198-225
5HJJ-DPHV%2*& )URP:HOO,QWHJULW\6SHFLDOLVW&3)Q#FRQRFRSKLOOLSVFRP! 6HQW:HGQHVGD\$XJXVW30 7R5HJJ-DPHV%2*&:DOODFH&KULV'2*&%URRNV3KRHEH/2*&'2$$2*&&3UXGKRH%D\ 6XEMHFW&3$,IRUPVIRU6,LQMHFWRUVRQ$XJ $WWDFKPHQWV0,7.5813$'6,7(676[OV[0,7.58/$6,7(67[OV[0,7.588 6,7(67[OV[ ůůͲWůĞĂƐĞƐĞĞƚŚĞϭϬͲϰϮϲĨŽƌŵƐĨŽƌƚŚĞƐŚƵƚŝŶ͕ŶŽŶͲǁŝƚŶĞƐƐĞĚD/dͲ/ƐƉĞƌĨŽƌŵĞĚŽŶϮƵŐϮϬϮϮ͘WůĞĂƐĞůĞƚŵĞŬŶŽǁŝĨ LJŽƵŚĂǀĞĂŶLJƋƵĞƐƚŝŽŶƐŽƌĐŽŶĐĞƌŶƐ͘ 'XVW\)UHHERUQ :HOO,QWHJULW\6SHFLDOLVW &RQRFR3KLOOLSV$ODVND,QF 2IILFHSKRQH &HOOSKRQH &$87,217KLVHPDLORULJLQDWHGIURPRXWVLGHWKH6WDWHRI$ODVNDPDLOV\VWHP'RQRWFOLFNOLQNVRURSHQ DWWDFKPHQWVXQOHVV\RXUHFRJQL]HWKHVHQGHUDQGNQRZWKHFRQWHQWLVVDIH .58/$ 37' Submit to: OOPERATOR: FIEL D / UNIT / PAD: DATE: OPERATOR REP: AOGCC REP: Well Pressures: Pretest Initial 15 Min. 30 Min. 45 Min. 60 Min. PTD 1982250 Type Inj N Tubing 1110 1225 1240 1240 Type Test P Packer TVD 4900 BBL Pump 0.5 IA 580 1810 1750 1740 Interval 4 Test psi 1500 BBL Return 0.5 OA 900 900 900 900 Result P Well Pressures: Pretest Initial 15 Min. 30 Min. 45 Min. 60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures: Pretest Initial 15 Min. 30 Min. 45 Min. 60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures: Pretest Initial 15 Min. 30 Min. 45 Min. 60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures: Pretest Initial 15 Min. 30 Min. 45 Min. 60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result TYPE INJ Codes TYPE TEST Codes INTERVAL Codes Result Codes W = Water P = Pressure Test I = Initial Test P = Pass G = Gas O = Other (describe in Notes) 4 = Four Year Cycle F = Fail S = Slurry V = Required by Variance I = Inconclusive I = Industrial Wastewater O = Other (describe in notes) N = Not Injecting STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION MMec h an i c al In t eg r ity Tes t jim.regg@alaska.gov;AOGCC.Inspectors@alaska.gov;phoebe.brooks@alaska.gov chris.wallace@alaska.gov Notes: Notes: 2L-329A Notes: Notes: Notes: ConocoPhillips Alaska Inc, Kuparuk / KRU / 2L Pad N/A Hembree / Hills 08/02/22 Form 10-426 (Revised 01/2017)2022-0802_MIT_KRU_2L-329A 9 9 9 9 9 9 -5HJJ STATE OF ALASKA ALASKA.. AND GAS CONSERVATION COMMISSI REPORT OF SUNDRY WELL OPERATI S 1. Operations Performed: Abandon Other Repair well n Plug Perforations r Oil to WAG e p r 9 r Stimulate After Casing IT Rill Tubing r Perforate New Pool Waiver Time Extension Change Approved Program r Operat. Shutdow n r Perforate r Re -enter Suspended Well r 2. Operator Name: 4. Well Class Before Work: 5. Permit to Drill Number: ConocoPhillips Alaska, Inc. Development r' Exploratory r • 198 -225 3. Address: 6. API Number: Stratigraphic r Service r P. O. Box 100360, Anchorage, Alaska 99510 r 50 - 103 - 20272 - 00 7. Property Designation (Lease Number): 8. Well Name and Number: ADL 380052, ALK 4600 r ,2L - 329A 9. Field /Pool(s): Kuparuk River Field / Tarn Oil Pool 10. Present Well Condition Summary: Total Depth measured 6190 feet Plugs (measured) None true vertical 5557 feet Junk (measured) None Effective Depth measured 0 feet Packer (measured) 24, 5357, 5460, 5467, 5469 true vertical 0 feet (true vertucal) 24, 4798, 4892, 4899, 4900 Casing Length Size MD TVD Burst Collapse CONDUCTOR 80 16 108 108 0 0 SURFACE 2330 12 2358 2100 0 0 PRODUCTION 6143 8 6168 5557 0 0 0 0 0 U ,.. 