizution > 1 Lr 1. Safety ~ MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report dua by the 20th of the month followittg the month of disposition. Authority 20 AAC 25.235 Form 10422 Rev. 4/96 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION L~ • Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point June 1995 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 Tyonek Lease 18761 280150 77.40% 3. Flared or vented less than 1 hour 368 Hemlock Lease 15761 280152 8.534'0 4. Flared or vented greater than 1 hour (Su lemental re ort re uired--Sea 20 AAC 25.235) 0 Tyonek Lease 379044 280150 3.269'0 5. Pilot and Purge 600 Tyonek Lease 374045 280150 10.S19o 6. Used for lease operations 41,632 7. Other 0 l~I(I~:Ir:l ~ ~-i: t~~l ~'~ 11:11111( ' 1 tl ,1'11 :111 '. - i ~ll TOTAL items 1 - 7 42,600 . , . _ _.__ _ __ _ _ 1. Safety MCF 8. NGL gas equivalent produced 0 2. Lease Use MCF 9. Purchased gas 226 3. Conserv. Purposes MCF 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 50,884 3,788 Commissioner Date Remarks: Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of I hereby certify th the foregoing is true and correct to the best of my knowledge. Signature ~= Title: Acct. Supervisor Date: 7/17/98 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 Form 10422 Rev. 9/96 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION • Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point May 1998 Disposition Volume MCF* 1. Sold 0 2. Rein}acted 0 3. Flared or vented less than 1 hour 417 4. Flared or vented greater than 1 hour (Su lemental re rt re uired-See 20 AAC 25.235) 1,851 5. Pilot and Purge 600 6. Used for lease operations 41,846 7. OtheY~ 0 TOTAL items 1- 7 44,714 8. NGL gas equivalent produced 0 9. Purchased gas b02 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 49,949 4,702 Remarks: I hereby certify th the foregoing is true and correct to the bast of my knowledge. Signature Title: Acct. Supervisor Date: 6/4/98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 90.1990 Hemlock Lease 18761 280152 9.519 Offici:.l l;sc U~il7 -- Flari~~g Auth~.~ri:<:,ti=gin > 1 hr 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 Form 10922 Rev. 4/86 EXCESS FLARE SUMMARY Granite Point Platform May-98 Date Start Time End Time Event Hrs. Total MCF Source ID No. Equipment Descri tion ~ Category (O erlSafety) Reason for Excess (Cate orize, if ossible) Planned or Un lanned 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 2100 2400 3.0 189 We1131-23 O erational Blow down well Planned 14 0 15 0 16 1600 2000 4.0 310 Onshore com . O erational Other-Onshore shutdown Un lanned 17 0 18 0 19 0 20 0 21 0030 0300 2.5 571 Centaur com ressor O erational Other-Centaur shutdown Un lanned 22 0 23 0 24 0 25 0 26 0 27 0 28 1400 2100 7.0 337 Oss compressor O erational OSS com ressor down for maintenance Planned 29 0930 1730 8.0 444 OSS com ressor O erational OSS com ressor down Planned 30 0 31 0 Total ~ 24.5 1,851 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. O erational Reasons for Excess Flarin Safety Reasons for Excess Flarin Well tests Blow down well Alarm tests Other(describe) Well spikes Other(describe) H2S Purging Scheduled maintenance Unscheduled maintenance Scheduled maintenance Unscheduled maintenance Page 1 ' ~ ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION u F£cility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point April 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 159 4. Flared or vented greater than 1 hour (Su lemental re ort re uired--See 20 AAC 25.235) 8,890 5. Pilot and Purge 600 6. Used for lease operations 39,124 7. Other 0 TOTAL items 1 - 7 48,773 8. NGL gas equivalent produced ~ 0 9. Purchased gas 0 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 53,560 4,208 Remarks: I hereby certify th the foregoing is true and correct to the best of my knowledge. Signature _ Title: Acct. Supervisor Date: 5/8/98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 250150 92.25 Hemlock Lease 18761 280152 7.72% ~lfll_ia,l Udo Gnly - Fl:,rir.~; Auchoi:z:+ti~.n ., 1 l,r 1. Safety ~ MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 Firm 10422 Rev. 4/96 • • EXCESS FLARE SUMMARY Granite Point Platform t Apr-98 Date Start Time End Time Event Hrs. Total MCF Souece ID No. Equipment Descri Lion Category (O er/Safe[ ) Reason for Excess (Cate orize, if ossible) Planned or Un lanned 1 0600 1700 11.0 8,321 GP-28 Solaz Com ressor O erational Scheduled maintenance Planned 2 0 3 0 4 0 5 0 6 0 7 0930 2400 14.5 102 VRU com ressor O erationa] Other-VRU re airs Un lanned 8 0000 2400 24.0 140 VRU com ressor Operational Other-VRU re airs Un lanned 9 0000 2400 24.0 136 VRU com ressor O erational Other-VRU re airs Un lanned 10 NA NA 35.0 191 VRU compressor O erational Other-VRU re airs Un lanned 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 Total ~ 108.5 8,890 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. O erational Reasons for Excess Flarin Safe[ Reasons for Excess Flarin Well tests Blow down well Alarm tests Other(describe) Well spikes Other(describe) H2S Purging Scheduled maintenance Unscheduled maintenance Scheduled maintenance Unschedu]ed maintenance Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION • Facility Operator Field(s) Month/Year of Disposition Granite Point PIatform Unocal Oil and Gas Granite Point March 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 33 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 26.23b) 0 b. Pilot and Purge 620 6. Used for lease operations 33,192 7. Other 0 TOTAL items 1 - 7 33,84b 8. NGL gas equivalent produced 0 9. Purchased gas 7.249 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Tranafened to: GPTF-GPP 54, 317 b,007 Remarks: I hereby certify t t the fore oing is true and correct to the best of my knowledge. Signature Title: Acct. Supervisor Date: 4J14/98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 2801b0 94.09% Hemlock Lease 18761 280162 5.91% Official Use Only -- Flaring Authorizations 1 hr 1: Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes moat be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authoritq 20 AAC 2b.23b p°rm iaaz2 ate. ores ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION r~ L J • Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point February 1995 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 Tyonek Lease 15761 280150 92.159 3. Flared or vented less than 1 hour 34 Hemlock Lease 15761 250152 7.555'0 4. Flared or vented greater than 1 hour (Su lemental re ort re uired--See 20 AAC 25.235) 39 5. Pilot and Purge 532 6. Used for lease operations 29,957 7. Otjler 0 l~ril_i:: U~ i-7nlc - l'I a:~n~,~ .~,il u; ti~.n . 1 hr TOTAL items 1 - 7 30,562 1. Safety MCF S. NGL gas equivalent produced 0 2. Lease Use MCF 9. Purchased gas 6,036 3. Conserv. Purposes MCF 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 50,582 4,469 __ _ ___`__ Commissioner Date Remarks; Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of I hereby 1 that the foregoing ' true a correc the best of my knowledge. Signa r _ ~ Title: Special Clerk Date: 3/9/95 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 ~r~A i ? ~ 199 Form 10422 Rev. 9/96 Alaska Oil & Gas Cons. Commission Anchorage • EXCESS FLARE SUMMARY Granite Point Platform Feb-98 ' Date Start Time End Time Event Hrs. Total MCF Source ID No. Equipment Descri tion Category (O er/Safe ) Reason for Excess (Cate orize, if ossible) Planned or Un Tanned 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 1430 1630 2.0 39 VRU O erational Other-PLC re air, VRU shutdown Planned 27 0 28 0 29 . 0 30 0 31 0 Total ( 2.0~ 39 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. O erational Reasons for Excess Flarin ~ Safe Reasons for Excess Flarin Well tests Blow down well Alarm tests Other(describe) Well spikes Other(describe) H2S Purging Scheduled maintenance Unscheduled maintenance Scheduled maintenance Unscheduled maintenance ALASKA. OIL AND SAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION v{) u' 1~ '41'~ g» ~;. ~ ., ,+1 ~: - Facility Operator Field(s) Month/Year of Disposition Granite Point Platform Unocal Oil and Gas Granite Point January 1998 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour 113 4. Flared or vented greater than 1 hour (Su lemental re rt re aired--See 20 AAC 25.235) 3,276 5. Pilot and Purge 3~ ~ 620 6. Used for lease operations ~~ ~ ~ 35,995 7. Other ~ ~ 4.-~ ~ ~ W 0 TOTAL items 1 - 7 ;,~, ~ 40,004 8. NGL gas equivalent produced 0 9. Purchased gas 4,087 10. Transferred from: Granite Point Plt. 0 GPTF-LEX 11. Transferred to: GPTF-GPP 53,049 4,508 Remarks: I hereby certify tha the fore oing is true and correct to the best of my knowledge. Signature Title: Special Clerk Date 2/18/98 *Indicate contribution of each pool to total. Pool Name Code Percent Tyonek Lease 18761 280150 92.40% Hemlock Lease 18761 280152 7.60% Oflizial U~cUuh~-I~lurin~~.~utlir,rizt~tir,u:, ] Iir 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235 ~~ ~ , t..: ~, e b:.,y, :) V' ,. Form 10 122 Rev. 4/96 C~ EXCESS FLARE SUMMARY Granite Point Platform • Jan-98 Date Start Time End Time Event Hrs. Total MCF Source ID No. Equipment Descri tion Category (O er/Safe[ ) Reason for Excess (Cate orize, if ossible) Planned or Un tanned 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 II 0 12 0 13 0 14 0 15 0 16 0 17 0930 1530 6.0 351 OSS com ressor O erational Other-OSS flare i in tie-ins Planned 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0700 1700 10.0 2,866 Centaur com resso O erational Scheduled maintenance Planned 30 1800 0600 12.0 59 O erational Wells ikes un tanned 31 0 Total ~ 28.0 3,276 Report ONLY flaring events greater than 1 hour or single events exceeding 5 MMCF. O erational Reasons for Excess Flarin Safe Reasons for Excess Flarin Well tests Blow down well Alarm tests Other(describe) Well spikes Other(describe) H2S Purging Scheduled maintenance Unscheduled maintenance