0 0 0 yt 1s,, r f> ; 0 Perforation depth: Measured depth: 5783'-58414 RECEIVE True Vertical Depth: 5187' -5212' SEP 2 8 2011 Tubing (size, grade, MD, and TVD) 3.5, L -80, 5467 MD, 4899 TVD p� Oil & G ions. Coilmtission Packers & SSSV (type, MD, and TVD) HANGER - FMC GEN V TUBING HANGER @ 24 MD and 24 T SLEEVE-0 - BAKER CMU W /CAMCO PROFILE @ 5357 MD and 4798 TVD NIPPLE - CAMCO D NIPPLE @ 5460 MD and 4892 TVD LOCATOR - BAKER 80 -40 LOCATOR @ 5467 MD and 4899 TVD SEAL - BAKER 80 -40 SEAL ASSEMBLY @ 5469 MD and 4900 TVD NIPPLE - CAMCO DS NIPPLE @ 497 MD and 497 TVD 11. Stimulation or cement squeeze summary: Intervals treated (measured): Treatment descriptions including volumes used and final pressure: 12. Representative Daily Average Production or Injection Data Oil Gas - Mcf Water - Bbl Casing Pressure Tubing Pressure Prior to well operation SI SI SI 272 SI Subsequent to operation SI SI SI 200 SI 13. Attachments 14. Well Class after work: Copies of Logs and Surveys run Exploratory r Development r Service - I Stratigraphic r 15. Well Status after work: Oil r Gas r WDSPL Daily Report of Well Operations X GSTOR r WINJ r WAG ,F GINJ ❑ SUSP r SPLUG 16. I hereby certify that the foregoing is true and correct to the best of my knowledge. Sundry Number or N/A if C.O. Exempt N/A (Verbal approval) Contact Robert D. Christensen Printed Name Ro. = D. Ch 'st-nsen Title Prod Eng Specialist Signatur ") ° -, Phone: 659 -7535 Date %/ Form 10-404 Revised 10/2010 RBDMS SEP 28 20 1 r e 5. 27. ( Submit Original Only • i 2L -329A DESCRIPTION OF WORK COMPLETED SUMMARY Date Event Summary 04122/9°1 Opened well to production 04/27/99 Shut -in well long term (Returned to WAG injection Status) • Page 1 of 3 Schwartz, Guy L (DOA) From: Wilmot, Kelli A [ Kelli .A.Wilmot @conocophillips.com] Sent: Wednesday, July 13, 2011 5:01 PM To: Schwartz, Guy L (DOA) Subject: RE: 2L -329A PTO ! 4 1 8 Z z- Guy I knew there was a reference to this. I just had to track it down. Here are the production rates: Well Date Oil Rate Gas Rate Water Rate 2L -329A 04/22/11 2 1149 1057 2L -329A 04/23/11 1 1065 899 2L -329A 04/24/11 1 993 801 2L -329A 04/25/11 1 987 893 799 2L -329A 04/26/11 2 758 2L -329A 04/27/11 1 827 722 2L -329A 04/28/11 1 823 694 r' JUL t 2 011 2L -329A 04/29/11 3 787 658 2L -329A 04/30/11 3 795 658 Kelli From: Schwartz, Guy L (DOA) [ mailto:guy.schwartz @alaska.gov] Sent: Wednesday, July 13, 2011 4:37 PM To: Wilmot, Kelli A Subject: RE: 2L -329A My mistake... I didn't look in 2L -322 File . that's were the letter was filed. I need to put a copy in 2L -329 too. Good catch. Guy Schwartz Senior Petroleum Engineer AOGCC 793 -1226 (office) 444 -3433 (cell) From: Wilmot, Kelli A [mailto:Kelli.A.Wilmot @conocophillips.com] Sent: Wednesday, July 13, 2011 4:27 PM To: Schwartz, Guy L (DOA) Subject: 2L -329A Guy I did track down an email about the 2L -329A well. Kelli 7/14/2011 Page 2 of 3 • From: NSK Prod Engr Specialist Sent: Wednesday, July 13, 2011 4:22 PM To: Wilmot, Kelli A Subject: FW: 2L -322 PTD 210 -174 fyi Thanks, Darrell From: NSK Prod Engr Specialist Sent: Thursday, April 21, 2011 9:01 AM To: 'Schwartz, Guy L (DOA)' Subject: RE: 2L -322 PTD 210 -174 Guy- Your response is much appreciated. I will pass on the set point and 24 hr man -watch requirements to the Production Engineer. Thanks, Darrell From: Schwartz, Guy L (DOA) [mailto:guy.schwartz @alaska.gov] Sent: Thursday, April 21, 2011 8:58 AM To: NSK Prod Engr Specialist Cc: CPF2 Prod Engrs; DOA AOGCC Prudhoe Bay Subject: RE: 2L -322 PTD 210 -174 Darrell, Your request is granted. Please verify the set points for the SVS system are re- calibrated for flowback conditions and also that there will be a "24 man - watch" for the duration of the flowback. Report estimated production as you stated with the 404 sundry report. With the short duration of the flowback it is not necessary to change the well status to "oil ", Guy Schwartz Senior Petroleum Engineer AOGCC 793 -1226 (office) 444 -3433 (cell) From: NSK Prod Engr Specialist [mailto:n1139 @conocophillips.com] Sent: Thursday, April 21, 2011 7:50 AM To: Schwartz, Guy L (DOA) Cc: NSK Prod Engr Specialist; CPF2 Prod Engrs Subject: 2L -322 PTD 210 -174 AOGCC Attn: Guy Schwartz Guy, ConocoPhillips is requesting permission to flowback 2L -329A PTD 198 -225 for approximately one week, to assist drilling operations currently ongoing on 2L -322. Drilling has encountered elevated gas levels while drilling 7/14/2011 Page 3 of 3 I • through the Bermuda zone in this well. As 2L -329A is the closest injector to this well ConocoPhillips would like to flow it back to reduce reservoir formation pressure in the area. We plan to rig up temporary hardline to flow 2L- 329A to production via existing production piping on the pad. 2L -329A is equipped with a surface safety valve. Produced volumes from 2L -329A will be estimated from well tests using the drillsite facility. ConocoPhillips request verbal approval to proceed as drilling operations are currently in progress. A 10-404 Sundry will follow completion of operations. Thank you for your assistance in this matter. Darrell Humphrey / Bob Christensen ConocoPhillips Alaska, Inc. Production Engineering Specialist Office (907) 659 -7535 NSK -69 Pager (907) 659 -7000 (924) 7/14/2011 Page 1 of 1 Schwartz, Guy L (DOA) From: Schwartz, Guy L (DOA) Sent: Wednesday, July 13, 2011 3:18 PM To: Wilmot, Kelli A' Cc: McMains, Stephen E (DOA) Subject: RE: 2L -329A (PTD 198 -225) Kelli, I don't have any records of a request to backflow 2L -329A (PTD 198 -225) Normally an email request is sent in so we know that the set points on the SVS are changed and we can inspect. A sundry is not required for INJ to producer (backflow) ... if it stays backflowing for more than 30 days then a 404 is required. very short. change. Please send an email No 404 needed to report the status chan In this case the flow period was ery s o p g documenting the volume of fluids that was produced. That is all that needs to be done. In the future an email telling of us a planned backflow of an injector should be sent. Guy Schwartz Senior Petroleum Engineer AOGCC - 20 �c 793 -1226 (office) 444 -3433 (cell) From: Wilmot, Kelli A [ mailto: Kelli .A.Wilmot ©conocophillips.com] Sent: Wednesday, July 13, 2011 2:50 PM To: Schwartz, Guy L (DOA) Subject: 2L-2139A Guy This well was backflowed to production via temporary jumper in April. They wanted to reduce the high reservoir pressure in the Bermuda zone while they were drilling 2L -322. It flowed from 4/22 -4/30 and they shut it in. The well is an injector but is shut for Reservoir Management reasons. Kelli Wilmot 265 -6309 7/13/2011